ANETS AV SERIES INSTALLATION & OPERATIONAL MANUAL
8 150-000004 Rev A (2/19)
CE GAS TABLE
Refer to the following table for gas specifications for the country of use. If the country of use is NOT listed, refer
to the information printed on the data plate.
Belgium – Natural gas units require a restrictor orifice on the supply line for proper operation.
If the appliance requires a heat deflector, you will find a removable label at the rear top edge of the unit. This
label has instructions for positioning and installation of the heat deflector. Refer to the label and the
instructions below to install the deflector.
1. Remove the two self-drilling screws from the top, back area of the appliance.
2. Position the heat deflector so that the angled portion of the deflector is facing toward the front of
appliance. Secure the heat deflector to the back of the unit using the two previously removed
fasteners.
3. When properly installed the angled section of the heat deflector will extend over the flue opening to
redirect the heat. It SHOULD NOT cover the flue opening. Never allow anything to block the flue
opening; this will cause the appliance to overheat and inhibit proper combustion, which could produce
dangerous gases
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT, LT, LV, NO,
PL, PT, RO, ES, SI, SK, SE, TR I
2H
LU I
2E
FR I
2ESI
BE I
2E+
NO
DE I
2ELL
2.2 mm / #40
NL G25-G25.3 I
2L
- I
2EK
25 2.38 mm 2.3/2.2
BE, BG, CH, CZ, DE, ES, FR, GB, GR, HU, HR, IE, IS, IT, LT,
LU, LV, MK, MT, NL, PL, PT, RO, SI, LP G31 I
3P
18.9 37 37 #54 LP16 0.8
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT, LT, LV, NO,
PL, PT, RO, ES, SI, SK, SE, TR I
2H
LU I
2E
FR I
2ESI
BE I
2E+
NO
DE I
2ELL
2.2 mm / #40
NL G25-G25.3 I
2L
- I
2EK
25 2.38 mm 2.9
BE, BG, CH, CZ, DE, ES, FR, GB, GR, HU, HR, IE, IS, IT, LT,
LU, LV, MK, MT, NL, PL, PT, RO, SI, LP G31 I
3P
24.3 37/50 25.4 #54 LP16 1.0
2.2 mm
2.2 mm
G20
G20/G25
G20
G20/G25
20
20/25
2.0
2.0/2.3
2.5/2.9
2.5
YES
Nat 23.8 10 N22
Governor
Gas
Appliance
Category
Gross
Input (kW)
20.5
YES
N2210.818.5
YES
YES
26.4
40AV
70AV
Applicable
Countries
Nat
20
20/25
Nominal Gas
Rate (m3/hr)
Model
Fuel Type
Net
Input (kW)
Supply
Pressure (mbar)
Burner
Pressure (mbar)
Burner
Orifice
Pilot
Orifice (code)
Model Fuel Type
Gross
Input
BTUs (kW)
Net Input
kW
Supply
Pressure
(mbar)
Burner
Pressure
(mbar)
Burner
Orifice
Pilot
Orifice
(code)
Natural 18.5 7" W.C. (17.4) 4" W.C. (10) 2.2 mm N22
Propane 18.9 11" W.C. (27.4) 10 W.C. (25) #54 LP16
Natural 25.0 7" W.C. (17.4) 4" W.C. (10) #43 N22
Propane 25.8 11" W.C. (27.4) 10 W.C. (25) 1.45 LP16
Natural 67 Mj/h 1.74 kPa 1.0 kPa 2.2 mm 0.56 mm (N22)
ULPG 68 Mj/h 2.74 kPa 2.5 kPa 1.40 mm (#54) 0.41 mm (LP16)
Natural 86 Mj/h 1.74 kPa 1.0 kPa 2.2 mm 0.56 mm (N22)
ULPG 88 Mj/h 2.74 kPa 2.5 kPa 1.40 mm (#54) 0.41 mm (LP16)
40AV
70AV 96 Mj/h
AUSTRALIAN
GAS TABLE
NON CE
GAS TABLE
40AV 70,000 (20.5)
95,000 (27.8)70AV
74 Mj/h
Netherlands Only - Natural Gas
This unit has been set for the appliance category K (I2K) and is suitable for the use of G and G+
gas distribution according to the specifications as shown in the NTA 8837: 2012 Annex D with a
Wobbe index from 43.46 to 45.3 MJ/m3 (dry, 0°C, above value) or from 41.23 to 42.98 (dry, 15°C,
upper value). This unit can also be converted and / or adjusted again for the appliance
category E (I2E) This therefore means that the device "is suitable for G+ gas and H-gas, it is
demonstrably suited for G+ gas and demonstrable is suitable to H-gas "within the meaning of the
"Decision of Ma
10, 2016 amendin
the Decree on
as a
liances ...."