Southbend CE342S User manual

Type
User manual

This manual is also suitable for

southbend
A MIDDLEBY COMPANY
OWNER'S MANUAL
INSTALLATION
USER'S GUIDE
ELECTRICALLY OPERATED STEAM GENERATOR
MODELS: CE-24S, CE-324S, CE-336S, CE-342S
These instructions should be read thoroughly before attempting installation. Set up,
installation and Performance Check should be performed by a qualified service technician.
The Manufacturer, Southbend (1100 Old Honeycutt Rd.. Fuquay-Varina, North Carolina
27526), informs you that unless the installation instructions for the above described
Southbend product are followed and performed by a qualified service technician, (a person
experienced in and knowledgeable concerning the installation of commercial gas and/or
electrical cooking equipment) then the terms and conditions of the Manufacturer's Limited
Warranty will be rendered void and no warranty of any kind shall apply.
If the equipment has been changed, altered, modified or repaired by other than a qualified
service technician during or after the 12-month limited warranty period, then the
manufacturer shall not be liable for any incidental or consequential damages to any person
or to any property which may result from the use of the equipment thereafter. Some States
do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion thereto may not apply to you.
In the event you have any question concerning the installation, use, care, or service of the
product, write Customer Service Department. Southbend Corporation. 1100 Old Honeycutt
Rd., Fuquay-Varina, North Carolina 27526.
INSTALLATION AND OPERATION
MANUAL
ELECTRIC BOILERS
CE324
CE336
CE342
MODELS:
CE24
southbend
A MIDDLEBY COMPANY
1100
Old Honeycutt Road
Fuquay
-
Varina, NC
(919) 552
-
9161
FAX
(919) 552
-
9798
(800) 348
-
2558
INSTALLATION AND OPERATION
It is recommended that this manual be read thoroughly and that
all instructions be followed carefully. This manual should be retained for future reference.
DO NOT ATTEMPT TO OPERATE THIS UNIT IN THE EVENT OF A POWER FAILURE.
ADEQUATE CLEARANCES MUST BE MAINTAINED FOR SAFE AND PROPER OPERATION.
I N D E X
DESCRIPTION PAGE
INDEX 1
INSTALLATION AND SERVICE CONNECTIONS 2
INSTALLATION INSTRUCTIONS 3
OPERATION INSTRUCTIONS 4
PERIODIC MAINTENANCE 5
TROUBLESHOOTING 6
DESCALING 7
WATER QUALIIY STATEMEHT
WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR APPLIANCE. IF YOU ARE UNSURE OF
WATER QUALITY. CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE THE WATER ANNALYZED. YOUR
WATER SUPPLY MUST BE WITHIN THESE GENERAL GUIDE LINES:
TOTAL DISSOLVED SOLIDS
LESS THAN 60 PPM
TOTAL ALKALINITY
LESS THAN 20 PPM
SILICA
LESS THAN
13
PPM
CHLORINE
LESS THAN 30 PPM
pH FACTOR
7.0
-
8.5
WATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
INSTALLATION AND SERVICE CONNECTIONS
SERVICE CONNECTIONS
CW Cold Water supply. Provide 3/8"
copper tube.
EC Field Wiring Electrical Connection
to be as specified on Electrical
Rating Label which is according
to Customer's Order.
ST Steam take-off locations to supply
steam to adjacent units if desired.
DR Appliance drain is 2" pipe size.
Provide open air gap type drain.
Model
Capacity A B C D E F G H J K L M N
inches 24" or 36" wide by 33" 7 5-1/2 15 22 18 4-1/2 11 4-1/4 13 11 2 3 31 CE324
CE 336
CE 342
mm 610 or 914 mm x 838mm 780 145 380 560 455 110 280 705 330 280 50 75 787
As continued product Improvement is a policy of Crown, specifications are subject to change without notice.
INSTALLATION INSTRUCTIONS
Ideally an exhaust system should be located directly above the appliance to exhaust steam and heat generated by the
appliance.
Set the unit in place and level using a spirit level.
Ascertain that a floor drain (open gap) is convenient to the appliance drain.
Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
Remove appliance and drill holes in locations marked on floor and insert proper anchoring devices.
Set unit back in position and re-level left to right and front to back. NOTE: If unit has factory mounted upper cooking
section then appliance should be elevated on the right 1/16" to 1/8" to assure proper compartment drainage.
Bolt and anchor appliance securely to the floor.
Seal bolts and flanged feet with Silastic or equivalent compound.
Make service connections as indicated.
OPERATION INSTRUCTION
Turn on water and power supply to appliance. Open door of cabinet and turn on Power Switch. Pilot light will come ON
and water will begin to enter boiler. Once water level has reached the proper operating level as indicated on water gauge
glass the heating elements will be energized and heat the water. When steam pressure has reached 14.5 PSI the
elements will de-energize and cycle on and off between 12-14.5 PSI. The boiler is now ready for steam generation.
Shut Down
Turn off power switch, open manual drain valve, if unit is equipped with automatic blowdown valve, it will open and drain
the boiler.
PERIODIC MAINTENANCE
Notice:
As a safety precaution, disconnect the power supply during cleaning or servicing.
1. Water level control should be opened at least once a week to blowdown sediment and scalant.
2. Observe that the water in gauge glass is clean and clear. Extreme murkiness in water indicates inadecpiate
water quality.
3. Safety valve should be tripped during operation once a week to assure that it functions properly.
4. Keep all exposed cleanable areas of unit clean at all times.
CAUTION:
TAKE EXTRA CAUTION WHEN BLOWING DOWN WATER LEVEL CONTROL OR TRIPPING SAFETY
VALVE AS EXTREME HOT WATER AND LIVE STEAM ARE PRESENT.
TROUBLESHOOTING
Water not being supplied to Boiler
1. Water supply is "OFF".
2. Defective water fill solenoid.
3. Water level control clogged or defective, unable to operate fill valve.
4. Check drain valve is closed.
5. Supply water pressure too low.
Automatic Blowdown valve does not drain
1. Defective Blowdown valve.
2. Heat exchanger build up of scalant clogging
drain lines and valve.
Boiler achieves pressure slower than normal
1. Heavy build up of lime on elements.
2. Loose element connections.
Safety Valve blows
1. Defective safety valve.
2. Pressure too high, pressure switch requires adjustment (lower) or may be defective.
AT LEAST TWICE A YEAR HAVE AM AUTHORIZED SERVICE PERSON CLEAN AND ADJUST THE UNIT FOR
MAXIMUM PERFORMANCE.
DESCALING BOILER
It is recommended that the boiler should be checked every 90 to 120 days for scale build up. Regular maintenance
should be carried out at this time.
1. With Boiler empty, close manual blowdown valve. If appliance is equipped with Automatic Blowdown, turn water
supply Off to appliance. Turn power switch ON this will energize and close Blowdown valve.
2. Remove 3/4" pipe plug from fitting on left front of boiler.
3. Insert appropriate hose or tube through fitting and pour in (1/2) half gallon (U.S.) of CLR Descaling solution.
Or use the Optional Deliming assembly DPA-1 available from your dealer.
4. Replace 3/4" pipe plug securely.
5. Open water supply to appliance allowing water to fill boiler
to required level.
6. Let appliance cycle, allow two hours for descaling and cleaning. DO MOT TORN ON STEAM.
7. Open both the blowdown and low water level control valves for complete drainage and close both valves.
8. Turn appliance switch ON. When boiler is completely filled turn power switch OFF, this will rinse and drain boiler.
Appliance with Manual blowdown valve must be opened to drain.
9. Complete Step 8 twice to assure boiler is completely rinsed.
10. Appliance is now ready for use.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Southbend CE342S User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI