SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights
of the Insurice Systems are:
• SingleSystem-9lbs.(4.0kg.)
• TwinSystem-19lbs.(8.5kg)
• TripleSystem-27lbs.(12kg)
• QuadSystem-36lbs.(20kg)
2. Thelocationshouldallowfor:
• Minimumclearanceof2-1/2”underthecartridge(s)soitcanbeloweredforremovalandre-
placement.
• Adequatespacefor“in”and“out”waterlineconnections.
• Benearadrainforushingandneara110Voutletiftheaccessory(soldseparately)Everguard
LowPressureAlarmisused.SeeFigures1-4.
3. Ifpossible,keepatleast6”availabletotheleftandtherightoftheInsuriceSystemintheevent
poorqualitywaterconditionsrequiretheinstallationoftheoptionalEverpureK-SeriesPrelter.
OPERATING SPECIFICATIONS*
Combined Model Name
Replacement
Cartridge
Flow Rate Capacity
InsuriceSingle-i2000 i2000 1.67gpm(6.3lpm) 9,000gal(34,000L)
InsuriceSingle-i2000
2
i2000
2
1.67gpm(6.3lpm) 9,000gal(34,000L)
InsuriceSingle-i4000 i4000 1.67gpm(6.3lpm) 12,000gal(45,420L)
InsuriceSingle-i4000
2
i4000
2
1.67gpm(6.3lpm) 12,000gal(45,420L)
InsuriceTwin-i2000 i2000 3.3gpm(12.6lpm) 18,000gal(68,000L)
InsuriceTwin-i2000
2
i2000
2
3.3gpm(12.6lpm) 18,000gal(68,000L)
InsuriceTwin-i4000 i4000 3.3gpm(12.6lpm) 24,000gal(90,840L)
InsuriceTwin-i4000
2
i4000
2
3.3gpm(12.6lpm) 24,000gal(90,840L)
InsuriceTriple-i2000 i2000 5.0gpm(18.9lpm) 27,000gal(102,000L)
InsuriceTriple-i2000
2
i2000
2
5.0gpm(18.9lpm) 27,000gal(102,000L)
InsuriceTriple-i4000 i4000 5.0gpm(18.9lpm) 36,000gal(136,260L)
InsuriceTriple-i4000
2
i4000
2
5.0gpm(18.9lpm) 36,000gal(136,260L)
InsuriceQuad-i2000 i2000 6.6gpm(25lpm) 36,000gal(136,260L)
InsuriceQuad-i2000
2
i2000
2
6.6gpm(25lpm) 36,000gal(136,260L)
InsuriceQuad-i4000 i4000 6.6gpm(25lpm) 48,000gal(181,680L)
InsuriceQuad-i4000
2
i4000
2
6.6gpm(25lpm) 48,000gal(181,680L)
*Forindividualcartridgespecications,refertocartridgeliterature.
Temperature: 35-100°F(2-38°C)
Pressure: 10-125psi(0.7-8.6bar),non-shock
Forcoldwateruseonly.
Figure1–InsuriceSingleSystem
EV3112-81RevEAP08
Installation and Operation Guide
Insurice Filter Systems
ManufacturedbyEverpure
Figure2–InsuriceTwinSystem
Figure4–InsuriceQuadSystem
Figure3–InsuriceTripleSystem
INSTALLATION
1. Usethepredrilledmountingholesinthemanifoldbracketasguides.Markanddrillanchorholes.
Mountsecurely.SeeFigures1-4.
2. Shutoffpowertomachine.
3. ConnectoutletportofInsuricesystemtoequipmentserved.AlwaysuseaNSFapprovedpipedope
orTeontapeatallconnections.Useabackupwrenchonallttingswhileconnectingtoavoid
excessive stress on the system components.
Note: If the optional E-Series Filter is used, install a manual shut-off valve leading to the system
for servicing.
4. Connectminimum3/8”waterlinetoinletsideofInsuricesystem.
5 Connecttubingtoushingvalveandruntodrain.
Note: Some municipal plumbing codes and good sanitary practices require an air gap at the drain
termination point.
6. Installthecartridge(s)intotheInsuricesystemhead(s)followingdirectionsonthecartridgelabelor
asshownintheCartridgeChangeillustrations.
7. Turnonwatertolterandcheckforleaks.
8. Flushthecartridgebyrunningwaterthroughatfullforceforveminutes.Thiswillsettheltering
mediaandpurgeairandnes,insuringmaximumlterlife.
9. Afterushing,closetheushingvalve,turnonpowertoequipmentandplugtheLPA(ifso
equipped)intotheelectricaloutlet.Seeillustrations.
CARTRIDGE CHANGE DETERMINATION
Replacecartridgeswhencapacityisreached,orwhenowbecomesinadequate,butatleastannually.
Allcartridgesonmultiplecartridgesystemsshouldbechangedatthesametime.TheEverpure
PressureGaugeorEverguardLowPressureAlarmprovidesaquickandsimplemeansofdetermining
whentheltercartridge(s)shouldbechanged.Installedontheoutletportofthelter,thegauge
orEverguardLPAcanbeusedtomeasurebothdynamic(owing)andstatic(line)pressure.The
cartridge(s)shouldbechangedwhenthepressuregaugeneedleisintheredareawhileequipment
isinoperation,andyettheneedleshowsadequatelinepressurebetweencycles.Observetheneedle
duringthenextequipmentoncycle.Iftheneedleregistersadequatepressure,itcanbeassumedthat
thetemporarylow-pressureconditionwascausedbyabriefpowerfailureorotherincomingpressure
disruption.
FLUSHING
For maximum life, all carbon filter cartridges must be flushed for five minutes at full flow before use. ALL
NEW CARTRIDGES MUST BE FLUSHED AFTER EACH CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE!
Ifthecartridgesarenew,havebeenproperlyushedandbothneedleandfollowerregisterinadequatepressure,or
theLPAissounding,youmaybeexperiencinginadequatewaterpressureorsomerestrictionmayexistintheinlet
waterline.Ineithercase,theincomingwaterpressuremustbeimprovedtoreceiveoptimumlterlife.
COMPLETECARTRIDGECHANGEINSTRUCTIONSCANBEFOUNDONTHEFILTERCARTRIDGELABEL.
Not for residential use. For food service applications only.
Figure5–InsuriceSingleSystem
OUTLET
3/8" FNPT
INLET
3/8" FNPT
27.50"
5.60"
Figure6–InsuriceTwinSystem
16.60"
OUTLET
3/4" FNPT
INLET
3/4" MNPT
25.26"
Figure8–InsuriceQuadSystem
24.60"
OUTLET
3/4" FNPT
INLET
3/4" MNPT
29.69"
Figure7–InsuriceTripleSystem
21"
OUTLET
3/4" FNPT
INLET
3/4" MNPT
29.26"
Checkforcompliancewithstateandlocallaws
andregulations.Donotusewithwaterthatis
microbiologicallyunsafeorofunknownqualitywithout
adequatedisinfectionbeforeorafterthesystem.Systems
certiedforcystreductionmaybeusedondisinfected
watersthatmaycontainlterablecysts.
CARTRIDGE CHANGE PROCEDURE
Everpure Carbon Filter Cartridge
Change
1. Shutoffpowertoequipment.Shut
off inlet water ahead of system.
2. Openushingvalvetorelieve
pressure.
3. Holdheadrmlyandpushupward.
Turncartridgetoleftuntilitstops.
4. Pullcartridgedownwardandoutof
head.
5. Holdheadrmly.Aligncartridge
lugwithlabel.Insertnewcartridge
firmly into head.
6. Turncartridgeright90˚until
rotation stops.
7. Repeatsteps3-6forremaining
cartridges.
Flushing
8. Withushingvalvefullyopen,open
inlet water at full force for five
minutes.Closeushingvalve.
9. Turnonpowertoequipment
PRESSURE GAUGES
Low Inlet
Pressure
Adequate Inlet
Pressure
Low Outlet
Pressure
Adequate Outlet
Pressure
For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed
plumber for installation of the system. This system and its installation must comply with state and local regulations.
REPLACEMENT PARTS
ContactyourlocalEverpuredealerforltercartridgesorsystem
replacement parts.
Description Part Number
Outlet pressure gauge EV3114-09
Inletpressuregauge(quadonly) EV3114-09
Inletvalve(twin,triple&quad) EV3114-07
Flushingvalve EV3114-07
System Tested and Certied by NSF International against
NSF/ANSI Standards 42 and 53 for the reduction of:
Standard No. 42 —
Aesthetic Effects
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Particulate Class I: 99.2% reduction of particles
one-half micron and larger in size
Standard No. 53 —
Health Effects
Mechanical Filtration
Turbidity (i2000, i2000
2
Only)
Cyst
Asbestos (i2000, i2000
2
Only)
For sales, replacement components, and service, contact your Everpure dealer or:
Everpure, LLC: 1040MuireldDrive•HanoverPark,Illinois60133•800.323.7873
In Europe: Toekomstlaan30•B-2200Herentals,Belguim
In Japan: HashimotoMNBldg.7F•3-25-1HashimotoSagamihara-Shi•Kanagawa229-1103,Japan
PrintedinU.S.A. EV3112-81RevEAP08
Technical Service
800.942.1153
www.everpure.com
LIMITED WARRANTY
COMMERCIAL WATER TREATMENT EQUIPMENT
Youhavejustpurchasedoneofthenestwatertreatmentunitsmade.AsanexpressionofourcondenceinEverpureproducts,thisproductiswarrantedagainstdefectsin
materialandworkmanshiptotheoriginalend-userwheninstalledinaccordancewithEverpurespecications.Thewarrantyperiodcommencesfromthedateofpurchase
and is administered as follows:
For a period of ONE YEAR Replaceable elements (i.e., filter & water treatment cartridges)*
For a period of FIVE YEARS The entire system (excluding replaceable elements)
*This is for material & workmanship, not filter or water treatment cartridge life.
TheunitmustbeusedinoperatingconditionsthatconformtoEverpure’srecommendeddesignguidelines.Thiswarrantywillnotapplyiftheunithasbeenmodied,repaired
oralteredbysomeonenotauthorizedbyEverpure.
If a part described above is found defective within the specified period, you should notify Everpure technical service at the phone number listed below. Any part
found defective within the terms of this warranty will be repaired or replaced (at Everpure’s discretion) by your local dealer or Everpure technical service. You
pay only freight from our factory and local dealer charges. Any repaired or replaced warranty item will be incorporated under the original warranty terms of the
existing system.
Wearenotresponsiblefordamagecausedbyaccident,re,ood,freezing,ActofGod,misuse,misapplication,neglect,oxidizingagents(suchaschlorine,ozone,
chloraminesandotherrelatedcomponents),alteration,installationoroperationcontrarytoourprintedinstructions,orbytheuseofaccessoriesorcomponentswhichdonot
meetEverpure’sspecications.RefertothespecicationssectionintheInstallationandOperatingmanualforapprovedapplicationparameters.
Ourproductperformancespecicationsarefurnishedwitheachwatertreatmentunit.TOTHEEXTENTPERMITTEDBYLAW,EVERPUREDISCLAIMSALLIMPLIEDWARRANTIES,
INCLUDINGWITHOUTLIMITATIONWARRANTIESOFMERCHANTABILITYANDFITNESSFORPARTICULARPURPOSE;TOTHEEXTENTREQUIREDBYLAW,ANYSUCHIMPLIED
WARRANTIESARELIMITEDINDURATIONTOTHEPERIODSPECIFIEDABOVEFORTHEENTIREWATERTREATMENTUNIT.Asamanufacturer,wedonotknowthecharacteristics
ofyourwatersupplyorthepurposeforwhichyouarepurchasingthisproduct.Thequalityofwatersuppliesmayvaryseasonallyoroveraperiodoftime,andyourwater
usageratemayvaryaswell.Watercharacteristicscanalsodifferconsiderablyifthisproductismovedtoanewlocation.Forthesereasons,weassumenoliabilityforthe
determinationoftheproperequipmentnecessarytomeetyourrequirements,andwedonotauthorizeotherstoassumesuchobligationsforus.Further,weassumeno
liabilityandextendnowarranties,expressorimplied,fortheuseofthisproductwithanon-potablewatersourceorawatersourcewhichdoesnotmeettheconditionsfor
usedescribedintheowner’sguideorperformancedatasheetforthisproduct.OUROBLIGATIONSUNDERTHISWARRANTYARELIMITEDTOTHEREPAIRORREPLACEMENT
(ATEVERPURE’SDISCRETION)OFTHEFAILEDPARTSOFTHEWATERTREATMENTUNIT,ANDWEASSUMENOLIABILITYWHATSOEVERFORDIRECT,INDIRECT,INCIDENTAL,
CONSEQUENTIAL,SPECIAL,GENERALOROTHERDAMAGES.
Somestatesdonotallowtheexclusionofimpliedwarrantiesorlimitationsonhowlonganimpliedwarrantylasts,sotheabovelimitationmaynotapplytoyou.Similarly,
somestatesdonotallowtheexclusionofincidentalorconsequentialdamages,sotheabovelimitationorexclusionmaynotapplytoyou.Thiswarrantygivesyouspecic
legalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.ConsultyourtelephonedirectoryforyourlocalindependentlyoperatedEverpuredealer,or
writeEverpureforwarrantyandserviceinformation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Everpure EV9606-01 User manual

Category
Sanitary ware
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI