NO
1. Push auger must be operational for meter motor to operate.
2. Is the Start light ashing?
3. Are there pellets in the hopper?
4. If push auger is turning and Stop light on control board is
ashing, Check encoder for proper voltage to and from control
board and if Molex is connected to the control board.
(See Diagram 3). Check continuity of metering motor.
5. Check for power to the meter motor, this will be an intermittent
power supply. (See Diagram 2).
6. Is hopper lid closed and lid switch actuated?
7. Connect power direct to motor to determine if operational.
(If slight movements check for jam)
8. Check Hopper lid switch for continuity.
9. Check Horizontal Rotating Disc (HRD) assembly for
fouling or jam.
10. Check pathway (with hopper CLOSED) from pin #6 to the end
of the RED wire pin #7 to WHITE wire.
11. Check to see if encoder molex is plugged in at board.
12. Remove pellets from the hopper; disconnect metering
motor to determine if HRD is spinning freely.
NOTE: Do not use a wrench or socket drive on 7/16”
retaining bolt on HRD to free a jam. Serious
damage can occur or bolt can be broken.
If this happens the stove must be returned
for repair.
Meter Motor
Turning
(HRD)?
YES
SEE NEXT PAGE.
Push
Auger
Turning?
YES
NO
1. Check vacuum and brass barb tube for blockage,
kinks, or cracks.
2. Check ow switch for continuity. No continuity
through ow switch when actuated, replace ow switch.
3. Check continuity of motor.
4. Check jumper wire between ow switch and push
auger for continuity. Check continuity from pin #7 to
White wire. If no continuity replace wiring.
5. Check for power to motor, this should be a constant
power supply (See Diagram 2).
6. Connect power direct to motor to determine if
operational. If not turning replace motor.
7. Check auger ight for jam.
8. If the ow switch is good and still no power to motor,
replace control board.
2
Copyright © 5/5/2016- Travis Industries Certified Factory Training Program
AGP™ Pellet Troubleshooting