Xantrex Technology Telescope STXR1500 User manual

Type
User manual

This manual is also suitable for

Xantrex
Sun Tie XR
STXR1500
STXR2500
Installation and Operation Guide
Sun Tie XR
Installation and Operation Guide
About Xantrex
Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from
50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup
power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery
chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute
electrical power.
Trademarks
Xantrex is a registered trademark of Xantrex International.
Other trademarks, registered trademarks, and product names are the property of their respective owners and are used
herein for identification purposes only.
Notice of Copyright
Sun Tie XR Installation and Operation Guide © February 2003 Xantrex International. All rights reserved.
Disclaimer
UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. (“XANTREX”)
(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY
TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.
(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT,
INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH
INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.
Date and Revision
February 2003, Revision 1
Part Number
975-0053-01-01
Contact Information
Telephone: 360.435.8826
Fax: 360.925.5143
Email: CustomerService@xantrex.com
Web: www.xantrex.com
About This Guide
Purpose
The Sun Tie XR Installation and Operation Guide contains information for a qualified
installer and authorized service person to install, operate and troubleshoot the Xantrex
Sun Tie XR.
Scope
The guide provides safety guidelines, installation, operation, troubleshooting, and
warranty information for the Sun Tie XR.
The guide does not provide detailed information about solar (photovoltaic or “PV”)
arrays or requirements for connecting to the utility power grid. You will need to
consult the PV array manufacturers guide and your local electrical utility for this
information.
About This Guide
ii 975-0053-01-01
Organization
This guide is organized into four chapters and two appendixes:
Chapter 1, “Introduction”, outlines the main performance and safety
features of the Sun Tie XR. Reading this chapter will give you a clear
understanding of the inverters capabilities.
Chapter 2, “Installation”, provides information about planning for and
performing a Sun Tie XR installation.
Chapter 3, “Operation”, provides procedures for starting up the inverter
and operating the unit. It explains how to read the front panel display to
monitor the Sun Tie XR’s operation.
Chapter 4, “Troubleshooting”, for authorized service personnel only,
explains how to identify and solve problems that can occur with the
Sun Tie XR.
Appendix A, “Specifications”, provides the electrical, mechanical and
physical specifications of the Sun Tie XR.
Appendix B, “Warranty and Product Information”, contains the product’s
warranty. The appendix also explains how to return a product for service,
and to prepare for a call to Xantrex Customer Service.
Conventions Used
To reduce the risk of electrical shock and to ensure the safe installation
and operation of this product, the following safety symbols have been
placed throughout this manual to indicate dangerous conditions and
important safety instructions.
WARNING
Warnings identify conditions that could result in personal
injury or loss of life.
CAUTION
Cautions identify conditions or practices that could result in
damage to the Sun Tie XR or to other equipment.
About This Guide
975-0053-01-01 iii
Related Information
You can find more information about Xantrex Technology Inc. and its
products and services at www.xantrex.com
Note: Notes describe additional information which may add to your
understanding of how to install or use the Sun Tie XR.
iv 975-0053-01-01
1
Introduction
About the Sun Tie XR- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–2
Standard Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1–3
Accessories - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1–3
2
Installation
Installation Planning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2
Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–2
Tools required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–2
Hardware and materials required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–2
Locating the Sun Tie XR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–3
Routing the wires - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–3
Planning AC Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–4
Recommended wire sizes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–4
AC circuit breaker requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–5
Planning DC Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–5
Grounding Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–6
PV Array Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–7
Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–9
Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–9
Mounting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–9
Connecting DC Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–15
Connecting AC Wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–16
Grounding the System - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–18
Connecting Inverters in Parallel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–21
Installing the Optional Remote Monitor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–22
3
Operation
Startup Procedure- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–2
Required Equipment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–2
Checking the PV Array DC Voltage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–2
Checking the AC Utility Voltage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–3
Starting up the Sun Tie XR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–4
Monitoring the Front Panel Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–5
Reading the Front Panel Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–6
Status Indicator Lights - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–7
Reassembling the Sun Tie XR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–8
Contents
Contents
vi 975-0053-01-01
Factors Affecting Sun Tie XR Performance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–10
PV Array Factors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–10
Other Factors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–11
4
Troubleshooting
Troubleshooting the Sun Tie XR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–2
Viewing the Status LEDs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–2
Troubleshooting Reference Table - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–5
A
Specifications
Electrical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–2
Mechanical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–3
Standard Features and Options - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–4
Efficiency Curve - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–5
Temperature Derating Curve- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–6
B
Warranty and Product Information
Limited Warranty - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–2
Return Material Authorization Policy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–5
Return Procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–5
Information About Your System - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–6
Important Safety Instructions
For safe installation and operation:
All electrical work must be done in accordance with local and national electrical
codes.
Before installing or using this device, read all instructions and cautionary markings
located in the manual, on the Sun Tie XR and on the PV array.
WARNING: SAVE THESE INSTRUCTIONS
This manual contains important safety instructions that should
be followed during the installation and maintenance of this
product. Specific safety instructions for installation, operation,
and troubleshooting are in their respective sections. Read and
keep this manual for future reference.
DANGER: SHOCK HAZARD
Do not remove the upper cover. Removing the upper cover should
be performed only by authorized service personnel. If you suspect
your unit is not functioning correctly, call Xantrex.
Important Safety Instructions
viii 975-0053-01-01
Do not expose this unit to rain, snow or liquids of any type without
the Rain Shield installed. The Rain Shield does not, however, make
the Sun Tie XR waterproof.
To reduce the chance of short circuits when installing or working with
the inverter or the PV array, use insulated tools.
Remove all jewelry such as rings, bracelets, wristwatches and
necklaces prior to installing this system. This will greatly reduce the
chance of accidental exposure to live circuits.
The Sun Tie XR contains more than one live circuit (the PV array and
the AC line). Power may be present at more than one source even
when the circuit breakers are off.
This product contains no user-serviceable parts. Return the unit to
Xantrex for maintenance.
Wiring to the utility should only be done after receiving prior
approval from the utility company and performed only by a qualified
electrician.
Completely cover the surface of all PV arrays with an opaque (dark)
material before wiring them. PV arrays produce electrical energy
when exposed to light and could create a hazardous condition.
Introduction
Chapter 1, “Introduction”, describes the standard features and
accessories for the Sun Tie XR.
Introduction
1–2 975-0053-01-01
About the Sun Tie XR
The Xantrex Sun Tie XR grid-connect solar inverter is designed to
convert a home or business into a “green” power generating station. The
Sun Tie XR converts solar electric (photovoltaic, or PV) power into
utility-grade electricity that can be used by the home or sold to the power
company. Installing the Sun Tie XR consists of mounting it to the wall
and connecting a DC source (a PV array) and the AC output to the utility.
See Figure 1-1 for a simple diagram of a typical installation. In order to
operate, the Sun Tie XR must have grid power available and connected. It
will not provide backup power.
Figure 1-1
Basic System Overview
Note:
Figure 1-1 is a one-line drawing intended as a system overview
only. System grounding and other electrical details are not included.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Sun Tie
Solar-harvested
AC power to grid
AC utility meter
Main utility
electrical panel
AC output
voltage
DC input voltage
Sun Tie XR
PV array
About the Sun Tie XR
975-0053-01-01 13
Standard Features
All-in-one design All necessary DC input and AC output connections, disconnects and
circuit breakers are housed within the Sun Tie XR’s easily installed,
compact enclosure. A built-in LCD display panel provides easy-to-read
system status and daily cumulative energy production information. Two
status LEDs inside the unit also provide operating and troubleshooting
information.
Uses most types of
PV technology
The Sun Tie XR is designed to take advantage of most types of solar
electric technologies. The inverter allows up to 120 VDC open circuit PV
modules to be used, so it will work with both crystalline and thin film PV
modules.
Sun Sweep™
Maximum Power
Point Tracking
(MPPT)
Sun Sweep
TM
is Xantrex’s proprietary Maximum Power Point Tracking
technology that allows the Sun Tie XR to harvest the maximum amount
of energy from your solar array. No matter what PV system you choose
single crystalline, polycrystalline or thin film—SunSweep
TM
learns your
array’s specific characteristics, maximizing its output all day, all season,
year after year.
High efficiency The high-frequency, solid-state design of the Sun Tie XR inverter is
extremely efficient. Above 500 watts, the inversion process is 90%
efficient (or greater) with a peak efficiency of 91%.
Expandable Sun Tie XR inverters may be connected in a parallel configuration for
increasing net metering capacity. The modular expandability of the
Sun Tie XR Series allows for system growth.
Meets standards and
requirements
The Sun Tie XR has complete on-board islanding protection and meets
U.S. and Canadian safety operating standards and code requirements.
Accessories
STRM–Sun Tie XR Remote Monitor, for remote display of system
status, energy production, troubleshooting log, and resetting Wh.
STRS–Sun Tie XR Rain Shield, required for outdoor installation.
14 975-0053-01-01
Installation
Chapter 2, “Installation” provides information about planning for
and installing the Sun Tie XR. It contains information to help you
plan wire routes, AC and DC connections, and find a suitable
location for installation. It also discusses requirements for
grounding the Sun Tie XR and your PV array.
This chapter then provides procedures to install the Sun Tie XR,
including mounting, making DC and AC connections, and
grounding the inverter and the PV array.
Installation
22 975-0053-01-01
Installation Planning
Overview
Before you begin to install the Sun Tie XR you need to consider the
following:
tools required
hardware and materials required
mounting location
routes for AC and DC wiring
AC and DC connection wire size requirements
grounding requirements
PV array requirements
Tools required
Hardware and materials required
wood screws and washers (supplied)
metal conduit and appropriate fittings
anchors for screws (material dependent)
Phillips screwdrivers level
slot-head screwdrivers wire strippers
open-end wrenches torque wrench
socket wrench and fittings electrical tape
3/32" hex bit
pencil
multimeter utility knife
frequency counter (optional)
Installation Planning
975-0053-01-01 23
Locating the Sun Tie XR
The Sun Tie XR should be installed in locations that meet the following
requirements:
Routing the wires
Typical
configurations
Determine all wire routes to and from the Sun Tie XR. Typical routing
configurations include:
AC wiring from the Sun Tie XR to the main service panel
DC input wiring from the PV array to the Sun Tie XR
DC ground from the PV array to an external ground rod
Vertical The UL listing for the Sun Tie XR requires it
to be mounted vertically.
Dry When the Sun Tie is mounted outdoors, attach
the optional Rain Shield (STRS) to prevent
water entering the unit.
Temperature The unit meets specifications from 32 to
113 °F (0 to 45 °C) but will operate within the
temperature extremes of most climates—from
-38 to 113 °F (-39 to 45 °C). At extreme cold
temperatures the LCD display may not
function normally and it is recommended that
an indoor-mounted Remote Monitor be used.
At temperatures above 45 °C, the unit begins
derating power. See “Temperature Derating
Curve” on page A–6.
Ground clearance The Sun Tie requires at least 36 inches (100
cm) of clearance between the bottom of the
unit and the ground.
Dust free Dust can be drawn inside and accumulate
within the unit, interfering with wiring
connections and ventilation.
WARNING: SHOCK HAZARD
Do not install the Sun Tie XR unit outdoors without the Rain
Shield. Water entering the unit could cause a dangerous
condition and cause the unit to fail. Failure due to improper
installation will void the warranty.
Installation
24 975-0053-01-01
All wiring and installation methods should conform to applicable
electrical and building codes.
Conduit holes Pre-plan the wire and conduit runs. Knockouts for conduit holes are
located on the bottom of the unit. See Figure 2-9.
Acceptable wire
sizes
The DC terminal blocks in the Sun Tie XR accept up to a #6 AWG wire.
The AC circuit disconnects accept cable sizes up to #6 AWG.
For maximum safety, run AC and DC wires/cables in separate conduits.
Planning AC Connections
AC connections include all the wires and connectors between the
Sun Tie XR AC output breakers and the main utility electrical panel.
Figure 2-14 and Figure 2-15 show simplified diagrams of the entire
installation.
Recommended wire sizes
The AC output breakers accept wire sizes from #6–14 AWG. Refer to
Table 2-1 for minimum recommended wire size. The values in Table 2-1
are the minimum recommended wire sizes in conduit. Installing a large
number of wires in conduit or enclosed locations may require larger wire
sizes. Consult your local/national electrical code for more information.
WARNING: SHOCK HAZARD
Check for existing electrical or plumbing prior to drilling holes
in the walls.
Table 2-1 Recommended minimum AC wire sizes
Inverter model
AC amps
output per leg
NEC amps per leg
(amps x 125%)
Minimum wire size for specified distance
0–50 ft
one way
50–100 ft
one way
100–200 ft
one way
STXR1500 6.3 7.9 14 AWG 10 AWG 8 AWG
STXR2500 10.4 13.0 12 AWG 8 AWG 6 AWG
Note:
The six-circuit combiner board is rated for 100 amps (I
mp
) of
maximum real current. Although the 20 amp fuses will theoretically
allow 120 amps to be applied, always design for a maximum of 100
amps maximum current. With appropriate fuse deratings, per NEC code,
the maximum allowed current is 16 amps for any of the six circuits.
Installation Planning
975-0053-01-01 25
AC circuit breaker requirements
The main service panel must dedicate a 15 amp minimum, double pole
breaker (120/240 volts AC) to operate the Sun Tie XR.
Planning DC Connections
DC connections include all the wires and connectors between your PV
array and the Sun Tie XR’s combiner board. Figure 2-1 and Figure 2-2
show the combiner board and connection points. Figure 2-14 and Figure
2-15 show simplified diagrams of the entire installation.
Wire Sizes The DC connections are made on the combiner board inside the
Sun Tie XR. The combiner board accepts wire sizes from #6–14 AWG.
Refer to Table 2-2 for minimum recommended wire sizes.
Exceptions The values in Table 2-2 are the minimum recommended wire sizes.
Installing a large number of wires in conduit or enclosed locations may
require larger wire sizes. Consult your local or national electrical code for
more information.
NEC Restrictions The National Electrical Code (NEC) places restrictions on minimum DC
wire bending radius. A #6 AWG wire is the largest that may be used on
the Sun Tie XR when connecting to the individual fused circuits of the
combiner board.
Table 2-2 Recommended minimum DC wire sizes
DC amps (I
mp
)
(from PV array)
NEC amps
(amps x 156%)
Minimum wire size for specified distance
0–25 ft
one way
25–50 ft
one way
50–100 ft
one way
1.0 1.6 14 AWG 14 AWG 14 AWG
3.0 4.7 14 AWG 12 AWG 10 AWG
5.0 7.8 12 AWG 10 AWG 6 AW G
7.0 10.9 12 AWG 8 AWG 6 AWG
9.0 14.0 10 AWG 8 AWG Not Recommended
11.0 17.2 10 AWG 6 AWG Not Recommended
Note:
For an installation requiring a two-wire run (positive and
negative), the PV array wires can bypass the individual fused combiner
board terminals and connect directly to the input terminals (through an
externally mounted DC fused combiner box) by using the positive and
negative bypass terminals on the combiner board. Refer to Figure 2-2
and Table 2-2 for connection and wire sizes.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72

Xantrex Technology Telescope STXR1500 User manual