Lightolier Slot Grid Ceiling Systems User manual

Category
Flat panel ceiling mounts
Type
User manual
Fixture
End Cap (In collapsed position)
DIMENSIONS
1
24"
(610mm)
BALLAST COVER
To remove Ballast Cover, loosen or remove screw.
Ballast Cover has a keyhole slot at opposite end.
3
2-1/4" (64mm)
24" (610mm)
2-1/4" (64mm)
48" (1219mm)
24"
(610mm)
1-9/16" x 2-13/16"
Access Plate with
(2) 7/8" Dia. K.O.s
BASKET
Remove Basket by pulling on one side
(both ends) clearing the Hinge Pins.
Rotate the Basket up and clear the Hinge
Pins on the opposite side. To install the
Basket, reverse the instructions.
2
Hinge
Pin
Fixture
Hinge
Pin
Ballast
Cover
Ballast
Housing
Screw
End
Cap
Fixture
4
1-9/16" x 2-13/16"
Access Plate with
(2) 7/8" Dia. K.O.s
END CAPS (T8 ONLY)
Rotate End Cap down (both ends) to clear ceiling
opening during installation into the ceiling system.
45 Industrial Way, Wilmington, MA 01887 (978) 657-7600 • Fax (978) 658-0595
We reserve the right to change details of design, materials and finish. www.lightolier.com
This product may have a mercury containing lamp. Manage in acco dance
with Disposal Laws. See: www.lamprecycle.o g
Lightolier is a Philips group brand
Coffaire Drop Basket
Installation Instructions
Standard or Slot Grid Ceiling Systems
Fixture
End Cap
T8 Only
(In collapsed position)
5
6
FIXTURE INSTALLATION
Angle Fixture up into ceiling opening resting
Fixture on Ceiling Tee (by others). Return End
Caps to open position (Detail A, T8 Only) for
lamping and installation of Perforated Basket.
Make wiring connections.
Ceiling Tee
(by others)
Ceiling
Opening
Lamp
Holder
End
Cap
Detail A
7
EARTHQUAKE CLIP (For 2' x 2' / 2' x 4' only)
With Screw secure Earthquake Clip to Fixture
with Ceiling Tee (by others) between Earthquake
Clip and Fixture as shown.
Earthquake
Clip
Screw
Ceiling Tee
(by others)
Screw
Ceiling Tee
(by others)
Earthquake
Clip
ACCESS PLATE
Remove Access Plate, when desired by
sliding Access Plate in the direction of Arrow 1. Lift
up and slide Access Plate in the direction of Arrow
2. Bend Housing Tab up out of Ballast Housing,
make ground connection. Bend Ballast Housing Tab
back to original position. Replace Access Plate by
reversing the removal instructions.
Access
Plate
Tab
Ground
Screw
Ballast
Housing
Tab
Access
Plate
Opening
Ballast
Housing
1
2
59-31165-000 Printed in U.S.A.
Lightolier is a Philips group brand
  • Page 1 1