Sensitech TagAlert Operating instructions

Type
Operating instructions
Millions Depend on the Integrity of Your Product.
Sensitech’s Mission is to Ensure that Integrity.
TagAlert® Indicator
Instructions For Use
The Tools That Turn Information Into Power
For more information, contact our client services
group at 800-843-8367.
Sensitech Inc. • 800 Cummings Center, Suite 258X • Beverly, MA 01915
1-800-843-8367 • +1-978-927-7033 • Fax 978-921-2112 • www.sensitech.com
TempTale Manager®
Desktop Software
TempTale®4 Monitor
© 2014 Sensitech, Inc. All Rights Reserved. T83000034 Rev. H 07/09/14
RF Monitoring
TagAlert® Indicator
Data Management Services
TempTale®4 USB Monitor
AlarmAlert™ Feature
• Ifalarmed,theTagAlertindicatorprovidesamechanismtodetermineatwhichpointduring
 thetriptherstalarmwastriggered.ThisAlarmAlert™featurecanaccommodatetripsup
 to10daysinduration.
• ReadtheTagAlertandrecordwhichalarmshavetriggered(Figure 2).
• Followthenextthreestepstodeterminewhichalarmwastriggeredrstandtheapproximate
 timeatwhichthealarmtriggered:
1.PresstheStartbuttontodeterminewhichalarmtriggeredrst.Thenumberrepresent
  ingtherstalarmthattriggeredwillashfor4seconds.TheLCDdisplaywillthenclear
  for2seconds.
2. Thesumofthenumbersthatappearnextwillequalthedayintothetripthattherstalarm
was triggered (Figure 4).Thiswillbedisplayedfor2seconds.
3. Thesumofthenumbersthatappearnextwillindicatethe3-hourtimeintervalwithinthe
  daytherstalarmwastriggered(Figure 5).
• PresstheStartbuttonagaintorepeatsequenceofinformation.
Numbers Displayed on LCD Sum = Day of Trip
1 1st
2 2nd
3 3rd
44th
4 and 1 5th
4 and 2 6th
4 and 3 7th
4 and 3 and 1 8th
4 and 3 and 2 9th
4 and 3 and 2 and 1 10th
Numbers Displayed on LCD Sum Representing Time Interval Time Interval in 24 Hour Period
1 1st 0-3rdhour
2 2nd 3rd-6thhour
3 3rd 6th-9thhour
44th 9th-12thhour
4 and 1 5th 12th-15thhour
4 and 2 6th 15th-18thhour
4 and 3 7th 18th-21thhour
4 and 3 and 1 8th 21-24thhour
4 and 3 and 2 and 1 10th After10thday
Starting a TagAlert® Indicator
• PushtheSTARTbuttononthefrontofthedeviceandholdfor
 approximately1second.
• TheLCDdisplaywillrespondbydisplaying“OK”(Figure 1).
• Oncethe“OK”isdisplayed,theTagAlert®indicatorhasbeen
 activatedandentersthestart-updelayasprogrammedintotheunit.
• Onceactivated,removethebackstickerlabelandafxtoan
 instructioncardorattachdirectlytoaclean,drysurfaceofthe
 productorpackage.
Reading a TagAlert Indicator
• Oncethepackagehasarrivedatitsdestination,removethe
 TagAlertindicatorfromthepackage.
• IftheLCDdisplays“OK”,noalarmshavebeentriggered
 duringthetrip(Figure 1).
• IftheLCDdisplaysblacksquaresoverthe“OK”andthenumbers
 1,2,3and/or4,thenanalarmhasbeentriggered(Figure 2).
 Forexample,ifthenumbers1and4aredisplayed,thenthe1stand
 4thalarmconditionswereexceeded.
• Thereceivinglocationshouldfollowtheappropriateprotocolto
 determineproductdispositionifanalarmhastriggered.
Fail Safe Protection
• TheTagAlertindicatorperformsasystemcheckduringoperation
 andincorporatesaFail-Safeprotectionmodetoalerttheuser
 shouldtheunitfailtofunctionproperly.
• IftheTagAlertindicatordetectsafaultytemperaturesensororthe
 temperatureexceedstheoperationallimits(70ºC(158ºF)to-20ºC
 (-4ºF))intransit,theunitwillenterintothismodeandwill
 discontinuetemperaturemeasurement.
• TheLCDwilldisplayblacksquaresoverthe“OK”.Nonumbers
 willbedisplayedontheLCD(Figure 3).
NOTE: If any numbers appear on the LCD, that alarm has
triggered. The “OK” may still be visible through the black
squares even if an alarm has triggered.
NOTE: Days are calculated in 24 hour increments. This begins when the start button is
rst pressed and the “OK” is displayed on the LCD.
Figure 1
Figure 2
Figure 4
Figure 5
Figure 3