Stark 92010-H User manual

Type
User manual

Stark 92010-H is a 26" Commercial 3-Speed Adjustable Misting Fan designed for cooling large areas and adding moisture to dry environments. It's perfect for patios, factories, athletic fields, greenhouses, and more. The fan head is constructed of heavy-gauge, anti-corrosive metal for safety and durability, and the quiet, high-efficiency fan motor provides optimal output in temperatures up to 104°F. With adjustable misting flow and a fully-insulated seal around the water pump, this misting fan can operate for up to 5 hours with each full tank, covering up to 1,000 square feet.

Stark 92010-H is a 26" Commercial 3-Speed Adjustable Misting Fan designed for cooling large areas and adding moisture to dry environments. It's perfect for patios, factories, athletic fields, greenhouses, and more. The fan head is constructed of heavy-gauge, anti-corrosive metal for safety and durability, and the quiet, high-efficiency fan motor provides optimal output in temperatures up to 104°F. With adjustable misting flow and a fully-insulated seal around the water pump, this misting fan can operate for up to 5 hours with each full tank, covering up to 1,000 square feet.

26” COMMERCIAL 3-SPEED ADJUSTABLE MISTING FAN
SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY,
OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S
SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH
AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).
OWNER’S MANUAL AND SAFETY INSTRUCTIONS
ITEM: 92010
For questions please call our customer support: (909) 628 4900 Mon-Fri 9am to 3pm PST
IMPORTANT SAFETY INFORMATION
GENERAL SAFETY WARNINGS
Read all safety warnings and instructions. Failure to follow the warnings and instructions
may result in electric shock, re and/or serious injury. Save all warnings and instructions
for future reference.
SAFETY
The warnings, precautions, and instructions discussed in this instruction manual cannot cover
all possible conditions and situations that may occur. It must be understood by the operator that
common sense and caution are factors which cannot be built into this product, but must be supplied
by the operator. Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS
before operating. Failure to follow the safety rules and other basic safety precautions may result in
serious personal injury.
1
Read and understand all instructions. Failure to follow all instructions may result in serious injury
or property damage.
To reduce the risk of re or electric shock, do not use this fan with any solid state speed control
device.
This product must be grounded. If it should malfunction or break down, grounding provides a path
of least resistance for electric current to reduce the risk of electric shock. Plug into in an appropriate
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not leave the fan running unattended.
Risk of re. Do not replace the attachment plug. Discard the product if the plug is damaged.
The misting fan should be used under rated voltage.
Connect to power supply only after the fan is fully assembled.
Never insert nger, pencils or any other object through the guard when the fan is running.
Be sure the fan is on a at, stable surface when operating to avoid tipping over.
Do not run the cord under carpeting or cover it with rugs, under furniture or appliances. Arrange the
cord away from heavy trafc areas and where it will not be tripped over.
Do not let the misting fan face any appliances.
Children should not be allowed around the fan. Adult supervision is recommended.
Any maintenance or modications to the misting fan should only be performed by a professional.
Installation and operation of the misting fan must comply with local utility standards. Improper use
may cause a re, electric shock and/or injury.
This free standing misting fan should never be hung or mounted on walls.
Make sure the system voltage and frequency are the same as local electrical outlet voltage and
frequency.
2
DIAGRAM AND SPECIFICATIONS
PRODUCT BENEFITS
Designed for cooling large areas such as patios, factories, manufacturing facilities, garages, athletic
elds, greenhouses and more.
Fan head constructed of heavy-gauge, anti-corrosive metal for safety and durability.
Quiet, high-efciency fan motor.
Adjustable misting ow with a fully-insulated seal around the water pump.
Adds moisture to dry environments and eliminates airborne dust particles.
Covers up to 1,000 square feet and features a 5-hour maximum run time with each full tank.
PRODUCT APPLICATION:
Cooling outdoors: Restaurants, recreation areas, waiting areas, work areas etc.
Suppressing dust: Removing atmospheric dust, recycling, waste and refuse handling. Pollution
control and to decrease odors.
Increasing humidity: Used in spinning mills, warehouses and to improve operations for all kinds of
livestock industries.
NOTE: After the rst 50-100 hours of use you will need to change the pump oil and also after every
300 hours. Use #30 engine oil only.
3
ASSEMBLY
DO NOT plug in the fan before assembly. This misting fan comes in 3 separate boxes. Carefully remove
all packaging materials and retain for future storage/use. Make sure there is no residual foam left in any
of the components. A screwdriver and wrench will be required to assemble this misting fan.
STEP 1. Remove the Water Tank from the Tank Cart
STEP 2. Installing the Water Pump: Remove the water pump
from the packaging. Position the pump in an upright position and
place it on the beam located at the bottom of the water tank.
STEP 3. Assembling the Stand Pole: Locate the tank cart and
stand pole. Remove the bolts, spring washers, at washers and nuts
from the tank cart. Position the stand pole on the tank cart and align
the holes on the pole with the four holes on the cart. Using the bolts,
washers and nuts removed in step a, screw the stand pole into the
tank cart. Make sure the stand pole is securely screwed onto the
tank cart before proceeding to the next step.
STEP 4. Assembling the Fan Head: Remove the fan head from
box #1. Align the stand pole opening on the bottom of the fan head
with the stand pole and connect the two pieces together. Use the
screw located on the screw attachment to secure the two pieces
together.
4
ASSEMBLY
STEP 5. Connecting the Power Supply: Insert the power line that is
connected to the fan head into the power line opening and screw in the
front panel to the stand pole. Insert the water output hose (hose #1)
and water input hose (hose #2) into the appropriate connectors on the
stand pole.
STEP 6. Connecting the Power Supply (Upper Back Panel): Remove
the upper back panel from the top of the stand pole by unscrewing the
screws holding it in place. Insert plug A into socket A and make sure
the connection is secure. Insert plug B into socket B and make sure
the connection is secure. Push all of the wires back into the stand pole
and reattach the upper back panel onto the stand pole using the screws
removed in step 1.
STEP 7. Connecting the Power Supply (Lower Back Panel): Place
the water tank on the tank shelf. Take the lower back panel that is
attached to the pump and locate plug C and socket C. Insert plug C into
socket C and make sure the connection is secure. Remove the screws
from the stand pole and screw the lower back panel onto the stand pole.
STEP 8. Connecting the Pump & Water Output Hoses: Remove the
tank cover from the water tank. Locate the pump hose (longer hose),
the water output hose (shorter hose) and the pump power cord. On the
bottom of the stand pole, there are 2 connections – one for the water
output hose and one for the pump hose. Securely connect the hoses to
the appropriate connections. Place the tank cover back onto the water
tank.
5
STEP 9. Locking/Unlocking the Handles : This misting fan is
equipped with handles for convenient transport. The handles
will be in the locked position when rst assembled. Follow these
steps to unlock and lock the handles. Refer to diagram 10. To
unlock the handles, push the L type pin on the handle joint.
While pushing in the L type pin, simultaneously push the handle
up. To lock the handles, push in the L type pin on the handle
joint and simultaneously push the
handle down to the lock position.
ASSEMBLY AND OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS:
1. This misting fan can operate with
optimal output in temperatures up to 104°F.
2. Lift up the tank cover and ll the tank with
clean water. Make sure the pump hose is
fully
submersed in water. Replace the tank cover.
3. Connect the fan to a power supply.
4. Turn on the fan by adjusting the
power switch to the ON position.
5. This misting fan has 3 different
fan speeds. Turn the fan speed
dial to adjust the fan speed.
6. To start the misting function, turn the
misting dial located on the stand pole. The
pump and
misting plate should power on at this time.
7. To adjust the misting
volume, turn the misting dial.
8. To empty the tank of water, adjust the
drainage valve located on the back of the
water tank.
6
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR
DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE
UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER
ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL
PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION
OF REPLACEMENT PARTS THERETO.
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only and are not available individually
as replacement parts.
PLEASE READ THE FOLLOWING CAREFULLY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Stark 92010-H User manual

Type
User manual

Stark 92010-H is a 26" Commercial 3-Speed Adjustable Misting Fan designed for cooling large areas and adding moisture to dry environments. It's perfect for patios, factories, athletic fields, greenhouses, and more. The fan head is constructed of heavy-gauge, anti-corrosive metal for safety and durability, and the quiet, high-efficiency fan motor provides optimal output in temperatures up to 104°F. With adjustable misting flow and a fully-insulated seal around the water pump, this misting fan can operate for up to 5 hours with each full tank, covering up to 1,000 square feet.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI