Avolta

eLICHENS Avolta User manual

  • Hello, I have analyzed the Avolta user manual and am now ready to assist with your questions. The document explains how to perform battery and alarm tests, interpret LED indicators, and what to expect when a gas alarm is triggered. I can answer questions about the features and operation of this gas alarm.
  • How to test the battery?
    What happens during an alarm?
    What does a blinking orange LED mean?
Green: Device statusPower
Trouble
Alarm
Blinks 1 time every 10sec when battery is low
Orange: Device trouble
Blinks twice every 10sec when the device is on end of life mode
Red: Gas alarm
Blinks every 10sec when gas concentration is above threshold
+ Pre-recorded message on speaker every minute
Battery test
Blink the green LED 3 times
Alarm test
Beep + Pre-recorded voice message + red LED blinking
sec
1
sec
10
Green LED blinks every 10sec during starting sequence
Before each installation please reconnect the battery
then press TEST button for 10 sec.
Avolta User Manual
Avolta Datasheet
Get access to : SCAN THIS
QR CODE
or click on this link
elichens.com/avolta-start
Visit elichens.com for more information or contact us at [email protected]
Keep
Avolta
in a methane-free environment
during the 12 min warm-up.
wait
12
Unscrew Plug-in Close & tighten
Green LED blinks every 10sec
during starting sequence
+ Beep
/