Maytronics MTC6 DELUXE 5 Operating Instructions Manual

Type
Operating Instructions Manual
EN
Operating Instructions
Robot Pool Cleaner MTC6 DELUXE 5
English 1-14
FR
Instructions d’opération
Robot nettoyeur de piscine MTC6 DELUXE 5
Français 16-29
ES
Instrucciones operativas
Limpiador de piscinas Robot MTC6 DELUXE 5
Español 31-44
8151123
Operating Instructions 1-14
1
English
Standard Brush Combined Brush Wonder Brush
!
Important safety instructions
• Keep power supply out of
standing water
• Use only original Dynamic
power supply- factory wired for
100/115/230/250 VAC mains
supply
2
Beware! Very Hot!
40ºC Max
104ºF Max
GFI/ELI
1
Swivel
!
2
3
Ph
A
B
C
Click!
4
Caddy
Assembly
3
English
5
A
B
C
7
6
C
B
A
12mm
0.47inch
Click!
4
10
Soak and squeeze PVA (Wonder brush) / PVA rings (Combined brush) in water
9
CHLORINE
2 - 4 ppm
PH
7 - 7.4
32ºC 90ºF
12ºC 54ºF
NaCl
max
5000 ppm
Place cable on the right side infront of the handle
8
Shake robot from side to side or turn it upside down to release trapped air
Standard Brush Combined Brush Wonder Brush
5
English
A
B
OFF
11
12
Although the robot will perform automatic shut-off at the end of the cleaning cycle,
switch power supply “OFF” manually
13
14
10 cm
3.93 inch
6
EXIT
BACK
ENTER
SEND
EXIT
BACK
ENTER
SEND
Remote Control Unit (RCU)
1) These buttons are used for switching between menus and options.
This button is used to switch on the RCU, to select a required
menu, to SEND or to SET a parameter or a program.
This button is used to EXIT from a menu or move back a step.
This button is also used to turn off the RCU.
Press EXIT a number of times until RCU turns off.
If a parameter was modified, then just before final EXIT you may
be required to send your new set of parameters.
Description and use of menus
2) Cleaning programs
• REGULAR – Floor and walls cleaning program.
• ULTRAclean – Slower movement for special thorough cleaning.
Note: ULTRAclean mode can only be selected from REGULAR mode.
• WATERline – For special attention to walls and water line.
Note: For efficient WATERline cleaning program, position the handle diagonally
exactly as shown in [Fig B].
If you choose WATERline or ULTRAclean modes, these parameters will not remain
in the DOLPHIN memory for the next cycle. Instead, the DOLPHIN automatically
switches to REGULAR mode.
• LAPpool – Suitable for this specific type of pool – narrow and long.
Note: If you choose a LAPpool cleaning mode, set the pool length after setting this mode.
3) Parameters
• CYCLE-TIME – Choose the most suitable cycle time.
• POOL-LENGTH – Program the pool length.
• CLIMB-EVERY – This option controls the frequency of wall climbing
e.g.: at which frequency the DOLPHIN should climb on the walls.
4) Battery Replacement
If the massage “Low Battery” appears on the RCU screen:
• Open the battery cover.
• Remove all used batteries from the RCU.
• Place two 1.5 V AAA batteries into the RCU as shown in the drawing
inside the battery housing.
• Close the battery cover.
If you are not using your RCU for more than 6 months - remove batteries.
RCU
7
English
EXIT
BACK
ENTER
SEND
Parameters
Settings Language
Joystick mode
exit
Setting
Pool length - enter
Language
Set - English
English
Français
Deutsch
Español
Italiano
Dutch
Sending Data
Send
Yes/No
MTC6 DELUXE
Enter
Start up screen 2 seconds splash
Pool length
Set 12m 40ft
Cycle time
Set 3.0 Hours
Climb Every
Set 8 min
None 4 8 16
6m
20ft
8m
26ft
10m
33ft
12m
40ft
234
Clean mode
Set Regular
Pool length
Send 12m 40ft
Cycle time
Send 3.0 Hours
Sending Data
Sending Data
Sending Data
Sending Data
Clean mode
Send Regular
Climb Every
Send 8 min
Joystick
Parameters
Setting
Cycle time - enter
Setting
Climb every - enter
Setting
Clean mode - enter
Regular
Ultra
clean
Water
line
Lap
pool
RCU
Note: If RCU is not operated the DOLPHIN will enter AUTOMATIC CLEANING mode
according to the last set of parameters used.
8
18
17
It is recommended to periodically wash filter bag in a washing
machine. Use synthetic cleaning program
Filter Bag
Click!
Click!
16
15
9
English
Click!
Click!
19
20
Filter Bag
10
24
25
It is recommended to wash the cartridge after every cycle
Note: In extremely dirty pools (e.g. spring cleaning),
there is a need to open and clean the cartridge every
1/2 hr. of operation. Failing to clean the cartridge will result
in poor scanning and inability to climb the pool walls.
A
A
A
A
B
A
Cartridge
Optional
23
22
Click!
Click!
11
English
Click!
Click!
26
27
English
Cartridge
Optional
12
Ph
Ph
B
A
29
30
!
13
English
A
B
C
D
31
45ºC 113ְºF
5ºC 41ºF
45ºC 113ְºF
5ºC 41ºF
32
33
Straighten the cable from time to time
!
!
14
Optional
EXIT
BACK
ENTER
SEND
Optional
15
Instructions d’opération 14-29
16
40ºC Max
104ºF Max
GFI/ELI
1
Swivel
Instructions de sécurité importantes
• Ne pas poser le boîtier
électrique sur une surface
humide
• Utiliser uniquement l’unité
d’alimentation électrique du
Dynamic - câblé en usine
pour recevoir du courant en
100/115/230/250 VAC
2
Standard Brush Combined Brush Wonder Brush
Attention! Appareil
très chaud!
!
!
17
Français
Montage
du Caddy
3
Ph
A
B
C
Click!
4
18
5
A
B
C
7
6
C
B
A
12mm
0.47inch
Click!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Maytronics MTC6 DELUXE 5 Operating Instructions Manual

Type
Operating Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages