tekmar 4 Thermostat 537 , 537 Quick Set-up

  • Hello! I am an AI chatbot trained to assist you with the tekmar 4 Thermostat 537 Quick Set-up. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
© 2014 537_Q - 02/14
1
A Watts Water Technologies Company
1. Location
2. Remove Mounting Base
3. Install Mounting Base
Thermostat
Base
Adaptor
Plate 007
Switch
Box
OR
Thermostat
Base
Wall
Exterior
Wall
Interior
Wall
5 feet
1.5 m
tekmarNet
®
4 Thermostat 537
Quick Setup Guide
537
_
Q
02/14
Zoning
Replaces: 12/13
© 2014 537_Q - 02/14
2
A Watts Water Technologies Company
4. Wiring
5. Switch Settings
12 34
tN4 Wiring Center
or
tN4 Zone Manager
tN4 C W
R
123
4
tNt 537
537
One Stage Heat
Mmm YYYY
Lot 12345
Meets Class B:
Canadian ICES
FCC Part 15
Power: 24 V ±10% 50/60 Hz 1.8 VA
56 VA fully loaded
Relay: 24 V (ac) 2 A
1001-02
tN4
1
C
2
R
3
W
4
Switch Settings:
For instructions see brochure
Use at least 75°C conductors
Setback
Scene
Lock
ON
Unlock
Off
Off
Not usedNot used
Switch
Setting
Location
Switch
Position
Action
1
ON
SETBACK Allow thermostat to respond to
available schedule. Requires Timer 033.
OFF OFF No setback schedule response.
2
ON
SCENE Allow thermostat to respond to
scenes. Requires User Switch 479.
OFF OFF No scene response.
3
ON
LOCK Locked to ‘User’ access level. Set to
Lock when installation completed.
OFF
UNLOCK Unlock to access all settings. Set
to Unlock during installation.
4
ON Not used
OFF Not used
© 2014 537_Q - 02/14
3
A Watts Water Technologies Company
6. Close Thermostat
pivot
tab
8. Critical Settings
The following settings are essential to the successful operation of the system.
Important
Note: Set switch setting #3 and tekmarNet
®
system control to Unlock to change
Access level to Installer. Return to Lock setting once installation has been completed.
Press and hold down both the and buttons for 2
seconds to change from one step to the next.
Release both buttons once the step has been reached.
• Press the or the button to change the setting, if
available.
Press and hold down both the and buttons for 2
seconds to go to the next step, OR
After 10 seconds of no button activity, the display goes
back to normal operation.
Press
+
Together
7. User Interface
All specifications are subject
to change without notice
4 537_Q - 02/14.
Product design, software and literature are Copyright ©2014 by tekmar Control Systems Ltd.,
A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C.
Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650
Web Site
: www.tekmarControls.com
For a full list of settings and operational details, please refer to the thermostat
Installation and Operation Manual (537_D) included with compatible
tekmarNet
®
controls or download the brochure from www.tekmarcontrols.com
8. Critical Settings (Continued)
Display Range Access Description
°F or °C
Default =
°F
Installer
User
TEMPERATURE UNITS
Press the or the button to
change from °F to °C and vice
versa.
Set To:
H1
H1
ADJUST
ADJUST
SUPPLY
OFF or On
Default =
On
Installer
HEAT SUPPLY PUMP
During heating, select whether or
not the system supply pump should
turn on or be off to allow a zone
group pump per manifold.
Available when:
• A reset control is present on
the tekmarNet
®
system.
Set To:
H1
H1
ADJUST
ADJUST
SUPPLY
OFF or On
Default =
OFF
Installer
HEAT SUPPLY PUMP DELAY
During heating, select whether or
not the system supply pump should
be delayed by 3 minutes before
coming on (for thermal motor or
wax actuator).
Available when:
• A reset control is present on
the tekmarNet
®
system.
Set To:
© 2014 537_Q - 02/14
5
Une Entreprise de Watts Water Technologies
1. Emplacement
2. Retirez la base de montage
3. Installez la base de montage
Mur extérieur
Mur intérieur
5 pi.
1,5 m
Commutateur
boîte
OU
Mur
Base de
thermostat
Plaque
adaptrice 007
Base de
thermostat
tekmarNet
®
4 Thermostat 537
Guide d'installation rapide
537
_
Q
02/14
Zonage
Remplace: 12/13
/