MQ Multiquip J36E2 Operating instructions

Type
Operating instructions
OPERATION AND PARTS MANUAL
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
To nd the latest revision of this
publication, visit our website at:
www.multiquip.com
MODEL J36E2
WALK-BEHIND TROWEL
(2 HP ELECTRIC MOTOR)
S/N LE0118039 AND BELOW
Revision #2 (01/31/18)
PN: 23814
NOTICE
Support is no longer available for J36E2 operation at
115 volts. If your J36E2 trowel is configured for 115-volt
operation (S/N LE0118039 and below), it will need to be
rewired for 230-volt operation. Please see the attached
Safety Warning and Service Bulletin for details.
NOTICE
For current operation and/or parts information for the
J36E2 Walk-Behind Trowel, go to www.multiquip.com
and refer to the operation and parts manuals for the
J36E2 (S/N LE0118040 and above).
SAFETY WARNING
Date: 10/16/19
To: Electric Walk-Behind Trowel Owners
From: Multiquip Product Department
Subject: Only Operating J36E2/J42E on 230 VAC
Dear Multiquip Customer,
Our records indicate you purchased an MQ Whiteman power trowel equipped with a 2.0 hp electric motor
rated for 115-volt or 230-volt operation. This type of trowel is identified by the following model numbers: J42E
and J36E2.
These trowels were originally manufactured to operate at 115 volts with the optional capacity to operate at
230 volts.
One of the safety features of the trowel is the Operator Presence ON/OFF Lever Switch. When the lever is
released, power to the electric motor will be interrupted.
We have learned that the electric switch that enables power interruption is underrated for the electrical current
required for safe operation at 115 volts. In rare circumstances, electrical contacts in the switch may fail, preventing
the Operator Presence ON/OFF Lever Switch from operating as intended. Failure of the switch could result in
a runaway trowel and SERIOUS INJURY and/or property damage.
Multiquip is unaware of any reports of electric switch failure resulting in the failure of the Operator Presence
ON/OFF Lever Switch. However, we believe it is necessary to bring this to your attention as a safety precaution.
If you own any of these models listed above, use the trowel only in its 230-volt configuration and for 230-volt
operation only. DO NOT CONTINUE OPERATING THE TROWEL USING 115-VOLT POWER. Conversion
(rewiring) to 230-volt operation should be done only by a qualified technician or a Multiquip service center.
Is a replacement micro-switch available that permits operation using 115-volt power?
No. At this time a replacement switch is not available.
What if I have sold the trowel?
Please forward this Notice or a color copy of this Notice to, or provide us with contact information for, the new
owner or retail purchaser.
How do I rewire the motor to 230 volts?
The conversion should only be done by a qualified technician or equipment service center. If you need
assistance locating a service center please call the Multiquip warranty department at 800-421-1244 or email
us at techsupport@multiquip.com.
Is this campaign covered under warranty?
Yes. If the original product warranty period has expired, Multiquip will extend the new product limited warranty
to cover conversion costs in accordance with this campaign. See Warranty Information below.
WARRANTY INFORMATION
File your claim online via E-Warranty at http://service.multiquip.com/warranty-support.html or contact our
warranty department for assistance at 800-421-1244.
Campaign: Reference No. TR20190823
Labor Allowance: 1.0 hour total flat rate for rewire of unit from 115 VAC to 230 VAC.
Your prompt attention to this matter is appreciated. If you have questions, please contact the Multiquip Technical
Support Department at 800-478-1244 or techsupport@multiquip.com.
We appreciate your business and apologize for any inconvenience this creates. Our goal remains to supply
you with top-quality equipment and superior product support.
2
Product Group: Date Issued: Expiration Date: Service Bulletin No.
Bulletin Type Models/Series Affected:
_____ Mandatory
_____ Information Only
_____ Recommended Change
Details
Service Bulletin
Electric Walk-Behind Trowel 230V Wiring Update
ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 1
Trowels
X
J36E2
S/N LE0118039 AND BELOW
J42E
S/N ZD0158011 AND BELOW
TR20190823
Problem:
We have learned that the electric switch that enables power interruption is underrated for the electrical current
required for safe operation at 115 volts. In rare circumstances, electrical contacts in the switch may fail, preventing
the Operator Presence ON/OFF Lever Switch from operating as intended. Failure of the switch could result in a
runaway trowel and SERIOUS INJURY and/or property damage.
Solution:
If you own any of these models listed above, use the trowel only in its 230-volt configuration and for 230-volt
operation only. DO NOT CONTINUE OPERATING THE TROWEL USING 115-VOLT POWER. Conversion
(rewiring) to 230-volt operation should be done only by a qualified technician or a Multiquip service center.
10/16/19 N/A
Parts Information
Item Part No. Description Qty. Remarks
1 30721 Kit, 230V Wiring, Electric WBT 1
Includes
items 2–6
2 19688 Insulator, Splice Cap 2
3 19687 Crimp, Sleeve 2
4 34938 Wire Nut, Pre-Insulated Crimp 16-12 AWG 2
5 30718 Assembly, Pig Tail, 230V 1
6 30096 Terminal, Ring, 12-10 AWG, #8 3
Figure 1. Electric Walk-Behind Trowel
230V Wiring Kit Components
4
3
2
6
5
1
ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 2
WORK SAFELY!
Only a qualified service technician with proper training
should perform this procedure. Follow all shop safety
rules while performing this procedure.
REQUIRED TOOLS
Flat-head screwdriver
Phillips-head screwdriver
Wire strippers/crimpers/cutters
PREPARATION
Place the trowel on secure, level ground in an area free of
dirt and debris. Make sure the motor is turned OFF.
EXISTING PLUG REMOVAL
1. Remove the two screws securing the switch box cover
to the front of the main switch box (Figure 2). Keep the
screws for later.
Figure 2. Remove Main Switch Box Cover
2. Open the main switch box and disconnect the three
power cable wires (Figure 3).
MAIN SWITCH
BOX COVER
REMOVE
2 SCREWS
Figure 3. Disconnect Power Cable Wires
3. Remove the two small screws (Figure 4) securing the
existing power cable fitting to the main switch box.
Figure 4. Remove Existing Power
Cable Assembly
OF F
ON
L3
GND
L1
DISCONNECT
3 WIRES
MAIN
SWITCH BOX
EXISTING
POWER CABLE
REMOVE
2 SCREWS
REMOVE CABLE
AND FITTING
ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 3
4. Remove and discard the existing power cable and
fitting (Figure 4).
NEW PLUG INSTALLATION
1. Locate the 230V pigtail assembly (P/N 30718). Strip
the insulation back 1/4" from the end of each of the
three pigtail assembly wires (Figure 5).
Figure 5. Install Ring Terminals
2. Place a ring terminal (P/N 30096) onto the end of
each of the three pigtail assembly wires and crimp.
See Figure 5.
0.25"
230V PIGTAIL
ASSEMBLY
P/N 30718
RING TERMINAL
P/N 30096
3. Connect the three pigtail assembly wires inside the
main switch box as shown in Figure 6.
Figure 6. Install New Power Cable
4. Finish installing the 230V pigtail assembly (P/N 30718)
by inserting the push-on liquid-tight connector into
the open hole on the main switch box. Make sure the
connector is fully seated in the hole. See Figure 6.
5. Reinstall the switch cover using the two screws that
were removed earlier.
L3
GND
L1
CONNECT
3 WIRES
MAIN
SWITCH BOX
230V PIGTAIL
ASSEMBLY
P/N 30718
PUSH-ON
CONNECTOR
INSERT INTO
SWITCH BOX
HOLE
ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 4
Figure 7. Motor Wiring
CRIMP
SLEEVE
P/N 19687
WIRE NUT
P/N 34938
ELECTRIC
MOTOR
BLACK
ORANGE
WHITE
SPLICE CAP
INSULATOR
P/N 19688
BROWN
WHITE
RED
YELLOW
BLACK
YELLOW/BLACK
MOTOR WIRING
1. Connect the black, orange, and white motor wires as
shown in Figure 7 using a crimp sleeve (P/N 19687)
and splice cap insulator (P/N 19688).
2. Connect the red and yellow wires from the motor with
the white wire from the handle using a crimp sleeve
(P/N 19687) and splice cap insulator (P/N 19688).
See Figure 7.
3. Connect the yellow/black wire from the motor with the
black wire from the handle using a pre-insulated crimp
16-12 AWG wire nut (P/N 34938). See Figure 7.
4. Use the remaining pre-insulated crimp 16-12 AWG
wire nut (P/N 34938) to cap off the brown wire from
the motor. See Figure 7.
MATING CONNECTOR SELECTION
To connect the plug to a 240VAC receptacle, use an
extension cord with a NEMA L6-20R twist-lock mating
connector and a 12/3 wire gauge.
ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 5
NOTES
Your Local Dealer is:
HERE’S HOW TO GET HELP
PLEASE HAVE THE MODEL AND SERIAL
NUMBER ON-HAND WHEN CALLING
UNITED STATES
Multiquip Inc.
(310) 537- 3700
6141 Katella Avenue Suite 200
Cypress, CA 90630
E-MAIL: mq@multiquip.com
WEBSITE: www.multiquip.com
CANADA
UNITED KINGDOM
Multiquip Multiquip (UK) Limited Head Offi ce
(450) 625-2244
4110 Industriel Boul.
Laval, Quebec, Canada H7L 6V3
E-MAIL : infocanada@multiquip.com
0161 339 2223
Unit 2, Northpoint Industrial Estate,
Globe Lane,
Dukinfi eld, Cheshire SK16 4UJ
E-MAIL : sales@multiquip.co.uk
© COPYRIGHT 2019, MULTIQUIP INC.
Multiquip Inc
and
the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property
of their respective owners and used with permission.
The information and specifi cations included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in
this document are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifi cations, design or the information published
in this publication at any time without notice and without incurring any obligations.
Service Bulletin
Electric Walk-Behind Trowel 230V Wiring Update
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

MQ Multiquip J36E2 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document