Montigo RFKFID is an optional fan kit that can be installed with Montigo 30FID-L/S and 34FID-L/S fireplaces. This kit includes a left high output fan, a right high output fan, mounting screws, cable ties, a 34FID flue plate gasket, and a 30FID flue plate gasket. The fans are designed to provide many years of trouble-free service and can be tested with the gas supply turned off or disconnected. To test the blower operation, reconnect the electrical supply temporarily and be sure to disconnect it after testing.

Montigo RFKFID is an optional fan kit that can be installed with Montigo 30FID-L/S and 34FID-L/S fireplaces. This kit includes a left high output fan, a right high output fan, mounting screws, cable ties, a 34FID flue plate gasket, and a 30FID flue plate gasket. The fans are designed to provide many years of trouble-free service and can be tested with the gas supply turned off or disconnected. To test the blower operation, reconnect the electrical supply temporarily and be sure to disconnect it after testing.

Optional Fan Kit
Installing the RFKFID High Output Fan Kit or
RFKFIDECO Economy Fan Kit
Page 1 XT0022 - 150629.3
This kit should be installed by a qualied person.
Check local codes and read all instructions prior to
installation.
Ensure that all power to the appliance is off at the electrical breaker or fuse
before beginning installation. Ensure gas is turned off at the shutoff valve before
beginning installation.
CAUTION
Optional Fans for use with:
30FID-L/S
34FID-L/S
General Information
This blower kit is for installation with the models listed above.
®
C
US
Before You Begin
Please read all instructions carefully
We strongly recomment that all electrical service work be
performed by a qualied electrical contractor.
Check to ensure that all components required for installa-
tion are included in your package.
KIT # Contents
RFKFID Left High Output fan, Right High Output fan, mount-
ing screws, cable ties, 34FID
ue plate gasket, 30FID ue plate gasket.
RFKFIDECO Left Economy fan, Right Economy fan, mounting
screws, cable ties, 34FID
ue plate gasket, 30FID ue plate gasket.
Figure 1 RFKFID
Cable ties and
fan mounting
screws
Left fan Right fan
34FID gasket 30FID gasket
Figure 2 RFKFIDECO
Cable ties and
fan mounting
screws
Left fan Right fan
34FID gasket 30FID gasket
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
WARNING
Installation
Page 2
XT0022 - 150629.3
Figure 3
The Optional Fans or Blowers supplied with your fan kit
are the best quality available and should provide many
years of trouble free service. There are two blowers for
this appliance, one motor on the right side and the other
on the left side.
** If the replace is installed, the Gas Supply may need
to be disconnected from the appliance. If this is the case,
a licensed gas tter will need to provide this service. **
Figure 4
Installation
Removing the Back Panel of the Fireplace
1). If the replace is already installed, please refer to fan
replacement section in your replace installation and
maintenance manual.
2). Unpack fan kit. The gaskets supplied with the kit are
only for fan replacement. Discard if not needed. Both the
RFKFID and RFKFIDECO Install the same way. Installa-
tion images show high output fans.
3). Remove all screws necessary to remove the Outer
Shell Back.
4). If installing the fans into a 30FID, remove the six
screws highlighted in Figure 4 and skip Step 5. If install-
ing the fans into a 34FID, proceed to Step 5.
Figure 5
5). Remove the four screws highlighted in Figure 5.
Installation
Page 3XT0022 - 150629.3
Figure 6
Figure 7
6). Install fans into the back of the replace.
7). Secure each fan using 3 screws (for 30FID) and 2
screws (for 34FID).
8). Connect the Fan Wire Harness at the back of the
appliance.
9). Connect the Fan Wire Harness underneath the
valve.
Figure 8
Figure 9
Installation
Page 4
XT0022 - 150629.3
11). If desired, it is possible to test the Blower operation
with the Gas Supply turned off or disconnected. To test
the Blower operation, re-connect the electrical supply
temporarily. Be sure to disconnect the Electrical Supply
after testing the Blowers.
Figure 10
12). Re-install the Outer Shell Rear panel.
13). Refer to replace manual for replace installation.
10). Secure the Wire Harness with the cable ties as
shown in gure 10 and 11.
Figure 11
Page 5
XT0022 - 150629.3
Notes
XT0022 - 150629.3
I-Series Optional Fan Kit
RFKFID
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Montigo RFKFID User manual

Type
User manual
This manual is also suitable for

Montigo RFKFID is an optional fan kit that can be installed with Montigo 30FID-L/S and 34FID-L/S fireplaces. This kit includes a left high output fan, a right high output fan, mounting screws, cable ties, a 34FID flue plate gasket, and a 30FID flue plate gasket. The fans are designed to provide many years of trouble-free service and can be tested with the gas supply turned off or disconnected. To test the blower operation, reconnect the electrical supply temporarily and be sure to disconnect it after testing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI