WARNINGS!
INSTALLATION
• Read the instructions closely before installing and/or using the
hood.
• Themanufacturerwillnotbeheldliablefordamagecausedbyinstallation
thatisincorrectornotuptostandard.
• We recommend that all installation and adjustment procedures are
carriedoutbytrainedpersonnel.
• Whenthehoodistakenoutofitspackaginginspectittoensurethatit
isintact.Iftheproductisdamaged,donotuseitandcontacttheSmeg
assistanceservice.
• Before making any connections, make sure that the mains voltage
corresponds to the voltage shown on the label located inside the
appliance.
• ForClassIappliances,checkthatthedomesticpowersupplyguarantees
adequateearthing.
• Theminimumdistancebetweenthehobandthelowerpartofthehood
mustbeatleast750mmforgashobsand650mmforelectrichobs.
• Theextractedairmustnotbeconveyedinaductusedtoconductfumes
fromappliancespoweredbygas.
• Connecttheoutletfortheairextractedbythehoodtofumesdischarge
ductswithasuitableinternaldiameter,andnolessthan120mm.
• Theroommustbeadequatelyventilatedwhenthehoodorgasappliances
areusedsimultaneously.
• Ifthepowercableisdamageditmustbereplacedbythemanufacturer
oritstechnicalassistanceservice,ornonethelessbyanindividualwith
asimilarqualication,soastopreventanyrisk.
• Complywithanylegalregulationsrelativetotheextractionofairwhen
operatingtheextractionhood.
OPERATION
• Donotcookorfryinawaythatcreatesstrongames.Thesecouldbe
drawnintothehoodduringoperationandcauseare.
• Donotambéfoodunderthekitchenhood;Firehazard
• Thehoodcanbeusedbyindividualsundertheageof8andbyindividuals
withphysical,sensorialormentalimpairments,orwithoutexperienceor
therequiredknowledge,aslongastheyareundersupervisionorhave
EN
2
beengiveninstructionsonsafeuseoftheapplianceandarefamiliar
withthedangersitentails.
• Childrenmustbesupervisedtoensurethattheydonotplaywiththe
appliance
• ATTENTION:The accessible parts can become very hot if they are
usedwithcookingequipment."
MAINTENANCE
• Beforecarryingoutanymaintenanceprocedureorcleaning,disconnect
theappliancefromtheelectricitysupply.
• Carryoutthoroughandtimelymaintenanceoftheltersinaccordance
withtheintervalsrecommendedbythemanufacturer.
• Tocleanthehoodsurfaces,useadampclothandamildliquid
detergent.
• Cleaningandmaintenancecarriedoutbytheusermustnotbeperformed
bychildrenwithoutsupervision;
• THE MANUFACTURER DECLINES ALL RESPONSIBILITY IF THE
ABOVEINDICATIONSARENOTFOLLOWED
USE:
• ThisappliancewasdesignedtobeusedasanEXTRACTION(extraction
ofairtotheoutside)orFILTERhood(recirculationofairindoors).
• EXTRACTIONVERSION:Toturnthehoodintotheextractionversion
connectthemotorinlet,bymeansofarigidorexiblepipewithasuitable
internaldiameterandnolessthan120mm,directlytotheexternalvapour
andodourextractionduct.
NB.Removeanyactivecarbonodour-controllters.
• FILTER VERSION: If it is not possible to direct the air outdoors, the
hoodcanbetransformedintothelterversion.Inthisversion,theair
andvapoursarepuriedbyactivecarbonltersandrecirculatedintothe
roomthroughthelateralventilationgrillesoftheue.
EN
3
INSTALLATION INSTRUCTIONS:
Thehoodissuppliedwithalltheaccessoriesnecessaryfor
itsinstallation.Theminimumdistancebetweenthelower
surfaceofthehoodandthehobmustbeatleast750mm
for gas hobs and 650mm for electric hobs (Fig. 1 ). If
themotorinletisequippedwithanon-returnvalvefor
fumes,makesureitcanopenandclosefreely.
Foreasyinstallationitisrecommendedtofollowtheprocedures
describedbelow:
1)Thehoodmustbecentredwithrespecttothehobsurface.
2)There are differentinstallation procedures depending on
thehoodmodel.Chooseoneofthefollowingxingsystems
(Fig.2):
a) 2 levelling hooks that fasten on with the supplied
expansionplugs
b) Rearlevellingbracketthatfastensonwiththesupplied
expansionplugs
c) Levellinganchorsonmotorboxthatfastenonwiththe
suppliedexpansionplugs
d) For island models refer to the special installation
attachment.
N.B.:Fixingsystemsa)andb)tontothebackofthehood
intheholesL1(Fig.4).
3)Removethegreaseltersandpositionthehoodonthewall
andmarkthereferencepositionfortheholestoanchorthe
relativexingsystem.
4)Drillthe2holespreviouslymarkedafterremovingthehood
fromthewall
5)Anchor the xing system to the wall by tightening the
expansionplug
6)MarkholesL2onthewalltosecuretheplugssafelyinthe
holes.(plugssupplied)
7)Hang the hood on the xing system (g. 2) and level it
usingtheadjustmentscrews(g.2).
8)Securelyxthehoodbyfullytighteningthetwoexpansion
screwsoftheholesL2
AIRCONNECTIONSYSTEMS:
EXTRACTION version: Connect the fume expulsion duct
(insidediameter150mm.)totheexhaustofthemotorinlet.
IftheexpulsionductisD.120mm,usethespecialreduction
ange (F) supplied. The expulsion duct must not have a
diameteroflessthan120mm.
Notethat ifthehoodissuppliedwithanactivecarbon
lter,thismustberemoved(seepage8)
EN
4
FILTERversion:
Leavethemotorinletfree. Install the active carbon
ltersasshownonpage8.
Ifthehoodisnotsuppliedwithanactivecarbonlter
youmustbuyitseparatelyatyournearestauthorised
Smegdealer.
For some models there is a standard set of ttings
(g.5) to be xed to the wall by expansion plugs at
a suitable height in order to channel the airow in
correspondencewiththeueslits.Insertlaterallythe
extensionsR2onthettingR1.ConnectthettingR1
attheoutletofthehoodbodybymeansofatubeof
diameterD.150mm.
• FLUEASSEMBLY(g.6):
Positiontheuebracket(K)totherequiredtoplimit.
Markthetwoholesonthewalltoxthebracket.Drill
andxthebracketwiththesuppliedexpansionplugs.
Carefullyposition the ue unit on the hood. Fix the
lower ue to the hood by means of the screws Z.
Carefullyextendthetopuetotheupperlimit.
Secure the top ue to the ue bracket K using the
screwsL.
• ELECTRICCONNECTION
Werecommendthatelectricconnectionsarecarried
outbyaprofessionalinstaller.
Inthecaseofadirectelectricconnectiontothemains,
betweentheapplianceandthemains,placeabipolar
switch with a minimum opening of 3mm between
contacts, sized to the load and compliant with the
currentregulations.
EN
5
USER INSTRUCTIONS:
SLIDER:
- Slider(A)lightingON/OFF
- Slider(B)withfourpositions:
Pos.0:MotorOFF
Pos1/2/3:ON/Speedselection
ELECTRO-MECHANICAL PUSHBUTTON
PANEL:
LightsON/OFFkey
MotorOFFkey
Powerkey/hoodspeedselection
KNOBS:
-Knob(A):lightingON/OFF(0-1)
-Knob(B):
0 MotorOFFposition
1-2-3 Hoodspeedselection
Starttimedintensivespeed
• CONTROLSUNIT
Foranoptimalandefcientuseoftheproductitisadvisabletostartthehoodafew
minutesbeforeyoustartcookingandtokeepitonforatleast15minafteryouhave
nishedcookingoruntilsteamandodourshavecompletelydisappeared.Tostartthe
hood,identifythecommandtypeofthehoodandthenfollowtherelativeindications:
Timedintensivespeed:
Thetimedintensivefunctionisthatmodeofserviceforwhichthehood,foralimited
time,worksatitsmaximumcapacity.Thetimedintensivespeedofthehoodisactivated
byturningtheknob(B)clockwisefromposition3.Oncethetimedintensivespeed
isactivated,theknobautomaticallyturnstoposition3.Theintensivespeedcanbe
switched offbyturning the control (B) counter-clockwise again. When the intensive
EN
6
speedtimerhasexpireditreturnstothethirdspeedbydefault.
Control panel
2-DIGIT10-KEYCAPACITIVEPUSHBUTTONBOARD:
Key Function Display
A
Turns the suction motor on / off. Displays the set speed
B
Decreases the operation speed. Displays the set speed
C
Increases the operation speed. Displays the set speed
D
Activates the Intensive speed from any speed even with the
motor off, this speed is timed. At the end, the system returns
to the speed previously set. Suitable for dealing with the
maximum emissions of cooking fumes.
Displays alternately HI
Hold the button down for about 5 seconds, when all loads are
off (Motor + Light), to switch the keyboard lock On / Off.
"- -" Keyboard lock On.
E
24 H function
Activates the motor at the rst speed and allows extraction for
10 minutes every hour.
It displays 24 and the point at the bottom
right ashes once a second, while the
motor is in operation. Press the key to
disable it.
Holding the button down for about 5 seconds when all loads
are off (Motor + Light), holding key "B" down during the
animation, the Active Carbon Filters Alarm switches On / Off.
Displays a rotary animation for 5
seconds. "EF" ashes twice in activation.
"EF" ashes once in deactivation.
F
Delay function
Enables the automatic shutdown delay of 30'. Suitable for
removing residual odours. Can be activated from any position.
You disable it by pressing the key or turning the motor off.
Displays the operating speed and the
point on the lower right ashes.
G
With the lter alarm in progress, pressing the key for about 3
seconds resets the alarm.
After the procedure, the signal
previously displayed turns off:
FF signals the need to wash the metallic
grease lters. The alarm comes on after
100 hours of actual operation of the
Hood.
EF signals the need to replace the active
carbon lters and the metallic grease
lters must also be washed. The alarm
comes on after 200 hours of actual
operation of the Hood.
H
Decreases the light intensity at each press of the Key in a cyclic
manner.
1
Turns the lighting system on and off at maximum intensity.
L
Increases the light intensity at each press of the Key in a cyclic
manner.
EN
7
Keyboardlockcommand:youcanlockthekeyboard,forexample,tocleantheglass
surface, when the Hood has the motor and lights switched off. By pressing key D
forabout5seconds,youcanenableordisablethekeyboardlockwhichisalways
conrmedwith:
Thetimedintensivefunctionisthatmodeofserviceforwhichthehood,foralimited
time,worksatitsmaximumcapacity.
ActivatingthefunctionisdisplayedbytheLEDlocatedunderthekeyashing.When
“- -” Keyboard lock On.
CONTROL PANEL
KEY FUNCTION DISPLAY
A SWITCH THE SUCTION MOTOR ON / OFF. DISPLAYS THE SET SPEED
B DECREASE THE OPERATING SPEED DISPLAYS THE SET SPEED
C
INCREASE THE OPERATING SPEED
START TIMED INTENSIVE SPEED
DISPLAYS THE SET SPEED
FLASHING TIMED INTENSIVE SPEED
D TURN THE LIGHTING SYSTEM ON AND OFF
F
ENABLES THE AUTOMATIC SHUTDOWN
DELAY OF 15'
FLASHES
1-DIGITCAPACITIVEPUSHBUTTONBOARD:
SOFTTOUCHELECTRONICPUSHBUTTONBOARD:
LightsON/OFFkey
MotorspeedOFF/1key
Adjustmentkeyhoodspeed
Timedintensivespeedkey
Filtersresetkey
EN
8
theintensivespeedtimerhasexpireditreturnstothethirdspeedbydefault.
Beforeperforminganymaintenanceand/orcleaningalwaysdisconnectthehood
fromthepowersupply
Regularcleaningguaranteesgoodoperationandalongapplianceservicelife.The
greaseltersandlterhoodswithcarbonltersrequirespecialcare.
N.B.Theaccumulationofgreaseinsidethelterpanelsaswellasaffectingthe
performanceoftheextractor,canalsocreatearehazard.
Theexternalandinternalcleaningofthehoodmustbecarriedoutusingadampcloth
andmildliquiddetergent.Completelyavoidtheuse of solvents or abrasives. Itis
recommendedtousespecicproducts,followingtheinstructionsontheproduct.Itis
advisabletocleanthehoodbyalwaysrubbingthesteelinthedirectionofthesurface
nish.
- TIMEDAUTOPOWEROFF:Bypressingoneofthemotorspeedkeys(2-3),twice,
youwillactivatethefunction"TimedAutoPowerOff"whichturnsoffbothlightsandhood
motorafter10mins.ActivatingthisfunctionisdemonstratedbytheLEDimmediately
abovethepressedbuttonashing.
- FILTERCLEANINGSIGNAL:thesimultaneousashingofthe4LEDs,(programmed
torunevery200hofoperation),istoindicatetheneedtoclean/replacethelters.
BypressingtheResetbutton ,the200htimecanbereset.N.B.Accidentally
pressingtheresetbuttonbeforethe200hoperationcycledoesnotresultinthe
lterbeingresetintheltercleaningmemory.Itisgoodpracticetocleanthe
greaseltersandreplacetheactivecarbonltersevery200hofoperation.
OPTIONALFUNCTIONS:
FUNCTIONSANDMAINTENANCE:
EXTERNALCLEANING:
EN
9
Particular attention should be paid to the metal
greaselterpanels.Theaccumulationofgrease
inside the lter panels as well as affecting the
performance of the extractor, can also create a
rehazard.
Inordertominimisetheriskofre,theltersmust
be cleaned regularly, at least once a month or
withgreaterfrequencyinthecaseofaparticularly
intensiveuseoftheappliance.
Afteridentifyingyourhoodmodel,removeonelter
atatimeasshowninthenextgure.Thoroughly
washlterswithamilddetergenteitherbyhand
orinthedishwasher.Replacethelters,making
surethatthehandleisontheoutsideofthehood
Thecarbonltersarecapableofretainingodours
untilthecarbonreachessaturationlevel.They
cannot be washed and they are not renewable,
therefore,it isrecommendedtoreplacethemat
leasteverysixmonthsormoreoftenifthehoodis
usedoften.
Beforestartingoperationsmakesuretheelectrical
powersupplytothehoodisdisconnected.
Accesstheactivecarbonltersbyremovingthe
metalltersasdescribedabove.Withthehelpof
thegures,identifythecarbonlterskitsupplied
withthehood.
Inthecaseofthedisclter,simplytiltthetwolters
by90°asshownin(g.A)andthenextractthem
fromtheirhousing.
In the case of a cartridge lter attached with
springs, (g.B) exert the pressure required to
counteracttheresistanceofthespringandthen
removethelter
METALFILTERCLEANING:
REPLACINGCARBONFILTERS:(Onlyforthelterversion)
EN
10
Inthecaseofacartridgelterblockedwithabracketandthreadedknob,(g.C),unscrew
theknob,removethelockingbracketandthenremovetheactivecarbonlter.Replacethe
carbonltersandthemetalnon-greaseltersbyperformingtheoperationsininverseorder
Note:onlytheelectronically-controlledhoodcantheltercleaningwarningfunction
beresetbypressingthespeciclterresetbutton
Beforeperforminganymaintenance
and/or cleaning always disconnect
thehoodfromthepowersupply
Depending on the model, the hood can be
equippedwithdifferenttypesoflighting,withLED
orhalogenlamps:
a)WITHLEDLIGHTS:TheLEDlightsguarantee
a signicant number of hours of operation.
Shoulditbereplaceduetobeingwornorfaulty,
the entire spotlight must be replaced. In this
case,contactqualiedTechnicalSupport.This
applianceisequippedwithClass1MwhiteLED
light,inaccordancewithENstandard60825-1:
1994+A1:2002+A2:2001;maximumemitted
opticalpower@439nm:7μW.
 Do not look directly at the light with optical
instruments(binoculars,magnifyingglass...).
b)Halogen:lampwithG4tting,20Wpowerand
12V voltage. Replace the lamp by removing
the glass support ring of the spotlight with
a screwdriver. Once the glass is removed,
removethefaultylampfromitshousingandt
thenewlamp.Replacetheglassofthespotlight
byblockingitwiththering.
REPLACEMENTLAMPS:
EN
11
Pursuant to art. 26 of the Italian Legislative Decree dated 14 March
2014, no. 49 "Implementation of directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE)"
WEEEDISPOSAL:
Thecrossedoutwheeledbinsymbolontheequipmentoritspackaging
indicatesthattheproductattheendofitsusefullifemustbecollected
separatelyfromotherwaste.
Therefore,anyproductsthathavereachedtheendoftheiruseful
lifemustbegiventowastedisposalcentresspecializinginseparate
collectionofwasteelectricalandelectronicequipment.
Asanalternativetoautonomousdisposal,thedeviceyouwantto
disposeofcanbegivenbacktotheretaileratthetimeofpurchasing
newsimilarequipment.
Atelectronicproductretailerswithasalesareaofatleast400m2,itis
possibletoreturn,withoutanyobligationtobuy,electronicproductsto
disposeofwithdimensionsbelow25cmfreeofcharge.
Theseparatecollectionforthedeliveroftheequipmenttorecycling,to
treatmentandenvironmentallycompatibledisposalhelpsavoidpossible
negativeeffectsontheenvironmentandhealthandpromotesthereuse
and/orrecyclingofmaterialsthatmakeuptheequipment.
EN
12
WARRANTYANDTECHNICALASSISTANCESERVICE:
TheSmegWarrantyBookletisprovidedinthehoodpackagingas
wellasintheInstructionsforUseandMaintneance.Weinviteyouto
readtheSmegWarrantyBookletforcompleteandcomprehensive
informationonthewarranty.
*thecostforthecallis14cent/minfromlandlinesandanaverage18cent
connectionfeeplus35centperminfrommobilephones.
e-mail;[email protected]
website:www.smeg.it
Incaseoffailure,callthededicatedCustomer
Servicenumber
199.135.135.*
orlookunderSmeginthephonebook
for the capital of your province, and
alwaysprovide:
• the model, provided inside the hood
(g.7)
• yourfulladdress
• yourphonenumber
• Adescriptionofthetypeoffailure
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Smeg KPF9RD Owner's manual

Category
Cooker hoods
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI