HILLS RELIANCE Jack Fuse PP8FR Power Port User manual

Category
Security device components
Type
User manual

HILLS RELIANCE Jack Fuse PP8FR Power Port is a fused power distribution module for access control with integral fire trip relay. PP8FR has eight individually fused power outputs with a maximum current of 2.5A per output, and a maximum fire power current of 8A. It provides a failsafe method of fire trip interface with two configurable options for connection to the Fire Indication Panel (FIP): either an N/C (Normally Closed) voltage-free contact or a DC voltage. The on-board fire relay is configurable for 12VDC or 24VDC fire trip input.

HILLS RELIANCE Jack Fuse PP8FR Power Port is a fused power distribution module for access control with integral fire trip relay. PP8FR has eight individually fused power outputs with a maximum current of 2.5A per output, and a maximum fire power current of 8A. It provides a failsafe method of fire trip interface with two configurable options for connection to the Fire Indication Panel (FIP): either an N/C (Normally Closed) voltage-free contact or a DC voltage. The on-board fire relay is configurable for 12VDC or 24VDC fire trip input.

1
© Copyright 2011 – Jack Fuse PP8FR Installation Notes
JDC
F1
J1
F2J2
F3
J3
F4J4
F5J5
F6
J6
F7
J7
F8J8
KF
P1
P2
P3
JR
F9 SPARE
F10 SPARE
REFER TO DATA
BEFORE USE
DF
V In
Aux Out
BAA
JF
P
PR
S
Fire Relay
Power Port 8FR V4
PWR
P4
Power Port 8FR – V4 Installation Notes
Fused power distribution module for access control with integral fire trip relay.
1) Mounting
2) Termination
3) Jumper Settings
4) Fire Relay Options
4.1) Fire Trip Interface
4.2) Relay Selection
4.3) Alarm Contacts/Fire Trip Monitoring
5) Expansion Options
5.1) Additional Outputs
5.2) Additional Modules
5.3) Other Fire Equipment
6) Fuse Selection and Replacement
7) Technical Data and Ratings
Before powering the PP8FR you must take the time to read and understand all installation notes.
1) Mounting
The PP8FR is fitted with two DIN rail mounting clips that suit most popular top hat and G profile rails. For low profile enclosures the
PP8FR V4 is also suitable for the popular “Snap Track” mounting method. (TE Connectivity part number 4TK2)
2) Termination
The most common termination method is illustrated below; other options are outlined elsewhere in these notes.
The maximum diameter of cable for each terminal is outlined in section seven Technical Data. Fire trip interface relay and alarm
setup is outlined in section four Fire Relay Options. For Expansion Options see section five.
F1J1
F2J2
F3J3
F4J4
F5J5
F6
J6
F7J7
F8
J8
KF
P1
P2
P3
JR
F9 SPARE
F10 SPARE
REFER TO DATA
BEFORE USE
DF
V In
Aux Out
BAA
JF
P
PR
S
JDC
Fire Relay
Power Port 8FR
DC
Power
Supply
N/C
FIP
Contact
Fire Trip
Alarm
Ouput
Controller/Field
Equipment Power
Expansion Options
Image n
ot to scale
2
© Copyright 2011 – Jack Fuse PP8FR Installation Notes
3) Jumper Settings
Warning: It is important to correctly set and check JF and JDC before applying fire trip or power to the PP8FR module. Incorrect
jumper settings may cause damage to the module and other equipment.
Jumper/Link
Position
Description
J1
-
J8
Associated output connected to
standard
supply power
Associated output connected to supply power via fire relay
Off
No power available to associated output
JR
C
Terminal A
A provides N/C fire relay contact
R
Terminal A
A provides fire relay status monitoring
via
EOL resistors
JF
A (X 2)
Fire trip interface N/C contact in fire panel
B
Fire trip interface DC voltage from fire panel
Off
No power available to associated output
JDC
12V
12VDC Fire trip input
(or 12V supply input for N/C trips)
24V
24VDC Fire trip input (or 24V supply input for N/C trips)
4) Fire Relay Options
4.1) Fire Trip Interface
The on board fire relay is designed to provide a failsafe method of fire trip interface. There are two options for connection to the
FIP. (Fire Indication Panel) Either an N/C (Normally Closed) voltage free contact can be used or the FIP or other device can supply a
DC voltage. Both options are terminated directly to the FT+ and FT- terminals and links set to match (see section 3). Correct polarity
must be observed when using a DC voltage. Examples below.
If an N/C fire trip is used care must be taken to set JDC to the value of the power supply input as this will be used to activate the fire
relay.
4.2) Relay Selection
Relay selection for the PP8FR V4 is greatly simplified compared to previous versions. A 12VDC relay is supplied and on board settings
allows a 12 or 24VDC fire trip to be used. (See section 3 and 4.1)
A simple plug in relay is used and can be replaced easily. A 12VDC relay with minimum 8A rated contacts is recommended.
Relay pin layout viewed from below.
The relay socket accepts a plug in industrial power relay with a 5mm contact pin pitch. There are many suitable relays including but
not limited to: Finder 40/44 series, Song Chuan 845 series and Tyco/Schrack RTE Series
4.3) Alarm Contacts/Fire Trip Monitoring
P1
BAA
JF
JDC
24V
From FIP
Links JF - A (X2) - OFF
B - ON
Link JDC - 24V
12V
24V
5V
PS
P1
BAA
JF
12VDC
From FIP
Links JF - A (X2) - OFF
B - ON
Link JDC - 12V
24V
PS
JDC
12V
24V
P1
BAA
JF
N/C
FIP
Contact
Links JF - A (X2) - ON
B - OFF
Link JDC - 12V
JDC
12V
24V
12V
PS
20mm
5mm 5mm
3
© Copyright 2011 – Jack Fuse PP8FR Installation Notes
The terminals marked A - A are interfaced to the secondary contact of the fire relay. By setting JR to on, the terminals A – A provide
an N/C contact for expansion or alarm monitoring (Maximum 2A)
By removing JR and installing EOL (End Of Line) resistors into the sockets marked PR, the terminals A – A provide a direct interface to
a security panel input without the need to join or solder resistors. Resistor leads should be bent and trimmed to 6-8mm below
resistor base. EOL resistors should be inserted before the fire relay is installed. See examples in diagram below. (P = Parallel EOL
resistor, S = Series EOL resistor)
Different EOL Resistors Same EOL Resistors Single EOL Resistor
5) Expansion Options
Examples of several expansion options are outlined in the diagram below.
5.1) Additional Outputs
Additional fused power outputs can be added using the expansion board PP4F. One or more boards can be added as long as the
total current drawn does not exceed PCB (10A) or fire relay (8A) limits.
If current draw exceeds limitations an additional PP8FR module can be used.
5.2) Additional Modules
The N/C auxiliary fire relay output (A – A) can be used to provide the fire trip for an additional PP8FR module. This allows expansion
either locally or remotely to elsewhere in a building.
The fire trip for extra PP8FR modules can also be powered from the fire power output expansion terminals (P2) or from a fused
output (P3)
5.3) Other Fire Equipment
Often there will be other equipment requiring a fire trip. Devices such as BMS components, auto doors, lifts and legacy security fire
equipment can be given a fire trip interface either from the auxiliary fire relay output (A – A), from the expansion output or from a
fused output.
P S
2K26K8
PR
P S
4K7 4K7
PR
P S
4K7
PR
F1J1
F2J2
F3J3
F4J4
F5J5
F6J6
F7
J7
F8J8
KF
P1
P2
P3
JR
F9 SPARE
F10 SPARE
REFER TO DATA
BEFORE USE
DF
V In
Aux Out
BAA
JF
P
PR
S
JDC
Fire Relay
Power Port 8FR
DC
Power
Supply
N/C
FIP
Contact
Controller/Field
Equipment Power
F1J1
F2J2
F3
J3
F4
J4
P1
P2
F5 SPARE
REFER TO DATA
BEFORE USE
Vin
Power Port 4F
F1
J1
F2J2
F3
J3
F4J4
F5
J5
F6J6
F7J7
F8J8
KF
P1
P2
P3
JR
F9 SPARE
F10 SPARE
REFER TO DATA
BEFORE USE
DF
V In
Aux Out
BAA
JF
P
PR
S
JDC
Fire Relay
Power Port 8FR
Additional Fire Relay
Or PP8FR
Fire Trip
Alarm
Output
Controller/Field
Equipment Power
Further Expansion
Further Expansion
DC
Power
Supply
4
© Copyright 2011 – Jack Fuse PP8FR Installation Notes
6) Fuse Selection & Replacement
M205 fuses are used for each output. Two spare fuse holders are available on board. The constant current drawn from an output
must not exceed 2.5A however up to a 3A fuse may be used as the PP8FR can accept slightly higher output current for a very short
time. Fuses must be selected to match field device, power supply and cable specifications.
A blown fuse is identified by the LED indicator turning off. Remove the blown fuse by gently levering out the fuse with a flat blade
terminal screwdriver or fuse puller placed under the centre of the fuse, then clip in a replacement fuse of the same type and rating.
7) Technical Data
Input voltage range
0
-
30
V
DC
Fire relay coil
voltage
12
-
2
4
VDC
Max standard power current
8
A
Max fire power current
8
A
(with supplied relay)
*
Max current per output
2
.5
A
Max
alarm contact
c
urrent
2A
Fused o
utputs
8
Fuse t
ype
M205
2A NB
Mounting
DIN rail mounts
supplied. (see section 1)
On board spare f
use holders
2
Dimensions
(with relay
and
mounting
clips
)
110
L
X
75
W X
50
H (mm)
Mounting h
oles
8 X
3.5mm (to suit M3 screws and bolts)
*Peak current only – resistive load. A 20% load current margin is recommended for fire power current (6.4A). Many devices including electric locks have a higher
current on start up and at other times; this must be accounted for in the peak current. Current ratings are valid for operating temperatures up to 24 degrees C with a
fire trip of 12VDC. Factors such as lock types, external heat and higher fire trip voltages must be taken into account when designing power loads.
Connections
Terminal
Description
Max Conductor Size
(P1) FT
-
FT+
Fire
panel trip interface
2mm
2
(P1)
G
ND
& +
DC power supply input
2mm
2
(P2)
Expansion output
2mm
2
(P3) 1
-
8
Fused outputs
1.5mm
2
(P
4
) A
-
A
Monitoring output
1.5mm
2
(PR)
EOL resistor sockets
1/4
-
1/2 Watt r
esistors
(X2)
LED Indicators
LED
Designator
Description
D1
-
8
Fuse statu
s, on indicates fuse intact and power is available.
DF
Fire relay status
, on indicates relay is active and fire power is available.
PWR
Power is available from the power supply.
More Information
For complete install notes, data sheets and technical support please visit www.jackfuse.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

HILLS RELIANCE Jack Fuse PP8FR Power Port User manual

Category
Security device components
Type
User manual

HILLS RELIANCE Jack Fuse PP8FR Power Port is a fused power distribution module for access control with integral fire trip relay. PP8FR has eight individually fused power outputs with a maximum current of 2.5A per output, and a maximum fire power current of 8A. It provides a failsafe method of fire trip interface with two configurable options for connection to the Fire Indication Panel (FIP): either an N/C (Normally Closed) voltage-free contact or a DC voltage. The on-board fire relay is configurable for 12VDC or 24VDC fire trip input.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI