M-system R3-CZ4 is a Zero-Phase Current Input Module with a noise filter. It has four input channels and comes with an installation base (R3-BSx). The R3-CZ4 has various features and configurable parameters, making it a great option for different use cases.

With the PC configurator software (R3CON), you can set parameters like 0% and 100% scaling values, adjustment values (bias and gain), input and output values, and disable unused channels.

The R3-CZ4 has a bi-color RUN indicator LED (red/green) that displays the operating status of the bus (red for bus A, green for bus B, and amber for both buses operating normally). It also has a bi-color ERR indicator LED (red/green) that shows input abnormality (red) and normal operating conditions (green).

M-system R3-CZ4 is a Zero-Phase Current Input Module with a noise filter. It has four input channels and comes with an installation base (R3-BSx). The R3-CZ4 has various features and configurable parameters, making it a great option for different use cases.

With the PC configurator software (R3CON), you can set parameters like 0% and 100% scaling values, adjustment values (bias and gain), input and output values, and disable unused channels.

The R3-CZ4 has a bi-color RUN indicator LED (red/green) that displays the operating status of the bus (red for bus A, green for bus B, and amber for both buses operating normally). It also has a bi-color ERR indicator LED (red/green) that shows input abnormality (red) and normal operating conditions (green).

R3-CZ4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone:
+
81
(
6
)
6659-8201 Fax:
+
81
(
6
)
6659-8510 E-mail: info@m-system.co.jp
EM-8447 Rev.2 P. 1 / 3
ZERO-PHASE CURRENT INPUT MODULE
(with noise lter)
MODEL
R3-CZ4
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
the contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
PACKAGE INCLUDES:
CT input module .............................................................(1)
MODEL NO.
Confirm Model No. marking on the side of the product to be
exactly what you ordered.
INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
HOT INSERTION/REMOVAL OF MODULES
•Removing or replacing modules does not affect other mod-
ules on the same backplane. It is possible to replace them
without removing the power supply. However, replacing
multiple modules at once may greatly change line voltage
levels. We recommend that you replace them one by one.
ENVIRONMENT
•Indoor use
•When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
AND ....
•The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3-CZ4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone:
+
81
(
6
)
6659-8201 Fax:
+
81
(
6
)
6659-8510 E-mail: info@m-system.co.jp
EM-8447 Rev.2 P. 2 / 3
COMPONENT IDENTIFICATION
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
1
2
3
4
5
6
7
8
9
10
FRONT VIEW
SIDE VIEW
ERR LED
RUN LED
Conv.
Rate
Input 2 (SW1)
or
Input 4 (SW2)
Range
Input 1 (SW1)
or
Input 3 (SW2)
Functions
STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the input abnormality;
Green in normal operating conditions.
SIDE DIP SW
• Input Range: SW1, SW2
INPUT 1 (SW 1) INPUT 2 (SW 1)
RANGEINPUT 3 (SW 2) INPUT 4 (SW 2)
1 2 3 4 5 6 7 8
OFF OFF OFF OFF OFF OFF OFF OFF
0 – 1.5mA (*)
ON
OFF OFF OFF
ON
OFF OFF OFF
0 – 0.1mA
• Conversion Rate: SW3
SW
CONVERSION RATE
80 ms (*)
40 ms 20 ms 10 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
(*) Factory setting
Note: Be sure to set unused SW3-3 and 3-4 to OFF.
PC CONFIGURATOR
The following parameters can be set with using PC Configurator Software (model: R3CON):
•0% scaling value
•100% scaling value
•0% adjustment value (bias)
•100% adjustment value (gain)
•0% input value
•100% input value
•Disable the unused channel
R3-CZ4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone:
+
81
(
6
)
6659-8201 Fax:
+
81
(
6
)
6659-8510 E-mail: info@m-system.co.jp
EM-8447 Rev.2 P. 3 / 3
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
DIMENSIONS mm (inch)
130 (5.12)
27.5 (1.08)
109 (4.29)
7.9 (.31)
POSITIONING
GUIDE
TERMINAL
COVER
10–M3.5
SCREW
1
2
3
4
5
6
7
8
9
10
CONNECTION DIAGRAM
BUS CONNECTOR
INTERNAL POWER
INTERNAL
BUS A
INTERNAL
BUS B*
*For dual redundant communication.
INPUT 1
3
4
LOAD
SOURCE
k
l
ZCT
INPUT 2
5
6
LOAD
SOURCE
k
l
ZCT
INPUT 3
7
8
LOAD
SOURCE
k
l
ZCT
INPUT 4
9
10
LOAD
SOURCE
k
l
ZCT
WIRING INSTRUCTIONS
SCREW TERMINAL
Torque: 0.5 N·m
SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.75 mm
2
3.2 (.13) dia.
4 min.
(.16)
12 (.47) max.
6 max.
(.24)
3 (.12) max.
  • Page 1 1
  • Page 2 2
  • Page 3 3

M-system R3-CZ4 User manual

Type
User manual

M-system R3-CZ4 is a Zero-Phase Current Input Module with a noise filter. It has four input channels and comes with an installation base (R3-BSx). The R3-CZ4 has various features and configurable parameters, making it a great option for different use cases.

With the PC configurator software (R3CON), you can set parameters like 0% and 100% scaling values, adjustment values (bias and gain), input and output values, and disable unused channels.

The R3-CZ4 has a bi-color RUN indicator LED (red/green) that displays the operating status of the bus (red for bus A, green for bus B, and amber for both buses operating normally). It also has a bi-color ERR indicator LED (red/green) that shows input abnormality (red) and normal operating conditions (green).

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI