M 8261: 9-15V DC 20A
M 8263: 9-15V DC 30A
Operating
Instructions
Made in China for Altronic Distributors Pty Ltd
Page 4
Operating Guidelines: This unit is primarily designed for domestic use. This appliance is not
intended for use by young children or infirm persons without supervision. Young children
should be supervised to ensure they do not play with the appliance.
For repair or service please contact your place of purchase.
Note: Under no circumstances should you attempt to repair this unit yourself or a non-autho-
rised Altronics service centre.
NOT FIELD SERVICEABLE.
Distributed By:
Altronic Distributors Pty Ltd. Perth W.A. 6000
Ph: 1300 780 999 Fax: 1300 790 999
www.altronics.com.au
POWERTRAN
®
M 8261 & M 8263 Power SuppliesPOWERTRAN
®
M 8261 & M 8263 Power Supplies
Operation:
These compact bench power supplies incorporate the latest switchmode technology and
delivers regulated output between 9 and 15V. Maximum current for M 8261 is 20A, whilst the
M 8263 delivers 30A. Includes combination volt and amp meter. Voltage output is adjusted via
the front panel control. Binding posts are provided for load connection. Fitted with cooling fan.
Figure 1:
1. Power switch: turns unit on and off
2. Noise off-set control: adjust this to eliminate the pulse noise of the switching power
supply. This function is designed for communications equipment.
3. Voltage adjustment: adjusts voltage between 9.0 and 15.0 volts. Turn clockwise to
increase and counter clockwise to decrease the voltage. At the centre position, voltage will
be 13.8.
4. Meter: displays the voltage or current.
5. Output control switch: set this switch to the “adjust” setting for variable output voltage.
When set to “13.8” output will be fixed at 13.8V.
6. Meter switch: select the position to indicate voltage (V) or current (A).
7. Meter calibration: adjust the meter to the zero position.
8. Output terminal: red positive (+) and black negative (-)
9. Cooling fan
10. 240V mains connector (IEC)
11. Fuse: remove fuse cover. Always replace with M 205 (20x5mm) slow blow (time delay)
type fuse.
Cautions:
Place unit in a dry and well ventilated area.
If a short circuit occurs whilst in use, the unit will be protected by a short circuit
protection function. Turn the unit off, remove the cause of the short circuit and
switch power supply back on.
Do not use the unit for devices that require high current input for start up, such as
motorised equipment.
Do not use the unit to charge a car battery
WARNING
DO NOT BLOCK THE AIR CONVECTION SLOTS OR COOLING FAN. THESE
PREVENT OVER-HEATING.
Page 2
Page 3
Figure 1.
Specifications:
Model: M 8261 M 8263
Input voltage: a.c. 220-240V @ 50Hz a.c. 220-240V @ 50Hz
Output voltage: 9.0 - 15V d.c. (13.8V fixed) 9.0 - 15V d.c. (13.8V fixed)
Output current max: 20A 30A
Output current continuous: 18A 28A
Voltage regulation: <2% <2%
Ripple noise (at rated load): <80mV p-p <80mV p-p
Output protection: Short circuit Short circuit
Efficiency: Over 85% Over 85%
Input connection: IEC IEC
240V Input fuse: M205 (20x5mm) 5A slow blow M205 (20x5mm) 5A slow blow
Output connection: Binding posts Binding posts
Dimensions: 155 x 70 x 205mm 155 x 70 x 205mm
Weight: 1.3kg 1.5kg
POWERTRAN
®
M 8261 & M 8263 Power SuppliesPOWERTRAN
®
M 8261 & M 8263 Power Supplies
Operation:
These compact bench power supplies incorporate the latest switchmode technology and
delivers regulated output between 9 and 15V. Maximum current for M 8261 is 20A, whilst the
M 8263 delivers 30A. Includes combination volt and amp meter. Voltage output is adjusted via
the front panel control. Binding posts are provided for load connection. Fitted with cooling fan.
Figure 1:
1. Power switch: turns unit on and off
2. Noise off-set control: adjust this to eliminate the pulse noise of the switching power
supply. This function is designed for communications equipment.
3. Voltage adjustment: adjusts voltage between 9.0 and 15.0 volts. Turn clockwise to
increase and counter clockwise to decrease the voltage. At the centre position, voltage will
be 13.8.
4. Meter: displays the voltage or current.
5. Output control switch: set this switch to the “adjust” setting for variable output voltage.
When set to “13.8” output will be fixed at 13.8V.
6. Meter switch: select the position to indicate voltage (V) or current (A).
7. Meter calibration: adjust the meter to the zero position.
8. Output terminal: red positive (+) and black negative (-)
9. Cooling fan
10. 240V mains connector (IEC)
11. Fuse: remove fuse cover. Always replace with M 205 (20x5mm) slow blow (time delay)
type fuse.
Cautions:
Place unit in a dry and well ventilated area.
If a short circuit occurs whilst in use, the unit will be protected by a short circuit
protection function. Turn the unit off, remove the cause of the short circuit and
switch power supply back on.
Do not use the unit for devices that require high current input for start up, such as
motorised equipment.
Do not use the unit to charge a car battery
WARNING
DO NOT BLOCK THE AIR CONVECTION SLOTS OR COOLING FAN. THESE
PREVENT OVER-HEATING.
Page 2
Page 3
Figure 1.
Specifications:
Model: M 8261 M 8263
Input voltage: a.c. 220-240V @ 50Hz a.c. 220-240V @ 50Hz
Output voltage: 9.0 - 15V d.c. (13.8V fixed) 9.0 - 15V d.c. (13.8V fixed)
Output current max: 20A 30A
Output current continuous: 18A 28A
Voltage regulation: <2% <2%
Ripple noise (at rated load): <80mV p-p <80mV p-p
Output protection: Short circuit Short circuit
Efficiency: Over 85% Over 85%
Input connection: IEC IEC
240V Input fuse: M205 (20x5mm) 5A slow blow M205 (20x5mm) 5A slow blow
Output connection: Binding posts Binding posts
Dimensions: 155 x 70 x 205mm 155 x 70 x 205mm
Weight: 1.3kg 1.5kg
POWERTRAN
®
M 8261 & M 8263 Power SuppliesPOWERTRAN
®
M 8261 & M 8263 Power Supplies
Benchtop Power Supplies.
M 8261: 9-15V DC 20A
M 8263: 9-15V DC 30A
Operating
Instructions
Made in China for Altronic Distributors Pty Ltd
Page 4
Operating Guidelines: This unit is primarily designed for domestic use. This appliance is not
intended for use by young children or infirm persons without supervision. Young children
should be supervised to ensure they do not play with the appliance.
For repair or service please contact your place of purchase.
Note: Under no circumstances should you attempt to repair this unit yourself or a non-autho-
rised Altronics service centre.
NOT FIELD SERVICEABLE.
Distributed By:
Altronic Distributors Pty Ltd. Perth W.A. 6000
Ph: 1300 780 999 Fax: 1300 790 999
www.altronics.com.au
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

PowerTran M 8263 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI