Danfoss H1 P pump offers reliable performance and precise control in various applications. With its advanced design, it ensures efficient operation and extended service life. The pump's robust construction and high-quality components make it suitable for demanding hydraulic systems. It provides accurate pressure regulation and efficient flow management, meeting the requirements of diverse industrial applications.

Danfoss H1 P pump offers reliable performance and precise control in various applications. With its advanced design, it ensures efficient operation and extended service life. The pump's robust construction and high-quality components make it suitable for demanding hydraulic systems. It provides accurate pressure regulation and efficient flow management, meeting the requirements of diverse industrial applications.

CHARGE PRESSURE
RELIEF VALVE REMOVAL
1. Clean pump externally with clean solvent to
remove debris.
2. Using a 1 inch wrench, remove the charge
pressure relief valve. (V10)
1. Lubricate the external O-rings using petroleum
jelly.
2. Install the new charge pressure relief valve.
Using a 1 inch socket, torque to 41-47 N•m [30-
35 lbf•ft]
CHARGE PRESSURE
RELIEF VALVE
INSTALLATION
CHARGE PRESSURE
RELIEF VALVE
ADJUSTMENT
1. Install a 50 bar [1000 psi] pressure gage in charge pressure gauge port M3 (next to the adjust-
ment screw). Install a 10 bar [100 psi] gauge at one of the case drain pressure ports L1, L2,
L3, or L4. Operate the system with the pump in neutral (zero displacement) when measuring
charge pressure.
2. The table shows the acceptable pump charge pressure range for some nominal charge relief
valve settings (refer to the model code located on the serial number plate). These pressures
assume 1800 pump rpm and a reservoir temperature of 50°C (120°F), and are referenced to
case pressure.
3. Adjust valve. Clockwise rotation of the adjusting screw increases the setting, and counter-
clockwise rotation decreases the setting.
4. Torque locknut to 10 N•m [88.5 lbf•in] using a 3/4 inch socket.
5. When desired charge p
ressure is achieved, remove the gauges and plug the ports.
Charge pressure ranges
Model code Measured charge pressure*
20 bar [290 psi] ± 1.5 bar [21.8 psi]
24 bar [348 psi] ± 1.5 bar [21.8 psi]
26 bar [377 psi] ± 1.5 bar [21.8 psi]
30 bar [345 psi] ± 1.5 bar [21.8 psi]
* This is the actual charge pressure port
gauge reading minus the case pressure
port gauge reading. Factory set at 1800
min
-1
(rpm) with a reservoir temperature
of 50° C (120° F)
Listed pressures assume a
pump speed of 1800 rpm. At
higher pump speeds (with
higher charge flows) the
charge pressure will rise over
the rated settings.
V10
41-47 N•m
[30-35 lbf•ft]
1 inch
Adjusting screw
1/4 inch
Locknut
3/4 inch
Case drain port L2
10 N•m
[88.5 lbf•in]
0 - 10 bar [0 - 100 psi]
95-136 N•m [70-100 lbf•ft]
Charge pressure gauge port M3
0 - 50 bar [0 - 1000 psi]
20-27 N•m [15-20 lbf•ft]
1/4 inch
9/16 inch
© Danfoss, 2013 BLN-10284 Rev AB • September 2013 1
Service Kit Instructions
H1 pump
Charge pressure relief valve replacement procedure
  • Page 1 1

Danfoss H1 P Installation guide

Type
Installation guide

Danfoss H1 P pump offers reliable performance and precise control in various applications. With its advanced design, it ensures efficient operation and extended service life. The pump's robust construction and high-quality components make it suitable for demanding hydraulic systems. It provides accurate pressure regulation and efficient flow management, meeting the requirements of diverse industrial applications.