SERVICE MANUAL
MIDEA AIRCONDITIONER
ASIA PACIFIC OCEAN MARKET
SPLIT WALL-MOUNTED TYPE
LUNA ON-OFF SERIES
CONTENTS
1. Precaution .................................................................................................................................................... 1
1.1 Safety Precaution .......................................................................................................................... 1
1.2 Warning ......................................................................................................................................... 1
2. Function ........................................................................................................................................................ 6
3. Dimension .................................................................................................................................................... 9
3.1 Indoor Units ................................................................................................................................... 9
3.2 Outdoor Units .............................................................................................................................. 12
4. Refrigerant Cycle Diagram ....................................................................................................................... 14
5. Wiring Diagram .......................................................................................................................................... 16
5.1 Indoor Units ................................................................................................................................. 16
5.2 Outdoor Units .............................................................................................................................. 21
6. Installation details ...................................................................................................................................... 29
6.1 Wrench torque sheet for installation ........................................................................................... 29
6.2 Connecting the cables ................................................................................................................ 29
6.3 Pipe length and the elevation ..................................................................................................... 30
6.4 Installation for the first time ......................................................................................................... 31
6.5 Adding the refrigerant after running the system for many years ................................................ 34
6.6 Re-installation while the indoor unit need to be repaired ........................................................... 35
6.7 Re-installation while the outdoor unit need to be repaired ......................................................... 37
7. Operation characteristics ......................................................................................................................... 40
8. Electronic function .................................................................................................................................... 41
8.1 Abbreviation ................................................................................................................................ 41
8.2 Display function ........................................................................................................................... 41
8.3 Main Protection ........................................................................................................................... 42
8.4 Operation Modes and Functions ................................................................................................. 43
9. Troubleshooting ......................................................................................................................................... 52
9.1 Indoor unit error display .............................................................................................................. 52
9.2 Diagnosis and Solution ............................................................................................................... 54
1
1. Precaution
1.1 Safety Precaution
To prevent injury to the user or other people and property damage, the following
instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage.
Before service unit, be sure to read this service manual at first.
1.2 Warning
Installation
Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated
circuit.
There is risk of fire or electric shock.
For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized
service center.
Do not disassemble or repair the product, there is risk of fire or electric shock.
Always ground the product.
There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
There is risk of fire of electric shock.
Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fore or electric shock.
Use the correctly rated breaker of fuse.
There is risk of fire or electric shock.
Do not modify or extend the power cable.
There is risk of fire or electric shock.
Do not install, remove, or reinstall the unit by yourself(customer).
There is risk of fire, electric shock, explosion, or injury.
Be caution when unpacking and installing the product.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the
2
condenser and evaporator.
For installation, always contact the dealer or an Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
Do not install the product on a defective installation stand.
It may cause injury, accident, or damage to the product.
Be sure the installation area does not deteriorate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure,
and personal injury.
Do not let the air conditioner run for a long time when the humidity is very high and a
door or a window is left open.
Moisture may condense and wet or damage furniture.
Take care to ensure that power cable could not be pulled out or damaged during
operation.
There is risk of fire or electric shock.
Do not place anything on the power cable.
There is risk of fire or electric shock.
Do not plug or unplug the power supply plug during operation.
There is risk of fire or electric shock.
Do not touch (operation) the product with wet hands.
There is risk of fire or electric shock.
Do not place a heater or other appliance near the power cable.
There is risk of fire and electric shock.
Do not allow water to run into electric parts.
It may cause fire, failure of the product, or electric shock.
Do not store or use flammable gas or combustible near the product.
There is risk of fire or failure of product.
Do not use the product in a tightly closed space for a long time.
Oxygen deficiency could occur.
When flammable gas leaks, turn off the gas and open a window for ventilation before
turn the product on.
Do not use the telephone or turn switches on or off.
3
There is risk of explosion or fire.
If strange sounds, or small or smoke comes from product. Turn the breaker off or
disconnect the power supply cable.
There is risk of electric shock or fire.
Stop operation and close the window in storm or hurricane. If possible, remove the
product from the window before the hurricane arrives.
There is risk of property damage, failure of product, or electric shock.
Do not open the inlet grill of the product during operation. (Do not touch the electrostatic
filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
When the product is soaked (flooded or submerged), contact an Authorized service
center.
There is risk of fire or electric shock.
Be caution that water could not enter the product.
There is risk of fire, electric shock, or product damage.
Ventilate the product from time to time when operating it together with a stove, etc.
There is risk of fire or electric shock.
Turn the main power off when cleaning or maintaining the product.
There is risk of electric shock.
When the product is not be used for a long time, disconnect the power supply plug or
turn off the breaker.
There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
This could result in personal injury and product damage.
CAUTION
Always check for gas (refrigerant) leakage after installation or repair of product.
Low refrigerant levels may cause failure of product.
Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water leakage.
Keep level even when installing the product.
4
It can avoid vibration of water leakage.
Do not install the product where the noise or hot air from the outdoor unit could damage
the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins,
could cause product malfunction or inefficient operation.
Operational
Do not expose the skin directly to cool air for long periods of time. (Do not sit in the
draft).
This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc.
It is a consumer air conditioner, not a precision refrigerant system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very
sharp.
There is risk of personal injury.
Do not step on or put anything on the product. (outdoor units)
There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if
necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or
damage.
Do not insert hands or other object through air inlet or outlet while the product is
5
operated.
There are sharp and moving parts that could cause personal injury.
Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
Use a firm stool or ladder when cleaning or maintaining the product.
Be careful and avoid personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not
mix old and mew batteries or different types of batteries.
There is risk of fire or explosion.
Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.
They may burn of explode.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean
water. Do not use the remote of the batteries have leaked.
The chemical in batteries could cause burns or other health hazards
The designs, and information in this book are subject to change without notice for product improvement.
6
2. Function
Model Names of Indoor/Outdoor Units
Series Capacity Indoor units Outdoor units
On-Off
5k MS9A-05CR-QD0 MOK-05CP-QD0
7k MS9A-07CR-QB6 MOK2-07C-QB6
MS9A-07HR-QB6 MOK-07H-QB6
9k
MS9A-09CR-QB6 MOK6-09C-QB6
MS9A-09HR-QB6 MOK3-09H-QB6
MS9A-09CR-QB6(A) MOK8-09C-QB6
MS9A-09CR-QB6 MOK9-09C-QB6
MS9A-09CR-QC0 MOB1-09C-QC0
MS9A-09CR-QC4(A) MOB1-09C-QC4
12k
MS9A-12CR-QC4(A) MOB2-12C-QC4
MS9A-12CR-QB6 MOA1-12C-QB6
MS9A-12CR-QB6 MOA2-12C-QB6
MS9A-12HR-QB4 MOA1-12H-QB4
MS9A-12HR-QB6 MOB-12H-QB6
MS9A-12HR-QB6 MOA2-12H-QB6
18k
MS9A-18CR-QB6 MOB-18C-QB6
MS9A-18HR-QB6 MOB-18H-QB6
MS9A-18CR-PC4W(A) MOF-18C-QC4W
MS9A-18CR-QC2 MOF-18C-QC2
MS9A-18CR-QB8 MOB3-18C-QB8
MS9A-18CR-QC4(A) MOF2-18C-QC4
MS9A-18CR-QC0(A) MOC2-18C-QC0
7
MS9A-18CR-QC0(A) MOB1-18CP-QC0
MS9A-18CR-QC0 MOB2-18CP-QC0
21k MS9A-21HR-QB6W MOF4-21H-QB6W
22k MS9A-22CR-QC0 MOF-22C-QC0
MS9A-22CR-QB8 MOF-22C-QB8
24k MA9A-24HR-QB4W MOF-24H-QB4
8
Filter
Ionizer+(O)
Ionizer(O)
Silver Ico Filter(O)
Vitamin C Filter(O)
3M HAM Filter(O)
Bio Filter(O)
Golden Fin(O)
Killer of Formaldehyde
Compressor Crankcase Heater(O)
Self Clean(O)
Follow me(O)
8 degree heating(O)
Heat compensation(O)
Self-diag. function
H
ydrophilic aluminum fin
Anti-rust cabinet
Valve protection cover
PTC Heating Belt(O)
O: optional function
9
3. Dimension
3.1 Indoor Units
Model W H D
MS9A-05CR-QD0
710 250 190
MS9A-07CR-QB6
MS9A-07HR-QB6
MS9A-09CR-QB6
MS9A-09HR-QB6
MS9A-09CR-QB6(A)
790 265 198
MS9A-09CR-QC0
MS9A-09CR-QC4(A)
MS9A-12CR-QB6
MS9A-12HR-QB4
MS9A-12HR-QB6
MS9A-12CR-QC4(A)
920 292 223
MS9A-18CR-QC0
MS9A-18CR-QB6
MS9A-18HR-QB6
MS9A-18CR-PC4W(A)
998 240 322
MS9A-18CR-QC2
MS9A-18CR-QB8
MS9A-18CR-QC4(A)
MS9A-18CR-QC0(A)
MS9A-21HR-QB6W
MS9A-22CR-QC0
MS9A-22CR-QB8
10
LR
H
Model
R(mm)
H(mm)
Dimension of installation hole(mm)
MS9A-05CR-QD0
111.5 100 45
65
MS9A-07CR-QB6
MS9A-07HR-QB6
MS9A-09CR-QB6
MS9A-09HR-QB6
MS9A-09CR-QB6(A)
151 100 45
MS9A-09CR-QC0
MS9A-09CR-QC4(A)
MS9A-12CR-QB6
MS9A-12HR-QB4
MS9A-12HR-QB6
MS9A-18CR-QC2
118.5 100 45
MS9A-18CR-QB8
MS9A-18CR-QC4(A)
MS9A-18CR-QC0(A)
MS9A-22CR-QC0
MS9A-22CR-QB8
MA9A-24HR-QB4W
MA9A-24HR-QB4W
11
Model R(mm) L(mm) H(mm) Dimension of installation hole(mm)
MS9A-12CR-QC4(A)
186.5 150 45 65
MS9A-18CR-QC0
MS9A-18CR-QB6
MS9A-18HR-QB6
MS9A-18CR-PC4W(A)
120
100
45
H
L R
12
3.2 Outdoor Units
More than 30cm
More than 60cm
More than 70cm
More than 30cm
More than 60cm
(Service space
Fence or
obstacles
Model
W
D
H
W1
A
B
MOK-05CP-QD0
685 260 430 742 460 276
MOK2-07C-QB6
MOK-07H-QB6
MOK8-09C-QB6
MOK9-09C-QB6
MOK6-09C-QB6
MOK3-09H-QB6
MOA1-12C-QB6
700 240 540 757 458 250
MOA2-12C-QB6
MOA1-12H-QB4
MOA2-12H-QB6
MOB1-09C-QC0 780 250 540 843 549 276
MOB1-09C-QC4
13
MOB2-12C-QC4
MOB-12H-QB6
MOB-18C-QB6
MOB3-18C-QB8
MOB1-18CP-QC0
MOB2-18CP-QC0
MOB-18H-QB6
MOF-18C-QC4W
845 320 700 908 560 335
MOF-18C-QC2
MOF2-18C-QC4
MOF4-21H-QB6W
MOF-22C-QC0
MOF-22C-QB8
MOF-24H-QB4
MOC2-18C-QC0 760 285 590 823 530 290
14
4. Refrigerant Cycle Diagram
For cooling only models:
INDOOR OUTDOOR
LIQUID SIDE
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
CAPILIARY TUBE
15
For heat pump models:
INDOOR OUTDOOR
LIQUID SIDE
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
2-WAY VALVE
3-WAY VALVE
CHECK VALVE
(Heating Model only)
CAPILIARY TUBE
REVERSING VALVE
(Heating Model only)
COOLING
HEATING
ACCUMULATOR
16
5. Wiring Diagram
5.1 Indoor Units
MS9A-07CR-QB6, MS9A-09CR-QB6, MS9A-12CR-QB6
MS9A-07HR-QB6, MS9A-09HR-QB6, MS9A-12HR-QB4, MS9A-12HR-QB6, MS9A-18HR-QB6
17
MS9A-18CR-QB6
18
MS9A-18CR-PC4W(A)
MS9A-05CR-QD0, MS9A-09CR-QB6(A), MS9A-09CR-QB6, MS9A-09CR-QC0,
MS9A-09CR-QC4(A)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61

Midea MA9A-24HR-QB4W User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI