White Mountain Hearth Rushmore 50 Conversion Kit Propane to Natural Gas (38227) Owner's manual

Type
Owner's manual
40024-0-1118 Page 1
WARNING
This conversion kit must be installed by an Empire Comfort Systems distributor (or other
qualied agency¹)*in accordance with the manufacturers instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualied agency performing this work assumes
responsibility for this conversion.
1National Fuel Gas Code Z223.1 (Latest Edition)
*The term “qualied individual, rm, corporation or company which either in person or through
a representative is engaged in and is responsible for (a) the installation of gas piping or (b)
the connection, installation repair, or servicing of equipment, who is experienced in such
work, familiar with all precautions required, and has complied with all the requirements of the
authority having jurisdiction.
CHECK SAFETY SHUTDOWN PERFORMANCE
WARNING
Perform the safety shutdown test anytime work is done on a gas system to avoid the possibility
of re or explosion with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilotgasowshouldstopwithin30seconds.
PARTS LIST
Part Description Conversion Kit Quantity Supplied
MainBurnerOrice,Front P256 1
MainBurnerOrice,Rear P211 1
SIT Gas Valve Conversion Kit R11381 1
Gas Conversion Label 1224 1
Target,Front 40277 1
Target,Rear 40278 1
TOOLS NEEDED:
• StandardScrewdriver
• 1/4 Inch Hex Driver
• 5/16 Inch Hex Driver
• 7/16InchWrench
• 7/16InchDeep
Socket Set
Gas input for direct-vent replace converted to Natural Gas: DVCT50CFP95N
Thedirect-ventgasreplacewhenconvertedtoNaturalGaswillhaveamanifoldpressureofapproximately
3.5inchesw.c.(.871kPa)atthevalveoutletwiththeinletpressuretothevalvefromaminimumof4.5inchesw.c.
(1.120kPa)forthepurposeofinputadjustmenttoamaximumof14.0inchesw.c.(3.484kPa).
INSTALLATION INSTRUCTIONS
DIRECT VENT GAS FIREPLACE
FOR USE ON: DVCT50CFP95P CONVERSION KIT PART NUMBER 38227
FOR CONVERSION TO NATURAL GAS
40024-0-1118Page 2
INSTRUCTIONS FOR CONVERSION
1. Ifthereplaceisinstalled,turnOFFgasandelectricsupply
toreplacebeforemakinggasconversion.AllowFireplaceto
cool completely.
2. Removebarrierscreen,glassdoor,logsandembers,and
liners. See Homeowner's Manual.
Figure 1
3. Removefrontandrearburnersbyremovingscrewsonleft
andpullingouttowardsleftside.See Figure 2.
Figure 2
.
4. Remove(2)screwsholdingpilotassemblytoburnerpan.
Thiswillallowpilotassemblytodrop.
5. Remove(2)screwsholdingburnerbaseinplace.
Liftburnerbaseoutofrebox.See Figure 4.
Figure 4
6. Usea7/16inchdeepsocketsettoremoveorices.
See Figure 5.
REAR
FRONT
Figure 5
7. Locatetheoricemarked"32."Usea7/16inchdeepsocket
settoinstalloricemarked"32"ontorearoriceholder.Use
needle-nosepliers,screwreartargetontorearoriceholder.
See Figure 6.
8. Locatetheoricemarked"41."Usea7/16inchdeepsocket
settoinstalloricemarked"41"ontofrontoriceholder.Use
needle-noseplierstoscrewfronttargetontooriceholder.
See Figure 6.
REAR
FRONT
Figure 6
40024-0-1118 Page3
9. Loosenrearairshutterscrewandrotatehandletotheleft
untilfullyclosedisachievedandtightendownscrew.
See Figure 7.
10.Repeatwithfrontuntilfullyclosed.
REAR AIR
SHUTTER
SCREW
FRONT AIR
SHUTTER
SCREW
CLOSED
OPEN
REAR
FRONT
Figure 7
11. Usea7/16inchopenwrenchtoloosenpilotbodybyslightly
turningcounterclockwise.Slideoricebrackettootherside
andtightenpilotbodyclockwise.See Figure 8.
“NAT” MARKING
Figure 8
12. Replaceitemsremovedinsteps2-5inreverseorder.
13. Turngasandelectricon.
14. Gas conversion is completed.
Checkthemainburnerameandpilotburneramemustbe
checkedforproperamecharacteristics,asoutlinedinthe
InstallationInstructionsandOwner'sManual.
Ifreplaceisnotinstalledorprojectregistrationcardhasnot
beenreturnedtoEmpireComfortSystem’s,checkofftypeof
gasconvertedtoonthecard.Alsoindicateconversionbyadding
“Conv.” behind type of gas.
40024-0-1118Page 4
www.empirecomfort.com
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
aboutourproducts,pleasee-mail
If you have a service or repair
question,pleasecontactyourdealer.