Page 4
Service handbook CP300
Art. no.: 714095 rev.: b
6 Functional Checks .................................26
6.1 Service interval................................................................... 26
6.2 General Unit Integrity Check ............................................. 27
6.2.1 Procedure......................................................................................... 27
6.2.2 Continuous Printout (Internal thermal printer only).......................... 28
6.3 Functional Checks and Tests............................................ 29
6.3.1 External Sight Control...................................................................... 29
6.3.2 Mains and Battery Indicators (LED) test .......................................... 30
6.3.3 Battery Capacity Check.................................................................... 30
6.3.4 Keyboard Test.................................................................................. 30
6.3.5 LCD Screen Test.............................................................................. 31
6.3.6 Printer Checks.................................................................................. 32
6.3.7 ECG Amplifier and Patient Cable Test (Electrode/ Lead Resistance) 33
6.3.8 ECG Printout Reference .................................................................. 34
6.4 I / O Port Checks................................................................. 37
6.4.1 Equipment Required........................................................................ 37
6.4.2 Checking the RS-232 ports.............................................................. 38
6.5 Safety tests ......................................................................... 39
6.5.1 Maximum Values Safety Test .......................................................... 39
7 Software, Firmware and Test Screen ...40
7.1 Unit Settings ....................................................................... 41
7.1.1 Importing / Exporting / Reset to Default........................................... 41
7.2 Updating Firmware............................................................. 42
7.3 Updating the Software ...................................................... 42
7.4 Updating the Unit Options................................................. 43
7.5 Tests Screen ....................................................................... 44
8 Replacing Major Components ...............45
8.1 Safety Notes........................................................................ 45
8.2 Overview.............................................................................. 45
8.3 Opening the Unit................................................................. 46
8.4 Main Board MK 17-1 & PC1-1 Board................................. 47
8.5 ECG Board MK 16-2............................................................ 48
8.6 Thermal Printer................................................................... 48
8.6.1 Removing......................................................................................... 48
8.6.2 Replacing......................................................................................... 48
8.7 Battery ................................................................................. 48
8.8 Reassembling the Unit....................................................... 49
8.8.1 Internal Sight Control ....................................................................... 49
8.8.2 Functional Test................................................................................. 49
9 Unit Settings ...........................................50
9.1 Settings at Administrator login level................................ 50
9.1.1 System............................................................................................. 50
9.1.2 Login/Startup, Users, Institutes, Departments ................................. 54
9.1.3 ECG................................................................................................. 55
9.2 Settings at Physician/Administrator level........................ 56
9.2.1 General Filter................................................................................... 56
9.2.2 QRS /Trigger / DC Input / DC Output............................................... 57