Lightolier CTS3-13 User manual

Category
Work lights
Type
User manual
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems CTS3-13
1BHFPG $FOUSBM5SPVHI4ZTUFN-JHIU51FS4FDUJPO
&
Ordering Information
Family Mounting Shielding Configuration Output Length (nom.) Housing Voltage Option
CT3
G
L
A
CT3 G(SJE.PVOU L 'MVTI A = 1 Lamp
1
H = High 2GPPU U = Indiv. Unit
2
1 = 120V E&.1BDL
Lens 0VUQVU 4GPPU S = Starter
3
2 = 277V T = Tandem Switch
S = Standard 8GPPU J = Joiner 45ISPVHI8JSFT
T = Telescoping
55ISPVHI8JSFT
3
5
6
7
1
2
4
5
1
/
8
" (13.02cm)
3" (7.62cm)
3
3
/
4
"
(9.53cm)
$PNQMFUFPSEFSJOHJOTUSVDUJPOTCFMPX
Features
1. Housing: HBVHFQSFQBJOUFETUFFM
2. Bulkhead: HBVHFHBMWBOJ[FETUFFM
3. Reflector:TFNJTQFDVMBSBMVNJOVN
4. Trim:OPOFWJTJCMFGJYUVSFESPQTJOUPHSJETZTUFNCZPUIFST
5. Ballast: program start electronic
6. Lamp: 5PS5)0GMVPSFTDFOU
7. Lens:FYUSVEFEGSPTUFEBDSZMJD
 0QUJPOBM&YUFOEFE$POUJOVPVT-FOHUI-FOTTIPXOPOQBHF
Mounting
)PVTJOHJTTVTQFOEFECZIBOHFSXJSFTCZPUIFST$PNQBUJCMFXJUITUBOEBSEBOE
TMPU5HSJETZTUFNT0QUJPOBMGBDUPSZQSPWJEFE2VJDL%SBX*OTUBMMBUJPO4ZTUFN
shown on page 2.
Electrical
Electronic Ballast:1SPHSBNNFETUBSUDPOEVDUPSHBVHFXJSF
$PMPSDPEFERVJDLDPOOFDUPSTBMMPXFBTZDPOOFDUJPOGPSNPEVMBSGJYUVSFT'BDUPSZ
JOTUBMMFECBMMBTUEJTDPOOFDUBMMPXTUIFCBMMBTUUPCFEJTDPOOFDUFEGSPNBOE
SFDPOOFDUFEUPJODPNJOHQPXFSVOEFSMPBEXJUIPVUUVSOJOHUIFFOUJSFDJSDVJUPGG
Emergency Battery Pack:-VNFOT!NJOJNVN
Labels
UL, cUL and IBEW
Ordering Instructions
Individual Fixtures:
1. 0SEFSOVNCFSPG*/%*7*%6"-6/*54SFRVJSFE
Continuous Rows:
1. %FUFSNJOFSVOMFOHUI
2. 0SEFSPOF4UBSUFSGJYUVSF
3. 0SEFSPOF5FMFTDPQJOHGJYUVSF
4. 0SEFSSFNBJOEFSPG+PJOFSGJYUVSFT
'PSCFTUPOFMBNQFGGFDUVTF5FMFTDPQJOHGJYUVSFBUMPOHFTUMFOHUIQPTTJCMF
$POUJOVPVTSVOTPOMZ1SJPSUPJOTUBMMJOH$54JOBHSJEDFJMJOHUIFJOTUBMMJOH
DPOUSBDUPSNVTUFOTVSFUIBUUIFGJYUVSFXJMMTFUJOUPUXPNBJOSVOOFSTTQBDFE
DNPODFOUFS/PHSJEDSPTTNFNCFSTBSFSFRVJSFEFYDFQUBUUIFCFHJOOJOH
BOEFOEPGUIFSVO
1
-BNQJTNPVOUFEEJBHPOBMMZBOEFYUFOETJOUPBEKBDFOUGJYUVSFCZDNJO4UBSUFS+PJOFSBOE5FMFTDPQJOHGJYUVSFT
2
GPPU*OEJWJEVBM6OJUOPUBWBJMBCMFJO(SJE.PVOU
3
4UBSUFSBWBJMBCMFBTGPPUBOEGPPUPOMZ
5FMFTDPQJOHGJYUVSFTIJQTDNBEKVTUBCMFEPXOUPDN
&.QBDLOPUBWBJMBCMFJOGPPUPS5FMFTDPQJOHGJYUVSFT
Job Information Type:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems CTS3-13
1BHFPG $FOUSBM5SPVHI4ZTUFN-JHIU51FS4FDUJPO
&
Performance & Quick Calculators
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARELAMP % LUMINAIRE
   
   
   
Report No: *5-
Cat No: $5(-")6
Efficiency: 
Lamps: '28)0
"NBMHBN-BNQ
Lumens: 
Candlepower
%&(









    
    
     
     
     
     
     
     
     
     

    
'MPPS$BWJUZ3FGMFDUBODF
Coefficients of Utilization
&GGFDUJWF$FJMJOH$BWJUZ3FGMFDUBODF
  
8"--3&'-&$5"/$&
        
         
        
        
         
        
         
         
         
         
         
        
Room Cavity Ratio
810
608
405
203
0
10
20
30
40
50
60
70
80
90
90°
Accessories
Building Structure
Tooless Loop
Connector
Reverse
Cable Gripper
CTS3 Housing
Ceiling
Draw Luminaries To Ceiling
CTS3L144
&YUFOEFE$POUJOVPVT-FOHUI-FOTDN
Order necessary quantity to reduce lens joints in
continuous runs.
Sample Runs
2' Individual
24"
(60.96cm)
4' Individual
48" (121.92 cm)
8' Start 8' Joiner 8' Telescoping*
29' (883.92cm)
2' Joiner
85.5" (217.17cm)
82" (208.28cm)
8' Joiner
82" (208.28cm)
17" (43.18cm)
81.5" (207.01cm)
24' (731.52cm)
8' Start 8' Joiner 4' Joiner 8' Telescoping*
85.5" (217.17cm)
82" (208.28cm)
41" (104.14cm)
79.5" (201.93cm)
22' (670.56cm)
8' Start 8' Joiner 2' Joiner 8' Telescoping*
85.5" (217.17cm)
82" (208.28cm)
17" (43.18cm)
79.5" (201.93cm)
19' (579.12cm)
8' Start 8' Telescoping*
17"
(43.18cm)
2' Joiner
85.5" (217.17cm) 41"
(104.14cm)
4' Joiner
84.5" (214.63cm)
17' (518.16cm)
8' Start 4' Joiner 8' Telescoping*
85.5" (217.17cm)
41" (104.14cm)
77.5" (196.85cm)
12' (365.76cm)
8' Telescoping*
44.5"
(113.03cm)
4' Start
17"
(43.18cm)
2' Joiner
82.5" (209.55cm)
10' (304.80 cm)
4' Start 8' Telescoping*
44.5" (113.03cm)
75.5" (191.77cm)
29'
(8.84m)
24'
(7.32m)
22'
(6.71m)
19'
(5.79m)
17'
(5.18m)
12'
(3.66m)
10'
(3.05m)
* Telescoping fixture ranges from 85-3/8" (216.85cm) to 49-3/8" (125.41cm).
'PSCFTUPOFMBNQFGGFDUVTF5FMFTDPQJOHGJYUVSFJOMPOHFTUMFOHUIQPTTJCMF
;0/&    
CTS3C120
2VJDL%SBX*OTUBMMBUJPO
4ZTUFNDN
$BCMF4FUPG
'PSTVTQFOEJOHGSPN
TUSVDUVSFBCPWF
Order one CTS3C120 per
fixture.
$POTVMUGBDUPSZGPSTQFDJGJD
application.
  • Page 1 1
  • Page 2 2

Lightolier CTS3-13 User manual

Category
Work lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI