1
AIR CONDITIONER
INSTRUCTIONS
2
• Usethisapplianceonlyasdescribedinthis
instructionmanual.
As with all electrical equipment, whilst the
instructionsaimtocoverasmanyeventuali-
tiesaspossible,cautionandcommonsense
shouldbeappliedwhenoperatingandinstal-
lingthisappliance.
• Thisapplianceisdesignedforhomeaircon-
ditioningandmustnotbeusedforotherpur-
poses.
• Itisdangeroustomodifyoralterthecharac-
teristicsoftheapplianceinanyway.
• Theappliancemustbeinstalledinconformi-
tywithnationallegislationregulatingelectri-
calequipmentandinstallations.
• If the appliance requires repair, contact a
ServiceCentreauthorisedbythemanufactu-
reronly.
Repairscarriedoutbyunauthorisedperson-
nelmaybedangerous.
• Thisappliancemustbeusedexclusivelyby
adults.
Theapplianceisnotintendedforusebyper-
sons(includingchildren)withreducedphy-
sical,sensoryormentalcapabilities,orlack
of experience and knowledge, unless they
have been given supervision or instruction
concerninguseoftheappliancebyaperson
responsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethat
theydonotplaywiththeappliance.
• Theappliancemustbeconnectedtoanef-
cientearthsystem.
Haveyourelectricalcircuitcheckedbyaqua-
liedelectrician.
• Donotuseextensioncables.
• Beforecleaningormaintenance,alwaysun-
plugtheappliancefromthemainssocket.
• Neverunplugtheappliancebypullingonthe
powercable.
• Donotinstalltheapplianceinroomscontai-
ninggas,oilorsulphur.Donotinstallnear
sourcesofheat.
• Keeptheapplianceatleast50cmawayfrom
ammable substances (alcohol, etc.) or
pressurizedcontainers(egaerosolcans).
• Donotrestheavyorhotobjectsontopofthe
appliance.
• Cleantheairlteratleastonceaweek.
• Avoidusingheatingappliancesnearthe air
conditioner.
• Alwaystransporttheapplianceuprightorre-
stingononeside.
Beforemovingtheappliance,emptythein-
ternalcircuitcompletelyofwater.
After moving the appliance, wait at least 1
hourbeforestartingit.
• Whenputtingtheapplianceaway,donotco-
verwithplasticbags.
• Thematerialsusedforpackagingcanbere-
cycled.
Youarethereforerecommendedtodispose
of themin specialdifferentiated waste col-
lectioncontainers.
• Attheendofitsworkinglife,consigntheap-
pliancetoaspecialistcollectioncentre.
• Ifthepowercableisdamaged,itmustbere-
placedbythemanufactureroranauthorised
technicalservicecentreinordertoavoidall
risk.
Check the type of refrigerant gas used by your
appliance on the rating plate.
Specific warnings for appliances with
R410A refrigerant gas
R410A refrigerant gas conforms to EC regula-
tionsontheenvironment.
Avoid perforating the refrigerant circuit of the
appliance.
ENVIRONMENTALINFORMATION:
Thisunitcontainsuorinatedgreenhousegases
coveredbytheKyotoProtocol.
Maintenanceanddisposalmustbecarriedoutby
qualiedpersonnelonly(R410A,GWP=1975).
Specific warnings for appliances with
R290 refrigerant gas
• Readthewarningscarefully.
• When defrosting or cleaning, use only
the implements recommended by the
manufacturer.
• The appliance must be placed in a room
without continuously operating sources
of ignition (for example: open ames, an
operating gas appliance or an operating
electricheater).
• Donotpierceorburn.
IMPORTANT SAFEGUARDS
3
• Refrigerantgasmaybeodourless.
• The appliance must be installed, used and
storedinaroomwithasurfaceareagreater
than15m².
• Thisappliancecontainsabout300gofR290
refrigerantgas.
• R290refrigerantgascomplieswithEuropean
environmentaldirectives.
Donot perforate any of thecomponents in
therefrigerantcircuit.
• Ifthe applianceisinstalled, used orstored
inanunventilatedroom,theroommustbe
such as to prevent stagnation of possible
leaksofrefrigerantgasastherecouldbea
dangerofreorexplosionhazardshouldthe
refrigerant come into contact with electric
heaters,stovesorothersourcesofignition.
• Theappliancemustbestoredinsuchaway
astopreventmechanicalfaults.
• Personsworkingonarefrigerantcircuitmust
havetherelativeauthorisationissuedbyan
accreditedbodycertifyingtheircompetence
tohandle refrigerants incompliancewith a
standard assessment recognised by sector
associations.
• Allrepairsmustbecarriedoutinaccordance
withthemanufacturer’srecommendations.
Maintenance and repairs requiring the
assistance of other qualied personnel
must be carried out under the supervision
of specialists in the use of inammable
refrigerants.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains
socket,checkthat:
• themainspowersupplycorrespondstothe
value indicated on the rating plate on the
backoftheappliance;
• the power socket and electrical circuit are
adequatefortheappliance;
• themainssocketmatchesheplug.Ifthisis
notthecase,havetheplugreplaced;
• themainssocketisadequatelyearthed.
Failure to follow these important safety
instructionsabsolvesthemanufacturerofall
liability.
WHAT IS THE WATER-AIR PINGUINO
During the summer, you feel comfortable at a
temperatureofbetween24and27°Cwitharela-
tivehumidityofabout50%.
Anairconditionerremovesexcessmoistureand
heatfromtheroomwhereitislocated.
Compared with wall mounted models, portable
airconditionershavetheadvantagethattheycan
bemovedfromoneroomtoanotherinthehome
orbetransportedfromonebuildingtoanother.
Hotairfromtheroomispassedthroughacoil
cooledbyrefrigerantgas.Excessheatandmoi-
sture are removed before the air is re-emitted
intotheroom.
Insingleunitmodels,asmallpartofthisairis
usedtocooltherefrigerantgasandthen,when
hotanddamp,isdischargedoutside.
In exclusive De’Longhi water-air models, the
heatisremovedfromtheroomthroughthecoo-
lingeffectofthewaterwhichisobviouslymuch
greaterthanair.
Thisgivesthisairconditionerunbeatablecooling
efciency.
WHAT IS THE PINGUINO INVERTER
TheInvertertechnologyhasbeendesignedtoof-
ferthebestcomfortwithoptimisedenergycon-
sumption.Itguaranteesveryhighcoolingpower
to rapidly reach the set temperature, which is
thenmaintainedconstantovertime.
Thistechnologyisessentiallybasedonanelec-
tronicdevicethatallowsfrequencyvariationsof
theelectricmotor,toadjusttherotationspeedof
thecompressorandobtainamodulationofthe
coolingpower.
ThisdeviceeliminatesthesequenceofOn–Off
requiredbyconventionalairconditionerstokeep
a xed room temperature, with consequential
high temperature uctuations around the set
temperature and longer time gaps before it is
reached.
The Pinguino Inverter always operates at the
optimum cooling capacity and the maximum
energy efciency as the powerconsumption is
limitedtoeffectiverequirements,bothinperiods
of average and low thermal load (morning or
evening), and during the hotter and more hu-
midtimes(middleoftheday),whentheInverter
technologyisespeciallyvaluable.
4
DESCRIPTION
A Airoutletgrille
B ControlpanelwithadvancedLCDdisplay
C Handle
D Grille
E Castors
F Airintakegrillewithdustlter
G Condensatedrainconnector
H Powercable
I Pullouttank
J Tankdoor
K Airexhausthose
L Remotecontrol
M Airexhausthosehousing
N Windowoutlet
O Silverionlter
P Electrostaticlter
Q Sucker
R Castorlocks(onlyonsomemodels)
S Flangewithcap
T Adjustablebar
U Waterdrainhose+cap
V Indicatorpaper
Z Dustlter
A
A
B
F
C
D
E
CC
J
I
G
H
K
L
M
N
O
P
Q
R
S
T
U
V
Z
5
Youcanalsousethe“adjustablebar”accessory
(T).
• Fit thewindowoutlet inthehousing inthe
bar(g.4)
• Position the bar on the window sill and
adjustuntilit tsintheguidesof theblind
(thelengthcanbeblockedwiththepinpro-
vided),thenlowertheblind(g.5).
• Fittheairhosetotheendofthewindowout-
let.
• Place theair conditionernear awindow or
Frenchwindow and connect theend ofthe
hose(g.7).
• Removethecapatthebackoftheappliance
(G)andreplacewiththedrainhosepluscap
(U)asshowningure6.
This enables the condensate to be drained
moreeasilyattheendoftheseason.
Seethesection:“ENDOFSEASONOPERA-
TIONS”.
PREPARING FOR USE
Theinstructionsbelowwillenableyoutoprepare
your airconditioner for operation as efciently
aspossible.
Beforeuse,make suretheairintakeand outlet
grillesareunobstructed.
Air-conditioning without installation
Justafewsimplestepsandyourcomfortisen-
suredwithyourappliance:
• Fittheairexhausthoseinthehousingatthe
backoftheappliance(g.1).
• Fitthe windowoutlet(N) to theendof the
hose(K).
• Placethe airconditioner near a window or
Frenchwindow.
• Adjust the length of the hose to reach the
window.
• Makesuretheairexhausthoseisunobstruc-
ted.
• OpenthewindoworFrenchwindowslightly
andpositiontheoutlet(g.2).
• Ifyouhaveadoublewindow,usethesucker
(Q)providedtoholdthetwopartsofthewin-
dowtogether(g.3).
1
2
1
2
1
2
2
3
4
5
1
6
Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
Air-conditioning with installation
Ifrequired,yourappliancecanbeinstalledsemi-
permanently(Fig.8).
Proceedasfollows:
• Drilla134mmdia.holeinanoutside wall
or through a window pane, respecting the
heightsshowning.9.
• Fittheangeaccessory(S)providedinthe
holefollowingtheindicationsings.10,11
and12.
12 inch
30 cm
30 cm
12 inch
MAX 39 inch
MIN 14 inch
inthewindowpane
inthewoodenkickboardofaFrenchwindow
inthewall:youarerecommendedtoinsulate
thesectionofwallusingsuitableinsulation.
• Fittheairexhausthose(K)inthehousingat
thebackoftheappliance
(g.1).
• Fittheendofthehosetotheange(S).
Whenthehoseisnottted,theholecanbe
closedwiththeangecap.
• Removethecapatthebackoftheappliance
(G)andreplacewiththedrainhosepluscap
(U) asshown ingure 6. This enables the
condensatetobedrainedmoreeasilyatthe
endoftheseason.Seethesection:“ENDOF
SEASONOPERATIONS”.
Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
When installing the air conditioner semi-
permanently, you should leave a door slightly
open, as little as 1 cm, to guarantee correct
ventilation.
1
2
8
10
11
12
9
134
5 inch
6
7
7
PREPARING FOR OPERATION IN
WATER MODE
Oncetheappliancehasbeeninstalled,itisready
foruse.
However,itsefciencycanbeenhancedbyope-
ratingitintheexclusiveDe’Longhiwatermode.
Thewaterinthetankincreasesthecoolingpo-
werofyourPinguinoandatthesametimeredu-
cesnoiselevelsandelectricalconsumption.
Comparedtoair,waterreducesthetemperature
ofthecoolingcircuitmuchmoreefciently,be-
forebeinggivenofffromtheairexhausthosein
theformofvapour.
Rememberthat:
• You mustalways usesalt-free cleanmains
water.
• Thelengthoftimethewaterinthetanklasts
depends greatly on environmental condi-
tionssuchastemperature,humidity,insula-
tion,theexposureoftheroom,thenumber
ofpeoplepresent,etc.
Indicativelyitlastsaboutsixhours.
TheBOOSTfunction(seepage30)shortens
theoperatingtimetoabout4hours,butthe
coolingpowerandefciencyareincreased.
• When the water in the tank runs out, the
light comesonandoperationofthe
applianceswitchesautomaticallytoair-air.
The appliance is fitted with a resin lime-
scale filter enabling normal tap water to be
used.
The impregnated resins reduce water hardness
and therefore prolong the working life of the
appliance.
CFis displayed when the limescale fil-
ter needs replacing. The efficacy of the filter
depends on water hardness.
Setting water hardness
Measurewaterhardnessusingtheindicatorpa-
perprovided.
•
Removetheindicatorpaperfromitspack(V).
• Immersethepapercompletelyinaglassof
waterforonesecond.
• Removethepaperfromthewaterandsha-
ke lightly. After about a minute, 1, 2, 3, 4
or 5 redsquaresappear, depending onthe
hardnessofthewater.Theappliancecanbe
set to three different waterhardness levels
soft(H1),medium(H2)andhard(H3).De-
terminethehardnessofthewateryouwillbe
usingbycomparingtheredsquaresonthe
indicatorpaperwiththetablebelow.
Tosetwaterhardness,proceedasfollows:
1. Settheappliancetostand-by.
2. Hold the FAN button on the control panel
downfor10seconds.Theapplianceemitsa
beepand
H1, H2 orH3isdisplayed.
3. Use the+or - buttonstoset the hardness
levelaccordingtothetableabove.Waitafew
secondsforthesettingtobememorized.The
applianceemitsanotherbeepandgoesback
tostand-by.
The appliance is set by default for medium
hardness (H2).
Filling the tank
The watertank is located at thebottom of the
appliance.Extractthetankbyinsertingthehand
through the door above the word “PULL” (g.
13)andpullingthetankoutasfarasitwillgo.
Removethecapanduseacontainer(bottle,jug,
wateringcan)topourinthewater(g.14/15).
Youcanseewhenthetankisfullthroughthel-
20
19
soft
Kind of water used Levels
H1
H2
H3
Medium
Hard
8
linghole.Itholdsamaximumof10litres.
Replacethecapcorrectlyandclosethetank,pu-
shingitinasfarasitwillgo.Thetankholehasa
meshltertopreventtheintroductionofforeign
matter.Ifnecessary,thisltercanbeunscrewed
andremovedforcleaningunderrunningwater.
Thetankdoesnothavetobefulltousethe
water function, but the length of time the
appliancewilloperateinwatermodewillbe
shorter.
Donotllabovetheleveloftheholetoavoid
thewateroverowing.Thetankhasnoover-
owpreventionsystem.
Replacing the limescale filter
Turn the appliance off and unplug from the
mains.
Makesurethereisnowaterintheapplianceby
emptyingthetankandinternaltrayasdescribed
inthesection:“Endofseasonoperations”.
Laytheapplianceonitsbackasshowningure
17.Restit onatowelorpieceofcardboard to
avoidscratchesordamage.Removethelterco-
verbyunscrewingthefourscrews(g.17).
Removethe lterdelicatelyandloosenthetwo
ties,makingsurethetwohosesconnectingthe
lterdonotslipinsidetheappliance.Fitthenew
lter, following the same procedure in reverse
(g. 16/15). The pawl on the lter (see gure)
indicatesthecorrectdirection.Thepawlmustal-
waysbetowardstheinsideoftheapplianceand
point“A”mustbefacingupwards.
Water may leak out while replacing the
limescale filter. You should therefore perform
the operation in a suitable location.
After replacing the filter, wait at least an hour
before starting the machine again.
When the filter has been replaced, turn the
alarm off by pressing the ON/STAND-BY
button (15) for 10 seconds.
The appliance emits a beep.
1
2
13
14
15
16
9
DESCRIPTION OF THE CONTROL
PANEL WITH ADVANCED LCD DISPLAY
1 Air conditioning symbol
2 Dehumidifying symbol
3 Fan symbol
4 SMART symbol
5 BOOST symbol
6 SLEEP symbol
7 Alarm symbol
8 Temperature indicator
9 “No water” symbol
10 Timer symbol
11 Speed indicator
12 AUTOFAN indicator
13 FAN button
14 Increase (+) and decrease (-) temperature
button
15 ON/Standby button
16
MODE button (selects the operating modes)
17 Signal receiver
OPERATING FROM THE CONTROL
PANEL
Thecontrolpanelenablesyoutomanageallthe
mainfunctionsoftheappliance.Tofullyexploit
its potential, you must use the remote control
unit.
Turning the appliance on
• Plugintothemainssocket.
Two lines appear on the display indicating
thattheapplianceisinstandby(g.20).
• Pressthebuttonuntiltheapplianceco-
meson.Thelastfunctionactivewhenitwas
turnedoffwillappear.
• Neverturntheairconditioneroffbyunplug-
gingfromthemains.Alwayspressthe
button, then wait for a few minutes before
unplugging.Thisallowstheappliancetoper-
formacycleofcheckstoverifyoperation.
Air conditioning mode (fig. 21)
Idealforhotmuggyweatherwhenyouneedto
coolanddehumidifytheroom.
Tosetthismodecorrectly:
• Pressthe MODEbutton a numberof times
1
2
6
7
8
5
9
10
11
3
4
12
16
14
13
17
15
17
18
19
20
Resin filter
Cover
10
untiltheair-conditioningsymbolappears.
• Select the target temperature by pressing
the orbuttonuntilthecorresponding
valueisdisplayed.
• Select the required fan speed by pressing
the button.
Fourspeedsareavailable:
Maximum speed: toachievethetarget
temperatureasrapidlyaspossible
Medium speed: reduces noise levels
butstillmaintainsagoodlevelofcomfort
Low speed:forsilentoperation
AUTOFAN: the appliance automatically
selectsthemostsuitablefanspeedinrelationto
thetemperaturesetonthedigitaldisplay.
The most suitable temperature for the room du-
ring the summer varies from 24 to 27°C.
You are recommended, however, not to set a
temperature much below the outdoor tempera-
ture.
Dehumidifying mode (fig. 22)
Ideal to reduce room humidity (spring and au-
tumn,damprooms,rainyperiods,etc).
Indehumidifyingmode,theapplianceshouldbe
preparedinthesamewayasforairconditioning,
withtheairexhausthoseattachedtoenablethe
moisturetobedischargedoutside.
Tosetthismodecorrectly:
• Pressthe MODEbutton a numberof times
untilthedehumidifyingsymbolappears.
In this mode, fan speed is selected automa-
tically by the appliance and cannot be set ma-
nually.
Fan mode (fig. 23)
Whenusing theapplianceinthismode, theair
hosedoesnotneedtobeattached.
Tosetthismodecorrectly:
• Pressthe MODEbutton a numberof times
untilthefansymbolappears.
• Select the required fan speed by pressing
the button.
Threespeedsareavailable:
High speed: formaximumfanpower
Medium speed: reduces noise levels
butstillmaintainsagoodlevelofcomfort.
Minimum speed: forsilentoperation
In this mode, AUTO speed cannot be selected.
21
22
1
2
6
7
8
5
9
10
11
3
4
12
16
14
13
17
15
1
2
3
4
5
8
10
12
11
15
16
19
20
21
22
23
24
18
17
14
13
9
7
6
1
2
3
4
5
8
10
12
11
15
16
19
20
21
22
23
24
18
17
14
13
9
7
6
23
11
SMART Mode (fig. 24)
SMARTmodetriestorecreateidealcomfortcon-
ditionsintheroom.Theapplianceautomatically
establishes whether to operate in air conditio-
ning, fan or stand-by mode depending on the
environmentalconditionsdetected.
Tosetthismode:
• Pressthe MODEbutton a numberof times
untiltheSMARTsymbolappears.
• Choosetherequiredfanspeed.
If in Air conditioning, Dehumidifying and
in the Smart mode function, the “No water”
symbol is displayed, it’s necessary to fill the
tank in order to obtain optimum performances.
DESCRIPTION OF THE REMOTE
CONTROL
1 Airconditioningsymbol
2 Dehumidifyingsymbol
3 Fansymbol
4 SMARTsymbol
5 Selectedtemperaturescaleindicator
6 Signaltransmission
7 BOOSTsymbol
8 SLEEPsymbol
9 AUTOFANindicator
10Fanspeedindicator
11TIMERONsymbol
12TimerOFFsymbol
13Clock
14ON/Standbybutton
15FANbutton
16Increase(+)anddecrease(-)buttons
17MODEbutton(selectsthemodes)
18Resetbutton(resetstheappliancetotheori-
ginalsettings)
19OKbutton
20TimerOFFbutton
21°Cor°Fselectionbutton
22SLEEPbutton
23BOOSTbutton
24TimerONbutton
1
2
3
4
5
8
10
12
11
15
16
19
20
21
22
23
24
18
17
14
13
9
7
6
24
12
USING THE REMOTE CONTROL
• Pointtheremote controlat thereceiver on
the appliance. The remote control must be
no morethan 7 metres away fromthe ap-
pliance (without obstacles between the re-
motecontrolandthereceiver).
• The remote control must be handled with
extremecare.Donotdropitorexposeitto
directsunlightorsourcesofheat.
Inserting or replacing the batteries
• Removethecoverontherearoftheremote
control(g.25);
• Inserttwo R03“AAA”1.5V batteries inthe
correctposition(seeinstructionsinsidethe
batterycompartment);
• Replacethecover.
Iftheremotecontrolunitisreplacedordi-
sposed of, the batteries must be removed
and discarded in accordance with current
legislation asthey are harmful to the envi-
ronment.
Donotmixalkaline,standard(zinc-carbon)
and rechargeable (nickel-cadmium) batte-
ries. Do not throw the batteries in the re
astheycouldexplodeorleakdangerousli-
quids.
Setting the time
Afterhavinginsertedthebatteries,theclockon
thedisplayashesuntilthetimeisset.
Proceedasfollows.
• Presstheorbuttonuntilthecorrect
timeisreached.
Holdthebuttondowntorunrapidlythrough
rsttheminutes,thenthetensofminutes.
• Oncethecorrecttimehasbeenreached,re-
leasethebuttonandpresstheOKbuttonto
conrm.
• To cancel the settings programmed on the
remotecontrolandrestoretheoriginalset-
tings,pressthebuttonlightlywiththe
pointofapencilorpen.
Operation of the remote control unit
Therstpartofthecontrolsontheremotecon-
trolarethesameasthoseonthecontrolpanel
oftheappliance(g.26).
Youshouldthereforerefertotheinstructionsin
the chapter OPERATING FROM THE CONTROL
PANELto
• turntheapplianceonoroff.
• selecttheoperatingmode(airconditioning,
dehumidifying, fan or Smart) and the fan
speed.
• settherequiredtemperature.
The following section describes the additional
functionscorresponding to thecontrolson the
bottompartoftheremotecontrol.
25
26
MAX. 7 metres
13
BOOST function (fig. 27)
Idealforthesummertocoolroomsrapidly.
Activatebysimplypressingthebutton.
Theapplianceoperatesinairconditioningmode
at maximum fan speed and maximum power.
Whilethisfunctionisselected,itisnotpossible
tosetthetemperatureorchangefanspeed.

When the BOOST function is active, the
water lasts less time than in air conditioning
mode. On the other hand, the cooling power
and efficiency of the appliance are higher.
Selecting the temperature scale
(fig. 28)
Pressthebuttontoswitchthetemperature
displayfrom°Cto°Fandviceversa.

Sleep function (fig. 29)
Thisfunctionisusefulforthenightasitgradual-
lyreducesoperationoftheappliance,turningit
offafter8hours.
Tosetthisfunctioncorrectly:
• Selecttheoperatingmode(airconditioning,
dehumidifying,smart)asdescribedabove.
• Pressthebutton.
The appliance operates in the previously
selectedmodewith thelowestpossiblefan
speed.
Fan speed is always at minimum, while room
temperatureandhumidityvarygraduallytoen-
surethemostcomfortableconditions.
During air conditioning, the temperature incre-
asesby1°Cafter60minutesandafurther1°C
after2hours.
In dehumidifying mode, the dehumidifying po-
wer of the appliance is partially reduced every
hourforthersttwohours.
/
27
28
29
14
If you needto disablethe timer onor off pro-
grammeinadvance,presstheorbut-
tonrespectivelytwice.
PROGRAMMING THE TIMER
Thetimercanbeprogrammedtostartandstop
theappliancewhenrequired.
Programming start up
• Pressthebutton.
Thestart-uptimeandsymbolashon
theremotecontroldisplay(g.30).
• Presstheorbuttonstosetthetime
youwanttheappliancetostartup.
• Whenthattimeisreached,presstheOKbut-
tontoconrm(g.31).Thesymbolre-
mainsdisplayedonthe remote control and
thesymbolisdisplayedontheapplian-
cetoindicatethatthetimerisactive.
Programming shutdown
• Pressthe OFFbutton.The shutdown
timeandsymbolashontheremote
controldisplay(g.32).
• Presstheorbuttonstosetthe
timeyouwanttheappliancetoshutdown.
• Whenthattimeisreached,presstheOKbut-
tontoconrm(g.33).Thesymbolre-
mainsdisplayedonthe remote control and
thesymbolisdisplayedontheapplian-
cetoindicatethatthetimerisactive.
30
32
31
33
15
SELF-DIAGNOSIS
Theappliancehasaselfdiagnosissystemtoidentifyanumberofmalfunctions.
Errormessagesaredisplayedontheappliancedisplay.
IF ... IS DISPLAYED, ...WHAT SHOULD I DO?
No water symbol
Change filter
Whenthismessageisdisplayed,thewaterlterneedsreplacingasdescribedinthe
section:“Replacingthelimescalelter”.
Low Temperature
(frostprevention)
Theappliance isttedwithafrostprotection deviceto avoidexcessive formation
ofice.Theappliancestartsupagainautomaticallywhenthedefrostingprocessis
completed.
Overheating
Theapplianceisttedwithasafetydevicetoavoidthecompressor’soverheating.Check
therearenoobstructiontotheairintake/outputgrilleortotheairexhausthose.
Theappliancewilloperatewiththefansonly,utillthetemperaturedecreasestothe
normalconditions,afterwards,theappliancewillautomaticallyoperateregularly.
Ifthealarmoftenoccurs,contactyourlocalauthorisedcustomerservices.
High Level
(internaltrayfull)
Emptytheinternalsafetytankfollowingtheinstructionsinthesection“Endofseason
operations”.Ifitreoccurs,contactyourlocalauthorisedcustomerservices.
Whenthewaterinthetankrunsout,the“nowatersymbol”comesonand
operationoftheapplianceswitchesautomaticallytoair-air.Atthesametime,the
quantityofairgivenoutfromtherearhoseincreases.Whenyoullthetankagain,
the“nowatersymbol”willdisappear.
IF ... IS DISPLAYED, ...WHAT SHOULD I DO?
Probe Failure
(sensordamaged)
Ifthisisdisplayed,contactyourlocalauthorisedservicecentre.
Failure 1
WhentheF1alarmisactive,theappliancecontinuesfunctioningnormallyinair-air
mode.
Toresetthealarm,unplugtheappliancethenplugitagain.
Ifthealarmoccursfrequently,contactyourlocalauthorisedcustomerservices.
Failure 2
(invertermodulefailure)
Ifthismessageisdisplayedandtheappliancestopworking,waitatleast15mins.
Ifthealarmpersistsandtheappliancedoesnotwork,unplugtheappliance,thenplug
itagain.
Ifthealarmoccursagain,contactyourlocalauthorisedcustomerservices.
Failure 3
(communicationfailure)
Ifthismessageisdisplayedandtheappliancestopworking,waitatleast15mins.
Ifthealarmpersistsandtheappliancedoesnotwork,unplugtheappliance,thenplug
itagain.
Ifthealarmoccursagain,contactyourlocalauthorisedcustomerservices.
16
TIPS FOR CORRECT USE
Togetthebestfromyourairconditioner,follow
theserecommendations:
• closethewindowsanddoorsintheroomto
beairconditioned(g.34).
Wheninstallingtheairconditionersemi-per-
manently, you should leave a door slightly
open(aslittleas1cm)toguaranteecorrect
ventilation.
• Protecttheroomfromdirectexposuretothe
sunbypartiallyclosingcurtainsand/orblin-
dstomaketheappliancemuchmoreecono-
micaltorun(g.35).
• neverrestobjectsofanykindontheaircon-
ditioner.
• donotobstructtheairintakeandoutlet(g.
36).Leavebothgrillesfree.
• makesuretherearenoheatsourcesinthe
room.
• neverusetheapplianceinverydamprooms
(laundriesforexample).
• neverusetheapplianceoutdoors.
• makesuretheairconditionerisstandingon
alevelsurface.
Ifnecessary,placethecastorlocksunderthe
frontwheels.
AIR PURIFYING FILTERS
Thisapplianceisttedwithasilverionlterand
adustltertomaintainefciency(g.37-38).
Thissilverionlterislocatedatthebackside
oftheapplianceintotheintakegrilleanditcan
houseanadditionalelectrostaticlter.
Thedustlterispositionedintothesidegrille.
closedoorsandwindows
closecurtains
donotcover
theappliance
34
35
36
37
38
17
Silver ion filter
Thislter,locatedinthebacksideoftheapplian-
ce,istreatedwithsilverionswhichnotjustretain
dustparticles,butalsohaveanefcientantibac-
terial action.It alsogreatly reduces concentra-
tionsofirritantssuchaspollenandspores.
Electrostatic filter
Theadditionalelectrostaticlterislocatedinthe
back of the appliance over the silver ion lter.
Thislterretainsthe nest dust particles, thus
enhancingthelteringcapacityoftheappliance.
Fitting the electrostatic filter to the rear
grille
Theappliancecanbe used with only thelters
alreadyinsertedinthegrilles.
Tousethesupplementaryelectrostaticlter,re-
moveitfromthepackagingandattachittothe
silverion,insertingitunderthespecialclips(g.
39).
Ifyoudecidenottouseit,keepitsealedinthe
packaging.
CLEANING
Beforecleaningormaintenance,turntheapplian-
ceoffbypressingthebuttononthecontrol
panelorremotecontrol,waitforafewseconds
thenunplugfromthemainssocket.
Cleaning the cabinet
You should clean the appliance with a slightly
dampcloththendrywithadrycloth.
• Donotwashtheairconditionerwithwater.It
couldbedangerous.
• Donotusepetrol,alcoholorsolventstocle-
antheappliance.
Donotsprayinsecticideliquidsorsimilar.
Cleaning the air filters
Tokeepyourairconditionerworkingefciently,
youshouldcleanthesilverionlterandthedust
ltereveryweekofoperation.
Eachlterishousedinthegrille.
Tocleanthelters,proceedasfollows:
• Removethegrillesbypullingthemoutwards
(g.37).
• Remove the lters by detachingthem from
the grilles (g. 38). To clean the silver ion
lter,theelectrostaticltermustbetempo-
rarilyremoved.
• Useavacuumcleaneratmediumpower,to
removethedustcollectedonthelters.
Iftheyareverydirty,immersetheminwarm
waterandrinseanumberoftimes.
• After washing, leave the lters to drycom-
pletely.
• Toreplace,puttheltersbackinthegrilles
thenattachthegrillestotheappliance.
Cleaning the electrostatic filter
The electrostatic lter is not washable but it
shouldbereplacedatleastonceeverytwose-
asons.
Theelectrostaticltercanbeboughtfromshops
sellingDe’Longhiaccessoriesorauthorisedser-
vicecentres.
Silverion
lter
39
Reargrille
Electrostatic
lter
18
START OF SEASON OPERATIONS
Makesurethepowercableandplugareundama-
gedandtheearthsystemisefcient.Followthe
installationinstructionsprecisely.
END OF SEASON OPERATIONS
Beforeputtingtheapplianceawayormovingit
toanotherlocation,emptyanywaterleftinthe
tanks.
Emptying the tank
Pull out the tank as described in the section:
“FILLINGTHETANK”.Unhookthedrainhoseon
theleftofthetank(g.40-41)andplacetheend
inarecipient.Removethecapanddrainoffthe
waterleftinthetank.
IMPORTANT:thetankcouldcontainasmuchas
10litresofwater.
Emptying the internal tank
Tofacilitatethisoperation,atthestartofthese-
ason, replacethe spoutcap (G) with the drain
hose+cap(U).
Placearecipient(suchasajugorbottle)near
thespoutonthebackoftheappliance(g.42).
Removethecapandrunoffanywaterleft.
Whencompletelyempty,replacethecap.
IMPORTANT: the internal tankcould contain as
muchas2litresofwater.
• After performing the 2 operations descri-
bedabove,operatetheapplianceinfanonly
modeforabouthalfanhour.Thisdriesany
waterremaininginsidetheappliance.
• Turntheappliance offandunplugfromthe
mains.
• Removetheairexhausthoseandcondensa-
tedrainhose.
• Cleanthedustlters.
• Covertheappliancetoavoiddust.
40
41
42
TECHNICAL CHARACTERISTICS
Powersupplyvoltage
Maximumabsorbedpower
inairconditioning
Refrigerant
Coolingcapacity
Limit conditions
Roomtemperatureforairconditioning21÷43°C
GUARANTEE
The terms oftheguarantee andtechnicalassi-
stance are given in the documentation accom-
panyingyourappliance.
seeratingplate
19
PROBLEM CAUSE SOLUTION
Theairconditioner
doesnotcomeon
• thereisnocurrent
• itisnotpluggedintothemains
• theinternalsafetydevicehastripped
• wait
• plugintothemains
• calltheServiceCentre
Theairconditioner
worksforashorttime
only
• therearebendsorkinksintheair
exhausthose
• somethingispreventingtheairfrom
beingdischarged
• positiontheairhosecorrectly,keeping
itasshortandfreeofcurvesaspossible
toavoidbottlenecks.
• checkandremoveanyobstacles
obstructingairdischarge
Theairconditioner
works,butdoesnot
cooltheroom
• windows,doorsand/orcurtainsopen
• thereareheatsourcesintheroom
(oven,hairdryer,etc)
• theairexhausthoseisdetachedfrom
theappliance
• dustltersclogged
•thetechnicalspecicationofthe
applianceisnotadequatefortheroom
inwhichitislocated.
• closedoors,windowsandcurtains,
bearinginmindthe“TIPSFOR
CORRECTUSE”givenabove
• eliminatetheheatsources
• ttheairexhausthoseinthehousingat
thebackoftheappliance(g.1).
• cleanorreplacetheltersasdescribed
above
Duringoperation,there
isanunpleasantsmell
intheroom
•dustlterandelectrostaticlterclogged • cleantheltersasdescribedabove
Theairconditioner
doesnotoperatefor
aboutthreeminutes
afterrestartingit
• theinternalcompressorsafetydevice
preventstheappliancefrombeing
restarteduntilthreeminuteshave
elapsedsinceitwaslastturnedoff.
• wait.Thisdelayispartofnormal
operation.
Thesymboland
oneofthefollowing
messages
Cf/ HL/ FI /F2/F3/PF
appearsonthe
appliancedisplay:
• Theappliancehasaselfdiagnosis
systemtoidentifyanumberof
malfunctions.
• SeetheSELF-DIAGNOSISchapter.
TROUBLESHOOTING
20
5715110781/06.11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

DeLonghi PAC 290 U Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI