Duracell Ultra CR2 User manual

Category
Non-rechargeable batteries
Type
User manual

This manual is also suitable for

Lithium/Manganese Dioxide
Ultra CR2
Li/MnO2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
**
6/08
Nominal Voltage:
3.0 V
Typical Voltage:
3.2-3.3 V
Nominal Internal
Impedance:
0.3 ohm @ 1kHz
Average Weight: 11 g
Volume: 5.168 cm.
3
Terminals:
Flat, Recessed Negative
Terminal, Nickel Plated Steel
Operating Temp.
Range:
-20°C to 75°C (-4°F to
167°F)
NEDA/ANSI: CR2
IEC: -
**
1/06
Duracell Ultra CR2 Typical Performance
0 400 800 1200
Pulse Cycles
Photo
35mm SLR Photo
35mm Point &
Shoot Camera
1.2A, 3 sec on 7sec off, cont.
to 1.8 V @ 20°C
1.8A, 3 sec on 7sec off, cont.
to 1.8 V @ 20°C
0.9A, 3 sec on 27sec off, cont.
to 1.8 V @ 20°C
Dimensions shown are ANSI standards
(–)
(+)
0.7 mm
Min
27.0 mm
Max
15.6 mm
15.1
φ
6.5 mm
Max
φ
Delivered Energy vs. Power Drain
@ Various Cutoff Voltage - Room Temperature
0.1
1
3
411.0
Power (W)
Energy (Wh)
1.8 V
2.0 V
2.2 V
6/08
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
**
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park
Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
Li/MnO2
Lithium/Manganese Dioxide
Ultra CR2
0.9 Amp, 3 sec on/27 sec off
@ Various Temperatures
1.5
1.9
2.3
2.7
00210080040
Pulses
Battery Voltage (V)
RT
1.2 Amp, 3 sec on/ 7 sec off
@ Various Temperatures
1.5
1.9
2.3
2.7
0080060040020
Pulses
Battery Voltage (V)
RT
1.8 Amp 3 sec on/ 7 sec off
@ Various Temperatures
1.5
1.9
2.3
2.7
0 100 200 300 400 500
Pulses
Service Hours (V)
RT
-10C
-10C
-10C
- 20C
- 20C
Continuous Discharge RT to 1.7 Volts
1
2
3
4
0020010111.0
Service (Hours)
Voltage (V)
10 mA
50 mA
100 mA
250 mA
500 mA
750 mA
1000 mA
  • Page 1 1