D25303DH

DeWalt D25303DH User manual

  • Hello! I am an AI chatbot trained to assist you with the DeWalt D25303DH User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
D25303DH
Dust Extraction System with HEPA Filter
Système de dépoussiérage avec filtre H.E.P.A.
Sistema de extracción de polvo con Filtro HEPA
DeWALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286
(AUG15) Part No. N451310 D25303DH Copyright © 2015 DeWALT
The following are trademarks for one or more DeWALT power tools: the yellow and black color scheme; the “D” shaped
air intake grill; the array of pyramids on the handgrip; the kit box configuration; and the array of lozenge-shaped humps
on the surface of the tool.
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please
read the manual and pay attention to these symbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury.
NOTICE: indicates a practice not related to personal injury which, if not
avoided, may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY DeWALT TOOL,
CALL US TOLL FREE AT: 1-800-4-DeWALT (1-800-433-9258)
WARNING: To reduce the risk of injury, read all of this manual carefully before operating
the attachment. Also refer to the manual of any power tool that will be used with this
attachment.
General Power Tool Safety Warnings
WARNING! Read all safety warnings and all instructions. Failure to follow the
warnings and instructions for this accessory and the power tool may result in electric
shock, fire and/or serious injury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
1) WORK AREA SAFETY
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence
of flammable liquids, gases or dust. Power tools create sparks which may ignite the
dust or fumes.
c) Keep children and bystanders away while operating a power tool. Distractions
can cause you to lose control.
2) ELECTRICAL SAFETY
a) Power tool plugs must match the outlet. Never modify the plug in any way. Do
not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs
and matching outlets will reduce risk of electric shock.
b) Avoid body contact with earthed or grounded surfaces such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is
earthed or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a power tool
will increase the risk of electric shock.
d) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging
the power tool. Keep cord away from heat, oil, sharp edges or moving parts.
Damaged or entangled cords increase the risk of electric shock.
e) When operating a power tool outdoors, use an extension cord suitable for
outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
f) If operating a power tool in a damp location is unavoidable, use a ground fault
circuit interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric
shock.
3) PERSONAL SAFETY
a) Stay alert, watch what you are doing and use common sense when operating a
power tool. Do not use a power tool while you are tired or under the influence
of drugs, alcohol or medication. A moment of inattention while operating power tools
may result in serious personal injury.
b) Use personal protective equipment. Always wear eye protection. Protective
equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection
used for appropriate conditions will reduce personal injuries.
c) Prevent unintentional starting. Ensure the switch is in the off position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or energizing power tools that have
the switch on invites accidents.
d) Remove any adjusting key or wrench before turning the power tool on. A wrench
or a key left attached to a rotating part of the power tool may result in personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This enables
better control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing
and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught
in moving parts.
g) If devices are provided for the connection of dust extraction and collection
facilities, ensure these are connected and properly used. Use of dust collection can
reduce dust-related hazards.
4) POWER TOOL USE AND CARE
a) Do not force the power tool. Use the correct power tool for your application. The
correct power tool will do the job better and safer at the rate for which it was designed.
b) Do not use the power tool if the switch does not turn it on and off. Any power tool
that cannot be controlled with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source and/or the battery pack from the
power tool before making any adjustments, changing accessories, or storing
power tools. Such preventive safety measures reduce the risk of starting the power tool
accidentally.
d) Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power tool’s
operation. If damaged, have the power tool repaired before use. Many accidents
are caused by poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp
cutting edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc., in accordance with these
instructions taking into account the working conditions and the work to be
performed. Use of the power tool for operations different from those intended could
result in a hazardous situation.
5) BATTERY TOOL USE AND CARE
a) Recharge only with the charger specified by the manufacturer. A charger that is
suitable for one type of battery pack may create a risk of fire when used with another
battery pack.
b) Use power tools only with specifically designated battery packs. Use of any other
battery packs may create a risk of injury and fire.
c) When battery pack is not in use, keep it away from other metal objects like paper
clips, coins, keys, nails, screws, or other small metal objects that can make a
connection from one terminal to another. Shorting the battery terminals together may
cause burns or a fire.
d) Under abusive conditions, liquid may be ejected from the battery; avoid
contact. If contact accidentally occurs, flush with water. If liquid contacts eyes,
additionally seek medical help. Liquid ejected from the battery may cause irritation or
burns.
6) SERVICE
a) Have your power tool serviced by a qualified repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
Additional Safety Rules
WARNING: ALWAYS USE SAFETY GLASSES. Everyday eyeglasses are NOT safety
glasses. Also use face or dust mask if cutting operation is dusty. ALWAYS wear certified safety
equipment:
ANSI Z87.1 eye protection (CAN/CSA Z94.3).
ANSI S12.6 (S3.19) hearing protection.
NIOSH/OSHA respiratory protection.
WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known to the State of California to cause cancer, birth
defects or other reproductive harm. Some examples of these chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement and other masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on how often you do this type of work. To
reduce your exposure to these chemicals: work in a well ventilated area, and work with approved
safety equipment, such as those dust masks that are specially designed to filter out microscopic
particles.
Avoid prolonged contact with dust from power sanding, sawing, grinding, drilling,
and other construction activities. Wear protective clothing and wash exposed areas
with soap and water. Allowing dust to get into your mouth, eyes, or lay on the skin may
promote absorption of harmful chemicals.
Do not use without dustbox and/or filter in place.
Do not use the appliance to pick up flammable or combustible liquids, such as gasoline, or
use in areas where flammable or combustible liquids are present.
Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
To avoid spontaneous combustion, empty dust box after each use.
Do not leave dust extractor unattended when battery is installed. Remove battery
pack when not in use and before servicing.
Do not put any objects into the openings. Do not use with any opening blocked; keep
free of dust, lint, hair and anything else that may reduce air flow.
WARNING: Use of this tool can generate and/or disburse dust, which may cause serious and
permanent respiratory or other injury. Although the filter material removes 99.97% of airborne
particles 0.3 microns or greater, the dust extration system may not capture all of the dust
created by the drilling operation. Always use NIOSH/OSHA approved respiratory protection
appropriate for the dust exposure. Direct particles away from face and body.
WARNING: Always wear proper personal hearing protection. Under some conditions
and duration of use, noise from this product may contribute to hearing loss.
COMPONENTS (FIG. 1)
WARNING: Never modify the power tool or any part of it. Damage or personal injury could
result.
A. Dust extraction system
B. Base release buttons
C. Dust collection box
D. Dust collection box release buttons
E. Telescope
F. Depth adjustment button
G. Length adjustment button
H. Dust extraction head
I. Dust brush
J. Side handle
K. Side handle support groove
L. Side handle support locator
M. Dust extractor electrical connectors
N. Rotary hammer electrical connectors
O. Dust collection box filter assembly
P. Dust collection box filter assembly latch
INTENDED USE
Your dust extraction system D25303DH has been designed for the extraction of dust in professional
hammerdrilling in masonry or concrete, and with solid drill bits mounted to the power tool. DO NOT use for
drilling plastic, wood or metal.
This dust extraction system will fit DeWALT 20V Max cordless SDS Plus® hammers DCH253,
DCH254 (TYPE 2 only), DCH273 and DCH274.
WARNING: DO NOT use for drilling plastic, wood or metal.
Recommended power tools to be used with this attachment are available at extra cost from
your local dealer or authorized service center. If you need assistance in locating any power tool,
please contact DeWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286, call
1-800-4-DeWALT (1-800-433-9258) or visit our website www.dewalt.com.
If you have questions or comments, contact us.
Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DeWALT • www.dewalt.com
INSTRUCTION MANUAL
GUIDE D’UTILISATION
MANUAL DE INSTRUCCIONES
DO NOT use under wet conditions or in presence of flammable liquids or gases.
The dust extraction system is an attachment for use with professional power tools.
DO NOT let children come into contact with the tool. Supervision is required when inexperienced
operators use this tool.
ASSEMBLY
WARNING: ALWAYS turn off tool and disconnect the tool from the power source
before making any adjustments or removing or installing attachments or accessories.
Such preventative safety measures reduce the risk of starting the tool accidentally.
Attaching and Removing the Dust Extraction System
TO ATTACH THE DUST EXTRACTION SYSTEM (FIG. 1–3, 5)
WARNING: To reduce the risk of personal injury, ALWAYS operate the tool with the
side handle properly installed and securely tightened. Failure to do so may result in the
side handle slipping during tool operation and subsequent loss of control. Hold tool with both
hands to maximize control.
1. Remove the drill bit, side handle and the depth adjustment rod, if attached to the rotary
hammer.
2. Attach supplied side handle (J) to the hammer.
3. Ensure the base release buttons are depressed and locked in the open position before
attempting to fit the dust extraction system to the rotary hammer.
4. Insert hammer into the extractor, ensuring that both the electrical connectors and side
handle support groove and locator align. The base released buttons will click into the closed
position when hammer is properly seated in the extractor.
TO REMOVE THE DUST EXTRACTION SYSTEM (FIG. 2)
To remove the dust extraction system, press the two extractor base release buttons (B) and lift
the rotary hammer off the duct extraction system.
OPERATION
WARNING: ALWAYS turn off tool and disconnect the tool from the power source
before making any adjustments or removing or installing attachments or accessories.
Such preventative safety measures reduce the risk of starting the tool accidentally.
WARNING: For your own safety, read the tool instruction manual before using any accessory.
Failure to heed these warnings may result in personal injury and serious damage to the tool and
the accessory. When servicing this tool, use only identical replacement parts.
WARNING: Do not use the tool without the filter in place.
Switch
The extraction system automatically starts when the rotary hammer is turned on.
Electronic Switch-off Delay
After turning the rotary hammer off, the extraction system will run for a few seconds longer
to vacuum the remaining dust particles in the internal parts and collect the dust in the dust
collection box.
Setting the Drilling Depth (Fig. 8)
Press the depth adjustment button (F) on top of the front slider and move it to the desired drilling
depth. Release the button.
Adjusting the Drill Length (Fig. 1)
1. Insert the appropriate drill bit. The dust extractor head is designed for bits up to 5/8"
diameter.
2. Hold the dust extraction head (H) against a wall.
3. Push the tool to make the drill bit touch the surface.
4. Press the length adjustment button (G) on top of the back slider and move it to the desired
length. Release the button.
5. Gently withdraw the tool assembly from the wall, taking care that the spring-loaded
mechanism does not release.
Emptying the Dust Collection Box (Fig. 4, 5)
WARNING: ALWAYS use eye protection (CAN/CSA Z94.3). All users and bystanders
must wear eye protection that conforms to ANSI Z87.1.
WARNING: ALWAYS use proper NIOSH/OSHA/MSHA respiratory protection when
performing this procedure.
CAUTION: Do not clean with water or compressed air.
The dust collection box (C) should be emptied as soon as the performance has noticeably
decreased.
1. Press the dust collection box release buttons(D) and pull the dust collection box away
from the dust extraction system. Once the catch mechanism is clear of the dust extraction
system the upper joint will also release allowing the dust collection box to be removed
completely.
2. To empty the dust collection box (C) position it over a suitable container to catch the dust
contained within it. Lift up the assembly release latch(P) to open the dust collection box,
separating the canister from the lid. Gently tapping the dust collection box will encourage
any dust trapped within the filter to also be removed. Once the filter lid and canister are
empty reattach them, ensuring the assembly release latch (P) is securely fastened. Refer to
figure 5.
3. To reattach the dust collection box to the dust extraction system first insert the rounded
profile of the upper joint into the recess on the dust extraction system. Pivot the dust
collection box down so that the release buttons click back into place. Refer to figure 4.
MAINTENANCE
WARNING: ALWAYS turn off tool and disconnect the tool from the power source
before making any adjustments or removing or installing attachments or accessories.
Such preventative safety measures reduce the risk of starting the tool accidentally.
Your dust collector has been designed to operate over a long period of time with a minimum
of maintenance. Continuous satisfactory operation depends on proper tool care and regular
cleaning. Empty the dust extractor periodically or when the performance has noticeably
decreased.
Replacing the Dust Collection Box Filter Assembly
(fig. 4, 5)
WARNING: Wear approved eye protection and approved dust mask when performing this
procedure.
NOTE: The filter should be replaced after every 100 to 120 cycles of use.
1. Press the dust collection box release buttons(D) and pull the dust collection box away
from the dust extraction system. Once the catch mechanism is clear of the dust extraction
system the upper joint will also release allowing the dust collection box to be removed
completely.
2. Lift up the release catch(P) to open the dust collection box, separating the box from the
assembly.
3. Discard dust collection box filter assembly (O) and replace with approved DeWALT service
part.
4. Reattach the dust collection box to the dust extraction system first insert the rounded profile
of the upper joint into the recess on the dust extraction system. Pivot the dust collection box
down so that the release buttons click back into place.
Replacing the Dust Brush (Fig. 10)
WARNING: ALWAYS use eye protection (CAN/CSA Z94.3). All users and bystanders
must wear eye protection that conforms to ANSI Z87.1.
WARNING: Use of this tool can generate and/or disburse dust, which may cause serious and
permanent respiratory or other injury. Always use NIOSH/OSHA approved respiratory protection
appropriate for the dust exposure.
The dust brush will wear during use and will need to be replaced.
1. Push the snap-fit (S) at the back of the extraction head, and pull it out of the head holder.
2. Use a screwdriver to remove the dust brush (I) out of the extraction head.
3. Replace the dust brush with a new one.
4. Make sure that the open end of the dust brush is positioned to the centering pocket at the
extraction head.
FIG. 1
FIG. 3
FIG. 4
FIG. 5
FIG. 2
A
G
F
C
J
D
B
H
E
K
I
H
L
K
C
B
M
N
D
D
P
O
FIG. 6
/