American Standard 1340227.002 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

Connect water supply to FAUCET with 1/2" IPS FLEXIBLE
SUPPLIES (1) or 3/8" O.D. BULL-NOSE RISERS (2).
Use adjustable wrench to tighten connections. Do not over
tighten. Be careful not to kink copper supply when bending.
Use tubing cutter to cut to proper length.
MAKE WATER SUPPLY CONNECTIONS AND TEST
INSTALLED FITTING
M968493 REV.1.6 (8/19)
Plumbers' Putty or CaulkingAdjustable WrenchChannel Locks
Recommended Tools
1
2
INSTALL FAUCET
1340.225
1340.227
Certied to comply with ANSI A112.18.1
Thank you for selecting American-Standard...the
benchmark of fine quality for over 140 years.
To ensure that your installation proceeds
smoothly--please read these instructions carefully
before you begin.
Installation
Instructions
METERING
Centerset Faucets
2
3
4
5
1
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Insert faucet SHANKS through holes of SINK or
MOUNTING SURFACE.
Install GASKET (2), FRICTION WASHER (3), DEEP
WASHER (4) and LOCK NUT (5). onto SHANKS (6).
Tighten LOCK NUTS (5) rmly to secure FAUCET (1).
Apply a bead of PUTTY along the edge of the
underside of the FAUCET (1).
SINK OR
MOUNTING
SURFACE
PUTTY
SHANK
Turn off hot and cold water supplies before beginning.
CAUTION
1340.225
1340.227
COUPLING
NUT
1
2
2.5mm Hex Wrench
Hook
Tubing Cutter
Turn on water supplies and check connections for leaks.
Remove AERATOR (3) with KEY (4) supplied.
Operate HOT and COLD HANDLES by pressing down on
HANDLES. Both Hot and Cold handles are set for approximately
8 second operating cycles.
Replace AERATOR (3).
TEST INSTALLED FITTING
PRESS HANDLE
DOWN TO
OPERATE
3
4
WATER SUPPLIES
M968493 REV.1.6 (8/19)
Remove HANDLE (1) by removing INDEX BUTTON (2)
and SET SCREW (3) with a 2.5mm hex wrench.
Pull off HANDLE (1).
To increase cycle time, turn the white PLASTIC ADJUSTING
NUT (4) clockwise.
To decrease cycle time, turn the white PLASTIC
ADJUSTING NUT (4) counter-clockwise.
Replace HANDLE (1), SET SCREW (3) and
INDEX BUTTON (2). Test faucet for proper
operation and cycle time.
TO ADJUST CYCLE TIME
3
1
2
3
4
TO INCREASE CYCLE TIME
ROTATE CLOCKWISE
TO DECREASE CYCLE TIME
ROTATE COUNTER-CLOCKWISE
2.5mm HEX WRENCH
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
SERVICE
4
Remove HANDLE (1). Refer to Step 3 for handle removal.
Remove ACTUATOR ASSEMBLY (2).
Remove WASHER (3). Use small Hook to pull out VALVE
ASSEMBLY (4).
NOTE: The tip of the hook must catch on SURFACE (8)
to remove VALVE ASSEMBLY (4). Moderate force is
required. If the hook is too deep it will not remove
VALVE ASSEMBLY (4).
Open VALVE ASSEMBLY (4) by pulling VALVE BODY
TOP (5) off of VALVE BODY BOTTOM (6).
NOTE: There are three internal pieces including a spring.
Take caution not lose these components while opening
the valve body.
Ensure that O-RINGS (7) are free of any debris.
Remove O-RING (9), clean thoroughly, and ensure
the groove beneath is free of debris. Reinstall O-RINGS (9).
Reassemble VALVE ASSEMBLY (4) by pressing
VALVE BODY TOP (5) on to VALVE BODY (6)
until they lock with an audible snap.
Push VALVE ASSEMBLY (4) into faucet body. Place
WASHER (3) with collar facing down on top of
VALVE ASSEMBLY (4). See detail A. Thread VALVE
ACTUATOR (2) onto faucet. Torque VALVE ACTUATOR (2)
to 12-15 ft. lbs (15-20 Nm).
Replace HANDLE (1).
1
4
4
8
3
2
REMOVE REPLACE
Clean
Washer
Collar down
O-RING
DETAIL “A
69
7
5
  • Page 1 1
  • Page 2 2

American Standard 1340227.002 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI