Bunn Titan® Single DBC® 120/208V Brewer User manual

Category
Coffee makers
Type
User manual
TITAN DUAL
®
TITAN SINGLE
®
SERVICE & REPAIR MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
www.bunn.com
41747.0000D 10/18 ©2008 Bunn-O-Matic Corporation
ENABLE
®
I
O
TITAN
®
ENABLE
ENABLE
®
I
O
BREW
I
O
BREW
TITAN
®
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 2
41747 031314
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, ther-
mal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below:
a) Electronic circuit and/or control boards - parts and labor for 3 years.
b) Compressors on refrigeration equipment - 5 years parts and 1 year labor.
c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and
labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be
commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the
applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured
by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation,
improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality,
damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but
not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN
prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box
3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized
BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX-
PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modi-
fications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such
individuals, whether oral or written, do not constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op-
tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the
applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair
is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for
the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS
EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION
AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of
use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities
or services, or any other special, incidental or consequential damages.
392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew-
WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with
the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design,
Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet
Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment
Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com,
Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in
Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, TRIFECTA (sylized logo), Velocity Brew, Air Brew, Beverage
Bar Creator, Beverage Profit Calculator, Brew better, not bitter., Build-A-Drink, BUNNSource, Coffee At Its Best, Cyclonic
Heating System, Daypart, Digital Brewer Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Picture
Prompted Cleaning, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either
trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configura-
tion is a trademark of Bunn-O-Matic Corporation.
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 3
INTRODUCTION
This equipment will brew coffee into an awaiting server or airpot. The brewer may have an auxillary hot water
faucet. It is only for indoor use on a sturdy and level counter or shelf. Please install in an area where there are
no water jet devices.
This brewer can be programmed to adjust different functions of the brewing process, such as brew tempera-
ture, brew volumes, bypass percentages, pulse brew, etc. Other features are Energy Savings mode, Freshness
Timer and Clean Alert.
CONTENTS
Warranty .....................................................................................................................................2
Table of Contents ........................................................................................................................3
Troubleshooting ..........................................................................................................................4
Service Tools .............................................................................................................................15
Component Access ...................................................................................................................18
Control Board ......................................................................................................................18
Membrane Switch ................................................................................................................19
Dispense and Bypass Valves................................................................................................20
Refill Valves .........................................................................................................................21
Tank Heaters ........................................................................................................................22
Temperature Probe ..............................................................................................................23
Limit Thermostats ...............................................................................................................22
Contactor .............................................................................................................................23
Main Power Switch ..............................................................................................................24
Schematic (Wiring Diagram) .....................................................................................................25
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 4
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-
nel.
All electronic components have 120-240 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This brewer is heated at all times. Keep away from combustibles.
WARNING Exercise extreme caution when servicing electrical equipment.
Unplug the brewer when servicing, except when electrical tests are specified.
Follow recommended service procedures.
Replace all protective shields or safety notices.
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 5
PROBABLE CAUSE REMEDYPROBLEM
TROUBLESHOOTING (cont.)
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check
For Bad Connections
Temp Sensor Out Of Range, Check
Wire For Shorts
Equipment will not operate
1. Water temperature in the tank
does not meet the ready tempera-
ture.
1. Tank Heater failure.
2. Control Board/Thermistor failure
1. Water shut off to brewer
2. Inlet Solenoid failure
3. Control Board failure
4. ON/OFF switch is OFF
1. Temperature Sensor Probe
wire(s) broken or not making con-
nection
1. Temperature Sensor Probe
wire(s) shorted to housing or to
each other.
1. No power or incorrect voltage
A) Wait for the brewer to heat to the
proper temperature.
B) Disable the BREW LOCKOUT
function. Refer to Programming
Manual for procedure.
Service required
Service required
Check water supply shut-off
Service Required
Service Required
Turn switch ON
Check wire and connection of both
black and white wires of temperature
probe.
Check to confirm that wire(s) are
not pinched between two surfaces
or connected to each other.
Measure the voltage at the terminal
block and confirm that it matches
the voltage specified on the brewer
data plate withing +/- 10%.
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 6
TROUBLESHOOTING (cont.)
PROBABLE CAUSE REMEDY
PROBLEM
Check plumbing and shut-off valves
Check for voltage across the termi-
nals at the terminal block.
Test the ON/OFF switch. Refer to the
test switch procedures on page 17.
Test the BREW switch. Refer to the
test switch procedures on page 17.
Test the brew valve. Refer to the
test outputs procedures on page 15.
Substitute a control board known
to be in good working order.
Check plumbing and shut-off valves
Remove the strainer and check for
obstructions. Clear or replace.
1. No water
2. No power or incorrect voltage to
the brewer
3. ON/OFF switch
4. Brew switch
5. Brew valve
6. Control Board
Brew cycle will not start
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 7
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE REMEDY
Check the sensitivity setting. Refer
to the REFILL function in Program-
mimg Manual. If the left three digit
number is less than the right num-
ber, the machine “thinks” it is full and
the refill valve should be off. If the left
number is larger than the right, then
the refill valve will automatically be
turned on to fill the tank. The right
number is the threshold setting and
can be adjusted to compensate for
extreme water conditions: very pure,
low conductance water requires a
higher setting, while high mineral
content, high conductance water
requires a lower setting. Note that
the left number changes from a high
value when water is NOT touching
the refill probe to a low valve when
water IS touching the probe. For
best operation, the right number
should be set to a value midway
between these low and high num-
bers. Before changing the setting,
confirm that the refill probe is free
of scale buildup and the connection
to it is secure. Test the refill valve.
Refer to the test outputs procedures
on page 15.
Refill valve – Disconnect the brewer
from the power source and remove
wires from refill valve coil. Check
for continuity across the terminals
of the solenoid coil. If continuity is
Automatic refill will not operate or
display shows FILL TIME TOO LONG
1. No water
2. Refill valve
3. Refill probe or Sensitivity setting
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 8
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
not present, replace the refill valve.
If continuity is present, the coil may
be stuck closed. Shut water off to
brewer. Press the ON/OFF switch to
turn off the brewer. Open the faucet
and drain water down in the tank
until flow stops or slows to a trickle.
Attach a voltmeter to the terminals
of the refill solenoid. Connect the
brewer to the power source. Press
the ON/OFF switch to turn the brewer
on. Within five seconds, voltage
should be present at the solenoid
terminals. If voltage is not present,
refer to the wiring schematic and
check the wiring harness.
Substitute a control board known
to be in good working order.
ON/OFF switch must be ON for the
refill circuit to operate. Turn ON.
When this condition occurs, the
brewer will display OVERFLOW
CUP FULL. EMPTY CUP. The reason
for overfilling could be a defective
refill valve, an incorrect sensitivity
setting, (see above) or boiling.
4. Control Board
5. ON/OFF Switch
6. Overflow Safety Switch
Automatic refill will not operate or
display shows FILL TIME TOO LONG
(Continued)
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 9
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Water flows into tank continuously
with power removed from brewer.
1. Refill valve
2. Refill probe or sensitivity setting
3. Control Board
Foreign material lodged in valve,
holding it in open state.
Check the sensitivity setting. Refer
to the REFILL function in Program-
ming Manual. If the left three digit
number is less than the right num-
ber, the machine “thinks” it is full and
the refill valve should be off. If the
left number is larger than the right,
then the refill valve will automatically
be turned on to fill the tank. The right
number is the threshold setting and
can be adjusted to compensate for
extreme water conditions: very pure,
low conductance water requires a
higher setting, while high mineral
content, high conductance water
requires a lower setting. Note that
the left number changes from a high
value when water is NOT touching
the refill probe to a low valve when
water IS touching the probe. For
best operation, the right number
should be set to a value midway
between these low and high num-
bers. Before changing the setting,
confirm that the refill probe is free
of scale buildup and the connection
to it is secure.
Substitute a control board known
to be in good working order.
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 10
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Water will not heat or display shows
HEATING TIME TOO LONG.
1. Limit Thermostats
2. Temperature probe
3. Tank heaters
4. Control Board
Remove power from the brewer.
Check for continuity through the
limit thermostat. CAUTION: Do not
eliminate or bypass limit thermo-
stat. Use only replacement part
23717.0003.
Remove the probe from the grom-
met and submerge in a water bath
of approximately 70°F (21°C).
Connect an ohmmeter to the pins
in the connector. At 60°F (16°C),
the reading should be 15.3k ± 2k
OHMS, at 70°F (21°C) the reading
should be 11.8k ± 2k OHMS, and
at 80°F (27°C) the reading should
be 9.3k ± 2k OHMS. If the probe is
within these parameters, reconnect
to the control board.
Remove power from the brewer.
Check for continuity through the
tank heaters. If no continuity is
present, check for a wiring problem
(consult wiring schematic), then
replace the tank heater if no wiring
problem is found.
Remove power from the brewer.
Connect a voltmeter across the
tank heater. Reapply power to the
brewer and refer to testing outputs
on page 15. If the voltage measured
when the tank heater is turned on
is very low or zero, then substitute
a control board know to be good
working order.
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 11
No bypass water
Spitting or unusual steaming from
sprayhead or air vent.
1. Bypass valve
1. Lime buildup
2. Temperature probe
3. Control Board
Test the bypass valve. Refer to the
test outputs procedures on page 15.
Inspect the probe and tank assembly
for excessive lime deposits. Delime
as required.
Remove the probe from the grom-
met and submerge in a water bath
of approximately 70°F (21°C).
Connect an ohmmeter to the pins
in the connector. At 60°F (16°C),
the reading should be 15.3k ± 2k
OHMS, at 70°F (21°C) the reading
should be 11.8k ± 2k OHMS, and
at 80°F (27°C) the reading should
be 9.3k ± 2k OHMS. If the probe is
within these parameters, reconnect
to the control board.
Remove power from the brewer.
Connect a voltmeter across the
tank heater. Reapply power to the
brewer and refer to testing outputs
on page 15. If the voltage measured
when the tank heater is turned on
is very low or zero, then substitute
a control board know to be good
working order.
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 12
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Inconsistent beverage level in
server/dispenser
Check operating water pressure to
the brewer. It must be between 20
and 90 psi (138 and 620 kPa).
Test the brew valve. Refer to test
outputs on page 15. Turn the valve
on for 30 seconds and collect the
water dispensed from the spray-
head. Repeat the test several times
to confirm a consistent volume of
dispensed water. If not consistent,
check the valve, tubing and spray-
head for lime buildup.
If bypass is being used on the incon-
sistent brew, test the bypass valve.
Refer to test outputs on page 15.
Turn the valve on for 30 seconds and
collect the water collected from the
funnel. Repeat the test several times
to confirm a consistent volume of
dispensed water. If not consistent,
check the valve, tubing and fittings
for lime buildup.
Inspect for lime buildup that could
block the tank, tank fittings, tubing,
valves and sprayhead.
Adjust the brew volume, calibrate
sprayhead and bypass as required
to achieve the desired volume for
each brew cycle.
1. Improper water pressure
2. Brew valve
3. Bypass valve
4. Lime buildup
5. Brew volume adjustment
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 13
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Dripping from sprayhead.
Water overflows filter.
Beverage overflows server.
Brewer is making unusual noises.
Repair or replace leaky valve
BUNN paper filters should be used
for proper extraction
Check sprayhead
The brew cycle should be started
only with an empty server under
the funnel.
Adjust the brew volume, calibrate
sprayhead and bypass as required
to achieve the desired volume for
each brew cycle
The mounting screws on the so-
lenoids must be tight or they will
vibrate during operation
Plumbing lines should not be resting
on the countertop.
The brewer must be connected to a
cold water line. Water pressure to
the brewer must not be higher than
90 psi (620 kPa). Install a regulator
if necessary to lower the working
pressure to approximately 50 psi
(345 kPa).
Remove and clean lime off tank
heaters.
1. Brew valve
1. Type of paper filter
2. No sprayhead
1. Beverage left in server from
previous brew
2. Brew volume adjustment
1. Solenoids
2. Plumbing lines
3. Water supply
4. Tank heaters
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 14
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Weak beverage. BUNN paper filters should be used
for proper extraction
A sufficient quantity of fresh drip
or regular grind should be used for
proper extraction.
Bunn-O-Matic sprayhead should
be used to properly wet the bed of
ground coffee in the funnel
The BUNN paper filter should be
centered in the funnel and the bed
of grounds leveled by gently shak-
ing. Use the four wire loops on the
funnel to hold filter in place while
brewing.
Empty the server, remove its cover,
and place the server beneath the
sprayhead. Place empty funnel over
the server entrance (not in the funnel
rails). Press brew. Check the water
temperature immediately below
the sprayhead with a thermometer.
The reading should not be less than
195°F (90°C).
1. Type of paper filter
2. Coffee
3. Sprayhead
4. Funnel Loading
5. Water temperature
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 15
SERVICE TOOLS
This function allows the testing of individual com-
ponents and the ability to check switches for proper
function.
Procedure to test components and outputs:
The following components can be individually tested:
SINGLE Brewers
Brew Valve
Bypass Valve
Funnel Lock
Refill Valve
Tank Heater Relay
DUAL Brewers
Left Brew Valve
Left Bypass Valve
Left Funnel Lock
Right Brew Valve
Right Bypass Valve
Right Funnel Lock
Refill Valve
Tank Heater Relay
Procedure to test components (outputs):
1. Place brew funnel(s) into rails on the brewer (both
sides on DUAL brewers).
2. Place a server(s) beneath the brew funnel(s).
3. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right
hidden button until the display reads SERVICE
TOOLS.
4. Press and release YES. The display should now
read TEST OUTPUTS? Press and release YES to
test individual components and outputs. Pressing
NO will advance to the next programming function,
TEST SWITCHES.
5. The display should now read:
BREW VALVE on SINGLE brewers
<- <- BREW VALVE on DUAL brewers.
To test the brew valve, press ON. If the brew valve
is functional, water should run from the funnel (left
side on DUAL brewers).
6. Press OFF to end the flow of water.
7. Press NEXT to advance to the next component to
be tested.
NOTE: To bypass testing any component, press NEXT
to advance to the next component without testing the
previous one.
8. The display should now read:
BYPASS VALVE on SINGLE brewers
<- <- BYPASS VALVE on DUAL brewers
To test the left bypass valve, press ON. If the
bypass valve is functional, water should run from
the funnel (left funnel on DUAL brewers).
9. Press OFF to end the flow of water.
10. Press NEXT to advance to the next component to
be tested.
11. To test FUNNEL LOCK on SINGLE brewers or LEFT
FUNNEL LOCK on DUAL brewers, press ON. If the
funnel lock is functional, the lock will come down
to hold the funnel in place.
12. Press OFF to retract the funnel lock.
13. For DUAL brewers, follow steps 5-12 to test the
right side components.
14. To test the REFILL VALVE, press ON. If the refill
valve is functional, the sound of the valve operating
will be heard.
15. Press OFF to end testing of the refill valve.
16. Press NEXT to advance to the next component to
be tested, TANK HEATR RELAY.
17. To test the tank heater relay, connect a voltmeter
across each of the tank heaters to check for volt-
age.
18. Press ON. The correct voltage should be present
at the heater terminals.
19. Press OFF to end testing of the tank heater relay.
NOTE: The tank heater will automatically turn off if
left on too long.
20. Press NEXT to return to the TEST OUTPUTS
screen. To advance to the next function screen,
TEST SWITCHES, press NO. To exit programming,
press and release the ON/OFF switch (either on
DUAL brewers) to return to the MAIN SCREEN.
Procedure to test switches:
This function allows the operator to test the opera-
TROUBLESHOOTING (cont.)
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 16
SERVICE TOOLS (cont.)
TROUBLESHOOTING (cont.)
TEST OUTPUTS?
NO YES
SERVICE TOOLS?
NO YES
LEFT BREW VALVE
ON NEXT OFF
LEFT BYPASS
ON NEXT OFF
LEFT FUNNEL LOCK
ON NEXT OFF
RIGHT BREW VALVE
ON NEXT OFF
RIGHT BYPASS
ON NEXT OFF
RIGHT FUNEL LOCK
ON NEXT OFF
REFILL VALVE
ON NEXT OFF
TANK HEATR RELAY
ON NEXT OFF
BREW VALVE
ON NEXT OFF
BYPASS
ON NEXT OFF
FUNNEL LOCK
ON NEXT OFF
SINGLE
BREWERS
DUAL
BREWERS
EXIT TO
NEXT FUNCTION
SCREEN
TEST SWITCHES?
NO YES
NOTHING PRESSED
AFTER ALL SWITCHES ARE
TESTED PRESS RIGHT
HIDDEN TO RETURN TO
TEST SWITCHES
41747 101818
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 17
SERVICE TOOLS (cont.)
TROUBLESHOOTING (cont.)
tion of the individual switches on the front panel.
The following switches can be individually tested:
SINGLE Brewers:
Full Batch
Half Batch
Power
Brew Switch
Left Hidden
DONE
(-)
(+)
DUAL Brewers:
<- <- Full Batch Full Batch -> ->
<- <- Half Batch Half Batch -> ->
<- <- Power Power -> ->
<- <- Brew Switch Brew Switch -> ->
Left Hidden DONE
(-) (+)
1. Place brew funnel(s) into rails on the brewer (both
sides on DUAL brewers).
2. Place server(s) beneath the brew funnel(s).
3. Press and hold the upper right hidden switch until
display reads SET LANGUAGE. Release the switch.
Continue to press and release switch until SERVICE
TOOLS appears.
4. Press and release YES. The display should read
TEST OUTPUTS?. Press and release NO to advance
to TEST SWITCHES.
5. Pressing NO in this screen will advance to the
next function. Press YES in the TEST SWITCHES
screen to test the switches. The display will read
NOTHING PRESSED.
6. From this screen, press any of the switches on the
front of the brewer except the upper right hidden
switch. While the switch is pressed, the display
shows the name of that switch. If the name does
not appear, or if it remains after the switch has been
released, the switch is defective. Each switch can
be tested in this manner.
7. After all switches have been tested, press and re-
lease the right hidden switch (®). This will return
to TEST SWITCHES?. To exit programming, press
and release the ON/OFF switch (either on DUAL
brewers) located on the front switch panel. This
will exit TEST SWITCHES and return to the MAIN
SCREEN.
NOTE: If the operator wishes to test more than one
function in the SERVICE TOOLS section (outputs or
switches), it is not necessary to exit the program.
Use the flow chart for SERVICE TOOLS to navigate
to a particular function.
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 18
COMPONENT ACCESS
This section provides procedures for testing and
replacing various major components used in this
brewer should service become necessary. Refer to
Troubleshooting for assistance in determining the
cause of any problem.
WARNING
- Inspection, testing, and repair of electri-
cal equipment should be performed only by qualified
service personnel. The brewer should be disconnected
from power source when servicing, except when
electrical tests are required and the test procedure
specifically states to plug in the brewer.
WARNING - Disconnect the brewer from the power
source before the removal of any panel or the replace-
ment of any component.
All components are accessible by the removal of
the top cover, front access panel.
Refer to wiring diagrams at the back of this manual
when reconnecting wires.
CONTROL BOARD
Location:
The Control Board (Fig 1) is located under the top
cover behind the control panel.
Check for Power to board:
1. Insert one meter lead in J17-pin 9 and the other
lead in J17-pin 11.
2. With the power connected to brewer, the voltage
reading to the board should be the line voltage
rated for that model.
If no voltage is present, check wiring to the board.
If voltage is present, and brewer does not power
on, replace board.
Removal and Replacement:
1. Disconnect brewer from power source.
2. Disconnect the main harness from the 14 pin con-
nector J17 on the control board.
3. Disconnect the ribbon cable from connector J2 on
the control board.
4. Disconnect the temperature probe harness from
connector J13 on the control board.
5. Disconnect level probe and overflow cup from the
8 pin connector J3 on the control board.
6. Disconnect transformer from connector J15 on
the control board.
7. Remove the two mounting nuts securing the top
of the control board to the hood.
8. Tilt the control board inward to clear the display
section and lift out of the control board mount.
9. Place the bottom edge of the new control board
in the control board mount, tilt the board forward,
and secure with the two keps nuts.
10. Re-connect wires to the circuit board.
FIG 1 CONTROL BOARD MOUNTING
Control Board Mount
Control Board Mounting Nut
Ribbon Cable
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 19
Location:
The Membrane Switch (Fig 2) is located on the front
of the hood with a ribbon cable extending through the
hood and connected to the control board.
Test Procedures:
There are two methods for testing the membrane
switch. The easiest method is to use the built in test
mode. Refer to the Trouble Shooting Section for Service
Tools/Test Switches. If for some reason you can't get
into the program modes, or brewer won't power up,
you can test it with an ohmmeter or continuity tester.
Refer to the schematic to trace the appropriate pins.
NOTE: Pin 1 is the static shield & will not provide a
reading to the other pins. There are three commons
in this circuit, pins #9, 10 & 21.
Disconnect brewer from power source before discon-
necting ribbon cable from control board.
Removal and Replacement:
1. Disconnect the ribbon cable from 22-pin connector
on the control board.
2. Gently peel the membrane switch from the hood.
3. Remove any adhesive that remains on the hood.
4. Remove the adhesive backing from the new mem-
brane switch. Insert the ribbon cable through the
slot in the hood and apply the membrane switch
to the front of the hood.
5. Reconnect the ribbon cable to the 22-pin connec-
tor on the control board making sure every pin on
the control board is inserted into the ribbon cable
connector.
FIG 2 MEMBRANE SWITCH
COMPONENT ACCESS (cont)
MEMBRANE SWITCH
ENABLE
®
I
O
TITAN
®
Membrane Switch
41747 101818
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
Page 20
Location:
The bypass valve(s) (Fig 3) are located inside the
hood under the top cover.
Test Procedures:
1. Refer to the Trouble Shooting Section for Service
Tools/Test Outputs/Bypass Valve.
2. Be sure brew funnel & server are in place before
activating valve.
3. Check the valve for coil action. Turn on the valve
with the test mode. Listen carefully in the vicinity
of the bypass valve for a click as the coil pulls the
plunger in.
If no sound is heard as described, proceed to #4.
If the sound is heard as described, there may be
a blockage in the valve , hose, or tank. Disconnect the
brewer from the power source. Remove the valve and
inspect for blockage, and de-lime all related areas.
4. Connect the voltmeter leads to the coil terminals.
Turn on the valve with the test mode. NOTE: Due
to the internally rectified coil, the indication will
be 120VAC all the time. Set the meter to DC volts.
The indication should be 170VDC when activated.
If the polarity of meter leads are reversed, reading
will indicate -170VDC. (Double these readings for
240 volt coils)
If voltage is present as described, but no coil action
is observed, valve is defective. Replace valve and test
again to verify repair.
If voltage is not present as described, refer to Wir-
ing Diagrams and check the brewer wiring harness.
Also check the control board and switch for proper
operation.
Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Disconnect wires from the valve.
3. Drain enough water from the tank so the water
level is below the outlet.
4. Remove tube(s) from the valve.
5. Remove the two #8-32 nuts mounting valve to the
bracket.
6. Install new valve using nut(s) removed in step 5.
7. Reconnect tube(s) to the valve and secure in place
with clamp(s).
FIG 3 BYPASS/DISPENSE VALVES
COMPONENT ACCESS (cont)
BYPASS VALVES
DISPENSE VALVES
Location:
The dispense valve(s) (Fig 3) are located inside
the hood under the top cover.
Test Procedures:
1. Refer to the Trouble Shooting Section for Service
Tools/Test Outputs/Dispense Valve.
2. Be sure brew funnel & server are in place before
activating valve.
3. Check the valve for coil action. Turn on the valve
with the test mode. Listen carefully in the vicinity
of the dispense valve for a click as the coil pulls
the plunger in.
If no sound is heard as described, proceed to #4.
If the sound is heard as described, there may be a
blockage in the valve , hose, tank, or sprayhead. Dis-
connect the brewer from the power source. Remove
the valve and inspect for blockage, and de-lime all
related areas.
4. Connect the voltmeter leads to the coil terminals.
Dispense Valve
Bypass Valve
Contactor
41747 112608
RELEASED FOR PRODUCTION
DIR Num: 41747.0000 12, December 2018
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Bunn Titan® Single DBC® 120/208V Brewer User manual

Category
Coffee makers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI