iRest SL-A17 Operation Instructions Manual

  • Hello! I am an AI chatbot trained to assist you with the iRest SL-A17 Operation Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
SAVE THESE INSTRUCTIONS
SL-A17 massage chair
Operation Instructions
02
First of all, thank you for purchasing Massage Chair . Before using the
unit, please read the instructions manual carefully before operating
this machine, and use it as reference when necessary.
Note: Our Company has the absolute right to alter the design, pictures,
and material color without prior notice. Design, pictures and material
color seen in this manual is solely for illustration purposes.
THE FIRST STEP TO HEALTH
IMPORTANT SAFETY INSTRUCTIONS
Do not use it when voltage does not meet with standard.
Do not soak the control into water to avoid malfunction.
Do not drop or push anything into any slot or hole of the machine.
Do not use it in wet condition such as bathroom, swimming pool, or spa.
Do not be close to a heater.
Do not use it when its outer cover is broken.
Do not pull the plug forcefully or hold the plug with wet hands. In this case the cover
should be replaced in time.
A 3 pin socket is required .The grounding wire must be safely connected to the ground.
Please do check the power button is off before connecting the plug to the socket.
Please do check the power is switched off after using and pull the plug out of the socket
with the correct way.
Do not forget to pull the plug out of the socket whenever there is a power cut to avoid
unforeseeable accident.
If anything abnormal occurs, please switch the machine off immediately and pull the
plug out of the socket, then consult the local dealer or our service center.
Do not stab the surface of the chair with anything sharp like needles, otherwise it may
cause damage or deflation to the air bags.
This machine may become partially hot after running for a long time, users who are
sensitive to heat are kindly suggested not to use it continuously for too long.
Please stop immediately and consult your doctor if you feel strange pain when using
the machine. Children under 12 or people mentally unbalanced are not allowed to use.
Women pregnant or during their periods are not allowed.
People suffering from malignant tum or are not allowed.
People severely wounded are not allowed.
People with heart trouble are not allowed.
People with fragile bones are not allowed.
People wearing a heart pacemaker are not allowed.
Do prevent children from playing under the back or the calf support ; In case of damage to
the chair, do not sit on the calf support or the armrest.
01
SAVE THESE INSTRUCTIONS
0403
CHECK BEFORE USING
1.Ensure there is sufficient space to place the massage chair.
2.Ensure no obstructions or gadgets place around the massage chair.
3.Ensure that the cable is not stuck under the massage chair.
INSTALLATION AND USE OF CONTROLLER
Install the controller shelf on
the massage chair
The controller can be controlled
and rotated 360 degrees
The controller can rotate 180
degrees from head to foot
Switch on Power
1.Insert the plug in the socket.
2.On the switch behind the left handrail.
To Massage
Use the controller to choose the different massage functions.
To Switch Off
1.Turn off the power on the controller.
2.Switch off the switch behind the left handrail.
3.Pull the plug out from the socket.
OPERATING INSTRUCTION
Switch
05
05
0605
The back covering
Ventilator
Power Switch
Fuse Box
Power Cord& Plug
Moveable Caster Rollers
Controller
STRUCTURAL ILLUSTRATION
Detachable Pillow Pad
Detachable Back Cover
Control box
Armrest
Detachable seat cushion
Footrest
Power
BUTTON EXPLANATION
1.To start or stop massage of the upper body. The button will not work
when the massage device is at its position of recovery.
2.When you start the massage functions of the upper body, the
massage device begins to move downward to suit the position of your
shoulder.
For specific body size, you can press the upward or downward
button to adjust the massage hands slightly within a small range to
suit your shoulder. Five positioning available for the shoulder area
with respective indicators turning on or off.
Adjust position on the shoulder first
Digital display
Input
Output
0807
Button show description
Regulate their shoulder positions according to people's size
Regulate their shoulder positions according to people's size
Button show description
Adopt the various tactics to carry on automatic massage to
different position of the upper part of the body, the massage
position covers the whole upper part of the body.
To carrying on automatic massage around the
neck shoulder mainly
Carry on automatic massage around in carrying
the waist mainly.
Pushing the switch in the automatic mode will start the automatic mode
Auto mode
BUTTON EXPLANATION
12345
Manual mode
BUTTON EXPLANATION
Button show description
Width Middle Narrow
Press the manual mode button and it will automatically change to manual mode.
Knead, loosen your tense muscles
Flap, penetrates deep into the body
Knead & Flap, Relaxing the muscles
Shiatsu Technique
To relieve tired, soothing, sore and stiff muscles
Tapping, to increase blood circulation and skin elasticity
To select full-range, partial or fixed massage
This button to move the device upward to suit precise
massage points, invalid under auto mode.
massage
This button to move the massage device downward to suit
precise massage points, invalid under auto mode.
The massage tactics tempo can be chosen by 5 speed
Massage treatment of flapping, shiatsu, or knocking has been chosen,
press this button to adjust the width of the massage hands, three options
1.Pull the tie-in out of the whole of
the cushion.
2.Fix the air pipe to the
corresponding tie-in.
3.Put the joint of air pipe and tie-in
under the cushion board, lay down
the cushion and it can be used after
well connection.
1009
Lower body airbag
BUTTON EXPLANATION
Button show description
Button show description
Adjust the chair back
Air massage of the lower body
Unified air massage modes up to four options
Different intensities of air massage
Joint traction (knee-calf stretch).
Press the rising button to rise, the footrest will rise
Press the reclining button to drop, the footrest will drop
Press the rising button to rise, the footrest will drop
and backrest will rise
Press the reclining button to drop, the footrest will rise
and backrest will drop
ATTACHING OR DETACHING THE PILLOW PAD AND BACK CUSHION
The pillow pad and back cushion (recommended) reduces the kneading
intensity of your neck and shoulder, but you can decide to put it on or not
according to your personal need.
Zipper connects the back cover.
Sticker connects the pillow
pad and back cover.
In case of danger, do not remove the back cover.
Firstly, settle the chair well(Please note that enough space must be left for the extension
of massage chair: at least 80MM from the caster to the back, and 30MM from the front
base). The space is for the extension of the backrest and calf support.
Connect the coin-operator with the massage chair by the data cable, Please ensure they
are stably connected. (Please see the drawing A).
Secondly, Open the front door of the operator (maybe back door if other models),there is
a electro circuit board with two four-button switches. Please operate according to the
setting instructions.(Please see the drawing B).
OPERATION SEQUENCE
4321
ON
ON
4321
Setting board
Notice! Making revises must be in power-off condition!
SETTING INSTRUCTIONS OF COIN-OPERATOR
Revising setting should be done in power-off condition.
It is prohibited to make revises in power-on condition.
The setting of coin operator includes two settings of four-button switches, please see the
below
1 The upper one is working time switch which adjusts the working time per started.
The below one is starting switch which presets the minimum coins requested to start
the massage chair.
drawing I
Setting board
Starting switch
Working time switch
4321
ON
ON
4321
Drawing A
Drawing B
Drawing I
1211
1,How to set the quantity of coin for starting.
This device includes four mini-buttons. Changing the up-down
position of the four buttons presets the minimum quantity of coin to
start the coin-operator. There are 16 choices optional; they are 1
piece, 2 pieces and so on, up to 16 pieces. User may choose any one
for usage. Please contrapose form I, ( 0 means the mini button be up;
1means down)
2, How to set the working time.
This device includes four mini-buttons. Changing the up-down
position of the four buttons presets the minimum working time per
time after it is started. There are totally 16 different period of time
optional, they are 1 2 3 4 5 6 7 8 9 10 12 14 16
18 20 25 minutes. User can choose any one according to
individual demand. If the operator be on working state, more coins
putted in will be calculated into cumulate working time. Please
contrapose form II, ( 0 means the button be up; 1means down)
Please Note: that the maximum cumulate working time is 99
minutes.
The position of four starting buttons
Starting coins
1pc
2pcs
3
4
5
6
7
8
9
10
11
12
13
14
15
16
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1minute
2minutes
3minutes
4minutes
5minutes
6minutes
7minutes
8minutes
9minutes
10minutes
12minutes
14minutes
16minutes
18minutes
20minutes
25minutes
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
Form I Form II
Mini working
time
The position of four working
time buttons
Remarks: 0 means the mini button be up; 1means down.
No. 1 No. 2 No. 3 No.4 No. 1 No. 2 No. 3 No.4
SETTING INSTRUCTIONS OF COIN-OPERATOR SETTING INSTRUCTIONS OF COIN-OPERATOR
1413
For example: To preset 3 pieces coins for starting with 8 minutes as
minimum working time; The setting of staring switches should be like
form III, and working time setting be like form IV. Actual states please
contrapose drawing II.
4
0
32
0
1
03
1
4321
08
111
Setting board
Starting switch
Working time switch
4321
ON
ON
4321
Form III
Form IV
Drawing II
The position of four starting buttons Starting coins
Mini working
time
The position of four starting buttons
THE OPERATOR IS MOUNTED A COIN-COUNTER,WHICH COUNTS THE COIN
QUANTITY THAT PUTTED IN FOR USER REF. AND THE COUNTER CAN NOT
BE RECOVERED TO ZERO.
SETTING INSTRUCTIONS OF COIN-OPERATOR
HOW TO MOVE THE MASSAGE CHAIR
After having confirmed all the wires are away
from the ground, turn the back rearward to a
proper angle with the gravity center of the chair
falls onto the casters. Pull the massage chair
forward or backward as you wish, and then turn
the back to its normal angle.
FLOOR PROTECTION
Lasting pressure of the
massage chair on the
floor may leave scars to
the latter. To avoid
such scars, just put a
piece of carpet under
the chair.
Do not move the chair with its casters on wooden floor, rough ground or
in narrow space, otherwise two persons are needed to lift it together.
1615
Before Use:
1. Please read the instructions carefully before operation, and assemble the
massage chair correctly according to the step of manual instructions.
2. Please do check the power button has been switched off before connecting the
plug to a socket outlet.
Familiarising Process:
1.Do not use this chair for too long for the first time.
2.If too much pressure from the massage heads makes you uncomfortable, put a
piece of thick blanket on your back to reduce the pressure.
To Prolong The Life Span of the Machine:
The rated working time of this machine is 15 minutes. To prolong the life span of
the machine, stop for 20 minutes before the next use.
After use:
Switch off power and pull the plug out of the socket every time after use.
Storage and Working Conditions:
1. Do not expose it to sunlight directly.
2. Do not put it too close to a heater.
3. Do not use this machine in wet areas such as bathroom, swimming pool or spa.
4. This machine is not for outdoor use.
5. Do not use it where there is too much dust, oil, smoke or caustic gas.
Protection of the Massage Chair:
1.Do not put your hands between the massage heads while they are working.
2.Do not drop or push anything into any slot or hole of the machine.
3.In case of damage to the machine, do not jump on the back or the seat cushion.
Repair:
Do not try to assemble or disassemble the chair yourself if there is any damage
to the wire or the plug. In this case please contact the nearest outlet or service
center for maintenance or repair.
Cleaning:
Do not clean the massage chair with thinners such as ethanol or gasoline, but
wet towels are allowed to clean its surface.
Others:
1.If you need to move the massage chair between places with large temperature
variance, please ensure that the machine has been stopped working for at least
one hour before moving.
2.Please switch the machine off and pull the plug out of the socket immediately
if you feel anything abnormal while it is working, then consult the local service
centre for maintenance or repair.
3.Please stop the machine and consult your doctor if you feel pain.
MAINTENANCE & PRECAUTIONS
18
17
TROUBLESHOOTING GUIDE
The machine does not
work when it is connect-
ed to power.
Its sound suddenly
while the machine
is working.
The machine
stops suddenly
It has not been switched
on.
Connection failure be-
tween the plug and the
socket.
The machine has been
working for too long.
It has been working conti-
nuously for so long that
it automatically stops for
self-protection.
Cut off power and pause
for half an hour.
PROBLEM POSSIBLE CAUSE(S) SOLUTION
The machine is in normal
working state if the noise
is slight.
Cut off power and pause
for half an hour.
Cut off power and pause
for half an hour.
NOTE: if you fail to solve the problem after making the above-mentioned
checks, please send the machine to our service center for maintenance.
Switch it on.
Check the socket and en-
sure the plug has been
closely connected to the
socket.
Some clattering noise
is heard while the ma-
chine is working.
There is nothing need
to be done.
It has been working conti-
nuously for a rated period
of time.
POWER
RATED WORKING TIME
SAFETY DESIGN
VOLTAGE
FREQUENCE
MASSAGE CHAIR 180W
15 MINUTES
DESCRIPTION
MODEL SL-A17
110-120V~
220-240V~
TECHNICAL SPECIFICATIONS
APPEARANCE TT T
60Hz
50Hz/60Hz
Class I
/