GE Appliances GFD55ESSNWW Installation guide

Type
Installation guide
- Fire Hazard
WARNING
Clothes dryer installation must be performed by a
qualified installer.
Install the clothes dryer according to these instructions
and local codes.
DO NOT install a clothes dryer with flexible plastic venting
materials. If flexible metal (semi-rigid or foil-type) duct is
installed, it must be UL-listed and installed in accordance
with the instructions found in “Connecting the Dryer
to House Vent” later in this manual. Flexible venting
materials are known to collapse, be easily crushed and
trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
DO NOT install or store this appliance in any location
where it could be exposed to water or weather.
To reduce the risk of severe injury or death, follow all
installation instructions.
Save these instructions. (Installers: Be sure to leave
these instructions with the customer.)
In the Commonwealth of Massachusetts,
the following installation instructions apply:
Installation must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified
or licensed by the State.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not
exceed 4 feet.
FOR GAS DRYERS ONLY
Dryers
04
Installation
Instructions
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT Save these instructions for local electrical
inspector’s use.
IMPORTANT
Observe all governing codes and
ordinances.
Install the clothes dryer according to the manufacturer’s
instructions and local codes.
Note to Installer Be sure to leave these instructions
with the Consumer.
Note to Consumer Keep these instructions for future
reference.
Clothes dryer installation must be performed by a qualified
installer.
This dryer must be exhausted to the outdoors.
Before the old dryer is removed from service or discarded,
remove the dryer door.
Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance
is used near children.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
Install the dryer where the temperature is above 50°F for
satisfactory operation of the dryer control system.
Remove and discard existing plastic or metal foil duct
and replace with UL-listed duct.
Service information and the wiring diagram are located
in the control console.
31-16769-5 08-18 GEA
234D2274P004
See your Owner’s Manual for details on how to contact us regarding installation questions
Installation Instructions
2
Tilt the dryer sideways and remove the foam
shipping pads by pulling at the sides and breaking
them away from the dryer legs. Be sure to remove
all of the foam pieces around the legs.
Remove the bag containing the literature.
UNPACKING YOUR DRYER
ROUGH-IN DIMENSIONS
With Pedestal: 52 3/8” (133 cm)
Stacked: 84” (213.36 cm) - 7.5 cu. ft. models
79 5/8” (202.25 cm) - 7.0 cu. ft. models
NOTE: Dryer height can be adjusted to match washer height.
GE Appliances strongly recommends the use of factory
specified parts. These hoses are manufactured and tested
to meet GE Appliances specifications.
GE Appliances strongly recommends the use of new water
supply hoses. Hoses degrade over time and need to be
replaced every 5
years to reduce the risk of hose failures
and water damage.
Parts and Accessories
Order on-line at GEApplianceparts.com, 24 hours a day
or by phone at 877.959.8688 during normal business hours.
STEAM WATER HOSES (for steam dryer models only):
ACCESSORIES:
Order on-line at GEApplianceparts.com, 24 hours a day or
by phone at 877.959.8688 during normal business hours.
Part Number Accessory
SBSD137HWW
27” width White Pedestal
SBSC137HDG
27” width Diamond Gray Pedestal
GEFLSTACK Stacking Kit for Dryer over Washer
PM08X10085
Flexible Metal Dryer Transition Duct
WE01X20677
Clothes Dryer Shoe Rack
Part Number Accessory
WE25X20060
Complete Kit (hoses, Y-adapter, washers)
or
WE49X25794
Kit (Short hose, Y-adapter, washers)
and
WE1M847 Long Hose
OR SEPARATELY
WE1M847 Long Hose and
WE1M848 Short Hose
4 3/8”
(11.11 cm)
Side View
X
39 3/8”
(100 cm)
27”
(68.6 cm)
39 3/8”
(100 cm)
Front View
X
32 3/16” (81.76 cm)
7.0 cu. ft.
models
33” (83.80 cm)
7.5 cu. ft.
models
Y
4 1/2” (11.43 cm)
7.0 cu. ft.
models
5 3/8” (13.65 cm)
7.5 cu. ft.
models
Y
Installation Instructions
MOBILE OR MANUFACTURED
HOME INSTALLATION
Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION AND SAFETY
STANDARD, TITLE 24, PART 3280 or STANDARD
FOR MOBILE HOMES CAN/CSA-Z240 MH, or,
when such standards are not applicable, with
AMERICAN NATIONAL STANDARD FOR MOBILE
HOME, ANSI/NFPA NO. 501B.
The dryer MUST be vented to the outdoors.
The exhaust vent MUST be securely fastened to a
non-combustible portion of the mobile home.
The vent MUST NOT be terminated beneath a
mobile or manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other
duct, vent or chimney.
DO NOT use sheet metal screws or other
fastening devices which extend into the interior of
the exhaust vent.
Provide an opening with a free area of at least 25
square inches for introduction of outside air into
the dryer room.
See the sections for electrical connection information.
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18” (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
The dryer MUST be vented to the outdoors.
Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” either side
1” rear
1” front
1” top
Consideration must be given to provide adequate
clearance for installation and service.
Closet doors must be louvered or otherwise ventilated
and have at least 60 square inches of open area. If
the closet contains both a washer and a dryer, doors
must contain a minimum of 120 square inches of
open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, THE CONFIGURATION
OF THE DUCTING MAY REQUIRE GREATER THAN
1” OF REAR CLEARANCE.
Gas Dryers Only:
No other fuel burning appliance shall be installed in
the same closet as a gas dryer.
The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than ½ psi (3.5 kPa).
A 1/8 inch NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer.
- Explosion Hazard
WARNING
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: 0” both sides, 1” rear and 1” top.
Consideration must be given to provide adequate
clearance for installation and service.
3
Installation Instructions
4
CONNECTING INLET HOSES (for steam dryer models only)
CONNECTING INLET HOSES (cont.)
7. Using pliers, tighten all the couplings with an
additional two–thirds turn.
NOTE: Do not overtighten. Damage to the
couplings may result.
8. Turn the water faucet on.
9. Check for leaks around the ‘’Y’’ connector,
faucet and hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed
within 42 in. (107 cm) of your washer’s water
inlet. The faucets MUST be 3/4 in. (1.9 cm)
garden hose-type so inlet hoses can be
connected. Water pressure MUST be between
10 and 120 pounds per square inch. Your
water department can advise you of your water
pressure.
NOTE: A water softener is recommended
to reduce buildup of scale inside the steam
generator if the home water supply is very hard.
To produce steam, the dryer must connect to
the cold water supply. Since the washer must
also connect to the cold water, a “Y” connector
is inserted to allow both inlet hoses to make that
connection at the same time.
NOTE: Use new inlet hoses; never use old
hoses.
1. Turn the cold water faucet off. Remove the
washer inlet hose from the washer fill valve
connector (cold).
2. Ensure the rubber flat washer is in place and
attach one female coupling of the short hose
provided onto the washer fill valve connector.
Tighten by hand until firmly seated.
3. Attach one male end of the “Y” connector to
the other female coupling of the short hose.
Ensure the rubber flat washer is in place.
Tighten by hand until firmly seated.
4. Insert the filter screen in the coupling of the
washer’s inlet hose. If a rubber flat washer is
already in place remove it before installing the
filter screen. Attach this coupling to one male
end of the ‘’Y’’ connector. Tighten by hand until
firmly seated.
5. Ensure the rubber flat washer is in place and
attach a 4 ft. to 6 ft. long water inlet hose (may
need to be purchased separately) to one male
end of the ‘’Y’’ connector. Tighten by hand until
firmly seated.
6. Ensure the rubber flat washer is in place and
attach the other end of the dryer’s long inlet
hose to the fill valve connector at the bottom
of the dryer back panel. Tighten by hand until
firmly seated.
CONNECTING INLET HOSES
5
Installation Instructions
CONNECTING A GAS DRYER (skip for electric dryers)
Before beginning the installation, turn off the circuit
breaker(s) or remove the dryer’s circuit fuse(s) at
the electrical box. Be sure the dryer
cord is unplugged from the wall.
Turn the dryer’s gas shut-off valve in the supply line
to the OFF position.
Disconnect and discard old flexible gas connector
and ducting material.
Shut-off
Valve
MATERIALS YOU WILL NEED
Ŷ
4” dia. metal elbow
Ŷ
Pipe compound or
PTFE tape
Ŷ
Flexible gas line
connector
Ŷ
Duct clamps (2) or
Spring clamps (2)
Ŷ
Safety glasses
Ŷ
4” dia. metal duct
(recommended)
Ŷ
Gloves
Ŷ
Soap solution for
leak detection
Ŷ
Exhaust hood
Ŷ
Duct tape
Ŷ
Gas pipe adapters (2),
elbow and pipe plug
TOOLS YOU WILL NEED
Ŷ
10” Adjustable
wrenches (2)
Ŷ
8” Pipe wrench
Ŷ
Flat-blade
screwdriver
Ŷ
Level
Ŷ
Slip-joint pliers
Ŷ
4” dia., UL-listed
flexible metal duct
(if needed)
Ŷ
4” Cover Plate
(Kit WE49X22606)
(if needed)
6
Installation Instructions
GAS REQUIREMENTS
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
A 1/8” National Pipe Taper thread plugged
tapping, accessible for test gauge connection,
must be installed immediately upstream of the
gas supply connection to the dryer. Contact your
local gas utility should you have questions on the
installation of the plugged tapping.
Supply line is to be 1/2” rigid pipe and equipped
with an accessible shutoff within 6 feet of, and in
the same room with, the dryer.
Use pipe thread compound appropriate for
natural or LP gas or use PTFE tape.
Connect flexible metal connector to dryer and
gas supply.
ADJUSTING FOR ELEVATION
Gas clothes dryers input ratings are based on
sea level operation and need not be adjusted
for operation at or below 2000 ft. elevation. For
operation at elevations above 2000 ft., input
ratings should be reduced at a rate of 4 percent
for each 1000 ft. above sea level.
Installation must conform to local codes and
ordinances or, in their absence, the NATIONAL
FUEL GAS CODE, ANSI Z223.
You must use with this dryer a flexible metal connector
(listed connector ANSI Z21.24 / CSA 6.10). The length
of the connect shall not exceed 4 ft.
Use a new CSA International approved flexible
gas supply line. Never reuse old flexible
connectors.
Install an individual manual shut-off valve
within 6ft. of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54.
Securely tighten all gas connections.
If connected to LP gas, have a qualified
person make sure gas pressure DOES NOT
exceed 13” water column.
Examples of a qualified person include:
licensed heating personnel, authorized gas
company personnel, and authorized service
personnel.
Failure to do so can result in death,
explosion, or fire.
The installation must conform with local
codes, or in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1.
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used
only with a natural gas supply. A manufacturer-
supplied conversion kit is required to convert this
dryer for propane gas supply. Use propane
gas
conversion kit WE25X217
. Conversion must be
made by properly trained and qualified personnel
in accordance with local codes and ordinances.
- Fire Hazard
WARNING
- Explosion Hazard
WARNING
CONNECTING A GAS DRYER (cont.)
2"
2-5/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
7
Installation Instructions
CONNECTING A GAS DRYER (cont.)
Install a 1/8” NPT plugged tapping to the
dryer gas line shut-off valve for checking gas
inlet pressure.
Install a flare union adapter to the plugged
tapping.
NOTE: Apply pipe compound or PTFE tape
to the threads of the adapter and plugged
tapping.
Attach the flexible metal gas line connector to
the adapter.
B
Tighten the flexible gas line connection, using
two adjustable wrenches.
C
D
Tighten all connections, using two adjustable
wrenches. Do not overtighten.
E
CONNECTING THE DRYER TO
THE GAS SUPPLY (cont.)
Open the gas shut-off valve.
F
Apply pipe compound
or PTFE tape to all
male threads.
Shut-Off
Valve
Plugged
Tapping
CONNECTING THE DRYER TO
THE GAS SUPPLY
Install a female 3/8” NPT elbow at the end of
the dryer gas inlet.
Install a 3/8” flare union adapter to the female
elbow.
IMPORTANT: Use a pipe wrench to securely
hold on to the end of the dryer gas inlet to
prevent twisting the inlet.
NOTE: Apply pipe compound or PTFE tape to
the threads of the adapter and dryer gas inlet.
A
Apply pipe compound to the
adapter and dryer gas inlet.
Tighten the flexible
gas line using two
adjustable wrenches.
Elbow
Adapter
Items not supplied
Adapter
1/8” NPT
Pipe Plug for
Checking Gas
Inlet Pressure
Shut-Off Valve
Pipe size at
least 1/2”
3/8” NPT
New Metal
Flexible Gas
Line Connector
8
Installation Instructions
TEST FOR LEAKS
Never use an open flame to test for gas leaks.
Check all connections for leaks with soapy solution or
equivalent.
Apply a soap solution. The leak test solution must not
contain ammonia, which could cause damage to the
brass fittings.
If leaks are found, close the valve, retighten the joint
and repeat the soap test.
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
(cont.)
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
Plug into a grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to do so can result in death, fire or
electrical shock.
Circuit – Individual properly polarized and grounded
15 or 20 amp circuit breaker or time-delay fuse.
Power Supply 2-wire plus ground, 120 Volt, single
phase, 60 Hz, alternating current.
Outlet Receptacle Properly grounded 3-prong
receptacle to be located
so the power cord is
accessible when the dryer
is in an installed position.
If a 2-prong receptacle is
present, it is the owner’s
responsibility to have a
licensed electrician replace
it with a properly grounded 3-prong grounding type
receptacle.
GROUNDING INSTRUCTIONS
This dryer must be grounded. In the event of a
malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of
least resistance for electric current. This dryer
uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is
properly installed and grounded in accordance
with all local codes and ordinances.
Improper connection of the
equipment-grounding conductor
can result in a risk of electric shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded. DO NOT modify
the plug on the power supply cord. If it will not
fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS
Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, with the latest edition of the
NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70 or CANADIAN ELECTRICAL CODE, CSA
C22.1. Check with a licensed electrician if you are
not sure that the dryer is properly grounded.
Open Gas
Valve
- Electrical Shock Hazard
WARNING
WARNING
Ensure proper
ground exists
before use.
If required by local codes, an external 18 gauge or
larger copper ground wire (not provided) may be
added. Attach to dryer cabinet with a #8-18 x ½”
sheet metal screw (available at any hardware store)
to rear of dryer as illustrated.
Ground
Screw
CONNECTING A GAS DRYER (cont.)
9
Installation Instructions
CONNECTING AN ELECTRIC DRYER
(Skip for gas dryers and if your dryer already has a power cord attached)
Before making the electrical connection, turn off
the circuit breaker(s) or remove the dryer’s circuit
fuse(s) at the electrical box. Be sure the dryer
cord is unplugged from the wall.
NEVER LEAVE
THE ACCESS COVER OFF THE TERMINAL
BLOCK.
MATERIALS YOU WILL NEED
Ŷ
4” dia. metal elbow
Ŷ
3/4” Strain relief
(UL recognized)
Ŷ
4” Duct clamps (2) or
4” spring clamps (2)
Ŷ
Safety glasses
Ŷ
4” dia. metal duct
(recommended)
Ŷ
Gloves
Ŷ
Exhaust hood
Ŷ
Duct tape
TOOLS YOU WILL NEED
Ŷ
Slip-joint pliers
Ŷ
Level
Ŷ
4” dia., UL-listed
flexible metal duct
(if needed)
Ŷ
Dryer power cord kit
(not provided with
dryer)
UL rated 120/240V,
30A with 3 or 4 prongs.
Identify the plug type
as per the house
receptacle before
purchasing line cord.
Ŷ
Flat-blade
screwdriver
Ŷ
Phillips
screwdriver
Ŷ
4” Cover Plate
(Kit WE49X22606)
(if needed)
POWER CORDS
GE Appliances strongly recommends the use of
factory specified parts. Select the power cord to fit your
installation requirements.
Order on-line at GEApplianceparts.com, 24 hours
a day or by phone at 877.959.8688 during normal
business hours.
Part Number Type Length Amperage
WX9X2 3-Prong 4 Feet 30
WX9X3 3-Prong 5 Feet 30
WX9X4 3-Prong 6 Feet 30
WX9X18 4-Prong 4 Feet 30
WX9X19 4-Prong 5 Feet 30
WX9X20 4-Prong 6 Feet 30
10
Installation Instructions
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC
DRYERS
Use a new UL-listed 240V 30 amp dryer power
supply cord with closed ring terminals or spade
terminals with upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining two supply wires to remaining
two terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical
shock.
For electrical connections using a
power cord:
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC
DRYERS
For direct wire connections:
Use 10 gauge solid copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining two supply wires to remaining
two terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical
shock.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This
dryer must be grounded. In the event of a
malfunction or breakdown, grounding will
reduce the risk of electric shock by providing
a path of least resistance for electric current.
This dryer uses a cord having an equipment-
grounding conductor and a grounding plug.
The plug must be plugged into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Improper connection of the
equipment-grounding conductor
can result in a risk of electric shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded. DO NOT modify
the plug on the power supply cord. If it will not
fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
For a permanently connected dryer: This
dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal on the appliance.
Improper connection of the
equipment-grounding conductor
can result in a risk of electric shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded.
SAVE THESE INSTRUCTIONS
- Fire Hazard
WARNING
- Fire Hazard
WARNING
WARNING
WARNING
CONNECTING AN ELECTRIC DRYER
11
Installation Instructions
CONNECTING DRYER USING
3-WIRE CONNECTION
CONNECTING AN ELECTRIC DRYER
3-wire Connection
NOT for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit
grounding through the neutral conduction.
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTE: Since January 1, 1996, the National Electrical
Code requires that new constructions use a 4-wire
connection to an electric dryer. A 4-wire cord must also
be used where local codes do not permit grounding
through the neutral.
3-wire connection is NOT for use on new construction.
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located at the lower
back.
4. Remove and discard ground strap. Keep the green
ground screw for Step 7.
5. Install 3/4 in. UL-recognized strain relief to power
cord entry hole. Bring power cord through strain
relief.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
7. Attach ground wire of power cord with the green
ground screw (hole above strain relief bracket).
Tighten all terminal block screws (3) securely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
NEVER LEAVE THE COVER OFF OF THE
TERMINAL BLOCK.
NEVER LEAVE THE COVER OFF OF THE
TERMINAL BLOCK.
L1
N
L2
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND
STRAP AND DISCARD.
KEEP GREEN
GROUND
SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
COVER
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located at the lower
back.
4. Install 3/4-in. UL-recognized strain relief to power
cord entry hole. Bring power cord through strain
relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral
(center) terminal of block and to green ground
screw on cabinet rear. Tighten all terminal block
screws (3) securely.
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
If required, by local code, install external ground
(not provided) to grounded metal, cold water
pipe, or other established ground determined by
a qualified electrician.
12
Installation Instructions
EXHAUSTING THE DRYER
TOOLS AND MATERIALS YOU WILL
NEED TO INSTALL EXHAUST DUCT
CONNECTING THE DRYER TO
HOUSE VENT
RIGID METAL TRANSITION DUCT
For best drying performance, a rigid metal transition
duct is recommended.
Rigid metal transition ducts reduce the risk of
crushing and kinking.
UL-LISTED FLEXIBLE METAL CLOTHES
DRYER TRANSITION DUCT
If rigid metal cannot be used, then UL-listed flexible
metal clothes dryer transition duct (GE Appliances
part PM08X10085) can be used.
Never install transition duct in walls, ceilings, floors
or other enclosed spaces.
Total length of transition duct should not exceed 8’
(2.4 m).
For many applications, installing elbows at both
the dryer and the wall is highly recommended (see
illustrations in next section). Elbows allow the dryer
to sit close to the wall without kinking and/or crushing
the transition duct, maximizing drying performance.
Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE)
TRANSITION DUCT
In special installations, it may be necessary to
connect the dryer to the home exhaust vent
using flexible metal (foil-type) transition duct. UL–
LISTED universal flexible dryer transition duct
(GE Appliances parts PM8X73 or WX8X73)
may be used ONLY in installations where rigid
metal or flexible metal transition ducting cannot be
used AND where a 4” diameter can be maintained
throughout the entire length of the transition duct.
In Canada and the United States, only transition
ducts that comply with UL 2158A STANDARD
FOR CLOTHES DRYER TRANSITION DUCT
shall be used.
Avoid resting the duct on sharp objects.
For best drying performance:
1. Slide one end of the duct over the clothes
dryer outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position,
extend the duct to its full length. Allow 2”
of duct to overlap the exhaust pipe. Cut off
and remove excess duct. Keep the duct as
straight as possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the
other clamp.
Ŷ
Phillips-head
screwdriver
Ŷ
Duct tape or
duct clamp
Ŷ
Rigid or UL-listed flexible
metal 4” (10.2 cm) duct
Ŷ
Drill with 1/8” drill bit
(for bottom venting)
Ŷ
Hacksaw
Ŷ
Vent hood
This dryer MUST be vented to the outdoors.
Use only 4” rigid metal ducting for the home
exhaust duct.
Use only 4” rigid metal or UL-listed dryer
transition duct to connect the dryer to the
home exhaust.
DO NOT use a plastic vent.
DO NOT exhaust into a chimney, kitchen
exhaust, gas vent, wall, ceiling, attic, crawl
space, or concealed space of a building.
DO NOT install a screen in or over the exhaust
duct.
DO NOT install a booster fan in the exhaust
duct.
DO NOT use duct longer than specified in the
exhaust length table.
Failure to follow these instructions can result in
death or fire.
PARTS AVAILABLE FROM
GEAPPLIANCEPARTS.COM OR
LOCAL SERVICE ORGANIZATIONS
PM8X85
Outdoor exhaust hood
PM08X10085
8’ Flexible metal clothes dryer transition
duct with 2 clamps
WX08X10130
4” Dryer exhaust clamp
WE49X22606
Rear exhaust opening cover, for side or
bottom vented dryers
- Fire Hazard
WARNING
13
Installation Instructions
EXHAUSTING THE DRYER (cont.)
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reduce the dryer life.
Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not
covered by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust
system depends upon the type of duct, number of turns,
the type of exhaust hood (wall cap) and all conditions
noted on the chart.
Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
Any elbow greater than 45° should be treated as a 90°
elbow; one elbow of 45° or less may be ignored.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to
the chart.
For every additional 90° elbow, reduce the allowable
vent system length by 10 feet.
When calculating the total vent system length, you
must add all the straight portions and elbows of the
system (including the transition duct).
EXHAUST LENGTH
EXHAUST
LENGTH
FOR
NORMAL
VENT
MODELS
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short run
installations
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
No. of 90° Elbows Rigid Metal Rigid Metal
0 90 Feet 60 Feet
1 60 Feet 45 Feet
2 45 Feet 35 Feet
3 35 Feet 25 Feet
4 25 Feet 15 Feet
EXHAUST
LENGTH
FOR
LONG
VENT
MODELS
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
Use only for short run
installations
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
No. of 90° Elbows Rigid Metal Rigid Metal
0 200 Feet 175 Feet
1 185 Feet 165 Feet
2 175 Feet 155 Feet
3 165 Feet 145 Feet
4 155 Feet 135 Feet
5 145 Feet 125 Feet
DO NOT bend
or collapse
ducting.
Use elbows
if turns are
necessary.
DO NOT use
excessive
exhaust
length. Cut
duct as short
as possible.
DO NOT
crush duct
against
the wall
.
DO NOT
set dryer
on duct
.
DO cut duct as short
as possible and
install straight into
wall.
DO use elbows
when turns are
necessary.
Elbows
14
Installation Instructions
BEFORE YOU BEGIN
Remove and discard existing plastic or metal foil
duct and replace with UL-listed duct.
Remove any lint from the wall exhaust opening.
Internal
Duct
Opening
Wall
Check that exhaust
hood damper
opens and closes
freely.
STANDARD REAR EXHAUST
We recommend that you install your dryer before
installing your washer. This will permit direct
access for easier exhaust connection.
Slide the end of the exhaust duct on the back of the
dryer and secure with duct tape or a hose clamp.
NOTE: We strongly recommend using rigid metal
exhaust duct. However, if flexible ducting is used it
must be UL-Listed metal, not plastic.
For straight line installation, connect the dryer
exhaust to the external exhaust hood using duct
tape or clamp.
RECOMMENDED CONFIGURATION
TO MINIMIZE EXHAUST BLOCKAGE
Using duct elbows will prevent duct kinking and
collapsing.
EXHAUST SYSTEM CHECKLIST
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of
birds or other wildlife.
Termination should present minimal resistance to
the exhaust airflow and should require little or no
maintenance to prevent clogging.
Wall caps must be installed at least 12” above ground
level or any other obstruction with the opening pointed
down.
SEPARATION OF TURNS
For best performance, separate all turns by at least
4 ft. of straight duct, including distance between
last turn and dampened exhaust hood (wall cap).
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end
of each section of duct must point away from the dryer.
Duct joints should be made air- and moisture-tight
by wrapping the overlapped joints with duct tape or
aluminum tape.
Do not assemble ductwork with any fasteners that
extend into the duct. These fasteners can accumulate
lint, creating a potential fire hazard.
Horizontal runs should slope down towards the
outdoors 1/4” per foot.
Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once a year.
INSULATION
Ductwork that runs through an unheated area or is
near air conditioning should be insulated to reduce
condensation and lint build-up.
Wall Side
Dryer
Side
Duct Tape
EXHAUSTING THE DRYER (cont.)
Duct
Transition
Ducting
Installation Instructions
SIDE OR BOTTOM VENTING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with cover plate (Kit
WE49X22606).
Failure to do so may result in fire, electrical
shock or lacerations.
- Fire Hazard
WARNING
15
SIDE OR BOTTOM VENTING (cont.)
Dryer Exhaust to right of the cabinet for Electric
models only.
Dryer Exhaust to left* of the cabinet for Gas and
Electric models.
Dryer Exhaust to the bottom of cabinet for Gas
and Electric models.
Detach and remove the right (electric models only),
left* or bottom knockout as desired. Remove the
screw inside the dryer exhaust duct and save.
Pull the duct out of the dryer.
Cut the duct as shown and keep portion A.
ADDING A NEW DUCT
Reconnect the cut portion (A) of the duct to the blower
housing. Make sure that the shortened duct is aligned
with the tab in the base. Use the screw saved previously
to secure the duct in place through the tab on the
appliance base.
ADDING ELBOW AND DUCT FOR
EXHAUST TO RIGHT (ELECTRIC
MODELS ONLY) OR LEFT* SIDE OF
CABINET
Preassemble 4” elbow with 4” duct. Wrap duct tape
around joint.
Insert duct assembly, elbow first, through the side
opening and connect the elbow to the dryer internal
duct.
Be sure not to pull or damage the electrical
wires inside the dryer when inserting the duct.
TAB LOCATION
Remove
screw
and save
Remove desired
knockout (one only)
Right
(electric
models
only)
Left*
Bottom
Through the rear opening, locate the tab in the middle
of the appliance base. Lift the tab to about 45°,
using
a flat-blade screwdriver.
Portion “A”
Right (electric
models only)
or left* side
exhaust
Fixing hole
Left*
Right
Exhaust can be
added to right
(electric models
only) or left* side
Duct
tape
Right
Left*
* Left side exhaust is not available for Long Vent models.
For 7.0 cu. ft models only, use the dimension below:
Fixing hole
A
9” (22.86cm)
Bend tab
up 45°
Not for gas models
Left*
EXHAUSTING THE DRYER (cont.)
Fixing hole
A
13
1
»2” (34.29cm)
For 7.5 cu. ft models only, use the dimension below:
Installation Instructions
EXHAUSTING DRYER (cont.)
SIDE OR BOTTOM VENTING (cont.)
ADDING COVER PLATE TO REAR OF
CABINET
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET (cont.)
Apply duct tape as shown
on the joint between the
dryer internal duct and
the elbow, and also the
joint between the elbow
and the side duct.
Use 4” rigid metal ducting
only inside the dryer. Internal duct joints must be
secured with tape, otherwise they may separate
and cause a safety hazard.
DUCT
TAPE
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
Insert the elbow through the rear opening and
connect it to the dryer internal duct.
Apply duct tape as
shown on the joint
between the dryer
internal duct and the
elbow, and also the
joint between the elbow
and the bottom duct.
Internal duct joints
must be secured with tape; otherwise, they may
separate and cause a safety hazard.
Duct tape
FINAL SETUP
LEVEL THE DRYER
Stand the dryer upright near the final location and
adjust the four leveling legs at the corners to ensure
that the dryer is level from side to side and front to
rear.
Lower
Raise
PLUG DRYER IN
1
2
DRYER START-UP
Press the Power button.
NOTE: If the dryer has been
exposed to temperatures
below freezing for an extended
period of time, allow it to warm up before pressing Power.
Otherwise, the display will not come on.
The dryer is now ready for use.
3
Ensure proper
ground exists
before use.
Connect standard metal elbows and ducts to complete
the exhaust system. Cover back opening with the plate
(kit WE49X22606) which can be purchased from
GEApplianceparts.com or a local service provider.
Place dryer in final location.
Plate
(Kit WE49X22606)
NEVER LEAVE THE BACK OPENING WITHOUT
THE PLATE.
(appearance will vary)
Disconnect power supply before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
WARNING
- Shock Hazard
Certain internal parts are intentionally not grounded
and may present a risk of electric shock only during
servicing.
Service personnel – DO NOT contact the following
parts while the appliance is energized: Power
button, Start/Pause button, electronic board, outlet
thermostat, outlet thermistor or water valve.
- Electrical Shock Hazard
WARNING
16
La instalación de la secadora debe efectuarla un
instalador calificado.
Instale la secadora de ropa de acuerdo con estas
instrucciones y en cumplimiento con los códigos locales.
NO instale una secadora de ropa con conductos de
plástico flexible. Si se instala un conducto flexible de
metal (semi rígido o de tipo papel de aluminio), debe
estar aprobado por UL e instalarse de acuerdo con
las instrucciones de “Cómo conectar la secadora a la
ventilación doméstica” de este manual. Los materiales
de los conductos flexibles a menudo se desploman,
se aplastan y atrapan pelusas. Estas condiciones
obstruyen la corriente de aire de la secadora e
incrementan el riesgo de incendio.
NO instale o almacene este aparato en un lugar
donde se vea expuesto al agua o a las inclemencias
del tiempo.
Para reducir el riesgo de una lesión grave o de muerte,
cumpla con todas las instrucciones de instalación.
Guarde estas instrucciones. (Instaladores: Asegúrense
de dejar estas instrucciones al consumidor).
En la Mancomunidad de Massachusetts,
se aplican las instrucciones de instalación
siguientes:
Este producto debe instalarlo un plomero
matriculado o un instalador de gas.
Cuando use válvulas esféricas de apagado de gas,
deberán ser del tipo de manija en T.
Si se usa una conexión flexible para gas, ésta no
debe superar 1.22 m (4 pies).
SECADORAS A GAS ÚNICAMENTE
Instrucciones
de Instalación
Secadora
04
ANTES DE COMENZAR
Lea estas instrucciones por completo y con
detenimiento.
IMPORTANTE
Guarde estas instrucciones para el
uso de inspectores eléctricos locales.
IMPORTANTE
Cumpla con todos los códigos y
ordenanzas vigentes.
Instale la secadora de acuerdo con las instrucciones del
fabricante y los códigos locales.
Nota al instalador Asegúrese de dejar estas
instrucciones con el consumidor.
Nota al usuario Conserve estas instrucciones para
referencia futura.
La instalación de la secadora debe efectuarla un
instalador calificado.
Esta secadora debe tener una salida al exterior.
Antes de que la secadora antigua sea retirada del
servicio o eliminada, quítele la puerta.
No permita que niños se suban o se metan dentro del
artefacto. Se requiere una supervisión estricta cuando el
aparato es utilizado cerca de niños.
El instalador tiene la responsabilidad de efectuar una
instalación adecuada.
La garantía no cubre las fallas del producto debido a una
instalación incorrecta.
Instale la secadora en lugares donde la temperatura sea
mayor a 50°F para un funcionamiento satisfactorio del
sistema de control de la secadora.
Quite y descarte el conducto existente de plástico o de
papel de aluminio y coloque un conducto aprobado por UL.
La información sobre reparaciones y el diagrama del
cableado se encuentran en la consola de control.
ADVERTENCIA
- Riesgo de incendio
31-16769-5 08-18 GEA
234D2274P004
Consulte su Manual del Propietario para obtener detalles sobre cómo contactarnos con respecto a las
preguntas de instalación
GE Appliances recomienda enfáticamente el uso de
piezas específicas de fábrica. A continuación figura una
lista de mangueras de fábrica que podrá adquirir. Dichas
mangueras son fabricadas y probadas de modo que se
cubran las especificaciones de GE Appliances.
GE Appliances recomienda enfáticamente el uso de
nuevas mangueras de suministro de agua. Con el paso del
tiempo, las
mangueras se degradan y deben ser reemplazadas
cada 5 años, a fin de reducir el riesgo de fallas sobre las
mismas y daños con el agua.
Piezas y Accesorios
Ordene hoy a través de Internet en GEApplianceparts.com,
las 24 horas del día o en forma telefónica llamando al
877.959.8688, durante el horario comercial habitual.
MANGUERA DE VAPOR Y AGUA (sólo para los modelos de secadoras de vapor):
Número de Pieza
Accesorio
WE25X20060 Kit Completo (mangueras,
adaptador en Y, arandelas) o
WE49X25794 Kit (Manguera corta, adaptador en
Y, arandelas) y
WE1M847
Manguera Larga
O POR SEPARADO
WE1M847
Manguera Larga y
WE1M848
Manguera Corta
Instrucciones de instalación
Incline la secadora de costado y saque los soportes de espuma de embalaje tirando de los costados y
quitándolos de las patas de la secadora. Asegúrese de quitar todas las piezas de espuma de las patas.
Saque la bolsa que contiene la información.
CÓMO DESEMPACAR LA SECADORA
DIMENSIONES APROXIMADAS
Con pedestal: 52 3/8” (133 cm)
Apilada: 84” (213.36 cm) - 7,5 pies cú. modelos
79 5/8” (202.25 cm) - 7,0 pies cú. modelos
NOTA: La altura de la secadora puede ser ajustada para quedar a la misma a altura de la lavadora.
4 3/8”
(11,11 cm)
Visión lateral
X
39 3/8”
(100 cm)
27”
(68,6 cm)
39 3/8”
(100 cm)
Visión frontal
X
32 3/16” (81,76 cm)
7,0 pies cú.
modelos
33” (83,80 cm)
7,5 pies cú.
modelos
Y
4 1/2” (11,43 cm)
7,0 pies cú.
modelos
5 3/8” (13,65 cm)
7,5 pies cú.
modelos
Y
ACCESORIOS:
Ordene hoy a través de Internet en GEApplianceparts.com,
las 24 horas del día o en forma telefónica llamando al
877.959.8688, durante el horario comercial habitual.
Número de Pieza
Accesorio
SBSD137HWW
Pedestal blanco 27” de ancho
SBSC137HDG
Pedestal gris diamante 27” de
ancho
GEFLSTACK Kit para apilar Secadora sobre
Lavadora
PM08X10085
Ducto de transición de metal flexible
WE01X20677
Estante de secadora para zapatos
2
Instrucciones de instalación
INSTALACIÓN EN CASAS MÓVILES
O PREFABRICADAS
Instalación DEBE cumplir con la NORMA SOBRE
CONSTRUCCIÓN Y SEGURIDAD DE CASAS
PREFABRICADAS, TÍTULO 24, PARTE 3280 o
NORMA PARA CASAS RODANTES CAN/CSA-Z240
MH, o, cuando dicha norma no sea aplicable, con
la NORMA NACIONAL ESTADOUNIDENSE PARA
CASAS MÓVILES, ANSI/NFPA 501B.
La secadora DEBE tener ventilación al exterior.
La ventilación del escape DEBERÁ estar ajustado de forma
segura a una parte no combustible de la casa rodante.
La ventilación NO DEBE terminar debajo de una casa
móvil o prefabricada.
El material del conducto de ventilación DEBE SER METAL.
DEBE utilizarse el KIT 14-D346-33 para conectar bien la
secadora a la estructura.
La ventilación NO DEBE conectarse a ningún otro
conducto, ventilación o chimenea.
NO utilice tornillos para placas de metal u otros
dispositivos de sujeción que se extiendan al interior
de la ventilación de salida.
Debe contar con una abertura con un espacio libre de
por lo menos 25 pulgadas cuadradas para el ingreso
de aire exterior dentro de la secadora habitación.
Para acceder a información sobre la conexión eléctrica,
consulte la section.
REQUERIMIENTOS - INSTALACIÓN
EN NICHOS O ARMARIOS
Mantenga cualquier material y vapores inflamables,
tales como gasolina, alejados de la secadora.
Coloque la secadora a por lo menos 18” (46 cm.)
del piso cuando sea instalada en un garaje.
Si no se cumple con esto, se podrá producir una
explosión, incendio o la muerte.
Esta secadora DEBE tener una ventilación al exterior.
El espacio libre mínimo entre el armario de la secadora y
las paredes adyacentes u otras superficies es:
0” sobre ambos lados
1” la parte trasera
1” sobre el frente
1” superior
Se deberá considerar que se debe brindar el despeje
adecuado para la instalación y el servicio técnico.
Las puertas del armario deben contar con rejillas u otro
tipo de ventilación y tener por lo menos 60 pulgadas
cuadradas de espacio abierto. Si el armario incluye una
lavadora y una secadora, las puertas deben contener
un mínimo de 120 pulgadas cuadradas de espacio
abierto.
NOTA: CUANDO EL CONDUCTO DE SALIDA ESTÁ
UBICADO EN LA PARTE TRASERA DE LA SECADORA,
LA CONFIGURACIÓN DEL DUCTO PODRIA REQUERIR
DETRÁS UN CLARO MAYOR A 1 PULGADA.
Secadoras a Gas Únicamente:
No se deberá instalar ningún otro electrodoméstico que
consuma combustible en el mismo armario donde haya
una secadora a gas.
La secadora se deberá desconectar de la tubería de
suministro de gas durante la prueba de presión en
presiones superiores a ½ psi (3.5 kPa).
Una rosca cubierta NPT de 1/8”, accesible para la
conexión de un dispositivo de calibración, deberá ser
instalada inmediatamente arriba de la conexión del
suministro de gas a la secadora.
- Riesgo de
explosión
ADVERTENCIA
ESPACIO LIBRE MÍNIMO EN
OTROS ESPACIOS QUE NO SEAN
INSTALACIONES EN NICHOS O
ARMARIOS
Los espacios libres mínimos respecto de superficies
combustibles y de aberturas de aire son: 0” a ambos
lados, 1” en la parte trasera y 1” superior. Debe
tenerse en cuenta un espacio libre adecuado para un
funcionamiento y reparación correctos.
3
Instrucciones de instalación
4
CÓMO CONECTAR MANGUERAS DE ENTRADA
(sólo para los modelos de secadoras de vapor)
CÓMO CONECTAR MANGUERAS
DE ENTRADA
Para producir vapor, la secadora debe
conectarse al suministro de agua fría. Ya que
la lavadora también debe conectarse al agua
fría, debe introducirse un conector en “Y” para
permitir que ambas mangueras de entrada
puedan utilizarse al mismo tiempo.
NOTA: Utilice nuevas mangueras de entrada;
nunca utilice mangueras viejas.
1. Cierre el grifo de agua fría. Quite la manguera
de entrada de la lavadora del conector de la
válvula de llenado (fría).
2. Asegúrese de que la arandela plana de
goma se encuentre en su lugar y sujete una
unión hembra de la manguera corta provistas
en el conector de la válvula de llenado de
la lavadora. Ajuste a mano hasta que esté
firmemente asentada.
3. Sujete un extremo macho del conector en
“Y” a la unión hembra de la manguera corta.
Asegúrese de que la arandela plana de goma
se encuentre en su lugar. Ajuste a mano hasta
que esté firmemente asentada.
4. Introduzca el filtro en la unión de la manguera
de entrada de la lavadora. Si la arandela plana
de goma ya se encuentra en su lugar, quítela
antes de instalar el filtro. Sujete esta unión a un
extremo macho del conector en “Y”. Ajuste a
mano hasta que esté firmemente asentada.
5. Asegúrese de que la arandela de goma plana
se encuentra en su posición y coloque una
manguera de entrada de agua de 4 a 6 pies
de largo (puede ser necesario comprarla por
separado) a un extremo macho del conector
‘’Y‘’. Apriete con la mano hasta que quede
firmemente asentado.
6. Asegúrese de que la arandela plana de goma se
encuentre en su lugar y sujete el otro extremo
de la manguera larga de entrada al conector
de la válvula de llenado en la parte inferior del
panel trasero de la secadora. Ajuste a mano
hasta que esté firmemente asentada.
CÓMO CONECTAR MANGUERAS
DE ENTRADA (cont.)
7. Utilizando alicates, ajuste todas las uniones
con un giro adicional de dos tercios.
NOTA: No ajuste de más. Pueden dañarse las
uniones.
8. Abra el grifo de agua.
9. Controle la presencia de pérdidas alrededor
del conector en “Y”, el grifo y las uniones de
las mangueras.
REQUISITOS DE SUMINISTRO DE
AGUA
Los grifos de agua caliente y fría DEBEN
instalarse dentro de las 42 pulg. (107 cm) de
la entrada de agua de la lavadora. Los grifos
DEBEN ser del tipo de manguera de jardín
de 3/4 pulg. (1.9 cm) para que las mangueras
de entrada puedan conectarse. La presión de
agua DEBE hallarse entre 10 y 120 libras por
pulgada cuadrada. La compañía de agua puede
informarle sobre la presión de agua.
NOTA: Se recomienda el uso de un suavizante
de agua para reducir la acumulación de sarro
dentro del generador de vapor si el suministro
doméstico contiene agua muy dura.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

GE Appliances GFD55ESSNWW Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI