Remotec ZXT-120 is a Z-Wave-to-AC IR extender that works with any Z-Wave compliant gateway or controller. It can be used to control your air conditioner, heater, or other IR-controlled devices. The ZXT-120 has a built-in IR code library that supports most of the popular air conditioner brands in the market, so you don't need to have any IR control code knowledge. You can use your Z-Wave controller or gateway to select the IR code according to the ZXT-120 code list. The ZXT-120 also has a built-in temperature sensor, so you can use it to monitor the temperature in your room.

Remotec ZXT-120 is a Z-Wave-to-AC IR extender that works with any Z-Wave compliant gateway or controller. It can be used to control your air conditioner, heater, or other IR-controlled devices. The ZXT-120 has a built-in IR code library that supports most of the popular air conditioner brands in the market, so you don't need to have any IR control code knowledge. You can use your Z-Wave controller or gateway to select the IR code according to the ZXT-120 code list. The ZXT-120 also has a built-in temperature sensor, so you can use it to monitor the temperature in your room.

Z-Wave ZXT-120
User's Manual
ZXT-120
(Z-Wave-to-AC IR Extender)
Z-ExtenderTM ZXT-120
(Z-Wave-to-AC IR Extender)
Operating Instructions
Introduction
TheZXT120isaZWavetoIRextenderforairconditioner(AC),
(Figure1),itworkswithanyZWavecompliantgatewayorcontroller
bytranslatingZWaveThermostatCommandstoACIRcontrolcode.
UsercanselecttheIRcodefromthebuiltincodelibraryofZXT120,
oruselearningfunction,byusingZWaveConfigurationCommands
accordingtotheparametertable.ZXT120isalsowithbuiltin
temperaturesensorwhichallowsgatewayorcontrollertogetthe
currentroomtemperature.
Figure 1 ZXT-120
ZXT120canbeconfiguredaseitherFrequentlyListeningRouting
Slaves(FLiRS)orAlwaysListeningnodeafterexclusionprocess
(beforeinclusionprocess).
FLiRSnodetypeisforbatteryoperatedapplicationsanditwillenter
sleepmodefrequentlyinordertoconservebatteryconsumptionthat
canprovidetheflexibilityifthereisoutof5Vdcpowersource.Also,
usercanplacetheunitinanywhereathome.
AlwaysListeningnodetypeisfortheneedsoffastresponse
application.Itworkswith5Vdcpowersource.AlwaysListeningnode
canactasarepeater,whichwillretransmittheRFsignaltoensure
thatthesignalisreceivedbyitsintendeddestinationbyroutingthe
signalaroundobstacleandradiodeadspots.
ZXT120supportsNetworkWideInclusion(NWI)andExploreFrames.
ItalsosupportsZWavenetworkswithmultiplegatewaysand
controllers.LikeeveryZWaveaccessory,userwillneedtoincludethe
ZXT120intotheirZWavenetworkusingtheprimarycontroller.Then,
theusercanuseeithertheprimarycontrollerorsecondarycontroller
toconfigureandsetuptheZXT120usingZWave’sconfiguration
commandclass.Oncetheconfigurationandsetupiscomplete,the
controllercanuseZWave“Thermostatcommandsclass”tocontrol
theirIRcontrolledairconditionerthroughtheZXT120.
ControllerandGatewayRequirements
TheZXT120canworkwithanyZWavecompliantcontrolleror
gatewaysupportingthefollowingZWavecommands.
- ConfigurationCommandClass
- MultilevelSensorCommandClass
- ThermostatCommandClass
ThermostatModeCommandClass
ThermostatFanModeCommandClass
ThermostatSetpointCommandClass
BuiltinIRcodelibrary
TheBuiltinIRcodelibrarysupportsmostofthepopularair
conditionerbrandsinthemarket.ZWavegatewayandcontroller
doesnotneedtohaveanyIRcontrolcodeknowledge.UsercanuseZ
WavecontrollerorgatewaytoselecttheIRcodeaccordingtotheZXT
120codelistseparatelyprovidedthroughZWaveconfiguration
command.
Glossary
Deviceor
Node
Devicesandnodesarealltermstodescribean
individualZWavedevice.Theseareall
interchangeablewhensettingupyourZWave
network.
InclusionAddaZWavedevicetothenetwork.
ExclusionDeleteaZWavedevicefromthenetwork.
Remove
Totakeadeviceoutofagroup,sceneor
associationgroupwhilethatdevicestillexists
inthesameZWavenetwork.
ZWave
Network
AcollectionofZWavedevicesiscontrolledby
primaryandsecondarycontrollersoperating
onthesamesystem.AZWavenetworkhasits
ownuniqueIDcodesothatcontrollersnotin
thenetworkcannotcontrolthesystem.
Primary
Controller
Thefirstcontrollerisusedtosetupyour
devicesandnetwork.OnlythePrimary
Controllercanbeusedtoincludeordelete
devicesfromanetwork.Itisrecommended
thatyoumarktheprimarycontrollerforeach
networkforeaseinmodifyingyournetwork.
Secondary
Controller
Acontrollercontainingnetworkinformation
aboutotherdeviceswithinthenetworkandis
usedforcontrollingdevices.Secondary
controlleriscreatedfromthePrimary
Controllerandcannotincludeordeletedevices
tothenetwork.
Inclusion
Controller
Acontrollercontainingnetworkinformation
aboutotherdeviceswithinthenetworkandis
usedforcontrollingdevices.Inclusion
controlleriscreatedfromthePrimary
ControllerinaSISenabledZWavenetwork.
InclusionControllershavetheabilitytoadd
andremovedevicesfromthenetwork.
ZXT120Operations
BeforeusingtheZXT120,pleasereadthe[INSTALLATION]ifyouneed
tomounttheZXT120toawall.PoweruptheZXT120bytheUSB
Power5VdcorDrybatteryAAAx3pcs.
Plugin5VdcpowerintotheUSBsocketifoperatedatAlways
Listeningmode.Or
Install3xAAAbatteriesifoperatedatFLiRSmode.
Pleaserefertothesectionof[MOUNTINGPROCEDURE].
RemovethebatterycoveronthebackofyourZXT120battery
chassis.
Mountthebatterycoverintothemainunitwith2screws.
Checkthepolarityofthebatteriesandthe"+/"marksinsidethe
batterycompartment.
Insertthebatteries.
Pushthebatterycoverandmainunitbackinplace.
LCAUTION(batteryandpoweradaptorsafety)
Usenewbatteriesoftherecommendedtypeandsizeonly.
Nevermixusedandnewbatteriestogether.
Toavoidchemicalleaks,removebatteriesfromtheZXT120if
youdonotintendtousetheremoteforanextendedperiod
oftime.
Disposeofusedbatteriesproperly;donotburnorburythem.
(Pleasecarefullyreadthroughthefollowingthenstorethemanualfor
futurereference.)
ProductOverview
Figure 2 PROG Key and IR Port of ZXT-120
Temperature sensor
“PROG” Button,
Learning and LED
Indication
External
IR Port USB Power
5V DC
Battery
chassis
Surround IR Output for
top and 4-directions
ZWaveRemoteControl
1) Selectyouroperationmode;pleaserefertoListeningMode
section.
2) IncludeorExcludetheunitfromtheexistingZWavehome
controlnetworkwithyourprimarycontroller.
‐ Refertoyourprimarycontrollerinstructionstoprocess
theinclusion/exclusionsetupprocedure.
‐ Whenpromptedbyyourprimarycontroller,clickonce
onthePROGbutton.
‐ Theprimarycontrollershouldindicatethattheaction
wassuccessful.Ifthecontrollerindicatestheactionwas
unsuccessful,pleaserepeattheprocedure.
3) Usercanuseeitherprimarycontrollerorsecondarycontroller
(shouldsupportconfigurationcommandclass)tosetuptheZXT
120ACcodebytheparameter27(IRcodenumberforbuiltin
codelibrary),pleaserefertocodelistfortheparametervalue
thensetupyourACcontrolcode.
4) Oncetheconfigurationandsetupwerecompleted,the
controllercanuseZWave“Thermostatcommandsclass”to
controltheirIRcontrolledairconditionerwiththeZXT120.
5) Youcanrecorddownyourdevicecodeunderthebelowtablefor
futurereferenceaftersettinguptheZXT120correctly.
ACdeviceprogrammedtoyourZXT120
Codeno.:
ZXT120Information
HowtogettheNIF“NodeInformationFrame”onZXT120(Inclusion)
StepSetupKeyLEDIndicationStatus
onZXT120
1
PressthePROGbuttononthe
ZXT120
LEDflashesonce
thenstayoff
(ZXT120willreport
thesupported
commandclass)
ParameterNo.andParameterValueofconfigurationcommand
Parameter
NumberDefinitionsParameterValue
25
(0x19)
IndicatealocationforIRcode
learningandstartlearning
022
(0x000x16)
26
(0x1A)
Learningstatusregister
Note:
Thestatusvalue0x01and
0x04willberesetto0when
theZXT120receiveaget
commandtothisparameter
0x00:Idle‐thisIR
channelisidle
(default)
0x01:OK‐thelatest
learningprocess
successfuland
completed
0x02:Learning‐the
ZXT120isbusy
processingprevious
learningrequest
0x04:Failed‐the
latestlearning
requestfailed
27
(0x1B)
IRcodenumberforbuiltin
codelibrary
Refer“Codelist”for
details
28
(0x1C)
ExternalIREmitterpower
level
0x00:normalpower
mode
0xFF:highpower
mode(default)
32
(0x20)
SurroundIRcontrol
- toavoidtheIRinterference
bydisablingthe
surroundingIRemitterif2
0x00:disable
SurroundIREmitters
0xFF:enable
SurroundIREmitters
airconditionersinaroom
areused
- extendthebatterylifeby
disablingtheSurroundIR
Emitters
(default)
33
(0x21)
ACfunction“SWING”control0x00:SWINGOFF
0x01:SWINGAUTO
(Default)
35
(0x23)
LearnlocationstatusBitmask=1,learn
locationhaslearn
data.Otherwise,Bit
mask=0
SeefigureLearn
locationasbelow
ParameterTable
6 45 3 2 1 07
0 00 0 0 1 01 BitMaskByte1
Location07
BitMaskByte2
Location815
BitMaskByte3
Location1623
BitMaskByte4
[Reseved]
6 45 3 2 1 07
0 10 0 0 0 10
6 45 3 2 1 07
0 00 0 0 0 10
6 45 3 2 1 07
0 00 0 0 0 00
Figure:Learnlocation
Ontheaboveexample,location1,7,8,12,16haslearneddata.
LMappingInformation
BASICSetValue0x00willmaptoThermostatmodeOff0x00.
BASICsetValue0xFFwillmaptoThermostatmodeResume0x05.
ListeningModeChange(defaultmodeisFLiRS)
ZXT120canbeconfiguredaseitherFrequentlyListeningRouting
Slaves(FLiRS)orAlwaysListeningnodeafterexclusionprocess.
FLiRSnodetypeistargetedforbatteryoperatedapplicationsandit
willentersleepmodefrequentlyinordertoconservebattery
consumption.
AlwaysListeningnodetypeistargetedfortheneedsofrequiredafast
responseapplication.
Important:
ItisnotallowedtochangingZXT120operationmodewithout
exclusionprocess(donotchangeZXT120operationmodewhileZXT
120isincludedinanetwork).
HowtoswitchZXT120listeningmodefromAlwaysListeningto
FLiRS(orviceverse)
StepSetupKeyLEDIndicationStatus
onZXT120
1PressandholdthePROGbuttonon
theZXT120foraround4seconds
LEDstayoff
2
Releasethebuttonandthenpress
thePROGbutton3timeswithin2
seconds
LEDflashestwice
thenstayoff
(ZXT120setinFLiRS
mode)
OR
LEDflashesfour
timesthenstayoff
(ZXT120setin
AlwaysListening
mode)
IRCodeSelection
ZXT120iswithbuiltinIRACcodelibrary,usermayselecttheIRcode
usingConfigurationCommandClass.
StepSetupKeyLEDIndicationStatus
onZXT120
1
AfterincludedZXT120toZWave
controllerorGateway,gotodevice
setupforconfigurationongateway
orcontroller.
‐
2
Inputparameternumber“27”and
parametervalue(pleaselookupthe
codelistofZXT120accordingto
yourACbrand).Thencompletethe
configurationprocess.
‐
3
PressthePROGbuttonontheZXT
120.(thisstepapplywhenusing
ZRC100orotherportablecontroller
forsetup,ifusinggateway,usercan
skipthisstep)
LEDflashesonce
whenZXT120
receivesthe
configuration
setting
4
GobacktothecontrolpageofZXT
120onthegatewayandtrythe
functionsuchas(cool,temperature
set).
Iftheairconditionerdoesnot
respondtothecommandyouseton
Gateway(Cool,Heat,Auto,
Temperaturesetetc.),repeatstep2
and3toselectthenextcodeon
codelist.
LEDflashesonce
everytimeit
receivesa
commandfrom
gateway
LImportantInformation
Differentbrandormodelofairconditionerhasdifferent
function.Forexample,someairconditioneronlysupport
temperaturesetfrom18oC30oC,ifuserset17oCongateway,
ZXT120willnotrespond.
Therearemorethan1codeforeachbrand,somedoesnot
supportheat,ifuserselectedacodethatdoesnotsupport
heatbuttheoriginalairconditionersupportsheatfunction,
pleasecontinuetotrynextcodeuntilthecorrectoneis
selected.
Ifnoneofthecodeworksonthetargetairconditioner,orthe
airconditionerbrandisnotshownonthecodelist,please
selectcode“000”forIRcodelearning(refertoinstructionof
IRCodeLearning)
IRCodeLearning
Incasenoneofthecodeonthecodelistworksforthetargetedair
conditioner,usercanuseIRcodelearningfunctionusingconfiguration
accordingtobelowsteps:
StepSetupKeyLEDIndicationStatus
onZXT120
1
Gotoconfigurationsettingpageon
thegatewayorZRC100andinput
parameternumber“27”and
parametervalue“000toselectthe
dedicatedACcodenumber“000”
forlearning.
LEDflashesonce
whenZXT120
receivesthe
configuration
setting
2
Lookupbelowmappingtable(value
022)forlearning,anddecidetheIR
settingyouintenttolearnnext.
Forexample“22°C,cool”which
matchesvalue“5”(IRcodetobe
learntwilllocateat“5”inZXT120).
Setyouroriginalairconditioner
remoteat“22°C,cool”andturnit
off.(Besidestemperatureand
mode,youmaysetotherdesired
settings,suchasFan,Swingetc.)
‐
3
Gotoconfigurationsettingpageon
thegatewayorZRC100andinput
parameternumber“25”and
parametervalue“5”(inthiscase).
‐
4
PressthePROGbuttonontheZXT
120.(thisstepapplywhenusing
ZRC100orotherportablecontroller
forsetup,ifusinggateway,usercan
skipthisstep)
LEDflashesonce
whenZXT120
receivesthe
configuration
setting
ZXT120isreadyto
learn
5
Aimtheoriginalairconditioner
remoteatZXT120accordingto
belowpositionwithin13inches
LEDflashestwiceif
learningissuccessful.
LEDflashes6timesif
it’sfailed.
Press“poweron”buttononthe
originalairconditionerremote.
Ifthelearningisfailed,repeatstep3
tostep5.
TolearnnextIRcode,repeatstep2
tostep5.
LWhenyouencounterproblem,checkfollowings:
Makesureyouroriginalremoteisswitchedtopoweroff.
Pressthekeyonoriginalremotebeforelearningmode
timeout.
Keepawayfromincandescentlightanddirectsunlightduring
learning.
MakesureIRTransmitterofyouroriginalremotealightwith
learningdiodeofZXT120,youmayalsoslightadjustcloseror
furtherawaythedistanceoftwodevices.Someofremotes
theIRtransmitterinhiddenbehindlensandmaynotinstalled
centerofremote.
Makesurethepowerisgoodonbothdevices,especiallythe
originalremote.Usefreshbatteries.
IRLearningMappingTable(Parameternumber25)
ParameterValue
(Location)
Thermostatcommand
&IRsetting
0OFF
1ON(resume)
219°Ccool
320°Ccool
421°Ccool
522°Ccool
623°Ccool
724°Ccool
825°Ccool
926°CcoolDefaultCool
1027°Ccool
1128°Ccool
1219°Cheat
1320°Cheat
1421°Cheat
1522°CheatDefaultHeat
1623°Cheat
1724°Cheat
1825°Cheat
1926°Cheat
2027°Cheat
2128°Cheat
22Drymode
LImportantInformation
Afteralllearningcompleted,usercangobacktotheZXT120
controlpageonthegatewayfornormaloperation.
OnthegatewayUI,usercanonlyusethetemperaturerange
fromthemappingtable,OFF,ON(RESUME),COOL,HEAT,
DRY,IfuserpressthebuttonofFAN,orotherfunctiononthe
gatewayUIwhichisnotlistedinabovetable,ZXT120willnot
respond.
IfuseronlylearntON,OFF,orpartofthesettingsaccording
totheabovetable,ZXT120willsendthelearntdatatothe
airconditioneronly.Forexample,useronlylearntON,OFF,
22°CCool,24°CHeat,ZXT120willnotsendIRdatatoair
conditionerifuserset27°CCoolonthegateway.
ZXT120hasbeenpredefineddefaultcoolat26°C,default
heatat22°C,whenuserpressCoolongatewaywithout
settingtemperature,ZXT120willsendthelearntdataof26°C
Cooltoairconditioner.WhenuserpressHeatongateway
withoutsettingtemperature,ZXT120willsendthelearnt
dataof22°CHeattoairconditioner.
Thereisonlyonecodefordrymode,usercansetitatany
preferredtemperature.
Usercanstillusegatewaytosetupsceneandschedulewith
ZXT120,forexample,tohaveACturnonat23°Ceverydayat
7pm,25°Cat11pm.Justmakesurethesetcodeislearnt.
Thelearningmappingtableisforsplitairconditionerwhich
remotecontroliswithLCDdisplay.Forwindowtypeair
conditioner(whichremotecontroliswithoutLCDdisplay),
themappingtablewithtemperaturesdonotapply,dueto
differenttypeofIRcontrolprotocol.However,usermaystill
usetheOFF,orON/RESUME,DRYkeyforlearning.(Because
thePOWERkeyontheoriginalremotewithoutLCDdisplayis
toggle,usercanchooseeitherONkey,orOFFkeytolearn
Powerkey,afterlearningisdone,pressoncetoturnonthe
airconditioneriftheairconditionerisOFF,pressoncetoturn
offiftheairconditionerisON)
ResetZXT120tofactorydefault
Pressandhold“PROG”buttonfor10secondsonZXT120.TheLEDwill
flashtwiceuntilresetprocessiscompleted.
Note:ThisresetstepwillnotaffecttheoperationmodeofZXT120,
usershouldreferto
ListeningMode
sectionifyouwanttochange
theoperationmode.
LInformation
IfyouareusingGatewayorotherZwavecontrollersto
operateZXT120,Pleasefollowtheinstructionfromthe
gatewayorothercontroller.
Youcancheckeitherthespecificationsinthemanualofyour
ZXT120oralsocheckonlineatwww.remotec.com.hkfora
fulllistofproductsthatcanbeusedwithyourZXT120.
INSTALLATION
MOUNTINGTHEZXT120TOAWALL
MOUNTINGLOCATIONPRECAUTIONS
Beforemounting,checkthematerialandstructureofthe
mountinglocation.Ifthelocationdoesnothavetheproper
materialorstructure,theZXT120canfallandcauseinjuries.
Usecommercialitemsthatbestmatchthewallstructureand
materialforthescrewsandotherfixtures.
Donotmountnearakitchencounter,humidifier,orother
locationinwhichitcanbeexposedtosmokeorsteam.Doingso
couldcauseafireorelectricalshock.
Donotmountinlocationswithhighhumidityorlargeamountsof
dust.Doingsocouldcauseafireorelectricalshock.
Donotmounttolocationssubjecttohightemperatures,high
humidity,orexposuretowater.Doingsocouldcauseafireor
electricalshock.
Donotmounttolocationssubjecttolargeamountsofvibration,
largejolts,orlargeforces.ThesecouldcauseaninjuryiftheZXT
120fallsandbreaks.
MOUNTINGPROCEDUREPRECAUTIONS
DonotmodifypartsorusetheZXT120inwaysotherthanits
intendeduse.DoingsocouldcausetheZXT120tofallandresult
inaninjury.
Besuretofullycheckthattherearenoelectricalwiresorpipes
insidethewallbeforemounting.
Ifanyofthescrewsareloose,theZXT120canfallandcausean
injury.DonotmounttheZXT120withthescrewsstillloose.
Checkthatthetwoscrewsmountedtothewallarefullyinserted
intothekeyholesoftheZXT120.Otherwise,theZXT120canfall
andcauseaninjury.
DonotmounttheZXT120sothatitsticksoutfromthewalledge.
Itcouldgethitbypeoplesbodiesorobjectsandcauseaninjury.
Supplierwillnotbeliableforanyaccidentsorinjuriesthatoccur
duetoimpropermountingorhandling.
Whenmounting,becarefulnottogetyourfingerspinchedor
injureyourhands.
MOUNTINGPROCEDURE
TheZXT120canbemountedtoawallorwoodenracksusingthetwo
keyholesinthebottomcase.
Note 1: The reception sensitivity varies depending on the antenna
direction.
Note 2: Before mounting to a wall, be sure to fully read the precautions.
1. Obtaintwoscrewssuitableforthewallstrengthandmaterial.
Thescrewsizeisshowninthefigurebelow.
2. ThepositionalrelationshipbetweentheZXT120keyholesand
thescrewmountingpositionsareshowninthefigurebelow.
Note 1: When mounting the screws to the wall, leave a space
between the wall and screw cap as shown in the figure.
3. InserttheZXT120keyholesontothetwoscrewsmountedto
thewall,andthenslidedownwardtosecureinplace.
4. AftersecuringtheZXT120tothewall,connecttheUSBPower
orbatteriesandIRemittercabletotheZXT120.
Note 1: Check that the ZXT-120 is firmly secured to the wall.
Note 2: Insert USB plug or batteries and IR emitter cable so that
they are firmly connected to the ZXT-120.
5. WhenremovingtheZXT120fromthewall,liftuptheZXT120,
thenpullittowardsyou.
6. Detachthemainunitfromthebatterychassisbymovetoward
totopposition.
WIRELESSINFORMATION
Wirelessrange:
Thisdevicehasanopenairlineofsighttransmissiondistanceof100
feetwhichcomplieswiththeZWavestandards.Performancecanvary
dependingontheamountofobjectsinbetweenZWavedevicessuch
aswallsandfurniture.EveryZWavedevicesetupinyournetworkwill
actasasignalrepeaterallowingdevicestotalktoeachotherandfind
alternateroutesinthecaseofareceptiondeadspot.
Radiofrequencylimitations:
1. Eachwallorobject(i.e.:refrigerator,bookshelf,largeTV,etc)can
reducethemaximumrangeof65feetbyupto25to30%.
2. Plasterboardandwoodenwallsblocklessoftheradiosignalthen
concrete,brickortilewallswhichwillhavemoreofaneffecton
signalstrength.
3. WallmountedZWavedeviceswillalsosufferalossofrangeif
theyarehousedinmetaljunctionboxeswhichcouldalsoreduce
therangebyupto25to30%.
MAINTENANCE
1 DonotexposeyourZXT120todust,strongsunlight,humidity,
hightemperaturesormechanicalshocks.
2 Donotuseoldandnewbatteriestogetherasoldbatteriestendto
leak.
3 DonotusecorrosiveorabrasivecleansersonyourZXT120.
4 Keeptheunitdustfreebywipingitwithasoft,drycloth.
5 DonotdisassembleyourZXT120,itcontainsnouserserviceable
parts.
FREQUENTLYASKEDQUESTIONS
ZWaveFrequentlyAskedQuestions
QWhywontmyZXT120workwiththeZWavedevicesI
purchasedfromanothercountry?
ADuetodifferentcountriesregulationsZWaveproductsfrom
differentregionsaresettodifferentfrequencies.Before
purchasingnewdevicesmakesureyouhavecheckedthatthe
deviceiscompatibleinyourregion.
QHowdoIknowwhichproductiscompatiblewithmyZXT120?
A ZXT120shouldworkwithanyZWavecontrollerorgatewaythat
hascontrolcapabilityfor“Thermostat”devices.Youcancheck
eitherthespecificationsinthemanualofyourZXT120oralso
checkonlineatwww.remotec.com.hkforafulllistofproducts
thatcanbeusedwithyourZXT120.AllZWaveproductsalso
comewiththeZWavelogo.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Remotec ZXT-120 User manual

Type
User manual

Remotec ZXT-120 is a Z-Wave-to-AC IR extender that works with any Z-Wave compliant gateway or controller. It can be used to control your air conditioner, heater, or other IR-controlled devices. The ZXT-120 has a built-in IR code library that supports most of the popular air conditioner brands in the market, so you don't need to have any IR control code knowledge. You can use your Z-Wave controller or gateway to select the IR code according to the ZXT-120 code list. The ZXT-120 also has a built-in temperature sensor, so you can use it to monitor the temperature in your room.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI