Pulsar S64-CR Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Pulsar S64-CR Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
S64-CR
v1.4
S64-CR 6-port switch for 4 IP cameras
in enclosure with recorder space
PL
Edition: 5 from 20.09.2019
Supercedes the edition: 4 from 01.02.2019 EN**
Features:
6 ports 10/100Mb/s
4 PoE ports 10/100Mb/s, (data and power supply)
2 ports 10/100Mb/s (UP LINK)
Long Range mode (up to 250m)
30 W for each PoE port, supports devices complaint
with the IEEE802.3af/at (PoE+) standard
Supports auto-learning and auto-aging of MAC
addresses (1K size)
Recorder space of dimensions max 400x345x95mm
WxHxD
LED indication
The enclosure construction is compliant with
the requirements of the General Data
Protection Regulation GDPR (the possibility
of installing two locks with different codes)
Additional assembly elements (straps for
attaching the DVR in enclosure)
Metal enclosure color white RAL 9003
warranty 2 year from the production date
Example of use.
1. Technical description
1.1. General description.
The S64-CR is a complete kit to build the CCTV system based on IP cameras. The switch is placed in a metal enclosure
with recorder space. The enclosure construction is compliant with the requirements of the General Data Protection
Regulation GDPR (the possibility of installing two locks with different codes).
Automatic detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 4 ports of the switch. The
UP LINK ports is used for connection of another network device via RJ45 connector. The LEDs at the front panel indicate the
operation status (description in the table below).
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a
separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access
point or router.
2
1.2 Block diagram.
Fig. 1. Block diagram.
1.3. Description of components and connectors.
Table 1. (see Fig. 2)
Element no.
(Fig. 2)
Description
[1]
Switch
[2]
Switch mode power supply for the switch (PS-604812) 52 V DC/60 W
[3]
Potentiometer adjusting the output voltage of the power supply (48÷53 V)
[4]
LED light power supply operation indication
[5]
T 6,3 A / 250 V fuse socket
[6]
Mounting brackets for cables
[7]
Space for the power supply of the recorder (desktop type)
of dimensions max. 180x40x100 [mm]
[8]
Power Socket of the 230 V recorder
[9]
Recorder space of dimensions max 400x345x95mm WxHxD
[10]
Straps for attaching the DVR in enclosure
Fig. 2. The enclosure view.
3
Fig. 3. The view switch'a.
Table 2. (See Fig.3)
Component No.
(Fig. 3)
[1]
[2]
[3]
[4]
[5]
1.4. Technical parameters (tab.3)
Table 3.
Ports
6 ports 10/100Mb/s (4 x PoE + 2 x UP LINK)
with connection speed auto-negotiation and MDI/MDIX Auto Cross)
PoE power supply
IEEE 802.3af/at (1÷4 ports), 52 V DC / 30 W at each port *
Long Range mode
Long Range, VLAN
Protocols, Standards
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP
Bandwidth
1,6Gbps
Transmission method
Store-and-Forward
Optical indication of
operation
Switch power supply;
Link/Act;
PoE Status
Mains supply
~200-240 V; 50 Hz; 0,6 A
Operating conditions
temperature -10°C ÷ 40°C,
relative humidity 5% - 90%, no condensation
Dimensions
W=432, H=607, D+D
1
=102+14 [+/- 2mm]
W
1
=437, H
1
=612 [+/- 2mm]
The dimensions of the
recorder compartment
W
2
=400, H
2
=345, D
2
=95 [+/- 2mm]
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
4
Closing
Cheese head screw x 2 (at the front)
The possibility of installing two locks with different codes.
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Gross/Net weight
7,7/8,5 kg
Protection class
EN 60950-1:2007
II (second)
Storage temperature
-20°C ÷ 60°C
Declarations
CE
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 48 W.
2. Installation
2.1. Installation procedure
1. The unit should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a
given country) for 230 V interference and low-voltage installations. It is required to install an installation switch with a
nominal current of min. 3 A in the power supply circuits outside the power supply unit.
2. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative
humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C.
3. The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of
the enclosure. The load balance should be done before installation Switcha. The given value of 30 W per port is the
maximum value referring to a single output. The total power consumption should not exceed 48 W. The increased
demand for power is particularly evident in the case of cameras with heaters or infrared illuminators - when launching
these features, the power consumption increases rapidly, which may adversely affect the operation of the switch. The
device is designed for a continuous operation and is not equipped with a power-switch. Therefore, an appropriate
overload protection in the power supply circuit should be provided. Moreover, the user should be informed how to
disconnect the power supply unit from the mains supply (usually by assigning an appropriate fuse in the fuse box). The
electrical system shall be made in accordance with applicable standards and regulations.
2.2. Long Range mode
Switch enables operation in two modes: standard and extended range. When the Long Range switch is in STANDARD
position (see Fig. 5), PoE ports operate at 100 Mb / s up to 100 meters. After switching to EXTEND position, range is increased
to 250 meters and speed is reduced to 10 Mb / s. Additionally, VLAN function, which isolates the PoE ports between each other
(communication takes place between the UpLink ports and individual PoE), is activated. In both modes, the UpLink port speed
is 100 Mb / s.
Note: Changing the modes requires a power restart!
2.3. Installation procedure
Before installation, cut off the voltage in the 230 V power-supply circuit.
To switch power off, use an external switch, in which the distance between the contacts of all
poles in the disconnection state is not less than 3mm.
1. Mount the PSU in a selected location and connect the wires.
2. Connect the power cables (230 V) to the L-N terminals of the power supply.
The shock protection circuit shall be performed with a particular care, i.e. the yellow
and green wire coat of the power cable shall stick to one side of the terminal - marked
with symbol on the PSU enclosure. Operation of the PSU without the properly made
and fully operational shock protection circuit is UNACCEPTABLE! It can cause a
device failure or an electric shock.
3. Connect the ground wire to the terminal marked by the earth symbol (power supply module connector).
Use a three-core cable (with a yellow and green protection wire) to make the connection. Lead the cables to the
appropriate terminals of the connection board through the insulating bushing
4. Connect the power (230 V).
5. Connect the camera wires to the RJ45 connectors (PoE connectors).
6. Check the optical indication of the switch operation.
7. After installing and checking proper working, the enclosure can be closed.
5
Connection schemes.
6
3. Optical indication of the switch operation (see Table 4).
Table 4. Indication of the switch operation
OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY
GREEN LED LIGHT (Power)
Indication of the switch's
power supply
OFF no power supply of the switch
ON power supply on, normal operation
OPTICAL INDICATION AT THE PoE PORTS (1÷4)
GREEN LED LIGHT (PoE)
Indication of the PoE power
supply at the RJ45 ports
OFF- no power supply at the RJ45 port (the device is not connected
or not compliant with the IEEE802.3af/at standard)
ON supply at the RJ45 port
Blinking short-circuit or output overload
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10MB/s or 100Mb/s
and data transmission
OFF- no connection
ON - the device is connected; 10Mb/s or 100Mb/s
Blinking data transmission
OPTICAL INDICATION AT THE UP LINK PORTS
GREEN LED LIGHT
Port on the left side:
No lit - no voltage
Lit switch operates properly
Port on the right side:
No lit switch operates in normal mode
Lit Long Range mode active
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10MB/s or 100Mb/s
and data transmission
OFF- no data transmission
ON - the device is connected: 10Mb/s or 100Mb/s
Blinking data transmission
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal household waste.
According to the European Union WEEE Directive, waste electrical and electronic equipment should be
disposed of separately from normal household waste.
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
http:// www.pulsar.pl, www.zasilacze.pl
/