5 PARAMETER GROUPS.........................................60
5.1 Introduction ................................................60
5.2 LED and LCD Display Parameters Cross Reference .........................61
5.3 LED Display Parameters .........................................62
5.4 LCD Display Parameters.........................................66
5.4.1 Quick Start Group ...............................................66
5.4.2 Control Function Group ...........................................67
5.4.3 Protection Group ...............................................68
5.4.4 I/O Group ...................................................68
5.4.5 Function Group ................................................70
5.4.6 LCD Fault Group ...............................................71
5.4.7 LED Fault Group ...............................................71
6 PARAMETER DESCRIPTION .....................................74
6.1 Parameter Descriptions .........................................74
7 THEORY OF OPERATION .......................................132
7.1 Solid State Motor Overload Protection .................................132
7.1.1 Overview ....................................................132
7.1.2 Setting Up The MX
2
Motor Overload ....................................132
7.1.3 Motor Overload Operation ..........................................134
7.1.4 Current Imbalance / Negative Sequence Current Compensation ....................134
7.1.5 Harmonic Compensation ...........................................135
7.1.6 Hot / Cold Motor Overload Compensation ................................135
7.1.7 Separate Starting and Running Motor Overload Settings ........................136
7.1.8 Motor Cooling While Stopped ........................................137
7.1.9 Motor Cooling While Running........................................138
7.1.10 Emergency Motor Overload Reset .....................................138
7.2 Motor Service Factor ...........................................139
7.3 Acceleration Control ...........................................140
7.3.1 Current Ramp Settings, Ramps and Times .................................140
7.3.2 Programming A Kick Current ........................................141
7.3.3 TruTorque Acceleration Control Settings and Times ...........................141
7.3.4 Power Control Acceleration Settings and Times..............................143
7.3.5 Open Loop Voltage Ramps and Times ...................................145
7.3.6 Dual Acceleration Ramp Control ......................................147
7.4 Deceleration Control ...........................................149
7.4.1 Voltage Control Deceleration ........................................149
7.4.2 TruTorque Deceleration ...........................................150
7.5 Braking Controls .............................................151
7.5.1 DC Injection Braking, Standard Duty ....................................152
7.5.2 DC Injection Braking, Heavy Duty .....................................152
7.5.3 Braking Output Relay .............................................152
7.5.4 Stand Alone Overload Relay for emergency ATL (Across The Line) operation ............152
7.5.5 DC Injection Brake Wiring Example.....................................153
7.5.6 DC Brake Timing ...............................................154
7.5.7 DC Injection Brake Enable and Disable Digital Inputs ..........................155
7.5.8 Use of Optional Hall Effect Current Sensor ................................155
7.5.9 DC Injection Braking Parameters ......................................156
7.6 Slow Speed Cyclo Converter ......................................156
7.6.1 Operation ....................................................156
7.6.2 Slow Speed Cyclo Converter Parameters ..................................157
7.7 Inside Delta Connected Starter .....................................158
7.7.1 Line Connected Soft Starter .........................................158
7.7.2 Inside Delta Connected Starter........................................159
iv