Chauvet Professional 18VW User manual

Category
Floodlights
Type
User manual

This manual is also suitable for

COLORdash™ Par-Tri 18VW QRG EN
2
About this
Guide
The COLORdash™ Par-Tri 18VW Quick Reference Guide (QRG) has basic
product information such as connection, mounting, menu options, and DMX
values. Download the User Manual from www.chauvetlighting.com
for more
details.
Disclaimer
The information and specifications contained in this QRG are subject to change
without notice.
Safety Notes
DO NOT open this product. It contains no user-serviceable parts.
DO NOT look at the light source when the product is on.
CAUTION: This product’s housing may be hot when lights are
operating.
Mount this product in a location with adequate ventilation, at least
20 in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product
while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT operate this product outdoors or in any location where dust,
excessive heat, water, or humidity may affect it.
DO NOT operate this product if the housing, lenses, or cables appear
damaged.
DO NOT connect this product to a dimmer or rheostat.
ONLY connect this product to a grounded and protected circuit.
ONLY use the hanging/mounting bracket to carry this product.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperature is 104° F (40° C). Do not operate
this product at higher temperatures.
Contact
Outside the U.S., United Kingdom, or Ireland, contact your distributor to
request support or return a product. Visit www.chauvetlighting.com
for contact
information.
What Is
Included
COLORdash™ Par-Tri 18VW
Power Input Cord
Accessory Holder
Gel Frame
Safety Cable
Warranty Card
Quick Reference Guide
EN COLORdash™ Par-Tri 18VW QRG
3
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
Power Linking
You can link up to 15 COLORdash™ Par-Tri 18VW products at 120 VAC or
28
at 230 VAC. Never exceed this number. Power linking cords can be
purchased separately.
AC Plug
Wire (U.S.)
Wire (Europe)
Screw Color
Black
Brown
Yellow/Brass
White
Blue
Silver
Green/Yellow
Green/Yellow
Green
Fuse
Replacement
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the
housing.
3. Remove blown fuse and replace with a good fuse of the same type and
rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The COLORdash™ Par-Tri 18VW will work with a DMX controller using a
regular DMX serial connection. A DMX Primer is available from
www.chauvetpro.com.
DMX Connection
The COLORdash™ Par-Tri 18VW uses a regular DMX data connection for its
DMX personalities: 2 Ch, 3 Ch, and 7 Ch. See the User Manual to connect and
configure for DMX operation.
Master/Slave
Connection
The COLORdash™ Par-Tri 18VW uses the DMX data connection for its
Mas
ter/Slave mode. See the User Manual to connect and configure for
Master/Slave operation.
COLORdash™ Par-Tri 18VW QRG EN
4
Mounting
Product
Mounting
Diagram
Control Panel
Description
Button
Function
<MENU>
Exits from the current menu or function
<ENTER>
Enables the currently displayed menu or sets the currently
selected value into the selected function
<UP>
Navigates upwards through the menu list and increases the
numeric value when in a function
<DOWN>
Navigates downwards through the menu list and decreases
the numeric value when in a function
Overhead Mounting
Floor Mounting
Secure the safety cable using
the passageway on the back
of the product.
Clamp
EN COLORdash™ Par-Tri 18VW QRG
5
Menu Options
Main Level
Programming Levels
Description
Auto Auto 1~5 Speed 000~100
5 automatic programs
Static
Fix C
W
Warm white
C
Cool white
CW
Cool/warm white
Manu C
W
Value 000~255
Combines cool white and warm white to
make a custom white color
C
Dim Mode
Off
No dimmer
DIM 1~3
Dimmer curve
BackLite
10S
Turns off display backlight after 10 sec of
inactivity
20S
Turns off display backlight after 20 sec of
inactivity
30S
Turns off display backlight after 30 sec of
inactivity
On
Display backlight always on
Info
Auto
Test
Turns on all LEDs in sequence for testing
FixHours
Shows total operating hours
Version
Shows installed software version
Address 001~511
Selects DMX address (highest channel
restricted to personality chosen)
Channel
2 Ch
2-channel: C/W control
3 Ch
3-channel: C/W, dimmer
7 Ch
7-channel: C/W, dimmer, strobe, auto
programs, dimmer speed, auto speed
M/S Mode
Master
DMX mode
Slave
Slave mode
White Balance
W
Value 125~255
Sets white LED maximum value
C
Sets cool LED maximum value
COLORdash™ Par-Tri 18VW QRG EN
6
DMX Values
7 Ch
Channel
Function
Value
Percent/Setting
1
Dimmer
000 ó 255
0~100%
2
Warm White
000 ó 255
0~100%
3
Cool White
000 ó 255
0~100%
4 Strobe
000 ó 010
011 ó 255
No function
Slow to fast
5 Auto Programs
000 ó 051
052 ó 101
102 ó 152
153 ó 203
204 ó 254
255
No function
Auto 1
Auto 2
Auto 3
Auto 4
Auto 5
6
Auto Speed
000 ó 255
Slow to fast
7 Dimmer Speed
000 ó 051
052 ó 101
102 ó 152
153 ó 203
204 ó 255
Preset dimmer speed from display menu
Linear dimmer
Nonlinear dimming curve 1 (fastest)
Nonlinear dimming curve 2
Nonlinear dimming curve 3 (slowest)
3 Ch
Channel
Function
Value
Percent/Setting
1
Dimmer
000 ó 255
0~100%
2
Warm White
000 ó 255
0~100%
3
Cool White
000 ó 255
0~100%
2 Ch
Channel
Function
Value
Percent/Setting
1
Warm White
000 ó 255
0~100%
2
Cool White
000 ó 255
0~100%
COLORdash™ Par-Tri 18VW QRG Multi-Language
COLORdash™ Par-Tri 18VW QRG, Rev. 2 ML│ © Copyright 2013 CHAUVET®
All rights reserved. Printed in P. R. C.
Contact Us
World Headquarters
CHAUVET®
General Information
Address: 5200 NW 108th Avenue
Sunrise, FL 33351
Voice: (954) 577-4455
Fax: (954) 741-5571
Toll free: (800) 762-1084
United Kingdom and Ireland
CHAUVET® Europe Ltd.
General Information
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0)1773 511115
Fax: +44 (0)1773 511110
Technical Support
Voice: (954) 577-4455 (Press 4)
Fax: (954) 756-8015
Email: tech@chauvetlighting.com
Technical Support
Email: uktech@chauvetlighting.com
World Wide Web
www.chauvetlighting.com
World Wide Web
www.chauvetlighting.co.uk
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Chauvet Professional 18VW User manual

Category
Floodlights
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI