Posiflex CD-3604U/R Quick setup guide

Type
Quick setup guide
1
Package Contents
CD-3604U
2D image scanner
USB cable
Quick setup guide
CD-3604R
2D image scanner
RS-232 cable
Quick setup guide
Parts of the 2D Image Scanner
Default Settings
Scanning the following barcode can restore the engine to the factory defaults.
Before setting, please scan the Enter Setup barcode on P.3. If your CD-
3604U/R is planned to be installed into our Posiflex kiosk model, please scan
the barcode on the right side. After setting, please scan the Exit Setup barcode
on P.3.
Trigger Button1
Scan Window
w/ Object Detector
Mounting Screw Hole
Beeper Hole
CD-3604 (U/R)
2D Image Scanner
Quick Setup Guide
18091901010 Ver. A0
http://www.posiflex.com
Restore Kiosk Trigger Default
(For Kiosk Model)
$>:S010186.<
$
Restore All Factory Defaults
2
Scanner Maintenance
The scanner is designed for long-term trouble-free operation and rarely requires
any maintenance. Only an occasional cleaning of the scanner window is necessary
in order to remove dirt and fingerprints.
Wipe the scan window with a soft lint-free cloth and a non-abrasive cleaner to
avoid the scan window from being scratched and damaged. The scan window can
be cleaned while the scanner is running.
The standard interface cable is attached to the scanner with a 10-pin modular
connector. When the connector is properly seated, it is secured in the scanner by a
flexible retention tab. The cable is designed to be field replaceable. Replacement
cables can be obtained from your authorized distributor. To replace the cable, take
the following steps.
1. Make sure the power of both the host terminal and the scanner is powered off.
2. Disconnect the old scanner cable from the host terminal.
3. Press down the retention tab, and gently pull out the cable.
4. Insert the new interface cable into the bottom of the scanner until it clicks.
Then, plug the new cable into the host.
Troubleshooting
This section contains information about how to solve problems that you may
encounter when operating the scanner. If a trouble occurs, please refer to the
following diagnostic tips as a mean to solve the trouble. However, before referring
to the tips, make sure that the scanner is installed well. If the problem remains,
contact your dealer.
Problem
Diagnostic Tips
The scanner is on but cannot read
any barcode.
The scanner window is dirty. Clean the scanner
window as described in the Scanner
Maintenance section.
The presented barcode type is not enabled. Use
this guide to tell the scanner to accept that type
of barcode.
The host terminal has disabled the scanner.
Check the setup of host terminal.
The barcode type presented is not supported by
the scanner.
The scanner does not accept more
than two or three barcode labels.
Determine whether the required barcode types
are enabled or not.
A stray barcode is sitting somewhere in the
scanner field of view. Remove all barcode labels
from the scanner’s scan volume and try again.
3
Problem
Diagnostic Tips
The scanner cannot send the data to the POS
system. Make sure that the scanner is installed
well and your host POS system is ready to
receive data.
A barcode is read by the scanner
but not accepted by the POS
system.
The communication settings of the system port
and the scanner do not match. Adjust the settings
to make them match to each other.
The scanner is not installed well. Contact your
dealer for the proper installation. The software
running on the POS system does not support the
data format of the barcode label.
When a barcode stays close to the
scanner, the barcode cannot be read
automatically by the scanner.
Check whether or not you have enabled the
Manual Trigger mode. If you have enabled this
mode accidentally, please disable the Manual
Trigger mode by scanning the “Disable trigger”
barcode in the advanced user manual.
Programming Codes
Below are some suggestion you need to bear in mind while scanning labels:
1. The barcode labels shown in bold and black are default factory settings.
2. Please cover the unwanted codes for scanning the specific barcode required
for the programming to prevent confusion in code scanning.
3. Use the user manual downloaded from our global website for advanced
programming.
4. While scanning the setup barcode labels provided in the quick guide, you need
to pull the trigger to initiate the decoding process.
Programming Barcodes
Scanning the Enter Setup barcode can enable the engine to enter the setup
mode. Then you can scan a number of programming barcodes to configure
your engine. To exit the setup mode, scan the Exit Setup barcode or a non-
programming barcode, or reboot the engine.
Enter Setup
Exit Setup
4
Firmware Version
Scan the below barcode to retrieve the current firmware version.
USB/RS-232 Interface
There are four options for USB connection:
USB HID-KBW: In keyboard mode, place the mouse cursor on the notepad,
etc., and the data will be entered into the notepad after successful decoding.
USB HID POS: Use HID POS protocol to communicate.
USB Virtual COM: Enumerate into a virtual serial port. At this time, the PC
needs to use the serial port assistant to receive data.
RS-232 Interface: Rs232 interface is a common way to connect scanner and
host equipment (such as PC, POS and other equipment). When using the
RS232 interface, the scanner and the host device must match the
communication parameter configuration completely to ensure smooth
communication and correct content.
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
USB HID-KBW (default)
$>:S0F0116.<$
USB HID POS
$>: S0F0516.<$
5
USB Virtual COM
$>: S0F0216.<$
RS232
$>: S0F0016.<$
Trigger Mode
Manual Mode: Press the button to trigger the reading, and release the button
to end the reading. If the reading is successful or the reading time exceeds
the single reading time, the reading will end.
Automatic Scanning Mode: In the induction mode, you can activate the
scanner to work by pressing a button, sending a command, or auto-sensing.
Continuous Scanning Mode: Under continuous Scanning Modeafter a
period of time when a reading is successful, it will automatically start the
next reading. Start or end scanning until the button is pressed and released
(buttons and commands can be terminated and reopened)
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
Manual Mode (default)
(Command + Button)
$>: S03001A.<$
Automatic Mode
(Command+Button+Auto-sensing)
$>: S03011A.<$
6
Continuous Mode
(Button+Command)
$>: S03021A.<$
Illumination
A couple of illumination options are provided to improve the lighting conditions
during every image capture:
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
Off
$>:S0C0000.<$
Reading On (default)
$>:S0C0400.<$
Always On
$>:S0C0800.<$
Aiming
When scanning/capturing image, the engine projects an aiming pattern which
allows positioning the target barcode whining its field of view and thus makes
decoding easier.
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
7
Off
$>:S300000.<$
Reading On (Lit when reading, default)
$>:S301000.<$
Always On
$>:S302000.<$
Good Read Beep Frequency
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
Low
$>:SFFDA27.<$
Medium
$>:SFF4B27.<$
Loud (default)
$>:SFF2527.<$
Prompt Tone Duration
Before setting, please scan the Enter Setup barcode on P.3.
8
After setting, please scan the Exit Setup barcode on P.3.
40ms (Short)
$>:SFF1F28.<$
80ms (Middle) (default)
$>:SFF3E28.<$
120ms (Long)
$>:SFF5D28.<$
Good Read Tone Sound
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
Low
$>:S030018.<$
Medium
$>:S030118.<$
Loud
$>:S030218.<$
9
Enabling/Disabling of readable codes
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
Enable All Barcodes
$>:S010187.<$
Disable All Barcodes
$>:S010087.<$
Enable All 1D Codes
$>:S020287.<$
Disable All 1D Codes
$>:S020087.<$
Enable All 2D Codes
$>:S040487.<$
Disable All 2D Codes
$>:S040087.<$
10
Enable Code128/AIM128/EAN128/NL128 (default)
$>:S010188.<$
Disable Code128/AIM128/EAN128/NL128
$>:S010088.<$
Enable UPC/EAN/ISSN/ISBN (default)
$>:S010189.<$
Disable UPS/EAN/ISSN/ISBN
$>:S010089.<$
Enable Codabar
$>:S01018C.<$
Disable Codabar (default)
$>:S01008C.<$
Enable Code 39 (default)
$>:S01018A.<$
11
Disable Code 39
$>:S01008A.<$
Enable Code 32 (default)
$>:S0101AB.<$
Disable Code 32
$>:S0100AB.<$
Enable Code 93 (default)
$>:S01018D.<$
Disable Code 93
$>:S01008D.<$
Enable Code 11
$>:S01018F.<$
Disable Code 11 (default)
$>:S01008F.<$
12
Enable ITF-25/ITF-14/ITF-6/Deutsche12/Deutsche14 (default)
$>:S01018B.<$
Disable ITF-25/ITF-14/ITF-6/Deutsche12/Deutsche14
$>:S01008B.<$
Enable Industrial 25
$>:S010193.<$
Disable Industrial 25 (default)
$>:S010093.<$
Enable Matrix 25
$>:S01018E.<$
Disable Matrix 25 (default)
$>:S01008E.<$
Enable NEC 25/Japan Matrix 25
$>:S01019E.<$
13
Disable NEC 25/Japan Matrix 25 (default)
$>:S01009E.<$
Enable Standard 25
$>:S010192.<$
Disable Standard 25 (default)
$>:S010092.<$
Enable Data Logic 25
$>:S01019F.<$
Disable Data Logic 25 (default)
$>:S01009F.<$
Enable MSI-Plessey
$>:S010191.<$
Disable MSI-Plessey (default)
$>:S010091.<$
14
Enable Plessey
$>:S0101A0.<$
Disable Plessey (default)
$>:S0100A0.<$
Enable RSS-EXP/RSS_14/GS1 Data
$>:S010190.<$
Disable RSS-EXP/RSS_14/GS1 Data (default)
$>:S010090.<$
Enable Telepen
$>:S010194.<$
Disable Telepen (default)
$>:S010094.<$
Enable Pharma Code One-Track
$>:S0101A1.<$
15
Disable Pharma Code One-Track (default)
$>:S0100A1.<$
Enable Pharma Code Two-Track
$>:S0101A2.<$
Disable Pharma Code Two-Track (default)
$>:S0100A2.<$
Enable AZTEC
$>:S01019A.<$
Disable AZTEC (default)
$>:S01009A.<$
Enable CODABLOCK A
$>:S01019C.<$
Disable CODABLOCK A (default)
$>:S01009C.<$
16
Enable CODABLOCK F
$>:S01019D.<$
Disable CODABLOCK F (default)
$>:S01009D.<$
Enable Data Matrix (default)
$>:S010197.<$
Disable Data Matrix
$>:S010097.<$
Enable MaxiCode
$>:S010199.<$
Disable MaxiCode (default)
$>:S010099.<$
Enable PDF417 (default)
$>:S010195.<$
17
Disable PDF417
$>:S010095.<$
Enable Micro PDF
$>:S0101A3.<$
Disable Micro PDF (default)
$>:S0100A3.<$
Enable Micro QR
$>:S010198.<$
Disable Micro QR (default)
$>:S010098.<$
Enable Han Xin Code
$>:S01019B.<$
Disable Han Xin Code (default)
$>:S01009B.<$
18
Enable DOTCODE
$>:S0101AE.<$
Disable DOTCODE (default)
$>:S0100AE.<$
Allow ID Card Reading
$>:S0101AC.<$
Prohibit ID Card Reading (default)
$>:S0100AC.<$
Allow Passport Reading
$>:S0202AC.<$
Prohibit Passport Reading
$>:S0200AC.<$
Baud rate settings (Only for CD-3604R)
Baud rate is the number of bits of data transmitted per second. Set the baud rate to
match the host requirements.
Before setting, please scan the Enter Setup barcode on P.3.
After setting, please scan the Exit Setup barcode on P.3.
19
1200bps
$>:S0F0047.<$
2400bps
$>:S0F0147.<$
4800bps
$>:S0F0247.<$
9600bps (default)
$>:S0F0347.<$
19200bps
$>:S0F0547.<$
38400bps
$>:S0F0647.<$
57600bps
$>:S0F0747.<$
20
115200bps
$>:S0F0847.<$
Specifications
Item
Characteristics
Performance
Image Sensor
1280*800 CMOS
Illumination
White LED
Aiming
Red LED
Symbologies
2D
QR, Micro QR, PD417, Micro PDF,
Data Matrix, Aztex, Maxicode, Han
Xin, etc.
1D
Code 128, EAN-13, EAN-8, Code 39,
UPC-A, UPC-E, Codabar, Interleaved
2 of 5, ITF-6, ITF-14, ISBN, Code
93, UCC/EAN-128, GS1 Databar,
Matrix 2 of 5, Standard 2 of 5,
Plessey, MSI-Plessey, etc.
Resolution*
4mil
Typical Depth of Field*
EAN-13 (13mil): 40mm-360mm
PDF417 (6.67mil): 30mm-200mm
Data Matrix (10mil): 30mm-220mm
Code 39 (5mil): 40mm-180mm
QR Code (20mil): 40mm-330mm
Min. Symbol Contrast
25%
Scan Angle**
Roll: 360°, Pitch: ±50°, skew: ±50°
Field of View
Horizontal 49.6°, Vertical 37.2°
Electrical
Interface
RS-232, USB
*Test conditions: T=25°C Illumination=200lux using incandescent lamp.
**Test conditions: Scan Distance=(min. DOF + max. DOF)/2; T=25°C;
Illumination=200lux using incandescent lamp.
The product information and specifications are subject to change without
prior notice. To get the detailed information of the CD-3604U/R, please
check this model from Posiflex Global Website.
(http://www.posiflex.com/en-global/Download/download). Or download
the advanced manual for more detailed settings.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Posiflex CD-3604U/R Quick setup guide

Type
Quick setup guide

Ask a question and I''ll find the answer in the document