NXP TEA19032BT User guide

Type
User guide

This manual is also suitable for

UM11014
TEA190x evaluation overdrive (TEO)
Rev. 2 — 16 November 2018 User manual
Document information
Information Content
Keywords TEA190x, TEA1903, TEA1905, demonstration kit, Teo, UTC, software
Abstract This user manual describes the TEA190x demonstration kit. The TEA190x
demonstration kit includes software to view and change the configuration of
the TEA190x. The software also shows live data, such as USB-PD messages,
bus voltage, and current. The software is called Teo (TEA190x evaluation
overdrive). It incorporates a graphical user interface (GUI) and several
libraries to communicate with the TEA190x family and monitor USB-PD traffic.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
2 / 35
Table 1. Revision history
Rev Date Description
v.2 20181116 second issue
Modifications: The text has been updated throughout the document.
The graphics have been updated throughout the document.
v.1 20170223 first issue
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
3 / 35
1 Introduction
Warning
The non-insulated high voltages that are present when operating this product,
constitute a risk of electric shock, personal injury, death and/or ignition of fire.
This product is intended for evaluation purposes only. It shall be operated in a
designated test area by personnel qualified according to local requirements and
labor laws to work with non-insulated mains voltages and high-voltage circuits. This
product shall never be operated unattended.
This user manual describes the TEA190x family demonstration kit. The TEA190x
demonstration kit includes software to view and change the configuration of the
TEA190x. The software also shows live data, such as USB-PD messages, bus voltage,
and current. The software is called Teo (TEA190x evaluation overdrive, second
generation) and incorporates a graphical user interface (GUI) and several libraries to
communicate with the TEA190x and monitor USB-PD traffic.
Screen pictures may differ due to small software upgrades. If major upgrades occur, this
document is updated as well.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
4 / 35
2 Safety warning
The TEA190x is AC mains voltage powered. Avoid touching the board while it is
connected to the mains. An isolated housing is obligatory when used in uncontrolled,
non-laboratory environments. Galvanic isolation from the mains phase using a fixed or
variable transformer is always recommended. Figure 1 shows the symbols on how to
recognize these devices.
019aab173
019aab174
a. Isolated b. Not isolated
Figure 1. Isolation symbols
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
5 / 35
3 Kit content
The TEA190x demonstration kit contains the following items:
Demo board: A complete USB-PD source device
UTC: A monitoring and sink device.
Teo: Configuration and monitoring software for Microsoft Windows
A type-C male-male cable: Connects UTC with the TEA190x.
A type-B to micro-B USB cable: Connects UTC to a PC.
A USB-OTG adapter: For upgrading the UTC firmware.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
6 / 35
a. TEA190x demo board b. UTC - USB-PD interface
c. Teo - PC software
Figure 2. TEA190x demonstration kit contents
Note: Several demo boards with different configurations exist. The picture shown in
Figure 2 may differ from the board in the demo kit.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
7 / 35
3.1 Other requirements
The demo board is preconfigured. It works out of the box. Teo runs on a PC with
Microsoft Windows. The demo board configuration can be changed. To change the
configuration, Teo is required. If the evaluation of the TEA190x is done with a USB-PD
sink, a number of options are available.
Use UTC as a USB-PD sink. Teo configures UTC to act as a USB-PD sink. The
communication between TEA190x and UTC is shown in Teo. Optionally, a load (either
an electronic or resistive one) can be connected to UTC and draw current from the
TEA190x.
Connect a USB-PD sink and use UTC to monitor the communication between sink and
TEA190x. Teo shows the USB-PD messages from and to the TEA190x.
Connect a USB-PD sink and use external protocol analyzers to monitor the
communication between sink and TEA190x. Teo can still be used to change the
configuration of the TEA190x.
3.2 Compatibility
Teo is available for Windows 7, Windows 8, Windows 8.1, and Windows 10. 64-bit and
32-bit versions are supported.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
8 / 35
4 Quick start
This section provides the information to get started as quickly as possible. It does not
replace other information elsewhere in this document. Read the remainder to get the
most out of the demonstration kit.
4.1 Requirements
To get the board working:
TEA190x demo board (TEA190x demonstration kit)
An AC mains power source, 110 V to 240 V (AC), 50 Hz to 60 Hz
A set of wires for connection to the AC mains power source
To change settings of TEA190x:
Teo, PC software for TEA190x (TEA190x demonstration kit)
One of the TEA190x data sheets (TEA190x demonstration kit)
A PC running Microsoft Windows 7 or higher
To monitor the TEA190x:
Preferred device to connect with TEA190x, or
A simulated sink such as UTC and Teo (TEA190x demonstration kit), or
A lab with the required equipment
4.2 Before installing the PC software for the TEA1905
Leave the demo board disconnected for now.
Leave UTC disconnected for now.
Windows installs driver packages for both hardware interfaces. When the hardware
interfaces are plugged into one of the USB ports for the first time, the drivers are installed
automatically.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
9 / 35
4.3 Installing the PC software
While installing the PC software, leave UTC disconnected.
Run the installer wizard “Install_Teo_x_y_z.exe”. X, y, and z indicate the version
number of Teo.
Follow the instructions of the installer wizard.
Two sets of drivers are installed. During the installation, messages may appear on the
screen asking to trust an unknown publisher. To continue the drivers initialization, confirm
by clicking "Yes".
In most cases, the drivers are installed instantaneously. However, sometimes a reboot
may be required. If a reboot is required, a message appears on the screen. Reboot your
PC before continuing with the next step.
4.4 Connecting the demo board to the PC
Connect UTC to the PC with the supplied USB cable. Connect the demo board to UTC
with the supplied type-C cable.
Teo recognizes UTC and lets you configure UTC to be used as a USB-PD sink or
USBPD Sniffer.
As a safety precaution, use a type-C cable to connect the TEA190x with a device. Plug
the type-C cable into the TEA190x board before supplying the mains power source.
Use the other end to connect a device. In this way, the high voltages on the board are
avoided.
Note: Even after disconnecting the charger from the mains supply, the large capacitor
keeps it charged with a high voltage for hours.
4.5 How to use the software
The software, Teo, shows a number of tabbed pages of controls:
Basic: Always visible
Advanced: Always visible
Protection: Always visible
Extended SrcCaps: Visible when USB-PD 3 is supported
Sink or sniffer: Only visible when UTC is connected
The last tabbed page, Sink, or Sniffer, is designed for UTC. If UTC is connected, Teo
configures UTC to be used as a USB-PD sink or as a USB-PD sniffer. By default, UTC
boots in sniffer mode. See Section 5.2, for more information about UTC. If UTC is
disconnected, the last tab is hidden.
With the first four pages, changes can be made to the configuration of the TEA190x. If a
connection via UTC exists, the changes can be written and stored.
When the configuration is changed, the TEA190x must be restarted for those changes to
take effect. The "Soft restart" button on the Basic page restarts the TEA190x.
The requested voltage and current can be changed on the Sink tab. A hard reset or
soft reset can be performed. When a new voltage request has been inserted, press
Enter or Tab to cause the change to take effect. Clicking one of the PDOs, requests the
corresponding voltage.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
10 / 35
Captured USB-PD messages between the TEA190x and the USB-PD sink are listed on
the Sniffer tab.
If Teo fails to recognize the demo board, choose Scan interfaces from the Options
menu, to have Teo look again for known interfaces. Select the desired interface from the
Interface menu under Options.
When an interface is selected, Teo attempts to set up a connection with the TEA190x. If
the connection setup is successful, Teo reads all settings from the MTP memory.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
11 / 35
5 Hardware
The TEA190x demonstration kit incorporates a fully operational USB-PD source. It also
contains UTC, a peripheral device to change and monitor the behavior of the TEA190x.
5.1 The TEA190x demo board
The TEA190x demo board has a primary and secondary supply. The primary side is
connected to a mains source from 110 V (AC) to 240 V (AC) with wires. The frequency is
50 Hz or 60 Hz (see one of the TEA190x data sheets for the complete specification).
The secondary stage delivers power through a USB type-C female connector.
a. Type-C
b. Mains
Figure 3. TEA1905 demo board
Note: The board in the demonstration kit may look different from the pictures shown in
Figure 3.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
12 / 35
5.2 UTC
UTC (USB-PD Type-C controller) includes a micro-USB receptacle, a male type-C
connector, and a female type-C connector. The micro-USB receptacle can be connected
to a type-B connector on the PC with the cable supplied.
UTC receives operating power and communicates with Teo via the micro-USB
connection. In essence, the only difference between the two type-C connectors is the
gender. It allows UTC to be connected between a USB-PD source and sink.
UTC has access to the CC lines, can monitor and inject USB-PD messages, and
measures voltage and current on V
bus
.
UTC operates in two different modes:
Sink
Sniffer
5.2.1 Sink mode
In sink mode, UTC acts as a USB-PD sink. It responds to a source being attached or
detached, just like a normal USB-PD sink does. UTC negotiates a contract and sends the
messages and state changes to Teo.
5.2.2 Sniffer mode
In sniffer mode, UTC ‘sits’ in the middle. It is invisible to both the TEA190x and the USB-
PD sink. USB-PD messages from/to the TEA190x are captured and sent to Teo.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
13 / 35
6 Software
The demonstration kit includes software to view and change the configuration of
TEA190x. The software also shows live data, such as USB-PD messages, bus voltage,
and current. The software is called TEA190x evaluation overdrive (Teo). To communicate
with TEA190x and monitor USB-PD traffic, it includes a graphical user interface (GUI)
and several libraries.
6.1 Installation
Teo, its libraries, and drivers are installed with a single installation wizard.
When the installation wizard is launched, the Windows user account control may ask if
you trust the application from an unknown publisher (see Figure 4). Click Yes to proceed
with the installation.
Figure 4. Windows user account control
The installation wizard can be run without deinstalling an existing installation. In this
way, for example, a broken installation can be fixed or an earlier failed attempt can be
completed.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
14 / 35
Figure 5. Teo installation wizard
Note: Use Windows control panel to uninstall Teo.
6.1.1 Before installing the PC software for the TEA1905
Leave the demo board disconnected for now.
Leave UTC disconnected for now.
Driver packages for UTC are installed. When UTC is plugged into one of the USB ports
for the first time, the drivers are installed automatically.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
15 / 35
6.1.2 Installing the PC software
While installing the PC software, leave UTC disconnected.
Run the installer wizard “Install_Teo_x_y_z.exe”. X, y, and z indicate the version
number of Teo.
Follow the instructions of the installer wizard.
During installation, you may be asked to trust the software publisher twice. Confirm with
Yes to continue the driver package installation.
A progress dialog appears while the driver packages are installed.
Most likely, the software is installed and ready to use instantaneously. However, in some
cases a reboot is required. If a reboot is required, a message is shown. In that case,
reboot your PC to finish the installation.
6.2 User interface
Teo has a number of tabbed pages, each with a number of controls. The pages Basic,
Advanced, and Protection, show the contents of the MTP memory of the TEA190x.
These controls visualize the parameters of the settings of the device. They allow the user
to modify their values. Some parameters are specific for certain devices. So, the layout
may vary per device and differ from the screenshots in this document.
A fifth tabbed page is reserved for UTC.
Figure 6. Settings
The Basic page contains the definition of seven PDOs and a number of hardware and
software configuration settings. See the TEA190x data sheets for an explanation of these
settings.
Figure 7. Basic tab: PDOs
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
16 / 35
If UTC is connected, live data is shown at the bottom of the Basic page.
The actual V
bus
voltage and current measured by UTC and the firmware version of the
device are shown. The Soft Restart button reboots the demo board.
For more details on UTC, see Section 6.6.
Figure 8. Voltage and current
The Protection page contains all settings that deal with protection against high
temperatures, overvoltage, undervoltage, and overcurrent.
Figure 9. Protection page
The Advanced page contains less frequently changed settings and settings that require a
thorough understanding of their purpose. The settings that deal with the discharge curve
are grouped in a separate box. For more details, see the TEA190x data sheets.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
17 / 35
Figure 10. Advanced page
The Extended SrcCaps page contains parameters that deal with USB-PD 3 extended
source capabilities. This page is only visible if USB-PD 3 compatibility is enabled on the
Basic page.
Figure 11. Extended SrcCaps page
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
18 / 35
6.3 Connecting Teo to the demo board
Teo can read and update the configuration of the TEA190x on the demo board. The
configuration is stored in MTP memory. The MTP memory is accessible via the type-C
receptacle and vendor defined messages (VDM). For more information on MTP memory,
see Section 6.4.2, and Section 6.4.
To read and write MTP memory, Teo requires UTC in sink mode and a PD contract
between UTC and the demo board.
At start-up, Teo looks for UTC and initializes the connection if one is found. If UTC is
unavailable at start-up, the Sink and Sniffer page are hidden and the UTC controls are
disabled.
Whenever a USB device is inserted or removed, Teo automatically scans for known
hardware interfaces. Optionally, Teo can be instructed to look for UTC and other
interfaces with the menu option: Options > Scan interfaces.
Figure 12. Menu option: Options > Scan interfaces
In addition to UTC, a few other interfaces are supported and may be available in
the Options > Interface menu. Support for Aardvark, FT201XM, FT232H, and two
hardwareless emulators are built in. The Hardwareless simulators are not real interfaces.
The only purpose of the simulators is to demonstrate the software without any external
hardware.
When an interface is ready to use, Teo attempts to communicate with the TEA190x. It
tries to set up a remote function call (RFC) protocol. If successful, Teo proceeds with
reading the MTP memory contents and updating the tabbed pages accordingly.
The status bar at the bottom of the main window of Teo shows information about the
current connection. The text in the status bar shows the name of the interface and
optionally, version information or serial numbers. The icon in the left corner shows a plug
and receptacle. If the two are connected, a valid connection has been set up and the
entire MTP memory is read. If a connection could not be established or reading of MTP
memory failed, the icon shows a disconnected plug and receptacle. During initialization of
the RFC protocol, the text "Initializing..." is shown. When reading the MTP memory, the
text "Reading settings…" is shown.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
19 / 35
a. Connected
b. Communication error
c. Disconnected
Figure 13. Teo software: Status bar
Note: The TEA190x demo board must be powered on and UTC must have established a
PD contract before the MTP memory can be accessed.
6.4 Configuration
6.4.1 Configuring UTC for communication
To communicate with TEA190x, UTC must be in sink mode. If UTC is in sink mode, a
tabbed page Sink is visible. If UTC is in sniffer mode, a tabbed page Sniffer is visible. If
UTC is disconnected, the Sink and Sniffer pages are invisible.
To switch UTC from sniffer to sink mode, select Options > UTC > USB-PD sink from the
menu or press the Battery button on the toolbar.
When UTC connects to the PC, it always starts up in sniffer mode. In this way,
interference with a USB-PD sink that might be connected already is prevented.
Whenever it connects to the PC, Teo can automatically change UTC to sink mode. If
UTC is primarily used as a USB-PD sink, check the menu Options > UTC > Configure as
Sink on connect.
NXP Semiconductors
UM11014
TEA190x evaluation overdrive (TEO)
UM11014 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2018. All rights reserved.
User manual Rev. 2 — 16 November 2018
20 / 35
Figure 14. Menu Options > UTC > Configure as Sink on connect
When UTC is in Sink mode, it negotiates a power contract with TEA190x automatically.
For more details about changing UTC settings in Sink mode, see Section 6.6.1. A power
contract is mandatory for communication between Teo and TEA190x. When a power
contract exists, Teo communicates with TEA190x through remote function calls (RFC)
over vendor defined messages (VDM).
Notes:
- In sniffer mode, UTC only listens to USB traffic and does not participate in
communication.
- Only one USB-PD sink at a time can be attached to a USB-PD source.
6.4.2 Reading the configuration
When Teo starts up and a TEA190x is connected, the MTP memory is read
automatically. You can manually read/reread the MTP memory, by choosing Options >
Read MTP. Teo always reads the entire MTP memory.
Figure 15. MTP progress
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

NXP TEA19032BT User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI