Read this user manual before operating
The company reserves the right of final decision on the interpretation of this manual
Read and save this user manual together with sales invoice
The company reserves the right to upgrade or make technical change to this product
without further notice
For product outlook, refer to the actual appearance
9
7
1
10
11
13
Contents
Precautions
Product Components
Usage
Cleaning & Maintenance
Troubleshooting
Technical Specification
Warranty
5
B
IOZONE
®
S
CIENTIFIC
BIOZONE
®
SCIENTIFIC
Precautions
This appliance is not intended for use by persons (including children) with
reduced physical,sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Unintended use of the appliance or damage to the housing may result in the
escape of dangerous UVC radiation. UVC radiation may, even in little doses,
cause harm to the eyes and skin.
This appliance contains a PhotoPlasma/ UVC generator.
Appliances that are obviously damaged must not be operated.
Read the maintenance instructions before opening the appliance.
The appliance must be disconnected from the supply before replacing the
PhotoPlasma/ UVC generator.
Any content marked with this sign refers to prohibited
behavior, otherwise it may cause damage to the product
or harzard to the user.
Any content marked with this sign must be strictly
followed, otherwise it may cause damage to the product
or harzard to the user.
Any content marked with this sign must be paid attention to,
otherwise it may cause damage to the product .
Notice
Warning
Do not insert fingers or foreign
objects into the air-inlet or
outlet.
Prohibited
Do not plug the power cord
when your hands are wet.
Note: The following content is related to safety, please read and follow the instructions
for proper usage.
Precaution is related to safety risk and hazardous situations.
1. Do not use any accessories unless it is recommended in this manual; otherwise,
warranty will be void.
2. After unpacking, check the product for any damage and if all accessories are included.
3. Usage of this product by children and people with disabilities should be supervised.
4. If a fault occurs, unplug the power cord immediately . Do not operate the air purifier
if it is defective.
5. The air purifier should be repaired by authorized service centres, as repair by
non-authorized party may cause safety issue.
6. If the power cord is damaged, please contact the authorized service centre and have
qualifed technicians to replace the cord. Do not replace the cord on your own as
it may be dangerous.
Precautions
Do not use the air purifier in
an environment filled with
hydrogen, natural gas, propane
and other flammable gases.
Do not use the air purifier while
spraying pesticides. Do not use the
air purifier near cigarettes, incense,
or other spark-generating items.
Do not use in areas with high
humidity or where the air purifier
may become wet such as in the
bathroom.
Do not block the air inlet / outlet.
Do not operate the air purifier
without installing the filters.
Clear the dust on the power
plug regularly.
Do not wash and reuse the
composite carbon filter mesh.
Please use only the power supply
voltage indicated on the rating
label.
Precautions
Please be careful when cleaning
the air purifier. Strong corrosive
detergents can damage the
surface of the air purifier.
Hold the plug when unplugging
the power cord and do not pull
the cord. Otherwise it may result
in electric shock or fire because of
short circuit.
Please unplug the power cord when
cleaning or not using the air purifier
in case of electric shock or fire
because of short circuit.
Use only soft cloth to clean the
surface of the air purifier,
otherwise it may damage or
scratch the unit itself.
Do not use the air purifier if power
cord or plug is damaged or the
power socket outlet is loose.
If this air purifier causes interference
to radio or television receiver, please
try one or more of the following
measures to correct the interference:
• Re-adjust the antenna direction
on the TV.
• Move the air purifier further away
from the radio / television receiver.
• Connect the air purifier's power
supply and the TV or radio’power
supply to different power outlets.
• For assistance, please contact your
nearest dealer or an experienced
radio / TV technician.
Precautions
Do not place air purifier near any
heat sources (wall mounted heater
or area near flammable gases).
While moving the air purifier, hold
the handle on the back of the main
body. If you hold the front cover
while moving, it may fall off from
the main body and cause injury.
Do not use alcohol or organic
solvents to wipe and clean the air
purifier as it may damage the air
purifier or trigger electrical shock,
causing damage, fire etc..
This device should not be operated
by people with disabilities or
children without supervision.
Green
Yellow
Remarks: Air Quality Indicator is displayed according to PM2.5 Index.
Product Components
Product Components
Blue
Red
A. Front Cover B. Pre-Filter C. Composite Carbon Filter Meshs
J. Air Quality Indicator K. PhotoPlasma/ UVC Generator
G. Airduct H. Sensor Cover I. Power Socket
D. LED Display E. Control Panel F. Switch to open the front cover
Excellent PM2.5 Index ≤50
Good 50<PM2.5 Index ≤100
Fair 100<PM2.5 Index ≤150
Poor 1 50<PM2.5 Index
FH
J
I
G
K
B
IOZONE
®
S
CIENTIFIC
1. Power ON/OFF: Touch ” “ button to turn on/ off
2. Purify: Touch “ ”to activate/ shut down PhotoPlasma/ UVC
purifying function. When turned on, PhotoPlasma/ UVC purification
function will be set according to the last shutdown setting
3. Fan Speed: Touch“ ”button to adjust fan speed in the following
sequence: Level 1-2-3-4-5 . The fan will go back to Level 4 after 60
minutes operation at the speed of Level 5
4. Timer: Press “ ” button to select the time required in the
following sequence : 1H>2H>3H>4H>5H>6H>7H>8H>9H>10H>
11H>12H>0H
5. Auto: Touch “ ” button to start/ end the AUTO mode
6. Sleep: Touch“ ”button to start/ end the SLEEP mode
7. Child Lock: Hold “ ”button for 5 seconds to lock the buttons
and avoid misoperation by children
Product Components
Control Panel
Control Panel Overview
Operating Instructions
PM Index, Timer, Fan Speed Display
2. Remove the pre-filter by pulling it out. (Fig. 2)
Usage
Before Use
Unpack the filters and install them properly into the air purifier before use.
Filter Removal
Fig. 1 Fig. 2
3. Remove the composite carbon filter meshs by pulling them out holding
the handles. (Fig.2)
1. Remove the filters from plastic bag before use and open the front
cover. (Fig.1)
While using the air purifier, place at least 2 meters away from other electronic
appliances that emit electromagnetic waves (such as, TV, radio, clock) to prevent
interference.
Do not place the air purifier near curtains and other objects that may interfere with
the air inlet or outlet, otherwise it may cause malfunction.
Do not place the air purifier where temperature may change vastly. Its operating
temperature is 0–35℃.
Place the air purifier in a secured and well ventilated area. If the air purifier is placed
on a thick carpet, it may vibrate slightly.
Do not place the air purifier where cookng fume may generate (such as kitchen).
Ensure there is enough space around the air purifier.
Place the air purifier where air can flow naturally. This allows PhotoPlasma/ UVC and
negative ions to spread evenly.
B
IOZONE
®
S
CIENTIFIC
2.Install pre-filter: place the pre-filter in the air purifier where 6 fittings click into
place. (Fig. 3)
1.Install the composite carbon filter meshs: remove the plastic bag, place the filter
inside with the handles facing out. (Fig. 3)
Notice:
Please remove
the plastic bag
of composite
carbon filter mesh
Usage
Filter Installation
Connect the provided power cord to AC supply voltage indicated on the rating label
and press“ ”to turn on/ off.
3.Install the front cover: insert the bottom tabs into the slots at the lower part and
close the front cover until the magnets pull the cover closed. (Fig.4)
Operation
Pre-filter
Composite carbon filter meshs
Fig.3 Fig.4
Press " " button to adjust the fan speed manually for Level 1-2-3-4-5,
Level 5 fan speed will automatically switch back to Level 4 after running for
60 minutes.
Press " " button to start/ exit SLEEP mode.
Press " " to start/ exit AUTO mode .
Press " " button for 5 seconds to start/ exit child LOCK mode to avoid any
hazard to children.
Press " " button to select the time : 0H to 12H. When the air purifier is on, the
selected time is set to auto shut down. When the air purifier is off, the selected time
is set to auto turn on.
+
Filter Reset: After filter replacement, reset the filter's lifetime counter by
pressing“ ” and “ ”simultaneously for 3 seconds.
PhotoPlasma
/ UVCGenerator
Press " " to activate PhotoPlasma/ UVC Purifying Function. Press " " again
to shut down the function.
B
IOZONE
®
S
CIENTIFIC
Pre-filter Not required Do not damage it when cleaning
3) Pre-filter can be rinsed with water and reused after drying completely.
3. Cleaning and Replacing of PhotoPlasma/ UVC Lamp
(Please refer to the Appendix for the correct procedure)
1) If stains are found on PhotoPlasma/ UVC Lamp, remove the lamp from the machine first
and clean it with soft cloth soaked with detergent water. After cleaning, reinstall the lamp.
2) For optimal performance, it's suggested to replace PhotoPlasma/ UVC Generator once
a year.
3) If replacement of PhotoPlasma/ UVC Lamp is needed, please make sure that the lamp is
installed properly.
Precaution: When cleaning or replacing the PhotoPlasma/ UVC Lamp, please handle
the lamp by the white ceramic side on the ends. Do not touch the glass part
of PhotoPlasma/ UVC Lamp with bare hands.
Cleaning & Maintenance
Cleaning & Maintenance
Turn off and unplug the power cable before cleaning / replacing filters.
1. Cleaning Care
1) Wipe the product body with a soft cloth.
2) For tougher stains, clean it with a soft cloth soaked with detergent water.
2. Filter Care
1) Both “AUTO” and “TIMER” buttons flashing indicates it is time for filter
replacement. However, the frequency of filter replacement varies depending
on environment. It is suggested to clean the filters every month. If the filters
are soiled or have a bad odour, please replace the filters immediately.
2) For optimal performance, composite carbon filter mesh can be cleaned with a
vacuum to extend its lifetime. (Suggest to clean it every month)
When to replace Condition
Last up to 6 months
Upper Composite
Carbon Filter Mesh No more than 6 cigarettes daily
Please dispose the used filters as non-combustible item.
The lifetime of the filters will be possibly shortened if the
environment is heavily polluted or more smokers are involved.
Lower Composite
Carbon Filter Mesh Last up to 12 months No more than 6 cigarettes daily
Do not damage it when cleaningPhotoPlasma/ UVC Lamp Last up to 12 months
Symptom Possible Causes and Solutions
Air purifier does
not turn on
1. Check if the power cord is well plugged in.
2. Check if the front cover is installed properly.
Air purifier does not
improve indoor air
quality significantly
Abnormal smell comes
out of the air outlet
Airflow from outlet
is weakened
Notice: If the problem persists after checking the above troubleshooting,
please contact your local service centre. Do not disassemble the unit yourself.
Troubleshooting
Troubleshooting
1. The plastic bag for filters has not been removed; remove the
plastic bag and reinstall the filters.
2. Other items block the inlet/ outlet; clear the items.
3. Clean or replace the filters.
1. Filters are not installed; install the filters.
2. Doors or windows are opened frequently so that it takes more
time than expected for device to purify the indoor air.
3. Air purifier is placed in a small place or with obstacles nearby
which affects the purifying result.
4. Clean or replace the filters.
1. Heavy indoor air pollution because of a lot of smokers, dust
or odours; It's recommended to enhance air exchange.
2. Clean or replace the filters.
PhotoPlasma
/ UVC
Lamp
does not light up
1. Check if the PhotoPlasma
/ UVC
Purifying Function has been
activated.
2. PhotoPlasma
/ UVC
Lamp is out of order. Please replace the
PhotoPlasma
/ UVC
Lamp.
Technical Specification
Technical Specification
100W
FCC-30
50Hz or 60Hz120V~ or 220V~
350m³/h
P4
High Efficiency
130m /h
420x240x690mm
10kg
12.2kg
Net Weight
Gross Weight
Dimension
Product Name FreshCare Series Model
Rated Voltage *1 Rated Frequency
Noise Level 64dB(A)
Rated Power Input
Cumulate Clean Mass (PM)
Clean Air Delivery Rate (PM)
Cleaning Energy Efficiency (HCHO)
Qualified
Cleaning Energy Efficiency (PM)
Effective Room Size
PM 2.5 Sensor
Sensor
Clean Air Delivery Rate (HCHO)
27-46
³
Specifications are subject to change without notice.
*1 : Please use only the power supply voltage indicated on the
product label.
Generators Equipped Negative Ion, PhotoPlasma
/ UVC
Replaceable Filters and PhotoPlasma/ UVC Lamp (For Sale)
FCC-30-FA2/FCC-30-FA2H13
Upper Composite carbon
filter mesh H11/H13
FCC-30-PFPre-filter
Power Cord User Manual
Appendix
Warranty Card Air Purifier
Type Model Number
Packing List
Item Quantity Item Quantity
Technical Specification
PhotoPlasma/ UVC Lamp
FCC-30-FB2/FCC-30-FB2H13
Lower Composite carbon
filter mesh H11/H13
10-08100/10-08000
Lamp Cover
*Please contact the authorized service centre for ordering in details .
FCC-30-LC3
FCC-30-FA2/
FCC-30-FA2H13
Product Warranty
What is covered: All parts defective in material and workmanship.
For how long: One year from the purchase date.
What we will do: Repair or replace any defective parts.
What you must do:
1. Contact your sales representative or dealer or call BIOZONE at +44 (0) 1392 860 862
( Headquarters/ EMEA) for specific return and shipping instructions.
2. Pack the product in its original carton and in the same manner you received
(or identical as possible).
3. Return the product with proof of purchase.
4. Label and ship the unit, freight prepaid, to the address provided.
5. Place any necessary return authorization number prominent on the outside of the
carton.
Other Terms and Conditions:
The provisions of this warranty are in lieu of any other written warranty, whether
expressed or implied, written or oral, including any warranty of merchantability or
fitness for a particular purpose. The manufacturer's maximum liability shall not exceed
the actual purchase price paid by you for the product. In no event shall the manufacturer
be liable for specific, incidental, consequential or indirect damages. This warranty does
not cover a defect resulted from improper or unreasonable use or maintenance,
accident, improper packing, or unauthorized tampering, alteration or modification as
determined solely by us. This warranty is void if the label bearing the serial number
has been removed or defaced.
Warranty
Warranty Conditions
Version: 2021 V1
Asia/Pacific
Website: www.biozonescientific.hk
BioZone Scientific International,Ltd.
Unit 1101,11th Floor, Tins Enterprises Ctr.
777 Lai Chi Kok Road
Kowloon, Hong kong
Tel:+(852) 2372 0218
EPA Producer
Establishment No.
98681-CHN-1
USA
BioZone Scientific America LLC
7616 Southland Boulevard
Orlando, Florida 32809
United States of America
Tel: 1+407.876.2000
Website: www.biozonescientific.com
Website: www.biozonescientific.com
Tel: +44 (0) 1392 860 862
United Kingdom
EX1 2JY
Exeter
72 Paris Street
1st Floor, The Mount
BioZone Scientific Group Limited
Headquarters/Europe/Middle East/Africa
BIOZONE
®
SCIENTIFIC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

BIOZONE SCIENTIFIC FCC-30 FreshCare Series Air Purifier User manual

Category
Air purifiers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI