GENERAL INFORMATION
INTRODUCTION
The Sony/Tektronix 305 DMM Oscilloscope is a versatile
solid-state (except crt> portable instrument that combines
small size and light weight with the ability to make preciī
sion waveform and digital measurements associated with
industrial, military, computer maintenance, and business
machine applications. The 305 is mechanically constructed
to withstand shock, vibration and other environmental
extremes associated with portability. Operating power for
the instrument is provided by external dc, rechargeable
batteries, or normal power-line voltage. Internal circuitry
recharges the batteries whenever the instrument is connectī
ed to power-line voltage. Selection of the DMM or oscilī
loscope function (or both} is made with front panel push
buttons.
The DMM is autoranging and measures resistance, ac
voltage and dc voltage. Full scale measurements are 2 megī
ohms, 700 Vac and 1000 Vdc. The front panel digital readī
out is a 3
-Vi digit display containing an automatic negative
polarity indicator and decimal point locator. No polarity
indication is shown for positive measurements. Input conī
nectors for the multimeter are located on the right side of
the instrument cabinet.
Oscilloscope functions provide dual-channel, dc to 5
megahertz vertical deflection with calibrated deflection
factors of 5 millivolts/division to 10 volts/division in a 1-2-
5 sequence. The horizontal deflection system provides caliī
brated sweep rates from 0.5 second to 1 microsecond per
division. A X10 magnifier increases the indicated sweep rate
by a factor of ten, extending the fastest sweep rate of 0.1
microsecond/division. The trigger input may be internal or
external, with triggering effective over the full bandwidth
of the vertical deflection system. Calibrated X-Y measureī
ments are made with Channel 2 (Y) providing the vertical
deflection and Channel 1 (X) horizontal deflection. Oscilī
loscope signal input connectors are located on the left side
of the instrument cabinet The crt display is an 8 X 10 diī
vision graticule with each division measuring 0.632 centiī
meters (approximately 0.25 inches).
SAFETY INFORMATION
This operating manual contains information which the
user must follow to ensure safe operation of the instruī
ment. Warning information is intended to protect the
operator while Caution information protects the
instrument.
REV A SEP 1979 305 Operators 1