Ibiza Light DERBY-LAS Owner's manual

Category
Stroboscopes & disco lights
Type
Owner's manual
2
©Copyright LOTRONIC 2016 DERBY-LAS
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are
present and have been received in good condition. Notify the freight company immediately and retain packing
material for inspection if any parts appear to be damaged from shipping or the carton itself shows signs of
mishandling. Keep the carton and all packing materials. In the event that a fixture must be returned to the
factory, it is important that the fixture be returned in the original factory box and packing.
Safety Instructions
Please read these instructions carefully, they include important information about the installation, usage and
maintenance of this product.
• Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also
receives this instruction booklet.
• Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting
to is not higher than that stated on the decal or rear panel of the fixture.
• This product is intended for indoor use only!
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least 1m from adjacent surfaces. Be sure
that no ventilation slots are blocked.
• Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse
size and type.
• Maximum ambient temperature (Ta) is 104° F (40°C). Do not operate the fixture at temperatures higher than
this.
• In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the same type of spare parts.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the
disconnect device shall remain readily operable.
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
similar qualified person.
GB
3
©Copyright LOTRONIC 2016 DERBY-LAS
Specifications
Voltage .................................................................................................................. 220-240V AC~ 50/60Hz
Consumption ...................................................................................................................................... 40W
Laser class .............................................................................................................................................. 3B
Laser diode ........................................................................... Red: 120mW 650nm; green: 30mW 532nm
LED source ...................................................................................................................................... 9 x 3W
LED colours ..................................... Red, Green, Blue, White, Warm White, Orange, Yellow, Purple, UV
Dimensions ................................................................................................................. 185 x 162 x 210mm
Weight ............................................................................................................................................. 1.48kg
Power supply, wire Connection
Use a dedicated plug to connect the LED light and power. Make sure the unit is connected to the appropriate
power supply.
Warning
Carry the lights only by the handle.
Features
The control panel features 4 buttons and a 4-digit LED display.
Operation
1) When power is on, the digital LED display works with red dots. When
a DMX signal is present, the dot will be shiny.
2) DMX address code setting: Press “MENU” button. When the digital LED displays d001-d512, press “UP” or
“Downto set the address code. The code ranges from 001-512.
Button Specifications:
All Effects
Motor Speed
Autn
An01-An07
S.01-S.09
Derby effects
Motor Speed
Autp
Ap01-AP07
S.01-S.09
Laser effects
Motor Speed
AutF
AF01-AF04
S.01-S.09
Sound effect - Whole Unit
Sound Effect - Derby
Sound Effect - Laser
Sound
S.01-S.03
S0.4
S.05
SLAU
Slave
D001-d512
DMX
Connection of Signal Cable
You can use the 3-pin XLR cable to connect the OUT socket of the first light and the IN socket of the following
light. Connect all the lights as below:
4
©Copyright LOTRONIC 2016 DERBY-LAS
A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR connector with
a 120Ω resistor between the pin 2 and pin 3 of the XLR connector
Remote Control:
ON/OFF
DMX Mode
LASER: LASER ON/OFF
AUTO MIX: Auto Mode with PAR-LASER Effects
SOUND MIX: Sound Mode with PAR-LASER Effects
R: Red Laser ON
LED / Auto Mode: Par Effects
LED / Sound Mode: Par Effects
G: Green Laser ON
LASER : Laser Auto Mode
LASER: Laser Sound Mode
RG:RG Laser ON
COLOR -/+ : Color & Speed slow /fast
LASER MOTOR: Motor slow/fast
SEN -/+: Sensitivity -/+
8 DMX Channels:
CH1
0-9
10-19
(An01-7)
20-29
30-39
40-49
50-59
60-69
70-79
80-89
(Ap01-AP07)
90-99
100-109
110-119
120-129
130-139
140-149
150-159
5
©Copyright LOTRONIC 2016 DERBY-LAS
160-169
170-179
180-189
190-199
(Whole Unit)
(S.01-S.03)
200-209
210-219
220-229
230-255
CH2
0-9
10-255
CH3
0-255
CH4
0-255
CH5
0-255
CH6
0-255
CH7
0-63
64-127
128-191
192-255
CH8
0-255
Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize
light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
VII. Trouble-shooting
Problem
Solution
No display when power is on
1. Check if the power is correctly connected.
2. Check if the outlet is powered
Light is out of control
1. Check if the DMX address code is correctly set.
2. Check if the DMX cable is correctly connected.
The light is off after working for a while
1. Check if the sensor is soldered on the LED PCB
2. Check if the temperature is too high or not.
3. Check if Power supply is damaged.
The beam is dark
1. Check if the temperature is too high and cause a fast fade.
2. Check if there is too much dust on the surface of light.
This marking indicates that this product should not be disposed with other household wastes throughout
the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material resources. To return your used device,
please use the return and collection systems or contact the retailer where the product was purchased. They can
take this product for environmental safe recycling.
GB
LASER FOR PROFESSIONAL USE ONLY
This laser complies with the international standards CEI60825/EN60825. It is meant exclusively for professional use.
Its installation and use should only be carried out by a skilled technician who is aware of the specific dangers of lasers.
REMINDER OF SAFETY INSTRUCTIONS
Lasers of class 3 and 4 are for outdoor use only.
Inside the public area, any laser shooting towards the audience is strictly forbidden except if a safety area of 5 m radius is
marked around the area to which the audience cannot get access.
The area called “public area” is defined by the space of 3m above the area occupied by the audience and a width of 2.5m around
this area. The public area must be clearly identified by signs on the ground.
Inside the public area only a scanning movement is allowed within the terms and conditions defined by the international
technical laser safety report.
The laser unit must be installed out of reach of the audience and at a minimum of 3m above the ground where the audience is
present or protected by a safety perimeter of 5m radius.
The laser unit must be installed in such a way that it can’t be moved under the effect of disruptions such as crowd movements,
vibrations or gusts of wind.
Installation and settings must comply with the regulations defined in the international laser safety report CEI / TR 60825-3
(March 2008).
F
LASER A USAGE EXCLUSIVEMENT PROFESSIONNEL
Ce laser est conforme aux normes CEI60825/EN60825, il est à usage exclusivement professionnel,
Son installation et utilisation doit être effectué exclusivement par un technicien compétent et formé
aux risques spécifiques des lasers.
RAPPEL DES PRECAUTIONS DE SECURITE
Les appareils à lasers de classe 3 et 4, sont utilisables exclusivement en plein air
A l'intérieur de la zone réservée au public, aucun " tir laser " n'est admis en direction du public, quelle que soit la classe du laser,
sauf si un périmètre d'exclusion du public de 5 mètres de rayon, matérialisé, est mis en place.
La zone dite " zoneservée au public " est définie par l'espace situé jusqu'à 3 mètres au-dessus de la surface occupée par le
public et sur une bande de 2, 5 mètres autour de cette dernière. La zone réservée au public est matérialisée au sol.
Dans la zone réservée au public, seul est admis un rayonnement par balayage effectué dans les conditions fixées par le rapport
technique international sur la sécurité des appareils à laser
L'appareil à laser est hors de portée du public et au minimum à 3 mètres au-dessus du sol accessible au public ou protégé par un
périmètre de sécurité de 5 mètres de rayon.
L'appareil laser doit être fixé/posé de telle manière qu'il ne puisse pas être déplacé sous l'effet de perturbations telles que des
mouvements de foule, des vibrations ou des rafales de vent.
L'installation et les réglages respectent les dispositions fixées par le rapport technique international sur la sécurité des appareils
à laser CEI / TR 60825-3 (mars 2008).
D
LASER FÜR AUSSCHLIESSLICH GEWERBLICHEN GEBRAUCH
Dieser Laser entspricht den Normen CEI60825/EN60825. Er ist ausschließlich für gewerblichen Einsatz erlaubt.
Die Installation und Bedienung dürfen nur von einem erfahrenen Techniker vorgenommen werden, der für die spezifischen
Gefahren von Laserstrahlen ausgebildet ist.
ERINNERUNG AN DIE SICHERHEITSVORSCHRIFTEN
Laser der Klassen 3 und 4 dürfen nur im Freien eingesetzt werden.
Innerhalb des öffentlichen Bereichs darf kein Laserstrahl in Richtung des Publikums abgegeben werden, egal um welche
Laserklasse es sich handelt, es sei denn, es wurde ein auf dem Boden klar abgegrenzter und vom Publikum unzugänglicher
Sicherheitsbereich von 5m eingerichtet.
Der sogenannteöffentliche Bereichbetrifft den Bereich von 3m über dem vom Publikum eingenommenen Bereich und eine
Breite von 2,5m um diesen Bereich herum. Der öffentliche Bereich muss klar auf dem Boden gekennzeichnet sein.
In diesem öffentlichen Bereich ist nur ein Scannen unter Einhaltung der im internationalen technischen Bericht über die
Sicherheit von Lasern festgelegten Bedingungen zugelassen.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33

Ibiza Light DERBY-LAS Owner's manual

Category
Stroboscopes & disco lights
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI