SPECIFICATIONS
Installation Requirements
Install the hood 30" (762) to 36" (914) from the bottom of the
hood to the countertop.
BLOWER ASSEMBLIES
Pro Hood Liners require an internal, in-line, or remote blower
assembly, avail able through an authorized Wolf dealer. For
local dealer information, visit the nd a showroom section of
our website, wolfappliance.com. Refer to specic installa-
tion instructions provided with each blower assembly.
DECORATIVE HOOD
The decorative hood can be created out of wood, plaster,
tile, or metal. The shape of the hood is not critical, however,
the decorative hood and liner must t together at the bottom
edge in both width and depth. The height of the liner does
not need to accommodate the entire height of the decora-
tive hood.
The lower
3
/4" (19) of the liner’s 4" (102) reveal is nished
stainless steel. The bottom edge of the liner should not
extend more than
3
/4" (19) below the decorative hood.
Ducting
WARNING
To reduce the risk of re, use only metal ducting.
IMPORTANT NOTE: Consult a qualied HVAC professional
for specic installation and ducting applications.
Pro hoods accommodate a 10"
(254) round duct. Use only
rigid metal ducting.
A straight, short duct run allows the hood to perform most
efciently. If the duct run exceeds 50'
(15 m), a higher CFM
blower may be required to maintain proper air ow.
Internal and in-line blowers require a roof or wall cap.
Connect ducting to the cap or to the remote blower and
work back towards the hood. Use sheet metal screws and
high-temperature duct tape to seal joints between ducting
sections.
Pro hoods include a backdraft damper. Local codes may
require the use of an additional backdraft and/or make-up
air damper. Contact your local HVAC professional for spe-
cic requirements.
A make-up air damper is available through an authorized
Wolf dealer. For local dealer information, visit the nd a
showroom section of our website, wolfappliance.com.