Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and
workmanship for one year from the date of purchase. This warranty
does not cover fuses, disposable batteries or damage from accident,
neglect, misuse, alteration, contamination, or abnormal conditions
of operation or handling. Resellers are not authorized to extend
any other warranty on Amprobe’s behalf. To obtain service during
the warranty period, return the product with proof of purchase to
an authorized Amprobe Test Tools Service Center or to an Amprobe
dealer or distributor. See Repair Section for details. THIS WARRANTY
IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EX-
PRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES
OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE
HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR
ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states
or countries do not allow the exclusion or limitation of an implied
warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Introduction
Thank you for purchasing an Amprobe Tic Tracer. You now own one
of the nest electrical safety tools available. This manual covers three
models with varying features. Basic operation of each is the same; dif-
ferences are described within this User Manual text.
Please read this manual carefully before using your new Tic Tracer
product, as it contains Important Safety information. If you have any
questions, please call our toll free Customer Service line at
1-877-AMPROBE (267-7623)
AC Voltage Detector
CONTENTS
Symbols............................................................................................1
Features...........................................................................................2
Parts and Controls............................................................................2
Precautions and Warnings..............................................................3
Operating Instructions.....................................................................3
TIC 300CC Additional Tests.............................................................4
Applications......................................................................................5
Maintenance.....................................................................................8
Specications....................................................................................8
Warranty..........................................................................................8
SYMBOLS
Mine Safety and
Health Adminstration
v
Refer To Manual
1
United States Department of Labor
Mine Safety and Health Adminstration
TIC TRACER
1
2
3
1
2
3
6
TIC TRACER
5
FEATURES
TIC 300CC, TIC 300HV
• Detects AC voltage without connection
• Audible signal
• Lightweight yet rugged
• Integrated switchguard
• Handheld
• 9VDC Battery
• Locates breaks in insulated wire
• Checks fuses and breaker panels
• Checks for proper grounding
• Made in USA
• One Year Warranty
Additional TIC 300CC Features:
• Continuity checks
• Capacitor Checks
Additional TIC 300HV Features:
• High and Low ranges
• Visual Indicator
• Adaptable to Hot Stick
PARTS AND CONTROLS
1. Power Switch
2. Speaker
3. Sensing probe
4. TIC 300CC Only- Test lead connex (on back)
5. TIC 300HV Only- Visual Indicator
6. TIC 300HV Only- Hot Stick adapter connection
2
PRECAUTIONS & WARNINGS
Safety Information
v CAUTION!
This tester should only be used by qualied personnel.
Always use appropriate Safety attire and equipment.
If the unit is dropped, damaged or for any reason you suspect its op-
eration, test it on a known AC source or energized uorescent lamp
before making ANY high voltage tests.
v WARNING!
3 Phase feeder cables with conductors close together may self-cancel
the electric eld and not be detected by your TIC Tracer.
Verify the phase conductors are separated by at least 5” (13cm) be-
fore testing for AC voltage.
When approaching an unknown high voltage, always start with the
unit switched to the Low range. Then approach the voltage from a
safe distance.
v TIC 300HV
When approaching an unknown high voltage, always start with the
unit switched to the Low range. Then approach the voltage from a
safe distance.
For 3 phase voltages above 1500 V, the sensor will not be able to
detect a missing phase if the switch is set on the LOW range. Use the
HIGH range.
Do not let the unit make contact with a live line with voltage greater
than 20 kV.
Use a “Hot Stick” at all times on voltages above 1500VAC.
OPERATING INSTRUCTIONS
Before operating, the 9V battery must be installed as described in the
Maintenance section.
Voltage Detection
1. Turn unit on by sliding the power switch down to the ON
position. TIC 300HV- Slide the switch down to the LOW
position
3
2. An approximately once per second “beep” will be heard,
indication the unit is on and operating. TIC 300HV- The LED
visual indicator will ash in concert with the “beep” rate.
3. Approach a uorescent lamp, or known AC conductor, to
ensure the tool is working properly.
4. Place the tip of the probe on or near the circuit to be tested.
If voltage is present, the “beep” rate will increase to a rapid
beep or siren.
The slower the beep rate, the lower the voltage. If no increase
in “beep” rate is heard, AC voltage is not present.
TIC 300HV- When probing for voltage higher than 1500 VAC
use proper safety equipment and, after determining the
existence of voltage in the Low range, switch to the High range.
TIC 300CC ADDITIONAL TESTS
To Check Circuit Continuity
1. Attach the included test leads to the input jack on the
bottom of the back side of the unit.
2. Switch the unit on and verify the normal, once per
second “beep”.
3. Clip the test leads together and verify that a steady siren, or
whistle, occurs. The TIC 300CC checks continuity up to 1M .
4. Connect the clip leads to the circuit to be tested. A steady
siren, or whistle indicates continuity: a normal “beep” rate
indicates open circuit.
To Check High Value Capacitors
1. De-energize the circuit containing the capacitor to be tested.
2. Attach the test clip harness to the jack on the bottom of the
back side of the unit.
3. With the unit switched OFF, disconnect one lead of the
capacitor and connect the test clips to both leads of the capacitor.
4. Switch to ON-
Capacitor is Good- rst a constant beep tone, then slow
“beeps”. The duration of the whistle in seconds is proportional
to the capacitance in the microfarads (µF).
4
Capacitor is Shorted or Leaky- continuous whistle, as if the
leads were touched together.
Capacitor is Open- steady slow “beeps” only.
To Check Low Value Capacitors
1. De-energize the circuit containing the capacitor to be tested.
2. Attach the test clip harness to the jack on the bottom of the
back side of the unit.
3. Switch the unit ON and disconnect one lead of the capacitor,
then connect one test clip to the capacitor.
4.Touch the other test clip to the remaining lead of the capacitor”
Capacitor is Shorted or Leaky- continuous whistle, as if the
leads were touched together.
Capacitor is Open- steady slow “beeps” only.
To Test Diodes
1. Attach the test clip harness to the jack on the bottom of the
back side of the unit.
2. Connect the test clips across the diode, note the signal, and
reverse the connection.
Diode is /good – a normal beep is heard during one
connection, a whistle in the other.
Diode is shorted – steady whistle during both connections.
Diode is open – normal beep during both connections.
APPLICATIONS
To Check Fuses and/or Breakers
You may check screw-in type, cartridge type or
resettable breaker type fuses with your Tic Tracer.
With the circuit energized, a good screw-in type fuse
will create a whistle when the probe is placed on it.
Good cartridge fuses and breakers should sound a
siren on both ends, and across their length. Note
that because the TicTracers detect the electrostatic
eld, it may be necessary to remove the metal fuse
panel cover, as it may act as a shield.
5
Quickly
check
circuit
breakers
To Locate heating wire within walls
Traces heating wires within plastered walls. A quickened
signal indicates an energized wire, if it ceases, a
break is located.
To locate breaks in insulated wire and
heating elements
Energize the wire or element and trace along it
until the quickened “beep” or siren ceases. This
indicates the point of the break, or “open”.
Safety check on power tools and appliances
While the device is connected to an AC voltage,
touch the probe tip to the metal casing. Test
with your power tool device switched off and
on. No increase in beep rate indicates a safely
grounded tool or appliance. This test will not
work on power tools with plastic cases.
Outlets and Switches
Place probe tip against an outlet or switch contact,
increase beeping indicates voltage.
Loadbreak connectors
Check for power at high voltage transformers at
elbow test point.
Transmission Lines
Determine which conductor carries power and if
ground cables carry high static charge.
TV High voltage
Check picture tube
and HV transformer.
TIC 300HV High
voltage applications
With the unit
switched in the High
range, the
instrument will
detect voltages
above 1500V.
Always use a Hot
Stick, model TIC 410A,
in these applications.
6
Safely and quickly
check for voltage
at ac outlet
AC Voltage detection without connections
Senses voltage electrostatically without wire contact.
The necessary tool for everyone involved with
electrical systems.
Easily check
power tools
for proper
groundings
Easily detect
breaks in
live wires
7
Check
diodes
Check
capacitors
Check continuity
in resistors
Safely and
quickly
check for
voltage at
receptacles
Quickly check
relays for open
windings
Check for
continuity in
transformer
wirings
Check
cartridge
fuses safely
and quickly
Check
transistors
AC Voltage detection without connections
Senses voltage electrostatically without wire contact.
The necessary tool for everyone involved with
electrical systems.
MAINTENANCE
No normal maintenance apart from battery replacement is necessary
with your Amprobe Tic Tracer. Replace the battery when no signal is
heard when the instrument is switched ON.
Battery Replacement
1. Slide the small latch on the top of the battery compartment
downward.
2. Tilt out and remove the battery cover.
3. If applicable, disconnect old battery from the connector.
4. Connect a new, and/or tested, 9V battery to the connector,
and replace in compartment.
5. Replace cover and move latch upwards to secure.
SPECIFICATIONS
Power Supply: 9 VDC battery
Voltage Detection Range:
TIC 300CC 30 to 1500 VAC
TIC 300HV Low – 30 to 1500 VAC
High – 1500 to 122,000 VAC *
*Use only with proper safety equipment and Hot Stick Amprobe
Model TIC 410A for voltages up to 122kV.
Operating Temperature Range: 32°F to 125°F (0°C to 52°C)
Battery Life: Approximate Battery shelf life
Duty Cycle: Continuous
Response Time: Instantaneous
Dimensions: 8.5 x 2.8 x 1 inches (21.6 x 7 x 2.5 cm)
Weight: 5 ounces (140 gr)
8
WARRANTY
Repair
All test tools returned for warranty or non-warranty repair or for
calibration should be accompanied by the following: your name,
company’s name, address, telephone number, and proof of purchase.
Additionally, please include a brief description of the problem or the
service requested and include the test leads with the meter. Non-war-
ranty repair or replacement charges should be remitted in the form of
a check, a money order, credit card with expiration date, or a purchase
order made payable to Amprobe® Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before
requesting repair. During the warranty period any defective test
tool can be returned to your Amprobe® Test Tools distributor for an
exchange for the same or like product. Please check the “Where to
Buy” section on www.amprobe.com for a list of distributors near you.
Additionally, in the United States and Canada In-Warranty repair and
replacement units can also be sent to a Amprobe® Test Tools Service
Center (see below for address).
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a
Amprobe® Test Tools Service Center. Call Amprobe® Test Tools or inquire
at your point of purchase for current repair and replacement rates.
In USA In Canada
Amprobe® Test Tools Amprobe® Test Tools
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 888-993-5853 Tel: 905-890-7600
Fax: 425-446-6390 Fax: 905-890-6866
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe® Test
Tools distributor for a nominal charge. Please check the “Where to
Buy” section on www.amprobe.com for a list of distributors near you.
European Correspondence Address*
Amprobe® Test Tools Europe
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
*(Correspondence only – no repair or replacement available from this address.
European customers please contact your distributor).
9
TIC TRACERS
AC Voltage Detectors
User Manual
• Mode d’emploi
• Manuale d’Uso
• Bedienungshandbuch
• Manual de uso
• Användarhanbok
(French)
Français
Détecteur de tensions alternatives
TABLE DES MATIERES
Symboles..........................................................................................1
Fonctionnalités.................................................................................2
Composants et commandes.............................................................2
Précautions et mises en garde.........................................................3
Consignes d’utilisation....................................................................3
Autres tests du TIC 300CC...............................................................4
Applications......................................................................................5
Entretien..........................................................................................8
Caractéristiques................................................................................8
Garantie...........................................................................................8
SYMBOLES
Mine Safety and
Health Adminstration
v
Se reporter au manuel
1
United States Department of Labor
Mine Safety and Health Adminstration
Rivelatore di tensione c.a.
INDICE
Simboli.............................................................................................1
Caratteristiche..................................................................................2
Componenti e comandi...................................................................2
Precauzioni e avvertenze..................................................................3
Istruzioni per l’uso...........................................................................3
Altri test eseguibili con il TIC 300CC..............................................4
Applicazioni......................................................................................5
Manutenzione..................................................................................8
Dati tecnici........................................................................................8
Garanzia..........................................................................................8
SIMBOLI
Mine Safety and
Health Adminstration
v
Consultare il manuale
1
United States Department of Labor
Mine Safety and Health Adminstration
TIC TRACERS
AC Voltage Detectors
User Manual
• Mode d’emploi
• Manuale d’Uso
• Bedienungshandbuch
• Manual de uso
• Användarhanbok
(German)
Deutsch
Wechselspannungsprüfer
INHALT
Symbole...........................................................................................1
Merkmale..........................................................................................2
Teile und Bedienelemente...............................................................2
Vorsichts- und Warnhinweise...........................................................3
Betriebsanweisungen......................................................................3
TIC 300CC Zusätzliche Tests............................................................4
Anwendungen..................................................................................5
Wartung...........................................................................................8
Technische Daten.............................................................................8
Garantie...........................................................................................8
SYMBOLE
Mine Safety and
Health Adminstration
v
Siehe Handbuch
1
United States Department of Labor
Mine Safety and Health Adminstration
TIC TRACERS
AC Voltage Detectors
User Manual
• Mode d’emploi
• Manuale d’Uso
• Bedienungshandbuch
• Manual de uso
• Användarhanbok
(Spanish)
Español
Detector de tensión de CA
ÍNDICE
Símbolos..........................................................................................1
Características...................................................................................2
Piezas y controles.............................................................................2
Precauciones y advertencias.............................................................3
Instrucciones de operación..............................................................3
Pruebas adicionales con el TIC 300CC............................................4
Aplicaciones......................................................................................5
Mantenimiento................................................................................8
Especicaciones................................................................................8
Garantía...........................................................................................8
SÍMBOLOS
Mine Safety and
Health Adminstration
v
Consultar el manual
1
United States Department of Labor
Mine Safety and Health Adminstration
AC Voltage Detector
INNEHÅLL
Symboler..........................................................................................1
Funktioner........................................................................................2
Delar och reglage............................................................................2
Försiktighetsåtgärder och varningar................................................3
Anvisningar.......................................................................................3
TIC 300CC - Ytterligare tester..........................................................4
Tillämpningar....................................................................................5
Underhåll.........................................................................................8
Specikationer..................................................................................8
Garanti.............................................................................................8
SYMBOLER
Mine Safety and
Health Adminstration
v
Se handboken
1
United States Department of Labor
Mine Safety and Health Adminstration
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Amprobe TIC300CC TIC-Tracer User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI