ADTRAN NetVanta Serial Dial Backup Interface Module User manual

Type
User manual

This manual is also suitable for

ADTRAN NetVanta Serial Dial Backup Interface Module (DIM)

The ADTRAN NetVanta Serial Dial Backup Interface Module (DIM) is a device that allows you to connect your NetVanta base unit to an external modem for dial-backup purposes. This means that if your primary WAN connection fails, the DIM can automatically dial out to your modem and establish a backup connection to the Internet or another network.

The DIM supports a variety of features, including:

  • 5-pin RS-232 interface via host RJ-45 DBU connector
  • Modem flow control support via CTS
  • Communication with external modem via AT commands

ADTRAN NetVanta Serial Dial Backup Interface Module (DIM)

The ADTRAN NetVanta Serial Dial Backup Interface Module (DIM) is a device that allows you to connect your NetVanta base unit to an external modem for dial-backup purposes. This means that if your primary WAN connection fails, the DIM can automatically dial out to your modem and establish a backup connection to the Internet or another network.

The DIM supports a variety of features, including:

  • 5-pin RS-232 interface via host RJ-45 DBU connector
  • Modem flow control support via CTS
  • Communication with external modem via AT commands
NetVanta Serial Dial Backup Interface Module (DIM) P/N 1200886L1
For more detailed documentation, visit us online at www.adtran.com.
Quick Start Guide
®
Quick Start Guide, 61200886L1-13B, July 2006 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2006 ADTRAN, All Rights Reserved
SPECIFICATIONS
Features 5-pin RS-232 interface via host RJ-45 DBU connector
Modem flow control support via CTS
Communication with external modem via AT commands
Compliance FCC Part 15 Class A, EN 55022 Class A, EN 55024
EN 61000-3-2, EN 61000-3-3
IEC 60950, EN 60950, UL/CUL 60950, AS/NZS 60950
Physical Dimensions: 2.3-inch W x 2.75-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
An RJ-45 to DB-9 adapter cable (P/N 1200887L1) is
required to connect to the external modem.
NetVanta modules should be installed only in
NetVanta Series products.
CONSOLE
LAN
SLOT 1 NET/D BU
WAN-DDS DBU
WAN-T1 DSX-1 DBU
SERIAL DBU CONNECTION PINOUTS
INSTALLATION INSTRUCTIONS
1. Remove power from the base unit.
2. If the Network Interface Module (NIM) is already in the NetVanta
chassis, release the pins at both edges of the NIM faceplate and slide
the module out of the chassis.
3. Carefully align the P1 connector on the NIM with the J1 connector on
the Serial DIM. Using only fingertip pressure so that neither circuit
board bends or flexes, ensure that the connectors are firmly seated.
Secure the Serial DIM to the NIM using the screws and standoff posts
supplied.
4. Slide the NIM with the Serial DIM attached into the NetVanta option
slot until the NIM is firmly seated against the chassis.
5. Secure the pins at both edges of the NIM.
6. Connect the cables to the associated device(s)
7. Complete installation of the base unit.
For NetVanta modules with outside plant
connections, ensure that all cables are
removed from the module before installing or
removing it from the NetVanta chassis.
Pin Name
1, 2 Unused
3CTS
4TXD
5RXD
6GND
7 DCD
8 Unused
Important: For additional details on product
features, specifications, installation, and safety, refer
to the appropriate Hardware Installation Guide on
the ADTRAN OS System Documentation CD
shipped with the base unit and available online at
www.adtran.com.
NetVanta Serial Dial Backup Interface Module (DIM) P/N 1200886L1
For more detailed documentation, visit us online at www.adtran.com.
Quick Start Guide
®
Quick Start Guide, 61200886L1-13B, July 2006 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2006 ADTRAN, All Rights Reserved
SERIAL DIM COMMANDS
alias <“text”>
Populates the ifAlias OID (Interface Table MIB of RFC2863) for all physical
and virtual interfaces when using SNMP management station.
caller-id override [always <number> | if-no-CID <number>]
Configures the unit to replace caller ID information with a user-specified
number. Use the no form of this command to disable any caller ID overrides.
always <number> Always forces replacement of the incoming
caller ID number with the number given.
if-no-CID <number> Replaces the incoming caller ID number with
the number given only if there is no caller ID
information available for the incoming call.
description <text>
Identifies the specified interface, both physical and virtual (for example,
circuit ID, contact information, etc.), using up to 80 alphanumeric characters.
dialin
Enables the modem for remote console dial-in, disabling the use of the
modem for dial-backup.
init-string <string>
Specifies an initialization string using standard AT commands. Use the no
form of this command to return to the default initialization string.
<string> Specifies an initialization string using standard
AT commands. This string must start with AT
and cannot contain spaces. The default string
is ate0q0v1x4\n0.
shutdown
Disables the interface (both physical and virtual) so that no data will be
passed through. Use the no version of this command to turn on the interface
and allow it to pass data.
  • Page 1 1
  • Page 2 2

ADTRAN NetVanta Serial Dial Backup Interface Module User manual

Type
User manual
This manual is also suitable for

ADTRAN NetVanta Serial Dial Backup Interface Module (DIM)

The ADTRAN NetVanta Serial Dial Backup Interface Module (DIM) is a device that allows you to connect your NetVanta base unit to an external modem for dial-backup purposes. This means that if your primary WAN connection fails, the DIM can automatically dial out to your modem and establish a backup connection to the Internet or another network.

The DIM supports a variety of features, including:

  • 5-pin RS-232 interface via host RJ-45 DBU connector
  • Modem flow control support via CTS
  • Communication with external modem via AT commands

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI