Reflectix DBWEF48050 Installation guide

Type
Installation guide

This manual is also suitable for

T
e
ch
n
ical
Dat
a:
Tem
p
era
t
u
re
R
a
ng
e:
-6
0
d
eg
rees
t
o
+1
8
0
d
eg
r
ees
F
N
om
i
na
l
T
hi
c
k
nes
s
:
5
/1
6
i
nc
h
(
.3
1
2
)
Wei
g
ht
:
1
.2
5
oz
./s
q
.
f
t
.
L
inea
r
Shrinka
g
e:
None
Wa
t
er
Va
p
or
Tr
a
nsmission
(AST
M
E
9
6
):
0
.0
2
Perms
Pu
nc
t
u
re
Resist
a
nc
e:
6
0
lb
./in.
Mold
a
nd
Mild
ew:
N
o
Growt
h
T
ensile
St
reng
t
h:
3
.7
N/m
m
Plia
b
ilit
y
:
No
Cr
a
c
king
Phy
sic
a
l
Prop
er
t
ies
-
Comp
r
ession:
6
%
Introducing the
Reflectix
®
Concrete
Slab Insulation
B
e
n
e
fits
:
R-
v
al
u
e
1
.
1
En
h
an
c
es
Radi
an
t
F
l
o
o
r
S
yst
em
s
Vapo
r
Ret
ar
der
N
o
n
-
T
o
xi
c
/N
o
n
-
Car
c
i
n
o
gen
i
c
F
i
ber
F
r
ee
Rado
n
Ret
ar
der
In
st
al
l
s
Q
u
i
c
k
l
y
an
d
Easi
l
y
L
i
gh
twei
gh
t
an
d
Cl
ean
N
ot
A
ffected
by
Moi
sture/H
umi
di
ty
N
o
N
esti
n
g
Ch
aracteri
sti
cs
for
In
sects
N
o
N
eed
for
Protecti
ve
G
armen
ts
or
Respi
rators
Wh
en
In
stal
l
i
n
g
Refl
ecti
x
®
Con
crete Sl
ab
In
sul
ati
on
con
si
sts of seven
l
ayers.
T
h
e
fi
rst
l
ay
er
of
wh
i
te
pol
y
i
s
bon
ded
to
foi
l
to protect
from
l
i
me
i
n
curi
n
g
con
-
crete.
Each
outer l
ayer i
s bon
ded to a tough
l
ayer of pol
y
eth
yl
en
e for
stren
gth
.
T
wo i
n
n
er l
ayers of i
n
sul
ati
n
g bubbl
es resi
st con
ducti
ve h
eat
fl
ow wh
i
l
e a cen
ter l
ayer of pol
y
eth
y
l
en
e gi
ves Refl
ecti
x
®
h
i
gh
rel
i
abi
l
-
i
ty
an
d
stren
gth
.
Recommended Produ
cts:
D
BWEF
48100
Uses:
I
nsula
tion (
a
nd
a
Va
p
or Moisture Reta
rder)
und
er a
Concrete Slab
I
nsulation under a
Ra
d
ia
nt Floor S
ystem (
in a
S
la
b)
I
nsula
tion und
er a
S
now Melt S
y
stem (
in a
S
la
b
)
White Poly
Foil
Clear Poly
Bubbles
Clear Poly
Bubbles
Clear Poly
Pictured Above:
Under a Concrete Slab (Top)
Radiant Heating in a Concrete Floor (Bottom)
Radiant Heating in a Concrete Floor:
1) Unroll Reflectix
®
Concrete Slab Insulation over the sand or
gravel, (white poly side up.)
2) Butt the seams.
3) Seal the seams with 3” wide poly tape. All tape should be
applied using a flat edge taping tool to assure good adhesion.
4) Install radiant heating and reinforcing rod, and then pour the
concrete as usual.
Builder’s Note: Adding 1” of sand over the Reflectix
®
Concrete
Slab Insulation will facilitate water drainage and shorten the
actual curing time.
F43 Rev 0619
Under a Concrete Slab:
1) Unroll Reflectix
®
Concrete Slab Insulation over the sand or
gravel, (white poly side up.)
2) Butt the seams.
3) Seal the seams with 3” wide poly tape. All tape should be
applied using a flat edge taping tool to assure good adhesion.
4) Install reinforcing rod and then pour the concrete as usual.
Builder’s Note: Adding 1” of sand over the Reflectix
®
Concrete
Slab Insulation will facilitate water drainage and shorten the
actual curing time.
Reflectix
®
Concrete Slab Insulation
Testing and Certification:
All tests on Reflectix
®
Insulation are performed at either nationally approved independent laboratories or at leading universities. Tests
are performed to current American Society of Testing and Materials (ASTM) Standards when a standard exists. For a copy of any of the
actual test reports, call 1 (800) 879-3645.
Thermal Performance ASTM C518 Water Vapor Transmission ASTM E96
Fungus Resistance Mil-Std 810B Method 508 Tensile Strength
Pliability Test
Product Standards: Resistance to fungi or bacteria: Reflectix
®
does not promote the growth of fungi or bacteria.
R
Reflectix,Inc.
  • Page 1 1
  • Page 2 2

Reflectix DBWEF48050 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI