Fujitsu UTY-ABGXZ1 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Fujitsu UTY-ABGXZ1 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTRUCTION MANUAL
INSTALLATION •SETTINGOPERATING
UTY-ABGXZ1 Ver. 3.0
BACnet
®
Gateway
for VRF System
PART NO. 9708568010-13
2
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
LICENSE AGREEMENT
For
“BACnet
®
Gateway for VRF System”
IMPORTANT-READ CAREFULLY
This “BACnet
®
GATEWAY for VRF SYSTEM” License Agreement (“LICENSE AGREEMENT”) is a legal agreement between
you and Fujitsu General Limited (“FGL”) for the use of VRF BACnet
®
GATEWAY products consisting of computer software and
online, electronic and/or printed documentation (collectively “SOFTWARE PRODUCT” or “SOFTWARE”). By installing, copy-
ing, or otherwise using the SOFTWARE PRODUCT, you accept to be bound by all of the terms and conditions of this LICENSE
AGREEMENT. If you do not agree to any of the terms and conditions of this LICENSE AGREEMENT, you shall not use the
SOFTWARE PRODUCT and shall promptly return the SOFTWARE PRODUCT to the place where you have obtained it.
COPYRIGHT AND OWNERSHIP.1.
The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties as well as other intellec-
tual property laws and treaties. The SOFTWARE PRODUCT is licensed to you, not sold. FGL owns the title, copyright,
and other intellectual property rights in the SOFTWARE PRODUCT.
GRANT OF LICENSE.2.
FGL hereby grants you the limited, non-exclusive and non-transferable rights to use the SOFTWARE PRODUCT only for
the purpose of controlling the VRF air-conditioning system products (VRF) provided you comply with all terms and condi-
tions of this LICENSE AGREEMENT. You may copy the SOFTWARE PRODUCT solely for backup or archival purposes.
DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS.3.
LIMITATIONS ON REVERSE ENGINEERING, DECOMPILATION, AND DISASSEMBLY.(1)
You shall not modify, alter, reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT. You shall not
alter or remove any copyright, trademark or other proprietary notice of FGL from the SOFTWARE PRODUCT.
NO RENTAL, LEASE AND TRANSFER.(2)
You shall not rent, lease or transfer the SOFTWARE PRODUCT to any person and/or entity (-ies).
TERMINATION.(3)
Without prejudice to any other rights, FGL may terminate this LICENSE AGREEMENT if you fail to comply with any
terms and conditions of this LICENSE AGREEMENT. In such an event, you shall promptly return all originals and
copies of the SOFTWARE PRODUCT to FGL.
INSTALLATION AND USE OF SOFTWARE PRODUCT.4.
You may install and use the enclosed SOFTWARE PRODUCT on a single computer under one of the operating environ-
ment identied in the documentation accompanying the SOFTWARE. You shall not network the SOFTWARE or otherwise
use it on more than 1 computer at the same time. The infrastructure necessary to use the SOFTWARE PRODUCT (PC,
accessories, etc.) shall be prepared separately by you.
NO WARRANTY.5.
FGL EXPRESSLY DISCLAIMS ANY WARRANTY FOR THE SOFTWARE PRODUCT. THE SOFTWARE PRODUCT IS
PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, WITH-
OUT LIMITATION, STATUTORY WARRANTIES, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
NON-INFRINGEMENT OF THIRD PARTY’S RIGHTS. THE ENTIRE RISKS ARISING OUT OF USE OR PERFORMANCE
OF THE SOFTWARE PRODUCT REMAIN WITH YOU. HOWEVER, IF YOU NOTIFY FGL OF PHYSICAL DEFECT OF
THE MEDIA CONTAINING SOFTWARE WITHIN (90) DAYS FOLLOWING YOUR RECEIPT OF THE SOFTWARE PROD-
UCT, FGL WILL REPLACE THE DEFECTIVE MEDIA WITH NEW MEDIA.
3
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
LIMITATION OF LIABILITY.6.
IN NO EVENT SHALL FGL BE LIABLE TO YOU OR TO ANY THIRD PARTY FOR ANY DIRECT OR INDIRECT DAMAG-
ES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFIT, BUSINESS
INTERRUPTION OR LOSS OF BUSINESS INFORMATION, DAMAGES ARISING OUT OF DATA OR INFORMATION
DERIVED FROM OR BASED ON THE ELECTRICITY CHARGE APPORTIONMENT FUNCTION IN THE SOFTWARE
OR ANY OTHER PECUNIARY LOSS), ARISING OUT OF THE USE OR INABILITY TO USE THE SOFTWARE , EVEN IF
FGL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
ENTIRE AGREEMENT.7.
This LICENSE AGREEMENT (including any addendum or amendment to this LICENSE AGREEMENT included with
the SOFTWARE PRODUCT) is the entire agreement between you and FGL relating to the SOFTWARE PRODUCT and
supersedes all prior contemporaneous oral or written communications, proposals and representations with respect to the
SOFTWARE PRODUCT or any other subject covered by this LICENSE AGREEMENT.
INDEMNITY.8.
You agree to indemnify and hold FGL, and its subsidiaries, afliates, ofcers, agents, co-branders or other partners, and
employees, harmless from any damage, claim or demand, including without limitation reasonable attorneys’ fees, made
by any third party due to or arising out of use of the SOFTWARE PRODUCT.
GOVERNING LAW AND JURISDICTION.9.
This LICENSE AGREEMENT is governed by the laws of JAPAN. You and FGL hereby irrevocably consent to the exclu-
sive jurisdiction and venue in the Tokyo District Court and other higher courts having jurisdiction in Japan for the settle-
ment of disputes arising under or in connection with this LICENSE AGREEMENT.
LANGUAGE OF AGREEMENT.10.
This LICENSE AGREEMENT shall be agreed based on the English language. The text in order language is made for
reference purpose only and if there are any discrepancies between the English text and the text in other language, the
English text shall prevail.
4
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Contents
1. Usage Precautions ·····································································································6
1-1 Precautions When Using the BACnet
®
Gateway ························································6
2. How To Use This Manual ·····························································································8
2-1 Manual Composition ····························································································8
Introduction
3. Overview················································································································· 10
3-1 Features ········································································································· 10
4. Materials To Be Prepared Beforehand········································································· 11
5. Software License ····································································································· 12
Installation
6. Installation ·············································································································· 14
6-1 Installation Flow ································································································ 15
6-2 Hardware Installation (Transmission Adaptor) ························································· 16
6-2-1 Transmission Adaptor Installation ·············································································16
6-2-2 Wiring and Turning on the Units Power ······································································18
6-3 Software Installation ·························································································· 19
6-4 Software Uninstallation ······················································································ 30
6-4-1 BACnet
®
Gateway Uninstallation ··············································································31
6-4-2 WIBU-KEY Driver Uninstallation ·············································································· 32
6-4-3 Microsoft
®
SQL Server
®
Uninstallation ······································································ 34
Settings
7. Basic Settings ········································································································· 36
7-1 When Starting for the First Time ··········································································· 36
7-2 “Selection of Unit Data Acquisition Method” ···························································· 38
7-3 "Login Setting" ································································································· 38
7-4 “Initial Setting” ·································································································· 39
7-5 “Adaptor Setting” ······························································································ 42
7-6 “Unit Registration” ····························································································· 43
7-7 “Description Property Setting” ·············································································· 46
7-8 “Change Password” ··························································································· 47
7-9 “Display Language Setting” ················································································· 48
7-10 “License Manager” ···························································································· 49
7-11 “Monitoring Unit Setting” ····················································································· 50
5
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
8. Electricity Charge Apportionment (ECA) Setting ·························································· 52
8-1 Basic Setting Flow ···························································································· 52
8-2 Overview ········································································································· 53
8-3 “Model Name and ECA Parameter Setting” ···························································· 56
Operation
9. Operation ················································································································ 58
9-1 Starting and Ending the BACnet
®
Gateway ····························································· 58
9-2 Main Screen ···································································································· 60
9-3 “Data Import/Export” ·························································································· 62
9-3-1 “Unit List (EDE) Export” ························································································· 62
9-3-2 “All Data Import” ·································································································· 63
9-3-3 “All Data Export” ·································································································· 64
9-4 “View” ············································································································· 65
9-5 “Control” ········································································································· 67
9-5-1 “Operation Setting”······························································································· 67
9-5-2 “Device Communication Disable ············································································· 68
9-5-3 “Device Communication Disable_Initiation” ································································ 69
9-5-4 “Device Communication Enable” ············································································· 70
9-5-5 “Out of Service” ····································································································71
9-6 “Error” ············································································································ 72
9-6-1 Displays “Error Information”···················································································· 72
9-6-2 Displays “Error History” ························································································· 73
9-7 “Help” ············································································································· 73
9-7-1 Displays “Manual” ································································································ 73
9-7-2 Displays “Interface Specication Document” ······························································ 74
9-7-3 Displays Application “Version Information” ································································· 74
Appendix
10.ProductSpecications ····························································································· 76
10-1 Operating Conditions ························································································· 76
11. Error Code Table ······································································································ 77
12. FAQ ························································································································ 78
12-1 General ·········································································································· 78
12-2 Trouble Shooting BACnet
®
Installation ··································································· 81
Microsoft*
®
and Windows
®
are registered trademarks of Microsoft Corporation in the United States.
Adobe*
®
Reader
®
are registered trademarks of Adobe Systems Incorporated in the United States.
Intel*
®
,Pentium
®
and Celeron
®
are registered trademarks of Intel Corporation or its subsidiaries in the United States.
ECHELON*
®
, LONWORKS
®
, and the Echelon logo are trademarks of Echelon Corporation registered in the United
States and other countries.
BACnet*
®
is a registered trademark of the American Society of Heating, Refrigerating and Air-Conditioning Engineers,
INC (ASHRAE).
XLON*
®
is a registered trademark of DH electronics GmbH.
Portions of this software ©2001-2017 PolarSoft Inc.*
6
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Usage Precautions1.
Precautions When Using the BACnet1-1
®
Gateway
Please read and agree to the LICENSE AGREEMENT FOR “BACnet1.
®
Gateway” at the beginning
of this manual before using the BACnet
®
Gateway.
Please conrm that the PC for the BACnet2.
®
Gateway meets the operating condition of the “Product
Specications” described in the Appendix of this manual.
Please read and fully understand this manual before using the BACnet3.
®
Gateway.
Be careful not to shutdown or turn off the power supply of the PC or unplug its transmission adap-4.
tor. Do not terminate the BACnet
®
Gateway program unless necessary. Otherwise, normal op-
eration of the BACnet
®
Gateway may not be performed.
To ensure continuous normal operation of this software,set the PC so that it would not go into an 5.
energy saving mode such as standby mode, sleep mode or execute hibernation. If the PC goes
into a standby, sleep mode or execute hibernation, this software may not function properly. The
method for releasing the energy saving or hibernation of the PC depends on the Windows ver-
sions. For windows
®
7, right click the desktop to select "Personalize" and click "Screen Saver"
icon to select "Change power settings". Check "Power saver" in the "Preferred plans" and select
"Change plan settings" to set "Never".
This product and accessories are not reissued. Keep and handle them with great care after in-6.
stalling.
BACnet7.
®
Gateway programs perform schedules, operation recording and electricity apportion-
ment data control based on date and time set in the personal computer. Adjust date and time pe-
riodically and by a small amount. Changing date and time may affect the functions listed above.
When the date/time of the PC running BACnet
®
Gateway is adjusted to roll back in time, the data
collected for the electricity charge apportionment for that period will be deleted and be newly col-
lected. When the date/time is adjusted to roll forward in time, there will be no data for that period.
Such cases will result in incorrect calculation results for the electricity charge apportionment so
the user should be careful when adjusting date/time for the PC.
When program execution environment of Windows8.
®
is corrupted or abnormal, or if other software
is installed or running on the same PC, operation of BACnet
®
Gateway may be interfered and
may not install or run properly. It is usually extremely difcult to detect such conditions, if it oc-
curs. It is recommended that BACnet
®
Gateway be installed on a new PC, dedicated for the use
of BACnet
®
Gateway.
BACnet9.
®
Gateway product is provided with software, drivers, components listed below. If the
same kind of software, drivers, components with different version is installed on the same PC,
BACnet
®
Gateway may not install or run properly.
Microsoft(1)
®
SQL Server
®
Express
OpenLDV (U10 USB Network Interface driver)(2)
WIBU-KEY driver(3)
This product may be updated without prior notice. If by chance you encounter any trouble with 10.
this product , check with your service personnel for updates.
7
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
When Anti-Virus software is running, an error may occur in this software. 11.
Set the Anti-Virus software to exclude this software from being monitored.
Please refer to your Anti-Virus software manual on how to do this.
8
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
How To Use This Manual2.
Manual Composition2-1
This manual is composed of 5 sections.
Introduction
Installation
Settings
Operation
Appendix
Before installing the software, read the Introduction rst and check the Overview of the BACnet
®
Gateway
and the notes and cautions.
When installing the BACnet
®
Gateway to the PC, read the Installation and Settings sections. Complete
installation to the PC in accordance with the procedure described.
When performing operations related to various functions of the BACnet
®
Gateway after installation, refer to
the relevant parts of the operation section.
The Appendix is made up of product specications, error code table, and FAQ. Read them as required.
Interface Specication document is also available and should be referred to along with this manual.
Introduction
3. Overview
4. Materials To Be Prepared Beforehand
5. Software License
Introduction
10
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Introduction
3. Overview
3-1 Features
=
VRF System 0
BACnet
®
Operator
Workstation (B-OWS)
VRF System 1
.
.
.
.
(Max. 4 VRF Systems)
Echelon
®
U10
USB network
interface (eld
supply)
PC Hardware
(eld supply)
BACnet
®
/IP
BACnet
®
Gateway
(UTY-ABGXZ1)
USB port
LAN port
Lighting
facilities
Security
system
Automatic re
alarm interface
Ventilation
system
BACnet
®
Gateway for
each system
VRF network USB Ethernet
Echelon
®
U10
USB network
interface (eld
supply)
Echelon
®
U10
USB network
interface (eld
supply)
Echelon
®
U10
USB network
interface (eld
supply)
BACnet
®
Specication of UTY-ABGXZ1
•ANSI / ASHRAE Standards 135-2012
•BACnet
®
Application Specic Controller (B-ASC)
•BACnet
®
/ IP over Ethernet
BACnet
®
Gateway
VRF system Operator
Workstation
The maximum number of connecting systems
VRF System 4 systems
For the numbers of the Units that can connect with 1
VRF System, Indoor and Outdoor Units are up to 400
units and up to 100 units respectively.
VRF System Address: *
The numbers from 0 to 3, which are assigned to each VRF System in the BACnet
®
Gateway.
11
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Introduction
Materials To Be Prepared Beforehand4.
Materials necessary at installation
U10 USB Network Interface (adaptor with connection to VRF network work nished)
Administrator ID and password for Windows login (arbitrarily decided by the user. 2 byte characters can-
not be used.)
BACnet
®
Gateway setup media (For details, see the next page.)
IP Address (Fixed IP address is recommended.)
When number of USB ports for WIBU-KEY and U10 USB Network Interface are
insufcient;
USB hub
Setupmediaconguration(Reference)
Manual
BACnet
®
Gateway Manual.pdf
(PDFleforthismanual)
+InterfaceSpecication.pdf
LicenseAgreement LicenseAgreement.pdf
ReadMeFirst.txt
Read before installing the software application.
ISSetupPrerequisites
Tools
OpenLDV
Driver for U10 USB Network Interface
When the Driver for U10 USB Network Interface is installed, execute it.
WibuKey
Driver for WIBU-KEY
This software is necessary to use WIBU-KEY
It is usually installed automatically when BACnet
®
Gateway is installed to
the PC.
When the driver for WIBU-KEY is installed manually, execute it.
setup.exe
Install the BACnet
®
Gateway to the PC.
Execute the setup.exe to install.
12
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Introduction
Software License5.
What is software license?
The software license means the use acceptance of this product in the agreed-upon License Agreement.
One software license is provided as "License" stored in WHITE-USB-KEY for each purchased product.
The license varies depending on the product.
WHITE-USB-KEY
License
BACnet Gateway
“License” stored in WHITE-USB-KEY can be used by inserting WHITE-USB-KEY in PC as it is or moved
into PC by using “License Manager for VRF System”. Refer to “License Manager” manual for details.
License Manager for VRF System” is installed together at the time of BACnet Gateway installation.*
BACnet Gateway
When used by inserting “License”
stored WHITE-USB-Key into PC as it
is. (Status at the time of purchase)
When used by moving “License”
from WHITE-USB-KEY into PC
6. Installation
Installation
14
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Installation6.
This section describes the procedure when installing the BACnet
®
Gateway software to the PC which con-
nects directly to the VRF network. The PC communicates directly with the indoor and outdoor units.
The PC and VRF network are connected by a Transmission Adaptor (U10 USB Network Interface).
This section also describes how to uninstall the software when BACnet
®
Gateway software becomes un-
necessary and also, how to reinstall the installed software due to software upgrading or other reasons.
15
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Installation Flow6-1
Installation/Setting Flow
6-2 Hardware Installation
6-3 Software Installation
Microsoft
®
.NET Framework
Microsoft
®
SQL Server
®
Express
BACnet
®
Gateway
WIBU-KEY Setup
License Manager Setup
7 Basic Setting
WARNING!
BACnet
®
Gateway is tested to install and operate under new Windows environment. When
program executional environment of Windows is corrupted or abnormal, or other softwares
that interfere with the operation of BACnet
®
Gateway is installed or running, BACnet
®
Gate-
way may not install or run properly. It is usually extremely difcult to detect such conditions, if
it occurs.
BACnet
®
Gateway product is provided with softwares, drivers, components listed below. If the
same kind of softwares, drivers, components with different version is installed on the same
PC, BACnet
®
Gateway may not install or run properly.
Microsoft(1)
®
SQL Server
®
Express
Open LDV (U10 USB Network Interface driver) (2)
WIBU-KEY-driver(3)
Do not insert U10 USB network interface adaptor to the USB slot of the PC BEFORE its driver
is installed.
Do not turn on the power of indoor/outdoor units until all installation work is completed.
Do not insert WIBU-KEY to the USB port of the PC until instructed.
5
16
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Hardware Installation (Transmission Adaptor)6-2
6-2-1 Transmission Adaptor Installation
UTY-ABGXZ1
BACnet
®
Gateway
Transmission Adaptor
(U10 USB Network Interface)
VRF System 3
VRF System 2
VRF System 1
VRF System 0
USB cable
The BACnet
®
Gateway can connect up to 4 VRF Systems. Since 1 Transmission Adaptor connects to
1 system, up to 4 Transmission Adaptors are connected.
Following chart shows the detail of the U10 USB Network Interface Adaptor. These adaptors are not includ-
ed in the BACnet
®
Gateway product and must be procured in advance.
Name & Shapes Q’ty Remark
Transmission Adaptor (U10 USB Network Interface
-TP/FT-10 Channel)
(Field Supply)
Procure the necessary number
in accordance with the number
of connection systems.
Model : 75010R
(Echelon
®
Corporation)
It is necessity that set Transmission adaptor respectively because of the S/V series and V-II or later (V-II/
J-II/VR-II/J-IIS/V-III/J-III) series can not be connected to the same communication line.
17
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Installing U10 USB Network Interface Adaptor
To use this product, turn on the power of the PC and install necessary drivers/software for this product (BE-
FORE connecting it to any USB port ), following the ***QUICK START*** enclosed with this product.
When using multiple U10 USB Network Interface adaptors, conrm in advance, which U10 USB
Network Interface adaptor connects to which VRF Network (Attach labels to the U10 USB Network
Interface adaptors If possible). These information will become necessary during the setup procedure
of BACnet
®
Gateway (You will be required to specify which U10 USB Network Interface adaptor corre-
sponds to which VRF network).
1
2
3
4
VRF0
LON1
LON2
LON3
LON4
VRF1
VRF2
VRF3
Keeping a record of a table such as shown below is recommended.
LON No. Adaptor No. VRF System No.
LON1 Adaptor 1 VRF 0
LON2 Adaptor 2 VRF 1
LON3 Adaptor 3 VRF 2
LON4 Adaptor 4 VRF 3
Note. “LONx” is used to identify U10 USB Network Interface adaptor. LON numbers are given in the or-
der they are inserted to a PC for the rst time and basically, never changes, even if you change USB slot
afterwards.
Connect the U10 USB Network Interface adaptor to the personal computer USB port.
When there are multiple U10 USB Network Interface adaptors, connect each U10 USB Network Inter-
face adaptor in the order of its LON number.
18
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Wiring and Turning on the Units Power6-2-2
Once the wiring has been installed, the power can be turned on. Follow the procedure below for turning on
the power.
Connect VRF network cables to the corresponding U10 USB Network Interface adaptors.
Turn on the power for all connected indoor units.
Turn on the power for all connected outdoor units.
Make sure that USB equipment (USB hub, etc.) that this product is connected to, is not overloaded (power sup-
plied thru the interface does not exceeds the maximum limit).
Note
Turn on the power for BACnet
®
Gateway PC, if it is not yet turned on.
19
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Software Installation6-3
The following software is installed here.
Microsoft
®
.NET Framework
Microsoft
®
SQL Server
®
Express
BACnet
®
Gateway
WIBU-KEY driver
License Manager
Before starting the installation of this product, check each of the followings.
Install Adobe
®
Reader
®
(Ver. 9.0 or later) prior to the installation. (Adobe
®
Reader
®
does not come with
this product).
Remove all program as described in “6-4 Software Uninstallation” , if you have the same or previous
version of BACnet
®
Gateway.
Do NOT insert WIBU-KEY (Software protection key) enclosed with this product to the PC until product
installation is completed.
You are required to login to the computer as Administrator (or equivalent) to the PC to install this prod-
uct. (Enter the ID with single-byte characters.)
Stop all running programs before you start the installation.
If Anti-Virus software product is installed, temporarily disable the software during the installation of this
product.
Execute setup.exe in the root folder on the BACnet
®
Gateway setup media.
Microsoft
®
.NET Framework
.NET Framework is installed automatically if it is not already installed.
Microsoft
®
SQL Server
®
Express
Microsoft
®
SQL Server
®
Express is installed automatically if it is not already installed.
Select the language.
Select the desired language.
Click the “OK”button.
20
Copyright© 2010-2017 Fujitsu General Limited. All rights reserved.
Installation
Install .NET Framework using the chosen method (for Windows 8.1 (or later)).
This screen will not be displayed for Windows other than Windows 8.1 (or later). Even for Windows 8.1
(or later), it will not be displayed if .NET Framework has already been installed.
Install Online (when the PC is connected to internet)
Select "Install from Internet" and click “Install” button.
.NET Framework 3.5 will be downloaded from Microsoft site and will be installed.
Install Ofine (when the PC is not connected to internet)
When the PC is not connected to the internet, Windows 8.1 (or later) installation media is required to
install .NET Framework 3.5. Please have the media ready before continuing the following steps.
If you have Windows 8.1 (or later) installation DVD, select "Install using Windows 8.1 (or later) DVD
installation media". If you have other types of Windows 8.1 (or later) installation media, check that the
“sxs” folder that holds the .NET Framework components exists within that media, and select ”Specify
the folder with .NET Framework installation les”.
Install using Windows 8.1 (or later) DVD installation media
Insert Windows 8.1 (or later) installation DVD to the DVD drive.
Select that drive and click “Install” button.
When the installation of .NET Framework 3.5 completes, a message “Set the System Tool DVD
installation media” is displayed. Insert the BACnet
®
Gateway media again.
Specify the folder with .NET Framework installation les
Specify the "sxs" folder and click “Install” button.
(The “sxs“ folder is where the .NET Framework components are stored).
Ex. D:\windows8\sources\sxs
Installation of .NET Framework 3.5 requires few minutes to complete. Do not operate the screen until
the installation is completed.
Note
/