ROVARY RV2000P User manual

Category
Measuring, testing & control
Type
User manual
CO2 Monitor
Model: RV2000P Manual/Betriebsanleitung
Deutsch
English
Inhoud
Getting started
-------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------- 2
Packing list
-------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------- 2
Features at a glance
-------------------------------------------------------------------------------------------------------------------------------
-------------------- 2
Overview
-------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------- 3
General operation and settings
-------------------------------------------------------------------------------------------------------------------------
5
Operating instructions
-------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------
4
LCD Screen
-------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------- 6
Trend chart display
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------- 7
Max/Min ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 8
Main menu functions
-------------------------------------------------------------------------------------------------------------------------------
----------------------- 9
-------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------
16
Switching on/off
-------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------14
Power source 15
Specifications
-------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
Air quality
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------1
Manual EN
CO2 value displayed in PPM (Parts Per Million)
Air quality
1
Serious pollution
Expect harmful
health consequences >1200
Normal air
Complaints about odours,
fatigue and headaches
possibly
>800
<1200
<800
Fresh air
Healthy, normal
(outdoor) air
2
Manual EN
Getting started
Packing list
Rovary CO2- Meter
USB cable for power supply
User Manual
Adapter
Features at a glance
Large Screen & Rechargeable
Touch button operation
15° Bevelled design, easy to read
NDIR sensor with long service life
Audible alarm
Graph with variable time - zoom levels
CO2/RH/Temperature monitor
Auto calibration and manual calibration
Max/Min value display in specified time
Thank you for purchasing our
RV2000P CO2 monitor! This product is used
to monitor the CO2 concentration, the RH (humidity)
and the temperature. It allows you to ensure the air quality indoors.
Note: The buttons do not have to be pressed,
the monitor already responds when you place your
finger on the button. If you press the buttons too
hard, the device will not function properly.
3
Overview
Drawing sketch and parts list
Description
Front panel
Home screen
Button
Button
Button
Button
Power indicator
High level
Description
Good level
Low level
USB port
Hole for rope
Hole for screws
On/Off Button
Label
Hole for sensors
4
Operating instructions
1. When you take the device out of the box for the first time, connect it to the USB cable provided.
2. To turn on the CO2 meter, press the pin as shown in the photo. The pin should remain pressed.
3. When the meter is successfully connected, the power indicator and the 3 LEDs will blink one after
the other, one by one.
4. The main display will show a countdown from 10, the meter is ready to use. No initial setup or
calibration is required.
5. The Rovary RV2000P meter is rechargeable and can also be used without a cable.
Please note! Make sure that
the pin is fully pushed in
otherwise the meter will not work.
Manual EN
-
-
-
-
-
-
-
-
5
General operation and settings
Use the supplied USB cable to connect and turn on the device.
Once the connection is complete, your device is ready to use.
Use the buttons and
To restore the factory settings, press and hold for 3 seconds until you hear a soundsignal.
Press to call up the main menu. To select the function, press / button.
Select to switch to the human And plant modus.
Select to set the high/low alarms for human and plant to change.
to switch the alarm on and switch off the sound .
to switch between the temperature units °C and °F.
to scale the timeline and CO2/RH/TEMP. The trend graph shows
the history of one of the three parameters.
Select
Select
6
LCD display
Name
Plant mode
Human mode
Audible alarm on/off
CO2 measurement
Name
RH value
Main menu
CO2/RH/TEMP graph
Max. value of the graph
Minimum value of the chart
Time per division - indicates the
time span of the graph
Manual EN
Temperature measurement °C / °F
7
Trend chart display
Press
The graph below shows the past measurements for one of the three parameters (CO2/RH/TEMP)
There are 4 modes that can be toggled using key: CO2, TEMP, RH and Cycle (switches
automatically through CO2/TEMP/RH).
To change the available zoom levels for each parameter (minute/hour/day/week).
Press
Press
Press
Press
Press
Press
Press
Press
8
Below is a table with the available zoom levels for all parameters CO2/RH/Temp and the duration of
each division for the corresponding zoom levels:
Max/Min
There are two numeric indicators in the upper right-hand corner of the display: MAX and MIN. When the
zoom level is changed, the MAX and MIN value will be displayed on the graph of the selected
parameter (CO2, RH and TEMP).
Time per department
Zoom Level (Time range)
1M(minute)
1H(hour)
1D(day)
1W(week)
5sec/div
5m/div
2h/div
0.5d/div
Manual EN
9
The functions of the main menu can be activated by pressing .
By pressing / press, the main menu opens, with an underlined flashing
bar indicating the current selection.
Main menu functions
No pressing of a
button in 1 minute
Press
Press Press
Press
Press
Press
Press
Press
10
To select the function, press the when it is underlined by the flashing
bar. Note that after 1 minute, if nothing is pressed, the main menu will disappear and the device
will return to the normal state.
Function
ALARM
PLANT
Description
Press Main interface
Main interface
Press Press Press
Press
Press Press Press Press
Press
Press
Press
Press
Press
Press
Press Press
When the ALARM display an audible alarm sounds when the CO2 level exceeds the preset
CO2 alarm value;
means MUTE.
Select number 0 to go to human mode. 0 is set as human mode by default, unchanged.
The preset low and high alarms are 800 and 1200 ppm. Enter 'ADV' to adjust them if necessary.
In plant mode, the user can choose between different types of plants for optimal setting
using cycles through 1~9.
/
Manual EN
11
Function
LOG
Description
Press , right
2e column flashes
Press Right 2 ,
e
3e column flashes
This function allows you to view the historical data records.
Press
Press
Press
Press
Press
12
Function
CALI
ºC / ºF
Description
Press for 3 seconds
to hear the buzzing sound
Main menu
Press
Press
Press Press
Press
Press
Press to close
Use this function to switch between Celcius (ºC) and Fahrenheit (ºF) for the temperature display.
Manual EN
Temperature display
(CO2 level display)
Before calibration, run this unit for at least 20 minutes with windows open or in an outdoor environment
with a portable outdoors with a portable battery source to reach an atmosphere of 400 ppm CO2.
Wait until CO2 reading is stable, then follow the above steps for calibration. Leave the
unit for 10 minutes after calibration for normal operation.
13
Function
ADV
Description
Press
Use this function to set high and low alarm values of the human mode (0) and the first
option of the plant mode (1). High and low alarms for options 2-9 in plant mode are not adjustable.
plant mode are not adjustable.
Press
Press
Press
Press
Press
Press
Press
Press
14
Switching on/off
Turn on (ON):
Turn off (OFF):
Turn off the appliance if it will not be used for more than 1 week.
Turn down the switch to activate the monitor, wait 3 minutes for it to
warm up. Flip the switch again to turn the device off.
Manual EN
15
Power source
Connect the USB power supply
Connect the USB cable when the device is
is set to ON.
Battery
Battery indicator
Flat battery: red light lights up continuously (charge the device within 20 minutes to
prevent damage to the battery).
Charging: Red light blinks.
Fully charged: green light is on continuously.
Battery charging
Connect the USB cable when the device is switched ON.
Charging time: 2.5 hours (Charges for an additional 30 minutes after the light switches
from red to green).
Working time: 8-10 hours.
16
Measurement
Operating temperature
Storage temperature
Operation & storage RV
CO2 measurement
Measuring range
Display resolution
Accuracy
Repeatability
Response time
Warm-up time
20ppm at 400ppm
±0.1% of the measurement per °C
<2 min for 63% or <4.6 min for 90% of step changes
<20 seconds
Specifications
32º F - 122º F (0º - 50ºC)
-4 F - 140º F (-20º C - 60º C)
0-95% (non-condensing)
(0-5000)ppm
1 ppm (0-1000); 5ppm (1000-2000); 10ppm) (>2000)
(0~3000)ppm 50ppm +-5% of measurement (take maximum)
(>3000)ppm: +-7% of the measurement
Specifications
Manual EN
Typical test conditions: Ambient temperature: 23 ± 3°C, RH=50%~70%, Altitude= 0~10 meters
Temp. compensation
17
5-95%
5%
1% Main interface display, 0.1% Max/Min display
120*90*35mm
Operating temperature
Display resolution
Response time
RH measurement
Measuring range
Precision
Display resolution
Operating voltage
Dimension
Weight
32'F -195'F (0'C-90'C)
0.1’F (0.1’C)
<20 minutes (63%)
DC (5 0.25)V
+
-
+
-
190g (6.0oz) device only, excluding AC adapter
Temperature measurement
Inhalt
Erste Schritte
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------
Packliste
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------
Produkteigenschaften im Überblick
-------------------------------------------------------------------------------------------------------------------------------
Schematischer Überblick
-------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
Allgemeine Bedienung und Einstellungen
-------------------------------------------------------------------------------------------------------------------------
Betriebsanleitung
-------------------------------------------------------------------------------------------------------------------------------
LCD-Bildschirm
-------------------------------------------------------------------------------------------------------------------------------
Anzeige Trendgrafik
-------------------------------------------------------------------------------------------------------------------------------
Max/Min
-------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
Funktionen Hauptmenü
-------------------------------------------------------------------------------------------------------------------------------
-----------------------
-------------------------------------------------------------------------------------------------------------------------------
Ein-/ausschalten
-------------------------------------------------------------------------------------------------------------------------------
Stromanschluss
Spezifizierungen
-------------------------------------------------------------------------------------------------------------------------------
Luftqualität
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------18
Betriebsanleitung DE
19
19
20
21
22
23
24
25
31
32
33
26
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

ROVARY RV2000P User manual

Category
Measuring, testing & control
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages