2
3
4
5
6
7
1
8
9
CIRCUIT
BREAKER
CIRCUIT A
CONTACTOR
BROWN
BLUE
GREY
TERMINAL
BLOCK
LIMIT
ELEMENT
T2
T1
L2
L1
COMPRESSOR
CONTACTOR
ORANGE
9-PIN
HEATER PLUG
WHITE
RED
BLACK
RED
REDBLACK
WIRING DIAGRAM
NOTES:
1. Circuit breakers are not wired to heater kit by the factory, see
Installation Instructions for wiring procedure.
2. If any of the original wire supplied with this unit must
be replaced, it must be replaced with wiring material
of the same gauge size and temperature rating.
The installation of this heater kit may require a change
in the blower speed tap connection. See Installation
Instructions for details.
3. Use copper conductors with a minimum temperature rating
of 60 C for supply connections.
7114400
08/14
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
5 kW, 1-Circuit, 1-Phase Electric Heater KitH3HK005H-01C 240VAC
  • Page 1 1

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI