G-Shock H-1 Owner's manual

Category
Water pumps
Type
Owner's manual

This manual is also suitable for

MO1408-EC
© 2013 CASIO COMPUTER CO., LTD.
E-1
ENGLISH
Congratulations upon your selection of this CASIO watch.
Applications
The built-in sensors of this watch measure direction, barometric pressure, temperature and altitude.
Measured values are then shown on the display. Such features make this watch useful when hiking,
mountain climbing, or when engaging in other such outdoor activities.
Warning !
The measurement functions built into this watch are not intended for taking measurements that
require professional or industrial precision. Values produced by this watch should be considered
as reasonable representations only.
When engaging in mountain climbing or other activities in which losing your way can create a
dangerous or life-threatening situation, always use a second compass to confi rm direction readings.
Note that CASIO COMPUTER CO., LTD. assumes no responsibility for any damage or loss
suffered by you or any third party arising through the use of this product or its malfunction.
E-2
Important!
Your watch’s Altimeter Mode calculates relative altitude based on changes in barometric pressure
measurement by its pressure sensor. For more information, see page E-36 and E-48.
Immediately before embarking or otherwise taking altitude readings, be sure to specify a reference
altitude. If you don’t the readings produced by the watch probably will not be very accurate. For more
information, see “To specify a reference altitude value” (page E-44).
E-3
About This Manual
Depending on the model of your watch, digital display text appears
either as dark fi gures on a light background, or light fi gures on a dark
background. All examples in this manual are shown using dark fi gures
on a light background.
Button operations are indicated using the letters shown in the
illustration.
Note that the product illustrations in this manual are intended for
reference only, and so the actual product may appear somewhat
different than depicted by an illustration.
E-4
Things to check before using the watch
1. Check the battery power level.
Is
H
or
M
indicated by the battery power indicator (page E-11)?
Go to step 2.
Power is low.
Charge the watch by placing it in a location
where it is exposed to light. For details, see “Charging the
Watch” (page E-10).
NO YES
YES
Does any one of the following conditions exist?
Battery power indicator indicates L and LOW is flashing on the
display.
CHG is flashing on the display.
The face is blank.
The watch is charged
sufficiently.
For details about
charging, see
“Charging the Watch”
(page E-10).
NEXT
Battery power
indicator
E-5
2. Check the Home City and the daylight saving time (DST) setting.
Use the procedure under “To confi gure Home City and summer time settings” (page E-31) to confi gure
your Home City and daylight saving time settings.
Important!
Proper time calibration signal reception, and World Time Mode and Sunrise/Sunset Mode data depend
on correct Home City, time, and date settings in the Timekeeping Mode. Make sure you confi gure
these settings correctly.
3. Set the current time.
To set the time using a time calibration signal
See “To get ready for a receive operation” (page E-17).
To set the time manually
See “Confi guring Current Time and Date Settings Manually” (page E-33).
The watch is now ready for use.
For details about the watch’s radio controlled timekeeping feature, see “Radio Controlled Atomic
Timekeeping” (page E-15).
E-6
Contents
E-3 About This Manual
E-4 Things to check before using the watch
E-10 Charging the Watch
E-14 To recover from the sleep state
E-15 Radio Controlled Atomic Timekeeping
E-17 To get ready for a receive operation
E-19 To perform manual receive
E-22 To check the latest signal reception results
E-22 To turn auto receive on or off
E-24 Mode Reference Guide
E-29 Timekeeping
E-30 Using Date/Time Records
E-31 Confi guring Home City Settings
E-31 To confi gure Home City and summer time settings
E-33 Confi guring Current Time and Date Settings Manually
E-33 To change the current time and date settings manually
E-35 Specifying Temperature, Barometric Pressure, and Altitude Display Units
E-35 To specify temperature, barometric pressure, and altitude display units
E-7
E-36 Using the Altimeter Mode
E-37 To select the altitude screen format
E-37 To select the altitude auto reading interval
E-39 To take altitude readings
E-42 To specify the altitude differential start point
E-43 To use the altitude differential value
E-44 To specify a reference altitude value
E-45 To save a reading manually
E-51 Precautions Concerning Simultaneous Altitude and Temperature Readings
E-52 Taking Direction Readings
E-52 To perform 2-point calibration
E-54 To take a direction reading
E-58 To perform magnetic declination correction
E-61 Taking Barometric Pressure and Temperature Readings
E-61 To take barometric pressure and temperature readings
E-66 To enable or disable the barometric pressure change alert
E-68 To calibrate the pressure sensor and the temperature sensor
E-70 Viewing Memory Records
E-70 To view data in watch memory
E-74 To delete all saved data
E-74 To delete a specifi c record
Operation Guide 3410
E-8
E-75 Checking the Current Time in a Different Time Zone
E-75 To enter the World Time Mode
E-75 To view the time in another time zone
E-76 To specify standard time or daylight saving time (DST) for a city
E-77 Using the Stopwatch
E-77 To enter the Stopwatch Mode
E-77 To perform an elapsed time operation
E-77 To pause at a split time
E-78 To measure two fi nishes
E-79 Using the Countdown Timer
E-79 To enter the Countdown Timer Mode
E-79 To specify the countdown start time
E-80 To perform a countdown timer operation
E-80 To stop the alarm
E-81 Using the Alarm
E-81 To enter the Alarm Mode
E-82 To set an alarm time
E-83 To turn an alarm and the Hourly Time Signal on and off
E-83 To stop the alarm
E-9
E-84 Looking up Sunrise and Sunset Times
E-84 To view sunrise and sunset times
E-85 To view the sunrise/sunset time for a particular date
E-86 To look up the sunrise and sunset times for a specifi c location
E-88 Illumination
E-88 To turn on illumination manually
E-88 To change the illumination duration
E-90 To turn the auto light switch on and off
E-92 Other Settings
E-92 To turn the button operation tone on and off
E-93 To turn Power Saving on or off
E-94 Troubleshooting
E-100 Specifi cations
E-10
Charging the Watch
The face of the watch is a solar panel that generates power from light. The generated power charges a
built-in rechargeable battery, which powers watch operations. The watch charges whenever it is exposed
to light.
Charging Guide
Whenever you are not wearing the
watch, leave it in a location where it
is exposed to light.
Best charging performance is
achieved by exposing the watch to
the strongest light available.
When wearing the watch, make sure
that its face is not blocked from light
by the sleeve of your clothing.
The watch may enter a sleep state
(page E-14) if its face is blocked
by your sleeve even only partially.
Warning!
Leaving the watch in bright light for charging can cause it to become quite hot.
Take care when handling the watch to avoid burn injury. The watch can become particularly hot
when exposed to the following conditions for long periods.
On the dashboard of a car parked in direct sunlight
Too close to an incandescent lamp
Under direct sunlight
E-11
Important!
Allowing the watch to become very hot can cause its liquid crystal display to black out. The
appearance of the LCD should become normal again when the watch returns to a lower temperature.
Turn on the watch’s Power Saving function (page E-14) and keep it in an area normally exposed to
bright light when storing it for long periods. This helps to ensure that power does not run down.
Storing the watch for long periods in an area where there is no light or wearing it in such a way that it is
blocked from exposure to light can cause power to run down. Expose the watch to bright light
whenever possible.
Power Levels
You can get an idea of the watch’s power level by observing the battery power indicator on the display.
Important!
If low battery power is indicated, expose the face of the watch to direct light to charge. At Level 5, the
battery is dead, which causes watch functions to stop, all data in watch memory to be deleted, and all
watch settings to return to their initial factory defaults.
Level Battery Power Indicator Function Status
1
(H)
All functions enabled.
2
(M)
All functions enabled.
Battery power
indicator
Battery power
indicator
E-12
Level Battery Power Indicator Function Status
3
(L)
l
l
l
l
l
l
l
l
l
l
l
Auto and manual receive, illumination,
beeper, and sensor operation disabled.
4
(CHG)
Except for the
CHG
(charge) indicator, all
functions and display indicators disabled.
5 – – – All functions disabled.
The fl ashing
LOW
indicator at Level 3 (L) tells you that battery power is very low, and that exposure to
bright light for charging is required as soon as possible.
Display indicators reappear as soon as the battery is charged from Level 5 to Level 2 (M).
Leaving the watch exposed to direct sunlight or some other very strong light source can cause the
battery power indicator to show a reading temporarily that is higher than the actual battery level. The
correct battery level should be indicated after a few minutes.
E-13
Power Recovery Mode
Performing multiple sensor, illumination, or beeper operations during a short period may cause all of
the battery power indicators (H, M, and L) to start fl ashing on the display. This indicates that the watch
is in the power recovery mode. Illumination, alarm, countdown timer alarm, hourly time signal, and
sensor operations will be disabled until battery power recovers.
Battery power will recover in about 15 minutes. At this time, the battery power indicators (H, M, L) will
stop fl ashing. This indicates that the functions listed above are enabled again.
If all of the battery power indicators (H, M, L) are fl ashing and the
CHG
(charge) indicator also is
ashing, it means the battery level is very low. Expose the watch to bright light as soon as possible.
Even if battery power is at Level 1 (H) or Level 2 (M), the Digital Compass Mode, Barometer/
Thermometer Mode, or Altimeter Mode sensor may be disabled if there is not enough voltage available
to power it suffi ciently. This is indicated when all of the battery power indicators (H, M, L) are fl ashing.
Frequent fl ashing of all of the battery power indicators (H, M, L) probably means that remaining battery
power is low. Leave the watch in bright light to allow it to charge.
Charging Times
Exposure Level (Brightness)
Daily
Operation
*1
Level Change *2
Level 5 Level 4 Level 3 Level 2 Level 1
Outdoor sunlight (50,000 lux) 5 min. 2 hours 16 hours 5 hours
Sunlight through a window (10,000 lux)
24 min. 7 hours 79 hours 22 hours
Daylight through a window on a
cloudy day (5,000 lux)
48 min. 12 hours 160 hours 43 hours
Indoor fl uorescent lighting (500 lux) 8 hours 175 hours – – – – – –
E-14
*1 Approximate amount of exposure time required each day to generate enough power for normal daily
operation.
*2 Approximate amount of exposure time (in hours) required to take power from one level to the next.
The above exposure times all are for reference only. Actual exposure times depend on lighting
conditions.
For details about the operating time and daily operating conditions, see the “Power Supply” section of
the Specifi cations (page E-103).
Power Saving
When turned on, Power Saving enters a sleep state automatically whenever the watch is left for a certain
period in an area where it is dark. The table below shows how watch functions are affected by Power
Saving.
For information about enabling and disabling power saving, see “To turn Power Saving on or off” (page
E-93).
There actually are two sleep state levels: “display sleep” and “function sleep”.
Elapsed Time in Dark Display Operation
60 to 70 minutes (display sleep) Blank, with
PS
ashing Display is off, but all functions are enabled.
6 or 7 days (function sleep) Blank, with
PS
not fl ashing
All functions are disabled, but timekeeping is
maintained.
The watch will not enter a sleep state between 6:00 AM and 9:59 PM. If the watch is already in a sleep
state when 6:00 AM arrives, however, it will remain in the sleep state.
Power Saving is enabled only when the watch is in the Timekeeping Mode with the Day of the Week
screen displayed (page E-29) or in the World Time Mode (page E-75).
To recover from the sleep state
Move the watch to a well-lit area, press any button, or angle the watch towards your face for reading (page E-89).
E-15
Radio Controlled Atomic Timekeeping
This watch receives a time calibration signal and updates its time setting accordingly. However, when
using the watch outside of areas covered by time calibration signals, you will have to adjust the settings
manually as required. See “Confi guring Current Time and Date Settings Manually” (page E-33) for more
information.
This section explains how the watch updates its time settings when the city code selected as the Home
City is in Japan, North America, Europe, or China, and is one that supports time calibration signal
reception.
If your Home City Code setting is this:
The watch can receive the signal from the transmitter
located here:
LIS, LON, MAD, PAR, ROM, BER, STO, ATH, MOW Anthorn (England), Mainfl ingen (Germany)
HKG, BJS Shangqiu City (China)
TPE, SEL, TYO Fukushima (Japan), Fukuoka/Saga (Japan)
HNL, ANC, YVR, LAX, YEA, DEN, MEX, CHI, NYC, YHZ,
YYT
Fort Collins, Colorado (United States)
Important!
The areas covered by
MOW
,
HNL
and
ANC
are quite far from the calibration signal transmitters, so
certain conditions may cause reception problems.
When
HKG
or
BJS
is selected as the Home City, only the time and date are adjusted according to the
time calibration signal. You need to switch manually between standard time and daylight saving time
(DST) if required. See “To confi gure Home City and summer time settings” (page E-31) for information
about how to do this.
Operation Guide 3410
E-16
Approximate Reception Ranges
UK and German Signals
Anthorn
500 kilometers
1,500 kilometers
The Anthorn signal is
receivable within this area
Mainflingen
North American Signal
Japanese Signals Chinese Signal
500 kilometers
Changchun
Beijing
Shangqiu
Shanghai
Chengdu
Hong Kong
1,500 kilometers
2,000 miles
(3,000 kilometers)
600 miles
(1,000 kilometers)
Fort Collins
1,000 kilometers
Signals are receivable in the Taiwan area
when reception conditions are
g
ood.
For the Honolulu and Anchorage time zones, the
signal can be received when reception conditions
are favorable.
Fukuoka/Saga
500 kilometers
Fukushima
E-17
Even when the watch is within range of a transmitter, signal reception may be impossible due to the
effects of geographic contours, structures, weather, the time of year, the time of day, radio interference,
etc. The signal becomes weaker at distances of approximately 500 kilometers, which means that the
infl uence of the conditions listed above becomes even greater.
Signal reception may not be possible at the distances noted below during certain times of the year or
day. Radio interference may also cause problems with reception.
Mainfl ingen (Germany) or Anthorn (England) transmitters: 500 kilometers (310 miles)
Fort Collins (United States) transmitter: 600 miles (1,000 kilometers)
Fukushima or Fukuoka/Saga (Japan) transmitters: 500 kilometers (310 miles)
Shangqiu (China) transmitter: 500 kilometers (310 miles)
As of December 2012, China does not use Daylight Saving Time (DST). If China does go to the Daylight
Saving Time system in the future, some functions of this watch may no longer operate correctly.
To get ready for a receive operation
1. Confi rm that the watch is in the Timekeeping Mode or World Time Mode. If it isn’t, use
D
to enter the
Timekeeping Mode or World Time Mode (page E-26).
2. The antenna of this watch is located on its 12 o’clock side. Position the watch with 12 o’clock facing
towards a window as shown in the nearby illustration. Make sure there are no metal objects nearby.
Signal reception normally is better at night.
The receive operation takes from two to ten minutes, but
in some cases it can take as long as 20 minutes. Take
care that you do not perform any button operation or
move the watch during this time.
12 o’clock
or
12 o’clock
or
E-18
Signal reception may be diffi cult or even impossible under the conditions described below.
Inside or
among
buildings
Inside a
vehicle
Near
household
appliances,
offi ce
equipment,
or a mobile
phone
Near a
construction
site, airport
Near
high-tension
power lines
Among or
behind
mountains
3. What you should do next depends on whether you are using auto receive or manual receive.
Auto receive: Leave the watch over night in the location you selected in step 2. See “Auto Receive”
below for details.
Manual receive: Perform the operation under “To perform manual receive” on page E-19.
Auto Receive
With auto receive, the watch performs the receive operation each day automatically up to six times (up
to fi ve times for the Chinese calibration signal) between the hours of midnight and 5 a.m. (according to
the Timekeeping Mode time). When any receive operation is successful, none of the other receive
operations for that day are performed.
When a calibration time is reached, the watch will perform the receive operation only if it is in the
Timekeeping Mode or World Time Mode. The receive operation is not performed if a calibration time is
reached while you are confi guring settings.
E-19
You can use the procedure under “To turn auto receive on and off” (page E-22) to enable or disable
auto receive.
To perform manual receive
1. Use
D
to select the Receive Mode (
R/C
) as shown on page E-26.
2. Hold down
A
until
RC Hold
appears on the display and then
disappears.
A signal level indicator (L1, L2, or L3, see page E-21) will appear
on the display after reception starts. Do not allow the watch to
move and do not perform any button operation until GET or ERR
appears on the display.
If the receive operation is successful, the reception date and time
appear on the display, along with the GET indicator.
The watch will return to the Timekeeping Mode if you press
D
or
if you do not perform any button operation for about two or three
minutes.
Receiving
Receiving indicator
Receive successful
Receiving
Receiving indicator
Receive successful
E-20
If the current reception fails but a previous reception (within the
last 24 hours) was successful, the display shows the receiving
indicator and the ERR indicator. If the ERR indicator only is
displayed (without the receiving indicator), it means that all of the
receive operations over the past 24 hours have failed.
The watch will return to the Timekeeping Mode without changing
the time setting if you press
D
or if you do not perform any button
operation for about two or three minutes.
Note
You can interrupt a time calibration signal reception operation by
pressing any button.
Receive failed
If there was a previously
successful reception
Receive failed
If there was a previously
successful reception
E-21
Signal Level Indicator
During manual receive, the signal level indicator displays the signal level
as shown below.
Weak (Unstable) Strong (Stable)
The level indication will change in accordance with reception conditions
while reception is being performed.
As you watch the indicator, keep the watch in a location that best
maintains stable reception.
Even under optimum reception conditions, it can take about 10
seconds for reception to stabilize.
Note that weather, the time of day, surroundings, and other factors all
can affect reception.
E-22
To check the latest signal reception results
Enter the Receive Mode (page E-26).
When receive is successful, the display shows the time and date that
receive was successful.
- : - -
indicates that none of the reception
operations were successful.
To return to the Timekeeping Mode, press
D
.
To turn auto receive on or off
1. Enter the Receive Mode (page E-26).
2. Hold down
E
for at least two seconds. Release
E
after
AUTO
appears. This is the setting screen.
Note that the setting screen will not appear if the currently selected
Home City is one that does not support time calibration reception.
3. Press
A
to toggle auto receive between on (
On
) and off (
OFF
).
4. Press
E
to exit the setting screen.
On/Off statusOn/Off status
E-23
Radio-controlled Atomic Timekeeping Precautions
Strong electrostatic charge can result in the wrong time setting.
Even if a receive operation is successful, certain conditions can cause the time setting to be off by up
to one second.
The watch is designed to update the date and day of the week automatically for the period January 1,
2000 to December 31, 2099. Updating of the date by signal reception will no longer be performed
starting from January 1, 2100.
If you are in an area where signal reception is not possible, the watch keeps time with the precision
noted in “Specifi cations”.
The receive operation is disabled under any of the following conditions.
– While power is at Level 3 (L) or lower (page E-11)
– While the watch is in the power recovery mode (page E-13)
– While a direction, barometric pressure/temperature, or altitude reading operation is in progress
– When the watch is in the function sleep state (“Power Saving”, page E-14)
– While the barometric pressure change indicator is displayed
– While a countdown timer operation is in progress (page E-79)
A receive operation is cancelled if an alarm sounds while it is being performed.
The Home City setting reverts to the initial default of
TYO
(Tokyo) whenever the battery power level
drops to Level 5 or when you have the rechargeable battery replaced. If this happens, change the
Home City to the setting you want (page E-31) .
Operation Guide 3410
E-24
Mode Reference Guide
Your watch has 11 “modes”. The mode you should select depends on what you want to do.
To do this: Enter this mode: See:
View the current date in the Home City
Confi gure Home City and daylight saving time (DST) settings
Confi gure time and date settings manually
Record the current date and time
Timekeeping Mode E-29
View the altitude at your current location
Determine the altitude differential between two locations (reference
point and current location)
Record the current altitude reading along with the reading date and time
Altimeter Mode E-36
Determine your current bearing or the direction from your current
location to a destination
Record the current direction reading along with the reading date and time
Digital Compass Mode E-52
View the barometric pressure and temperature at your current location
View a graph of barometric pressure readings
View barometric pressure tendency information
Record the current barometric pressure and readings along with the
reading date and time
Barometer/Thermometer
Mode
E-61
View the current time in one of 48 cities (31 time zones) around the globe World Time Mode E-75
Use the stopwatch to measure elapsed time Stopwatch Mode E-77
Use the countdown timer Countdown Timer Mode E-79
Set an alarm time Alarm Mode E-81
E-25
To do this: Enter this mode: See:
View the sunrise and sunset times for a specifi c date Sunrise/Sunset Mode E-84
Recall time, direction reading, barometric pressure/temperature
reading, and altitude reading data
Data Recall Mode E-70
Perform a manual time calibration signal receive operation
Check whether the last receive operation was successful
Confi gure auto receive settings
Receive Mode E-19
E-26
Selecting a Mode
The illustration below shows which buttons you need to press to navigate between modes.
To return to the Timekeeping Mode from any other mode, hold down
D
for about two seconds.
In the Timekeeping Mode, press
A
to enter the Stopwatch Mode (page E-77).
Countdown
Timer Mode
Alarm Mode
Stopwatch Mode
World Time
Mode
Receive Mode
Timekeeping Mode
Sunrise/Sunset
Mode
Data Recall
Mode
Countdown
Timer Mode
Alarm Mode
Stopwatch Mode
World Time
Mode
Receive Mode
Timekeeping Mode
Sunrise/Sunset
Mode
Data Recall
Mode
E-27
Sensor Modes
Altimeter Mode
Barometer/
Thermometer Mode
Digital Compass Mode
Sensor Modes
Altimeter Mode
Barometer/
Thermometer Mode
Digital Compass Mode
This watch has three “sensor modes”: Altimeter Mode, Digital Compass Mode, and Barometer/
Thermometer Mode. Press the
B
button to display a sensor mode screen.
The sensor mode that was displayed when you last returned to the Timekeeping Mode will appear fi rst.
E-28
General Functions (All Modes)
The functions and operations described in this section can be used in all of the modes.
Auto Return Features
The watch will automatically return to the Timekeeping Mode if you do not perform any button operation
for a particular amount of time in each mode.
Mode Name Approximate Elapsed Time
Sunrise/Sunset, Data Recall, Alarm, Receive, Digital
Compass
3 minutes
Altimeter 1 hour minimum
12 hours maximum
Barometer/Thermometer 1 hour
Setting screen (digital setting fl ashing) 3 minutes
If you leave a screen with fl ashing digits on the display for two or three minutes without performing any
operation, the watch exits the setting screen automatically.
Initial Screens
When you enter the Data Recall, Alarm, World Time, or Digital Compass Mode, the data you were viewing
when you last exited the mode appears fi rst.
Scrolling
The
A
and
C
buttons are used on the setting screen to scroll through data on the display. In most
cases, holding down these buttons during a scroll operation scrolls through the data at high speed.
E-29
Timekeeping
Use the Timekeeping Mode (
TIME
) to set and view the current time and date.
Each press of
E
in the Timekeeping Mode will change screen contents as shown below.
Day of the Week Screen Barometric Pressure
Graph Screen
Barometric pressure graph
Day of week
Seconds
Hour :
Minutes
Month - Day
PM
indicator
Graphic (seconds)*
* The graphic appears as the pattern shown below when a stopwatch elapsed time
operation is in progress or paused (page E-77).
C
E-30
Using Date/Time Records
You can use the procedure in this section to create a date/time record of the current date (month, day,
year) and time (minute second). You can later recall a record to view it.
Important!
The watch has memory for storage of up to 40 records of various types. If you perform an operation
that creates a new record while there are already 40 records in memory, the oldest record is deleted
automatically to make room for the new one (page E-70).
1. In the Timekeeping Mode, hold down
C
until the watch beeps (about 0.5 seconds).
REC will appear on the display, indicating that a record of the current date and time was created.
After about one second, the watch will return to the Timekeeping Mode screen.
2. To view a record, enter the Data Recall Mode (page E-26) and use the
A
and
C
buttons to scroll. See
“Viewing Memory Records” (page E-70) for more information.
E-31
Confi guring Home City Settings
There are two Home City settings: actually selecting the Home City and selecting either standard time or
daylight saving time (DST).
To confi gure Home City and summer time settings
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the display fi rst, and then
Hold
will
disappear. Release
E
after
Hold
disappears.
The watch will exit the setting mode automatically if you do not
perform any operation for about two or three minutes.
For details about city codes, see the “City Code Table” at the back
of this manual.
2. Use
A
(East) and
C
(West) to scroll through the available city codes.
Keep scrolling until the city code you want to select as your Home
City is displayed.
3. Press
D
to display the DST setting screen.
4.
Use
A
to cycle through the DST settings in the sequence shown below.
Auto DST (AUTO) DST off (OFF)
DST on (
ON
)
City code
DST indicator
City code
DST indicator
Operation Guide 3410
E-32
The Auto DST (AUTO) setting will be available only when a city code that supports time calibration
signal reception (page E-15) is selected as the Home City. While Auto DST is selected the DST
setting will be changed automatically in accordance with time calibration signal data.
Note that you cannot switch between standard time and daylight saving time (DST) while UTC is
selected as your Home City.
5. After all of the settings are the way you want, press
E
twice to exit the setting screen.
Daylight Saving Time is turned on when the DST indicator is on the display.
Note
After you specify a city code, the watch will use UTC* offsets in the World Time Mode to calculate
the current time for other time zones based on the current time in your Home City.
* Coordinated Universal Time, the world-wide scientifi c standard of timekeeping.
The reference point for UTC is Greenwich, England.
Selecting some city codes automatically makes it possible for the watch to receive the time
calibration signal for the corresponding area. See page E-15 for details.
E-33
Confi guring Current Time and Date Settings Manually
You can confi gure current time and date settings manually when the watch is unable to receive a time
calibration signal.
Important!
Before confi guring current time and date settings, be sure set your Home City (page E-31).
To change the current time and date settings manually
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the display fi rst, and then
Hold
will
disappear. Release
E
after
Hold
disappears.
2. Press
D
to move the fl ashing in the sequence shown below to select
the other settings.
Thermometer/Barometer/
Altitude display unit
(page E-35)
Power
Saving
(page E-93)
Illumination
Duration
(page E-88)
Button Operation
Tone
(page E-92)
Day
Month
City Code
(page E-31)
DST
(page E-31)
12/24-Hour
Format
Seconds Hour Minutes Year
City codeCity code
E-34
3. When the timekeeping setting you want to change is fl ashing, use
A
and/or
C
to change it as
described below.
Screen To do this: Do this:
Toggle between 12-hour (
12H
) and 24-hour (
24H
)
timekeeping.
Press
A
.
Reset the seconds to
00
(If the current seconds count is between 30 and 59,
one is added to the minute count).
Press
A
.
Change the hour or minutes
Use
A
(+) and
C
(–).
Change the year, month, or day
4. After all of the settings are the way you want, press
E
twice to exit the setting screen.
Note
While the 12-hour format is selected for timekeeping, a P (PM) indicator will appear for times from
noon to 11:59 p.m. No indicator appears for times from midnight to 11:59 a.m. With 24-hour format,
time is displayed from 0:00 to 23:59, without any P (PM) indicator.
The watch’s built-in full automatic calendar makes allowances for different month lengths and leap
years. Once you set the date, there should be no reason to change it except after you have the
watch’s rechargeable battery replaced or after power drops to Level 5 (page E-11).
The day of the week changes automatically when the date changes.
E-35
Specifying Temperature, Barometric Pressure, and Altitude Display Units
Use the procedure below to specify the temperature, barometric pressure, and altitude display units to be
used in the Barometer/Thermometer Mode and the Altimeter Mode.
Important!
When
TYO
(Tokyo) is selected as the Home City, the altitude unit is set
automatically to meters (
m
), the barometric pressure unit to
hectopascals (
hPa
), and the temperature unit to Celsius (
°C
). These
settings cannot be changed.
To specify temperature, barometric pressure, and altitude display
units
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the display fi rst, and then
Hold
will
disappear. Release
E
after
Hold
disappears.
2. Press
D
as many times as necessary until
UNIT
appears on the display (page E-33).
3. Perform the operations below to specify the display units you want.
To specify this unit: Press this key: To toggle between these settings:
Altitude
A
m
(meters) and
ft
(feet)
Barometric Pressure
B
hPa
(hectopascals) and
inHg
(inches of mercury)
Temperature
C
°C
(Celsius) and
°F
(Fahrenheit)
4. After all of the settings are the way you want, press
E
twice to exit the setting screen.
E-36
Using the Altimeter Mode
The watch takes altitude readings and displays results based on air pressure measurements taken by a
built-in pressure sensor. It also saves various types of altitude records and data.
Getting Ready
Before actually taking an altitude reading you need to select an altitude screen format and select an
altitude reading interval.
Selecting the Altitude Screen Format
You can select either of two screen formats for the Altimeter Mode.
Screen 1
Altitude
Tendency Graph
Altitude
Current time
Screen 2
Relative altitude
Altitude
Current time
Altitude tendency graph contents are updated each time you take an altitude reading.
To take readings of the difference between the altitude at your current location and the altitude at a
reference point, select Screen 2. See “Using an Altitude Differential Value” (page E-42) for more
information.
E-37
To select the altitude screen format
1. Enter the Altimeter Mode (page E-27).
2. Use
E
to toggle the setting between the two screens.
Selecting the Altitude Auto Reading Interval
You can select either of the following two altitude auto reading intervals.
0’05
: Readings at one-second intervals for the fi rst three minutes, and then every fi ve seconds for
approximately the next hour
2’00
: Readings at one-second intervals for the fi rst three minutes, and then every two minutes for
approximately the next 12 hours
Note
If you do not perform any button operation while in the Altimeter Mode, the watch will return to the
Timekeeping Mode automatically after 12 hours (altitude auto reading interval: 2’00) or after one
hour (altitude auto reading interval: 0’05).
To select the altitude auto reading interval
1. In the Altimeter Mode, hold down
E
for at least two seconds. You can
release
E
after
ALTI
appears.
The current altitude reading value will appear at this time.
2. Press
D
to display the current altitude auto reading interval setting.
The display will show
0’05
or
2’00
.
3. Press
A
to toggle the altitude auto reading interval setting between
0’05
and
2’00
.
4. Press
E
to exit the setting screen.
E-38
Taking Altitude Readings
Use the procedure below to take basic altitude readings.
See “Using Reference Altitude Values” (page E-44) for information about how to make altimeter
readings more accurate.
See “How does the altimeter work?” (page E-48) for information about how the watch measures altitude.
E-39
To take altitude readings
Enter the Altimeter Mode (page E-27).
This will automatically start an altitude reading operation, and the result
will appear on the display as a value in 1-meter (5-foot) units.
Readings will continue to be taken about every second for the fi rst
three minutes. For information about the reading interval after that, see
page E-37.
You can restart the reading operation from the beginning at any time
by pressing
C
.
Note
After you are fi nished, press
D
to return to the Timekeeping Mode and
stop auto altimeter readings.
The watch will return to the Timekeeping Mode automatically if you do
not perform any operation (page E-28).
The measurement range for altitude is –700 to 10,000 meters (–2,300
to 32,800 feet).
The displayed altitude value changes to
- - - -
if an altitude reading
falls outside the measurement range. An altitude value will reappear as
soon as the altitude reading is within the allowable range.
Normally, displayed altitude values are based on the watch’s preset
conversion values. You also can specify a reference altitude value, if
you want. See “Using Reference Altitude Values” (page E-44).
You can change the unit for displayed altitude values to either meters
(m) or feet (ft). See “To specify temperature, barometric pressure, and
altitude display units” (page E-35).
Screen 1 Selected
Altitude
Tendency
Graph
Altitude
Differential
Graph
Altitude
Current
time
Screen 1 Selected
Altitude
Tendency
Graph
Altitude
Differential
Graph
Altitude
Current
time
Screen 2 Selected
Relative
altitude
Altitude
Differential
Graph
Altitude
Current
time
Screen 2 Selected
Relative
altitude
Altitude
Differential
Graph
Altitude
Current
time
Operation Guide 3410
E-40
Checking the Latest Changes in Altitude
The altitude differential graph shows the difference between the currently displayed altitude reading
and the previous reading during while readings are being taken automatically.
0
–30m
+30m
+10m +20m
+18m
31 meters or greater
–4m
–10m –20m
No
difference
Example
E-41
The altitude tendency graph shows changes in altitude over the past 20 readings while readings are
being taken automatically.
80 meters
(10 meters for
each block )
20 readings
ago
10 readings
ago
Current
reading
Advanced Altimeter Mode Operations
Use the information in this section to obtain more accurate altimeter readings, especially while mountain
climbing or trekking.
E-42
Using an Altitude Differential Value
The Altimeter Mode screen has an altitude differential value that shows
the change in altitude from a reference point you specify. The altitude
differential value is updated each time the watch takes an altitude reading.
The range of the altitude differential value is –3,000 meters (–9,995
feet) to 3,000 meters (9,995 feet).
- - - -
is displayed in place of the altitude differential value whenever
the measured value is outside the allowable range.
See “Using the Altitude Differential Value While Mountain Climbing or
Hiking” (page E-43) for some real-life examples of how to use this
feature.
To specify the altitude differential start point
1. In the Altimeter Mode, select Screen 2 as the Altimeter Mode display
(page E-37).
2. Press
A
.
The watch will take an altitude reading and register the result as
the altitude differential value start point. The altitude differential
value will be reset to zero at this time.
Altitude differentialAltitude differential
Altitude differentialAltitude differential
E-43
Using the Altitude Differential Value While Mountain Climbing or Hiking
After you specify the altitude differential start point while mountain climbing or hiking, you can easily
measure the change in the altitude between that point and other points along the way.
To use the altitude differential value
1. In the Altimeter Mode, check to make sure that an altitude reading is
on the display.
If an altitude reading is not displayed, press
C
to take one. See “To
take altitude readings” (page E-39) for details.
2. Use the contour lines on your map to determine the difference in
altitude between your current location and your destination.
3. In the Altimeter Mode, press
A
to specify your current location as the
altitude differential start point.
The watch will take an altitude reading and register the result as
the altitude differential value start point. The altitude differential
value will be reset to zero at this time.
4. While comparing the altitude difference you determined on the map
and the watch’s altitude differential value, advance towards your
destination.
If the map shows that the difference in altitude between your
location and your destination is +80 meters for example, you know
you will be nearing your destination when the displayed altitude
differential value shows +80 meters.
Current
location
Destination
altitude
Current
location
Destination
altitude
Altitude
Altitude
differential
Altitude
Altitude
differential
E-44
Using Reference Altitude Values
To minimize the chance of reading error, you should update the reference altitude value before setting off
on a trek or any other activity where you plan to take altitude readings. During a trek, keep checking the
readings produced by the watch against altitude information provided by markers and other information,
and update the reference altitude value as required.
Reading error can be caused by changes in barometric pressure, atmospheric conditions, and
elevation.
Before performing the procedure below, look up the altitude of your current location on a map, the
Internet, etc.
To specify a reference altitude value
1. In the Altimeter Mode, hold down
E
for at least two seconds. You can
release
E
after
ALTI
appears.
The current altitude reading value will appear at this time.
2. Use
A
(+) or
C
(–) to change the current reference altitude value in
1-meter (5-foot) increments.
Change the reference altitude value to an accurate altitude reading
that you get from a map or other source.
You can set the reference altitude value within the range of –10,000
to 10,000 meters (32,800 to 32,800 feet).
Pressing
A
and
C
at the same time returns to OFF (no reference
altitude value), so the watch performs air pressure to altitude
conversions based on preset data only.
3. Press
E
to exit the setting screen.
E-45
Types of Altitude Data
Your watch stores two types of altitude data: altitude records and historical altitude values.
Manually Saved Records
Each altitude reading you take manually is stored along with the date and time of the reading as an
“altitude record”. You can later recall an altitude record to view it.
Important!
The watch has memory for storage of up to 40 records of various types. If you perform an operation
that creates a new record while there are already 40 records in memory, the oldest record is deleted
automatically to make room for the new one (page E-70). Note that altitude differential graph and
altitude tendency graph information is not stored as part of an altitude record.
To save a reading manually
1. In the Altimeter Mode, hold
C
for at least two seconds.
REC
and
Hold
will appear on the display fi rst, and then
Hold
will
disappear. Release
C
after
Hold
disappears.
The watch will create a record of the current altitude reading along
with the date and time, and then return automatically to the altitude
reading screen.
2. To view a record, enter the Data Recall Mode (page E-26) and use the
A
and
C
buttons to scroll. See “Viewing Memory Records” (page
E-70) for more information.
E-46
Auto Save Values
The watch automatically keeps track of the four types of values below, and updates them as required
along with the time and date of the reading.
High Altitude (MAX)
Low Altitude (MIN)
Cumulative Ascent (ASC)
Cumulative Descent (DSC)
For detailed information about each value, see page E-47.
For information about viewing these values, see “Viewing Memory Records” (page E-70).
These values are checked and updated automatically by the watch as altitude auto measurements are
taken. You can change the auto save interval, if you want (page E-37).
Auto save is performed only while the watch is in the Altimeter Mode.
E-47
How Cumulative Ascent and Cumulative Descent Values Are Updated
Session start point
20 m
0 m
120 m
320 m
620 m
Session end point
The total ascent and total descent values produced by an Altimeter Mode reading operation session
during the example climb illustrated above are calculated as follows.
Total Ascent:
q
(300 m) +
e
(620 m) = 920 m
Total Descent:
w
(320 m) +
r
(500 m) = 820 m
Cumulative ascent and cumulative descent values are updated whenever there is a difference of at
least ±15 meters (±49 feet) from one reading to the next.
ASC
and
DSC
values are retained in memory without being reset even if you exit the Altimeter Mode.
When you re-enter the Altimeter Mode, accumulation resumes from the value where it last stopped. See
page E-74 for information about how to reset the
ASC
and
DSC
values to zero.
Operation Guide 3410
E-48
How does the altimeter work?
Generally, air pressure decrease as altitude increases. This watch bases its altitude reading on
International Standard Atmosphere (ISA) values stipulated by the International Civil Aviation Organization
(ICAO). These values defi ne relationships between altitude and air pressure.
0 m
500 m
1000 m
1500 m
2000 m
2500 m
3000 m
3500 m
4000 m
899 hPa
795 hPa
701 hPa
616 hPa
1013 hPa
About 8 hPa per 100 m
About 9 hPa per 100 m
About 10 hPa per 100 m
About 11 hPa per 100 m
About 12 hPa per 100 m
Altitude Air Pressure
0 ft.
2000 ft.
4000 ft.
6000 ft.
8000 ft.
10000 ft.
12000 ft.
14000 ft.
25.84 inHg
22.23 inHg
19.03 inHg
29.92 inHg
About 0.15 inHg per 200 ft.
About 0.17 inHg per 200 ft.
About 0.192 inHg per 200 ft.
About 0.21 inHg per 200 ft.
Source: International Civil Aviation Organization
E-49
Note that the following conditions will prevent you from obtaining accurate readings:
When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact
There are two standard methods of expressing altitude: absolute altitude, which expresses an absolute
height above sea level, and relative altitude, which expresses the difference between the altitudes of two
different places. This watch expresses altitudes as relative altitude.
Height of building 130 m
(relative altitude)
Rooftop at an altitude of
230 m above sea level
(absolute altitude)
Sea Level
How the Altimeter Measures Altitude
The altimeter can measure altitude based on its own preset values (initial default method) or using a
reference altitude specifi ed by you.
E-50
When you measure altitude based on preset values
Data produced by the watch’s barometric pressure sensor is converted to approximate altitude based on
ISA (International Standard Atmosphere) conversion values stored in watch memory.
When you measure altitude using a reference altitude specifi ed by you
After you specify a reference altitude, the watch uses that value to convert
barometric pressure readings to altitude (page E-44).
When mountain climbing, you can specify a reference altitude value in
accordance with a marker along the way or altitude information from a
map. After that, the altitude readings produced by the watch will be more
accurate than they would without a reference altitude value.
Altimeter Precautions
This watch estimates altitude based on air pressure. This means that altitude readings for the same
location may vary if air pressure changes.
Do not rely upon this watch for altitude reading or perform button operations while sky diving, hang
gliding, or paragliding, while riding a gyrocopter, glider, or any other aircraft, or while engaging in any
other activity where there is the chance of sudden altitude changes.
Do not use this watch for measuring altitude in applications that demand professional or industrial level
precision.
Remember that the air inside of a commercial aircraft is pressurized. Because of this, the readings
produced by this watch will not match the altitude readings announced or indicated by the fl ight crew.
400
A
B
400
A
B
E-51
Precautions Concerning Simultaneous Altitude and Temperature Readings
For the more accurate altitude readings, leaving the watch on your wrist is recommended in order to
maintain the watch at a constant temperature.
When taking temperature readings, keep the watch at as stable a temperature as possible. Changes in
temperature can affect temperature readings. See product specifi cations (page E-100) for sensor
accuracy information.
E-52
Taking Direction Readings
You can use the watch to take direction readings to determine a direction (north, south, east, west) or to
nd out your bearing to a destination.
For information about what you can do to ensure direction readings are accurate, see “Magnetic
Declination Correction” (page E-58) and “Digital Compass Precautions” (page E-59).
Correcting Direction Reading Error (2-point Calibration)
Use 2-point calibration to correct for measurement error due to local magnetism or other causes.
Important!
Keep the watch level during the calibration process.
Keep the watch away from electrical household appliances and offi ce equipment, cellphones, and
other sources of strong magnetism during calibration. Such items can make proper calibration
impossible.
To perform 2-point calibration
1. Enter the Digital Compass Mode (page E-27).
2. Hold down
E
for at least two seconds. Release the button when
-1-
appears on the display.
E-53
3. Press
C
.
This starts calibration of point 1. After calibration of point 1 is
complete, TURN 180° appears on the display, followed by -2-.
If ERR appears on the display, press
C
and then perform calibration of point 1 again.
4. Rotate the watch as precisely as possible 180 degrees from point 1.
5. Press
C
.
This starts calibration of point 2. OK appears on the display after calibration is complete. After one
second, the watch will return to the direction reading screen.
If ERR appears on the display, perform the procedure from step 3 again.
E-54
To take a direction reading
Important!
To ensure accuracy, be sure to perform 2-point calibration under actual measurement conditions
before taking direction readings.
1. Enter the Digital Compass Mode (page E-27).
The watch will automatically start taking direction readings. Readings will be taken and the display
will be updated every second for about 60 seconds. At this point you can check the direction (north,
south, east west) reading.
North
East
South
West
E-55
2. During the approximately 60 seconds that the above reading operation is in progress, point 12 o'clock
on the watch in the direction of the bearing you want to read.
About one second later, the direction and bearing to your objective will appear on the display.
If 60 seconds elapse before you can take a bearing reading, press
C
to restart the direction
reading operation.
315°
Objective Bearing Indication
Meaning
N: North
E: East
W: West
S: South
Bearing to Objective:
Northwest
Bearing Angle
to Objective
Note
The north indicated by the watch is magnetic north (page E-59).
If you want to display true north, see “Magnetic Declination Correction” (page E-58).
If only north is indicated on the display (without south, east, or west), it means that bearing
memory contents are displayed. Press
A
to clear bearing memory contents (page E-56).
You can return to the Timekeeping Mode by pressing
D
any time a reading operation is in
progress or stopped.
Operation Guide 3410
E-56
Example: Positioning a map in accordance with actual surroundings (setting a map)
You can align a map with the northerly direction indicated by the watch, and then compare what is shown
on the map with your actual surroundings. This is helpful for checking your current location and the
location of your objective. This process is called “setting a map”.
Saving a Bearing (Bearing Memory)
You can save the bearing to a particular destination in bearing memory and use it to ensure you are
headed in the correct direction.
1. While the direction and bearing to your objective (page E-54) are displayed, press
A
.
This saves the objective information in bearing memory, and displays it as shown below. Now,
any time you are in the Digital Compass Mode, you can check the objective information currently
stored in bearing memory.
Bearing to Objective
Bearing Angle to
Objective
North
2. To return to direction (north, south, east, west) indication, press
A
to delete bearing memory contents.
Example: Advancing to an objective while monitoring your bearing
Even if you lose sight of your objective, you can use a map to store the required bearing in bearing
memory and refer to the memorized information to advance to your objective.
E-57
1. Set the map (page E-56).
2. Place the watch on the map at your current location, and point 12 o’clock at your desired objective on
the map.
3. Press
A
to store the direction to your objective in bearing memory. Now you can advance towards
your objective while observing the stored direction on the watch display.
Important!
As you progress, the direction to your bearing will change, so you need to keep updating the
information in bearing memory.
Using Bearing Records
You can use the procedure in this section to create a bearing record of your current bearing reading, along
with the date and time of the reading. You can later recall a record to view it.
Important!
The watch has memory for storage of up to 40 records of various types. If you perform an operation
that creates a new record while there are already 40 records in memory, the oldest record is deleted
automatically to make room for the new one (page E-70).
1. Take a bearing reading to your objective so it is shown on the display.
2. Without moving the watch, hold down
C
for at least two seconds.
REC and Hold will appear on the display fi rst, and then Hold will disappear. Release
C
after Hold
disappears.
The watch will create a record of the current bearing to your objective along with the date and
time, and then return automatically to the direction reading screen.
3. To view a record, enter the Data Recall Mode (page E-26) and use the
A
and
C
buttons to scroll
(page E-70).
E-58
Magnetic Declination Correction
With magnetic declination correction, you input a magnetic declination angle (difference between
magnetic north and true north), which allows the watch to indicate true north. You can perform this
procedure when the magnetic declination angle is indicated on the map you are using. Note that you can
input the declination angle in whole degree units only, so you may need to round off the value specifi ed
on the map. If your map indicates the declination angle as 7.4°, you should input 7°. In the case of 7.6°
input 8°, for 7.5° you can input 7° or 8°.
To perform magnetic declination correction
1. In the Digital Compass Mode, hold down the watch’s
E
button for at
least two seconds. Release
E
after
-1-
appears.
2. Press
D
.
DEC will appear on the display and then the current magnetic
declination angle setting will fl ash on the display.
3. Use
A
(East) and
C
(West) to change the settings.
The following explains magnetic declination angle direction
settings.
OFF
: No magnetic declination correction performed. The magnetic
declination angle with this setting is 0°.
E
: When magnetic north is to the east (east declination)
W
: When magnetic north is to the west (west declination)
You can select a value within the range of W 90° to E 90° with
these settings.
You can turn off (OFF) magnetic declination correction by pressing
A
and
C
at the same time.
Magnetic declination angle
direction value (E, W, or OFF)
Magnetic declination
angle value
Magnetic declination angle
direction value (E, W, or OFF)
Magnetic declination
angle value
E-59
The illustration, for example, shows the value you should input and the direction setting you should
select when the map shows a magnetic declination of 1° West.
4. When the setting is the way you want, press
E
to exit the setting screen.
Digital Compass Precautions
Magnetic North and True North
The northerly direction can be expressed either as magnetic north or true
north, which are different from each other. Also, it is important to keep in mind
that magnetic north moves over time.
Magnetic north is the north that is indicated by the needle of a compass.
True north, which is the location of the North Pole of the Earth’s axis, is the
north that is normally indicated on maps.
The difference between magnetic north and true north is called the
“declination”. The closer you get to the North Pole, the greater the
declination angle.
Location
Taking a direction reading when you are near a source of strong magnetism can cause large errors in
readings. Because of this, you should avoid taking direction readings while in the vicinity of the
following types of objects: permanent magnets (magnetic necklaces, etc.), concentrations of metal
(metal doors, lockers, etc.), high tension wires, aerial wires, household appliances (TVs, personal
computers, washing machines, freezers, etc.).
Accurate direction readings are impossible while in a train, boat, air plane, etc.
Accurate readings are also impossible indoors, especially inside ferroconcrete structures. This is
because the metal framework of such structures picks up magnetism from appliances, etc.
True north
Earth
Magnetic north
True north
Earth
Magnetic north
E-60
Storage
The precision of the bearing sensor may deteriorate if the watch becomes magnetized. Because of
this, you should store the watch away from magnets or any other sources of strong magnetism,
including: permanent magnets (magnetic necklaces, etc.) and household appliances (TVs, personal
computers, washing machines, freezers, etc.).
Whenever you suspect that the watch may have become magnetized, perform the procedure under “To
perform 2-point calibration” (page E-52).
E-61
Taking Barometric Pressure and Temperature Readings
This watch uses a pressure sensor to measure air pressure (barometric pressure) and a temperature
sensor to measure temperature.
To take barometric pressure and temperature readings
Enter the Barometer/Thermometer Mode (page E-27).
This will automatically start a barometric pressure/temperature reading
operation, and the results will appear on the display in about one
second.
Readings will continue to be taken about every fi ve seconds for the
rst three minutes, and then about every two minutes thereafter.
You can restart the reading operation from the beginning at any time
by pressing
C
.
Note
Press
D
to return to the Timekeeping Mode.
The watch will return to the Timekeeping Mode automatically if you do
not perform any operation for about 1 hour after entering the
Barometer/Thermometer Mode.
Barometric
pressure graph
Barometric
pressure
Pressure
differential
pointer
Temperature
Barometric
pressure graph
Barometric
pressure
Pressure
differential
pointer
Temperature
E-62
Barometric Pressure
Barometric pressure is displayed in units of 1 hPa (or 0.05 inHg).
The displayed barometric pressure value changes to
- - -
if a measured
barometric pressure falls outside the range of 260 hPa to 1,100 hPa (7.65
inHg to 32.45 inHg). The barometric pressure value will reappear as
soon as the measured barometric pressure is within the allowable range.
Temperature
Temperature is displayed in units of 0.1°C (or 0.2°F).
The displayed temperature value changes to
- - -
°C (or °F) if a
measured temperature falls outside the range of –10.0°C to 60.0°C
(14.0°F to 140.0°F). The temperature value will reappear as soon as
the measured temperature is within the allowable range.
Display Units
You can select either hectopascals (hPa) or inchesHg (inHg) as the display unit for the measured
barometric pressure, and Celsius (°C) or Fahrenheit (°F) as the display unit for the measured temperature
value. See “To specify temperature, barometric pressure, and altitude display units” (page E-35).
Barometric Pressure Graph
Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure readings automatically every two
hours. Readings are used to produce barometric pressure graph and
barometric pressure differential pointer readings.
Temperature
Barometric pressure
change indicator
Barometric
pressure
Temperature
Barometric pressure
change indicator
Barometric
pressure
Barometric pressure graphBarometric pressure graph
E-63
Reading the Barometric Pressure Graph
The barometric pressure graph shows a chronological history of pressure readings.
When display of the barometric change indicator is disabled, the graph shows the results of up to 21
barometric pressure readings (42 hours).
When display of the barometric change indicator is enabled, the graph shows the results of up to 11
barometric pressure readings (22 hours).
The horizontal axis of the graph represents time, with each dot standing for
two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each
dot standing for the relative difference between its reading and that of the
dots next to it. Each dot represents 1 hPa.
The following shows how to interpret the data that appears on the barometric pressure graph.
Rising barometric pressure indicates that upcoming weather will improve.
Falling barometric pressure indicates that upcoming weather will deteriorate.
Note
If there are sudden changes in weather or temperature, the graph line of past
reading may run off the top or bottom of the display. The entire graph will become
visible once barometric conditions stabilize.
The following conditions cause the barometric pressure reading to be skipped,
with the corresponding point on the barometric pressure graph being left blank.
– Barometric reading that is out of range (260 hPa to 1,100 hPa or 7.65 inHg to
32.45 inHg)
– Sensor malfunction
Barometric
pressure
Time
Barometric
pressure
Time
Not visible on
the display.
Not visible on
the display.
Operation Guide 3410
E-64
Barometric Pressure Differential Pointer
This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph
(page E-62), and the current barometric pressure value displayed in the
Barometer/Thermometer Mode (page E-61).
Reading Barometric Pressure Differential Pointer
Pressure differential is indicated in the range of
±10 hPa, in 1-hPa units.
The nearby illustration, for example, shows
what the pointer would indicate when the
calculated pressure differential is
approximately – 5 hPa (approximately – 0.15
inHg).
Barometric pressure is calculated and
displayed using hPa as the standard. The
barometric pressure differential also can be
read in inHg units as shown in the illustration
(1 hPa
=
0.03 inHg).
Barometric
pressure
differential
pointer
Barometric
pressure
differential
pointer
−0.15
−5
−10
−0.3
Barometric pressure
differential pointer
inHg values
hPa values
Current pressure
greater than most
recent measured
pressure
Current pressure
less than most
recent measured
pressure
−0.15
−5
−10
−0.3
Barometric pressure
differential pointer
inHg values
hPa values
Current pressure
greater than most
recent measured
pressure
Current pressure
less than most
recent measured
pressure
E-65
Barometric Pressure Change Indications
Your watch analyzes past barometric pressure readings and uses a barometric pressure change indicator
to inform you about changes in pressure.The watch will beep to let you know when a signifi cant change in
barometric pressure is detected. This means you could start taking barometric pressure readings after
reaching a lodge or camp area, and then check the watch the next morning for changes in pressure, and
plan you day’s activities accordingly. Note that you can enable or disable display of the barometric
pressure change indicator as desired.
Reading the Barometric Pressure Change Indicator
Indicator Meaning
Sudden fall in pressure.
Sudden rise in pressure.
Sustained rise in pressure, changing to a fall.
Sustained fall in pressure, changing to a rise.
The barometric pressure change indicator is not displayed if there has been no noteworthy change in
barometric pressure.
E-66
Important!
To ensure proper results, take barometric readings under conditions where the altitude remains
constant.
Example
– In a lodge or campground
– On the ocean
A change in altitude causes a change in barometric pressure. Because of this, correct readings are
impossible. Do not take readings while ascending or descending a mountain, etc.
Enabling or Disabling Display of the Barometric Pressure Change Indicator
You can enable or disable display of the barometric pressure change indicator as desired. When display
of the indicator is enabled, the watch will take a barometric pressure reading every two minutes,
regardless of the mode it is in.
When
BARO
is shown on the display, it means that barometric pressure change indicator display is
enabled.
To enable or disable the barometric pressure change alert
In the Barometer/Thermometer Mode, hold down
A
for at least two seconds. Keep
A
depressed until
the current setting (
INFO Hold ON
or
INFO Hold OFF
) starts to fl ash on the display.
If barometric pressure change indicator display is currently enabled,
BARO
will also appear in the
display.
BARO
will not appear if display is currently disabled.
Note that barometric pressure change indicator display will turn off automatically 24 hours after you
turn it on or battery power goes low.
Note that time calibration signal reception and power saving (page E-14) are disabled while barometric
pressure change indicator display is enabled.
Note that barometric pressure change indicator display cannot be enabled while the watch’s battery is low.
E-67
Using Barometric Pressure and Temperature Records
You can use the procedure in this section to create a barometric pressure and temperature record of your
current readings, along with the date and time of the reading. You can later recall a record to view it.
Important!
The watch has memory for storage of up to 40 records of various types. If you perform an operation
that creates a new record while there are already 40 records in memory, the oldest record is deleted
automatically to make room for the new one (page E-70).
1. While barometric pressure and temperature readings are in progress, hold down
C
for at least two
seconds.
REC and Hold will appear on the display fi rst, and then Hold will disappear. Release
C
after
Hold disappears.
The watch will create a record of the current barometric pressure and temperature, along with
the date and time, and then return automatically to the barometric pressure/temperature reading
screen.
2. To view a record, enter the Data Recall Mode (page E-26) and use the
A
and
C
buttons to scroll. See
“Viewing Memory Records” (page E-70) for more information.
Pressure Sensor and Temperature Sensor Calibration
The pressure sensor and temperature sensor built into the watch are calibrated at the factory and normally
require no further adjustment. If you notice serious errors in the pressure readings and temperature
readings produced by the watch, you can calibrate the sensor to correct the errors.
Important!
Incorrectly calibrating the barometric pressure sensor can result in incorrect readings. Before
performing the calibration procedure, compare the readings produced by the watch with those of
another reliable and accurate barometer.
E-68
Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.
Compare the readings produced by the watch with those of another reliable and accurate thermometer.
– If adjustment is required, remove the watch from your wrist and wait for 20 or 30 minutes to give the
temperature of the watch time to stabilize.
To calibrate the pressure sensor and the temperature sensor
1. Take a reading with another measurement device to determine the
exact current barometric pressure or temperature.
2. In the Barometer/Thermometer Mode, hold down
E
for at least two
seconds. You can release
E
after
TEMP
appears.
The current temperature calibration setting will fl ash in the display
at this time.
3. Press
D
to move the fl ashing between the temperature value and
barometric pressure value, to select the one you want to calibrate.
4. Use
A
(+) and
C
(
) to select the temperature and barometric
pressure value display units as shown below.
Temperature 0.1°C (0.2°F)
Barometric Pressure 1 hPa (0.05 inHg)
To return the currently fl ashing value to its initial factory default
setting, press
A
and
C
at the same time. OFF will appear at
the fl ashing location for about one second, followed by the initial
default value.
5. Press
E
to return to the Barometer/Thermometer Mode screen.
E-69
Barometer and Thermometer Precautions
The pressure sensor built into this watch measures changes in air pressure, which you can then apply
to your own weather predictions. It is not intended for use as a precision instrument in offi cial weather
prediction or reporting applications.
Sudden temperature changes can affect pressure sensor readings. Because of this, there may be
some error in the readings produced by the watch.
Temperature reading are affected by your body temperature, direct sunlight, and moisture. To achieve
a more accurate temperature reading, remove the watch from your wrist, place it in a well ventilated
location out of direct sunlight, and wipe all moisture from the case. It takes approximately 20 to 30
minutes for the case of the watch to reach the surrounding temperature.
E-70
Viewing Memory Records
You can use the Data Recall Mode to recall and view the following type of data in watch memory.
Date/Time Records (page E-30)
Altitude Records (page E-45)
Historical altitude values (page E-46)
Direction Records (page E-56)
Barometric Pressure and Temperature Records (page E-67)
To view data in watch memory
1. Use
D
to select the Data Recall Mode (
REC
) as shown on page E-26.
About one second after REC appears on the display, the display will change to show the fi rst
record of the memory area you were viewing when you last exited the Data Recall Mode.
2. Use
A
and
C
to scroll through the screens for an area and display the one you want.
Records are assigned numbers in the sequence they are recorded. If you create a new record (by
saving data) while there are already 40 records in memory, record number 01 (the oldest record)
will be deleted automatically to make room for the new record.
If you attempt to recall a record while there are no records in memory, a blank record will appear
on the display.
Holding the
A
or
C
button will scroll through the records at high speed.
E-71
Historical
altitude
values (4)
* Segment indicating currently displayed record flashes.
Number of
records *
Records (40
maximum)
Currently
displayed
record
Operation Guide 3410
E-72
Records
Month - Day
Hour,
minute,
second
Temperature
(alternating with
month, day)
Barometric
pressure
(alternating
with hour,
minute)
Hour, minute
(alternating with
month, day)
Bearing
Time (alternates
with date)
Altitude
Time Bearing
Barometer/Thermometer
Altitude
E-73
Historical Altitude Values
Hour, minute
(alternating with
month, day)
High
Altitude
Month, day
(alternating with
year) *
Total
Ascent
Hour, minute
(alternating with
month, day)
Low
Altitude
Month, day
(alternating with
year) *
Total
Descent
High Altitude Low Altitude
Total Ascent
Total Descent
* During display of the cumulative ascent or cumulative descent value, shows the
cumulation start date.
E-74
To delete all saved data
Important!
A delete operation cannot be undone! Make sure you do not need data before you delete it.
In the Data Recall Mode, hold down
E
for at least fi ve seconds.
Hold
will fl ash on the display fi rst for
about two seconds and then disappear. Keep
E
depressed.
Hold
will start fl ashing again and then it will
disappear after about fi ve seconds. Release
E
at this time. - - - - will appear on the display to indicate
that all the data was deleted.
To delete a specifi c record
Important!
A delete operation cannot be undone! Make sure you do not need data before you delete it.
1. In the Data Recall Mode, use
A
and
C
to scroll through records in watch memory until the one you
want to delete is displayed.
2. Hold down
E
for at least two seconds. First,
CLEAR Hold
will fl ash in the display. After that,
Hold
will
disappear. Release
E
when
Hold
disappears.
CAUTION!
Holding down
E
for more than about fi ve seconds will delete all data currently in watch memory.
E-75
Checking the Current Time in a Different Time Zone
You can use the World Time Mode to view the current time in one of 31 time zones (48 cities) around the
globe. The city that is currently selected in the World Time Mode is called the “World Time City”.
To enter the World Time Mode
Use
D
to select the World Time Mode (
WT
) as shown on page E-26.
World Time
City time
8:58
Home City
time
22:58
Time offset graphic
(24-hour indication)
Currently selected
Word Time City
Current timekeeping
Mode time
Current time in the currently
selected World Time City
After about one second, the city code and name of the currently selected city will scroll across the
display. After that, the city code only will remain on the display.
To view the time in another time zone
In the World Time Mode, use
A
(East) and
C
(West) to scroll through city codes.
E-76
To specify standard time or daylight saving time (DST) for a city
1. In the World Time Mode, use
A
(East) and
C
(West) to scroll through
the available city codes.
Keep scrolling until the city code whose Standard Time/Daylight
Saving Time setting you want to change is displayed.
2. Hold down
E
for at least two seconds.
DST
and
Hold
will appear on
the display fi rst, and then
Hold
will disappear. Release
E
after
Hold
disappears.
This will toggle summer time between on and off.
The DST indicator is displayed while summer time is turned on.
Using the World Time Mode to change the DST setting of the
city code that is selected as your Home City also will change the
Timekeeping Mode time DST setting.
Note that you cannot switch between standard time/daylight
saving time (DST) while UTC is selected as the World Time City.
Note that the standard time/daylight saving time (DST) setting
affects only the currently selected city. Other cities are not
affected.
DST indicatorDST indicator
E-77
Using the Stopwatch
The stopwatch measures elapsed time, split times, and two fi nishes.
To enter the Stopwatch Mode
Use
D
to select the Stopwatch Mode (
STW
) as shown on page E-26.
To perform an elapsed time operation
A
A
A A
C
Start Stop (Resume) (Stop) Reset
To pause at a split time
A
C
C A
C
Start Split
(
SPLIT
appears
in the upper part
of the display.)
Split release Stop Reset
Current time
1/10-second
graphic
Hours
Seconds
Minutes
1/100 second
Current time
1/10-second
graphic
Hours
Seconds
Minutes
1/100 second
E-78
To measure two fi nishes
A
C
A C
C
Start Split
First runner fi nishes.
(
SPLIT
appears in
the upper part of the
display.)
Display time of fi rst
runner
Stop
Second runner
nishes.
Split release
Display time of
second runner
Reset
Note
The Stopwatch Mode can indicate elapsed time up to 999 hours, 59 minutes, 59.99 seconds.
Once started, stopwatch timing continues until you press
A
to stop it, even if you exit the Stopwatch
Mode to another mode and even if timing reaches the stopwatch limit defi ned above. A paused timing
operation will remain paused until you press
A
to resume it or
C
to reset.
Exiting the Stopwatch Mode while a split time is frozen on the display clears the split time and returns
to elapsed time measurement.
While
SPLIT
is shown in the display, it alternates with the hour digits of the split time at one-second
intervals.
You can directly access the Stopwatch Mode from the Timekeeping Mode by pressing the
A
button. If
the stopwatch is reset to all zeros when you enter the Stopwatch mode, the watch will beep twice and
an elapsed time operation will start automatically. You can check whether the stopwatch is reset by
looking at the Timekeeping Mode graphic (page E-29).
E-79
Using the Countdown Timer
The countdown timer can be confi gured to start at a preset time, and sound an alarm when the end of the
countdown is reached.
To enter the Countdown Timer Mode
Use
D
to select the Countdown Timer Mode (
TMR
) as shown on page E-26.
To specify the countdown start time
1. Enter the Countdown Timer Mode.
If a countdown is in progress (indicated by the seconds counting
down), press
A
to stop it and then press
C
to reset to the current
countdown start time.
If a countdown is paused, press
C
to reset to the current
countdown start time.
2. Hold down
E
for at least two seconds.
SET Hold will fl ash on the display and then the current start time
setting will start to fl ash. Keep
E
depressed until the start time
setting starts to fl ash.
3. Press
D
to move the fl ashing between the hour and minute settings.
4. Use
A
(+) and
C
(–) to change the fl ashing item.
To set the starting value of the countdown time to 24 hours, set 0H 00’00.
5. Press
E
to exit the setting screen.
Countdown time
(Hour, minutes, seconds)
Minutes
graphic
Current time
Countdown time
(Hour, minutes, seconds)
Minutes
graphic
Current time
Operation Guide 3410
E-80
To perform a countdown timer operation
A
A
A A
C
Start Stop (Restart) (Stop) Reset
Before starting a countdown timer operation, check to make sure that a countdown operation is not in
progress (indicated by the seconds counting down). If it is, press
A
to stop it and then
C
to reset to
the countdown start time.
An alarm sounds for ten seconds when the end of the countdown is reached. This alarm will sound in
all modes. The countdown time is reset to its starting value automatically when the alarm sounds.
To stop the alarm
Press any button.
E-81
Using the Alarm
You can set fi ve independent daily alarms. When an alarm is turned on, an alarm will sound for about 10
seconds each day when the time in the Timekeeping Mode reaches the preset alarm time. This is true even
if the watch is not in the Timekeeping Mode. One of the daily alarms is a snooze alarm. The other four are
one-time alarms. The snooze alarm will sound every fi ve minutes up to seven times or until it is turned off.
You can also turn on an Hourly Time Signal, which will cause the watch to beep twice every hour on the
hour.
To enter the Alarm Mode
Use
D
to select the Alarm Mode (
ALM
) as shown on page E-26.
Alarm name
Alarm time
(Hour : Minutes)
Alarm time
19:00
Current time
Alarm ON/OFF
Current time
22:58
24-hour Display *
* Not indicated when the hourly time
signal screen is displayed.
The alarm name indicates an alarm screen.
SIG
is shown when the Hourly Time Signal screen is on the
display.
When you enter the Alarm Mode, the data you were viewing when you last exited the mode appears
rst.
E-82
To set an alarm time
1. In the Alarm Mode, use
A
to scroll through the alarm screens until the
one whose time you want to set is displayed.
AL-1 AL-2 AL-3
SIG* SNZ AL-4
* There is no time setting for the hourly time signal.
2. Hold down
E
until SET Hold appears on the display and then the current settings start to fl ash.
This is the setting screen.
3. Press
D
to move the fl ashing between the hour and minute settings.
4. While a setting is fl ashing, use
A
(+) and
C
(–) to change it.
When setting the alarm time using the 12-hour format, take care to set the time correctly as a.m. (no
indicator) or p.m. (P indicator).
5. Press
E
to exit the setting screen.
Setting an alarm time causes that alarm to turn on automatically.
E-83
To turn an alarm and the Hourly Time Signal on and off
1. In the Alarm Mode, use
A
to select an alarm or the Hourly Time
Signal.
2. When the alarm or the Hourly Time Signal you want is selected, press
C
to turn it on and off.
The alarm on indicator (when any alarm is on), snooze alarm indicator
(when the snooze alarm is on), and the Hourly Time Signal on indicator
(when the Hourly Time Signal is on) are shown on the display in all
modes.
To stop the alarm
Press any button.
Note
The snooze alarm sounds up to seven times at intervals of about fi ve minutes.
After the snooze alarm fi rst sounds,
SNZ
will fl ash on the display until the snooze alarm sounds all
seven times or until it is canceled.
The snooze alarm will be canceled when any of the following occurs while the
SNZ
indicator is fl ashing
on the display.
- If you turn off the snooze alarm
- If you display the snooze alarm setting screen
- If you display the Timekeeping Mode setting screen
- If your Home City and World Time City are the same city, and you use the World Time Mode to
change the summer time setting of your Home City
Hourly time signal
on indicator
Snooze
alarm
indicator
Alarm on indicator
Hourly time signal
on indicator
Snooze
alarm
indicator
Alarm on indicator
E-84
Looking up Sunrise and Sunset Times
You can use the Sunrise/Sunset Mode to look up the sunrise and sunset times for a particular date (year,
month, day) and location.
To view sunrise and sunset times
Use
D
to select the Sunrise/Sunset Mode (
SUN
) as shown on page E-26.
Current date
Sunrise
4:25
Current time *
22:58
Sunrise time
Sunset time
24-hour Display
Sunset
19:00
* Indicated only when the displayed date
is today’s date.
This will display the sunrise and sunset times for the current date based the currently specifi ed city
code, latitude, and longitude.
Sunrise/sunset times will not be displayed when battery power is low.
Before trying to use the Sunrise/Sunset Mode, you need to confi gure settings for the city code,
longitude, and latitude for the location whose sunrise and sunset times you want to view.
The factory default confi guration of the location is: City Code:
TYO
(Tokyo); Latitude: North 35.7
degrees; Longitude: East 139.7 degrees.
E-85
To view the sunrise/sunset time for a particular date
1. Enter the Sunrise/Sunset Mode.
2. While the sunrise/sunset time are on the display, use
A
(+) and
C
(–)
to scroll through the dates.
Pressing either of the above buttons causes a date (month and
day) to appear on the display.
When you release the button, the sunrise time of the selected day
will be shown in the middle display, while the sunset time will be
shown in the lower display.
You can select any date between January 1, 2000 and December
31, 2099.
Note
If you think that the sunrise and/or sunset times are not correct for
some reason, check the watch’s city code, longitude and latitude
settings.
The sunrise and sunset times displayed by this watch are times at
sea level. Sunrise and sunset times are different at altitudes other
than sea level.
Date
Year
Date
Year
E-86
To look up the sunrise and sunset times for a specifi c location
Important!
If you select a different city code to look up the sunrise and sunset times there, return to the city
code of your Home City (your current location) when you are fi nished. Otherwise, the time shown
in the Timekeeping Mode will not be correct.
For information about the Home City setting, see “Con guring Home City Settings” (page E-31).
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the
display fi rst, and then
Hold
will disappear. Release
E
after
Hold
disappears.
2. Use
A
(East) and
C
(West) to select the city code whose sunrise and sunset times you want to view.
For details about city codes, see the “City Code Table” at the back of this manual.
If this display shows the information you need, you can exit this procedure at this point by pressing
E
twice. If you want to specify a latitude and longitude for a more exact reading, advance to step 3,
below.
E-87
3. Press
E
to display the longitude/latitude setting screen, with the
latitude setting fl ashing.
4. Use
D
to move the fl ashing between the latitude and the longitude
setting.
5. Use
A
(+) and
C
(–) to change the fl ashing setting.
You can configure the longitude and latitude setting within
following ranges.
Latitude Range: 65.0°S (South 65.0 degrees) to 0°N to 65.0°N
(North 65.0 degrees)
Longitude Range: 179.9°W (West 179.9 degrees) to 0°E to 180.0°E
(East 180.0 degrees)
Latitude and longitude values are rounded off to the nearest
degree.
6. Press
E
to return to the Timekeeping Mode.
7. Use
D
to select the Sunrise/Sunset Mode (
SUN
) as shown on page
E-26.
Display the location whose sunrise and sunset times you want to
view.
Latitude
Longitude
Press D.
Latitude
Longitude
Press D.
Operation Guide 3410
E-88
Illumination
The display of the watch is illuminated for easy reading in the dark.
The watch’s auto light switch turns on illumination automatically when
you angle the watch towards your face.
The auto light switch must be turned on (page E-90) for it to operate.
To turn on illumination manually
Press
L
in any mode to illuminate the display.
You can use the procedure below to select either 1.5 seconds or three
seconds as the illumination duration. When you press
L
, the display
will remain illuminated for about 1.5 seconds or three seconds,
depending on the current illumination duration setting.
The above operation turns on illumination regardless of the current
auto light switch setting.
Illumination is disabled during time calibration signal reception, while
confi guring sensor measurement mode settings, and during bearing
sensor calibration.
To change the illumination duration
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the
display fi rst, and then
Hold
will disappear. Release
E
after
Hold
disappears.
2. Use
D
to cycle through the setting screens until
LIGHT
appears in the display.
The current illumination duration setting (1 or 3) will be fl ashing in the middle display.
See the sequence in step 2 of the procedure under “To change the current time and date
settings manually” (page E-33) for information about how to scroll through setting screens.
E-89
3. Press
A
to toggle the illumination duration between three seconds (
3
displayed) and 1.5 seconds (
1
displayed).
4. After all of the settings are the way you want, press
E
twice to exit the setting screen.
About the Auto Light Switch
Turning on the auto light switch causes illumination to turn on,
whenever you position your wrist as described below in any mode.
Moving the watch to a position that is parallel to the ground and
then tilting it towards you more than 40 degrees causes
illumination to turn on.
Warning!
Always make sure you are in a safe place whenever you are reading the display of the watch
using the auto light switch. Be especially careful when running or engaged in any other activity
that can result in accident or injury. Also take care that sudden illumination by the auto light
switch does not startle or distract others around you.
When you are wearing the watch, make sure that its auto light switch is turned off before riding
on a bicycle or operating a motorcycle or any other motor vehicle. Sudden and unintended
operation of the auto light switch can create a distraction, which can result in a traffi c accident
and serious personal injury.
More than
40°
Wear the watch on the
outside of your wrist
More than
40°
Wear the watch on the
outside of your wrist
E-90
Note
This watch features a “Full Auto Light”, so the auto light switch operates only when available light is
below a certain level. It does not illuminate the display under bright light.
The auto light switch is always disabled, regardless of its on/off setting, when any one of the following
conditions exists.
While an alarm is sounding
While a bearing sensor calibration operation is being performed in the Digital Compass Mode
While a receive operation is in progress in the Receive Mode
While a sunrise or sunset time is being calculated
While in a sensor mode, an auto light switch operation is performed after a sensor reading
To turn the auto light switch on and off
In the Timekeeping Mode, hold down
L
for at least three seconds to
toggle the auto light switch on (
LT
displayed) and off (
LT
not displayed).
The auto light switch turns off automatically whenever battery power
drops to Level 4 (page E-11).
Auto light switch on
indicator
Auto light switch on
indicator
E-91
Illumination Precautions
The LED that provides illumination loses power after very long use.
Illumination may be hard to see when viewed under direct sunlight.
Illumination turns off automatically whenever an alarm sounds.
Frequent use of illumination runs down the battery.
Auto light switch precautions
Wearing the watch on the inside of your wrist, movement of your arm, or vibration of your arm can
cause frequent activation of the auto light switch and illumination of the display. To avoid running down
the battery, turn off the auto light switch whenever engaging in activities that might cause frequent
illumination of the display.
Note that wearing the watch under your sleeve while the auto light switch is turned on can cause
frequent illumination of the display and can run down the battery.
Illumination may not turn on if the face of the watch is more than 15 degrees above
or below parallel. Make sure that the back of your hand is parallel to the ground.
Illumination turns off after the preset illumination duration (page E-88), even if you
keep the watch pointed towards your face.
Static electricity or magnetic force can interfere with proper operation of the auto
light switch. If illumination does not turn on, try moving the watch back to the
starting position (parallel with the ground) and then tilt it back towards your face
again. If this does not work, drop your arm all the way down so it hangs at your
side, and then bring it back up again.
You may notice a very faint clicking sound coming from the watch when it is shaken
back and forth. This sound is caused by mechanical operation of the auto light
switch, and does not indicate a problem with the watch.
E-92
Other Settings
Button Operation Tone
The button operation tone sounds any time you press one of the watch’s buttons. You can turn the button
operation tone on or off as desired.
Even if you turn off the button operation tone, the alarm, Hourly Time Signal, barometric pressure
change alert, and Countdown Timer Mode alarm all operate normally.
To turn the button operation tone on and off
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the display fi rst, and then
Hold
will disappear.
Release
E
after
Hold
disappears.
2. Use
D
to cycle through settings on the display until the current button
operation tone (
MUTE
or
KEY
) is displayed.
See the sequence in step 2 of the procedure under “To change the
current time and date settings manually” (page E-33) for
information about how to scroll through setting screens.
3.
Press
A
to toggle the button operation tone on (
KEY
) and off (
MUTE
).
4. After all of the settings are the way you want, press
E
twice to exit the
setting screen.
Note
The mute indicator is displayed in all modes when the button
operation tone is turned off.
Mute indicatorMute indicator
E-93
Power Saving
For details about Power Saving, see page E-14.
To turn Power Saving on or off
1. In the Timekeeping Mode, hold down
E
for at least two seconds.
SET
and
Hold
will appear on the display fi rst, and then
Hold
will disappear.
Release
E
after
Hold
disappears.
2. Use
D
to cycle through the setting screens until the current power
saving setting (
On
or
OFF
) is displayed.
POWER SAVING will scroll across the upper display at this time.
See the sequence in step 2 of the procedure under “To change
the current time and date settings manually” (page E-33) for
information about how to scroll through setting screens.
3. Press
A
to toggle Power Saving on (
On
) and off (
OFF
).
4. After all of the settings are the way you want, press
E
twice to exit the
setting screen.
Note
The Power Saving on indicator (PS) is on the display in all modes
while Power Saving is turned on.
Power saving
on indicator
Power saving
on indicator
E-94
Troubleshooting
Time Setting
See “Radio Controlled Atomic Timekeeping” (page E-15) for information about adjusting the time setting
according to a time calibration signal.
The current time setting is off by hours.
Your Home City setting may be wrong (page E-31). Check your Home City setting and correct it, if
necessary.
The current time setting is off by one hour.
If you are using the watch in an area where time calibration signal reception is possible, see “To confi gure
Home City and summer time settings” (page E-31).
If you are using in the watch in an area where time calibration signal reception is not possible, you may
need to change your Home City’s standard time/daylight saving time (DST) setting manually. Use the
procedure under “To change the current time and date settings manually” (page E-33) to change the
standard time/daylight saving time (DST) setting.
Sensor modes
I can’t change the temperature, barometric pressure, and altitude display units.
When
TYO
(Tokyo) is selected as the Home City, the altitude unit is set automatically to meters (m), the
barometric pressure unit to hectopascals (hPa), and the temperature unit to Celsius (°C). These settings
cannot be changed.
E-95
“ERR” appears on the display while I am using a sensor.
Subjecting the watch to strong impact can cause sensor malfunction or improper contact of internal
circuitry. When this happens,
ERR
(error) will appear on the display and sensor operations will be disabled.
Digital
Compass
Reading
Barometric
Pressure/Temperature
Reading
Altitude
Reading
If
ERR
appears while a reading operation is being performed in a sensor mode, restart the operation. If
ERR
appears on the display again, it can mean there is something wrong with the sensor.
If
ERR
keeps appearing during a reading operation, it could mean there is a problem with the
applicable sensor.
Operation Guide 3410
E-96
Correct altitude readings are not possible.
Relative altitude is calculated based on changes in barometric pressure readings by the pressure sensor.
To minimize the chance of reading error due to changes in barometric pressure, you should update the
reference altitude value before setting off on a trek or any other activity where you plan to take altitude
readings. For more information, see “To specify a reference altitude value” (page E-44).
ERR appears on the display after I perform 2-point calibration.
If
- - -
appears and then changes to
ERR
(error) on the calibration screen, it means that there is something
wrong with the sensor.
If
ERR
disappears after about one second, try performing the calibration again.
If
ERR
keeps appearing, contact your original dealer or nearest authorized CASIO distributor to have
the watch checked.
Whenever you have a sensor malfunction, take the watch to your original dealer or nearest authorized
CASIO distributor as soon as possible.
What causes incorrect direction readings?
Incorrect 2-point calibration. Perform 2-point calibration (page E-52).
Nearby source of strong magnetism, such as a household appliance, a large steel bridge, a steel
beam, overhead wires, etc., or an attempt to take direction readings on a train, boat, etc. Move away
from large metal objects and try again. Note that digital compass operation cannot be performed inside
a train, boat, etc.
E-97
What causes different direction readings to produce different results at the same location?
Magnetism generated by nearby high-tension wires is interfering with detection of terrestrial magnetism.
Move away from the high-tension wires and try again.
Why am I having problems taking direction readings indoors?
A TV, personal computer, speakers, or some other object is interfering with terrestrial magnetism
readings. Move away from the object causing the interference or take the direction reading outdoors.
Indoor direction readings are particularly diffi cult inside ferro-concrete structures. Remember that you will
not be able to take direction readings inside of trains, airplanes, etc.
The barometric pressure differential pointer does not appear on the display when I enter the
Barometer/Thermometer Mode.
This could indicate sensor error. Try pressing
B
again.
The barometric pressure differential pointer is not displayed when the displayed current barometric
value is outside of the allowable measurement range (260 to 1,100 hPa).
World Time Mode
The time for my World Time City is off in the World Time Mode.
This could be due to incorrect switching between standard time and daylight saving time. See “To specify
standard time or daylight saving time (DST) for a city” (page E-76) for more information.
Charging
The watch does not resume operation after I expose it to light.
This can happen after the power level drops to Level 5 (page E-11). Continue exposing the watch to light
until the battery power indicator shows H or M.
E-98
Time Calibration Signal
The information in this section applies only when
LIS
,
LON
,
MAD
,
PAR
,
ROM
,
BER
,
STO
,
ATH
,
MOW
,
HKG
,
BJS
,
HNL
,
ANC
,
YVR
,
LAX
,
YEA
,
DEN
,
MEX
,
CHI
,
NYC
,
YHZ
,
YYT
,
TPE
,
SEL
, or
TYO
is selected
as the Home City. You need to adjust the current time manually when any other city is selected as the
Home City.
The display shows the ERR indicator when I check the result of the latest receive operation.
Possible Cause Remedy Page
You are wearing or moving the
watch, or performing a button
operation during the signal
receive operation.
The watch is in an area with
poor reception conditions.
Keep the watch in an area where reception conditions are good
while the signal receive operation is performed.
E-17
You are in an area where signal
reception is not possible for
some reason.
See “Approximate Reception Ranges”. E-16
The calibration signal is not
being transmitted for some
reason.
Check the website of the organization that maintains the time
calibration signal in your area for information about its down times.
Try again later.
The current time setting changes after I set it manually.
You may have the watch confi gured for auto receive of the time calibration signal (page E-18), which will
cause the time to be adjusted automatically according to your currently selected Home City. If this results
in the wrong time setting, check your Home City setting and correct it, if necessary (page E-31).
E-99
The current time setting is off by one hour.
Possible Cause Remedy Page
Signal reception on a day for
switching between standard
time/daylight saving time (DST)
may have failed for some reason.
Perform the operation under “To get ready for a receive operation”.
The time setting will be adjusted automatically as soon as signal
reception is successful.
E-17
If you are unable to receive the time calibration signal, change the
standard time/daylight saving time (DST) setting manually.
E-33
Auto receive is not performed or you cannot perform manual receive.
Possible Cause Remedy Page
The watch is not in the
Timekeeping Mode or World
Time Mode.
Auto receive is performed only while the watch is in the Timekeeping
Mode or World Time Mode. Switch to either of these two modes.
E-26
Your Home City setting is wrong. Check your Home City setting and correct it, if necessary. E-31
There is not enough power for
signal reception.
Expose the watch to light to charge it. E-10
Signal reception is being performed successfully, but the time and/or day is wrong.
Possible Cause Remedy Page
Your Home City setting is wrong. Check your Home City setting and correct it, if necessary. E-31
The DST setting may be
incorrect.
Change the DST setting to Auto DST. E-31
E-100
Specifi cations
Accuracy at normal temperature:
±15 seconds a month (with no signal calibration)
Timekeeping:
Hour, minutes, seconds, p.m. (P), year, month, day, day of the week
Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Date/Time Records: Up to 40 records (shared storage with altitude, bearing, and barometric pressure/
temperature records)
Other: Two display formats (day of the week screen, barometric pressure graph screen); Home City
code (can be assigned one of 48 city codes); Standard Time / Daylight Saving Time (summer time)
Year display on setting screen only.
Time Calibration Signal Reception:
Auto receive 6 times a day (5 times a day for the Chinese calibration
signal) ; Remaining auto receives cancelled as soon as one is successful; Manual receive;
Receive Mode
Receivable Time Calibration Signals: Mainfl ingen, Germany (Call Sign: DCF77, Frequency: 77.5
kHz); Anthorn, England (Call Sign: MSF, Frequency: 60.0 kHz); Fort Collins, Colorado, the
United States (Call Sign: WWVB, Frequency: 60.0 kHz); Fukushima, Japan (Call Sign: JJY,
Frequency: 40.0 kHz); Fukuoka/Saga, Japan (Call Sign: JJY, Frequency: 60.0 kHz) ; Shangqiu
City, Henan Province, China (Call Sign: BPC, Frequency: 68.5 kHz)
Altimeter:
Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference altitude
Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference altitude or due to
atmospheric conditions.
Display unit: 1 m (or 5 ft.)
E-101
Current Altitude Data: Every second for the fi rst 3 minutes, followed by every 5 seconds for
approximately 1 hour (
0’05
); every second for the fi rst 3 minutes, followed by every 2 minutes for
approximately 12 hours (
2’00
)
Altitude Records:
Up to 40 records (shared storage with date/time, bearing, and barometric pressure/temperature
records)
Historical Altitude Values: 1 record of high altitude, low altitude, cumulative ascent, cumulative
descent
Other: Reference altitude setting; Altitude differential; Altitude auto reading interval (
0’05
or
2’00
) ;
Altitude Differential Graph
Digital Compass:
60 seconds continuous reading; 16 directions; Angle value 0° to 359°; Four direction
pointers; Calibration (2-point); Magnetic declination correction; Bearing Memory; Bearing Records:
Up to 40 records (shared storage with date/time, altitude, and barometric pressure/temperature
records)
Barometer:
Measurement and display range:
260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Display unit: 1 hPa (or 0.05 inHg)
Reading timing: Daily from midnight, at two hour intervals (12 times per day); Every fi ve seconds in
the Barometer/Thermometer Mode
Barometric Pressure/Temperature Records: Up to 40 records (shared storage with date/time, altitude,
and bearing records)
Other: Calibration; Manual reading (button operation); Barometric pressure graph; Barometric
pressure differential pointer; Barometric pressure change indicator
E-102
Thermometer:
Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Reading timing: Every fi ve seconds in the Barometer/Thermometer Mode
Other: Calibration; Manual reading (button operation)
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)
Bearing Sensor Precision:
Direction: Within ±10°
Values are guaranteed for a temperature range of –10°C to 60°C (14°F to 140°F).
North pointer: Within ±2 digital segments
Pressure Sensor Precision:
Measurement accuracy: Within ±3hPa (0.1 inHg) (Altimeter accuracy: Within ± 75m (246 ft.))
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
Precision is lessened by strong impact to either the watch or the sensor, and by temperature
extremes.
World Time:
48 cities (31 time zones)
Other: Daylight Saving Time/Standard Time
Stopwatch:
Measuring unit: 1/100 second
Measuring capacity: 999:59' 59.99"
Measuring accuracy: ±0.0006%
Measuring modes: Elapsed time, split time, two fi nishes
E-103
Countdown Timer:
Measuring unit: 1 second
Countdown range: 24 hours
Setting unit: 1 minute
Alarms:
5 Daily alarms (four one-time alarms; one snooze alarm); Hourly time signal
Sunrise/sunset:
Sunrise/sunset time display; selectable date
Illumination:
LED light; Selectable illumination duration (approximately 1.5 seconds or 3 seconds); Auto
Light Switch (Full Auto Light operates only in the dark)
Other:
Battery power indicator; Power Saving; Low-temperature resistance (–10°C/14°F); Button
operation tone on/off
Power Supply:
Solar panel and one rechargeable battery
Approximate battery operating time: 8 months (from full charge to Level 4) under the following
conditions:
Light: 1.5 seconds/day
Beeper: 10 seconds/day
Direction readings: 20 times/month
Climbs: Once (approximately 1 hour of altitude readings)/month
Barometric pressure change indicator readings: Approximately 24 hours/month
Barometric pressure graph: Readings every 2 hours
Time calibration signal receive: 4 minutes/day
Display: 18 hours/day
Frequent use of illumination runs down the battery. Particular care is required when using the auto
light switch (page E-91).
Operation Guide 3410
City Code Table
City
Code
City
UTC Offset/
GMT Differential
PPG Pago Pago –11
HNL Honolulu –10
ANC Anchorage –9
YVR Vancouver
–8
LAX Los Angeles
YEA Edmonton
–7
DEN Denver
MEX Mexico City
–6
CHI Chicago
NYC New York –5
SCL Santiago
–4
YHZ Halifax
YYT St. Johns –3.5
RIO Rio De Janeiro –3
FEN
Fernando de
Noronha
–2
RAI Praia –1
City
Code
City
UTC Offset/
GMT Differential
UTC
0LIS Lisbon
LON London
MAD Madrid
+1
PAR Paris
ROM Rome
BER Berlin
STO Stockholm
ATH Athens
+2CAI Cairo
JRS Jerusalem
MOW Moscow
+3
JED Jeddah
THR Tehran +3.5
DXB Dubai +4
KBL Kabul +4.5
KHI Karachi +5
L
L-1
City
Code
City
UTC Offset/
GMT Differential
DEL Delhi +5.5
KTM Kathmandu +5.75
DAC Dhaka +6
RGN Yangon +6.5
BKK Bangkok +7
SIN Singapore
+8
HKG Hong Kong
BJS Beijing
TPE Taipei
SEL Seoul
+9
TYO Tokyo
ADL Adelaide +9.5
GUM Guam
+10
SYD Sydney
NOU Noumea +11
WLG Wellington +12
* As of December 2012, the offi cial UTC offset
for Moscow, Russia (MOW) was changed from
+3 to +4, but this watch still uses an offset of
+3 (the old offset) for MOW. Because of this,
you should leave the summer time setting
turned on (which advances the time by one
hour) for the MOW time.
The rules governing global times (GMT
differential and UTC offset) and summer time
are determined by each individual country.
Operation Guide 3410
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

G-Shock H-1 Owner's manual

Category
Water pumps
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI