Alecto WS-1200 ORIGINAL User manual

Category
Table clocks
Type
User manual
GEBRUIKSAANWIJZING
MODE D’EMPLOI
BEDIENUNGSANLEITUNG
USER’S MANUAL
WS-1200
Thermometer met klok en draadloze regenunit met thermosensor
Thermometre sans l avec horloge unite de pluie avec thermometre
Thermometer mit Uhr und mit funkgesteuertem
Thermoregensensor
Thermometer with clock and wireless rain unit
with temperature sensor
-31-
OVERVIEW
1. DCF reception icon
2. time and date
3. indoor temperature
4. outdoor temperature
5. rain unit reception icon
6. amount of rain
EN
7. alarm clock icon
8. temperature display in ºC or ºF
9. temperature display in ºC or ºF
10. low battery indication
11. No function
12.rainfall display (mm or inch)
13
13. rain meter with integrated thermometer + DCF receiver module
1
2
3
4
5
6
7
8
12
10
9
11
-32-
INSTALLATION
The rain unit can be installed outdoors on a horizontal or vertical object such
as the top of a wall, a beam or shelf, or against a wall.
The rain collector must be placed steady enough to be able to withstand and
wind inuences.
We recommend you to register the rain unit on the indoor unit before
installing the outdoor unit on a suitable spot. The rain unit will measure the
outdoor temperature and humidity. Since the temperature sensor is placed
inside the plastic box, the displayed temperature can be higher than the
actual temperature when exposing the box to direct sunlight
Rain unit batteries installation:
Remove the top container from the base plate.
AAA 1.5V
AAA 1.5V
When the cover is removed you can remove the battery cover.
AAA 1.5V
AAA 1.5V
Insert 2 x AAA 1.5V Alkaline batteries into the battery compartment, paying
attention to the correct polarity.
Now replace the battery cover.
Because the rain unit and indoor unit operate with a unique code, after
installing the batteries into the outdoor unit, the indoor unit should be
powered as soon as possible. After this installation, the code will be
synchronized within the rst 10 minutes.
For the rst 70 seconds, the indoor unit will be searching for the DCF clock
signal from Frankfurt to set the correct time.
The indoor unit is provided with a built-in DCF receiver. Through this receiver
the DCF clock signal from Frankfurt is received. This signal ensures that
the clock will display the precise current time, provided the signal is being
received properly. The DCF receiver is build into the indoor unit. Each day,
the DCF time is synchronized with the signal from Frankfurt at 2am, 8am,
2pm and 8pm. When the reception succeeds, the icon will appear.
It can take up to several hours before the time signal is received. When the
reception fails, you can try rotating the indoor unit until it does receive the
DCF signal.
-33-
Indoor unit:
Insert 2 Alkaline batteries type AA 1.5 Volt into the battery compartment
of the indoor unit according to the correct polarity. After the batteries are
installed, the indoor unit will emit a short beep tone.
After installing the batteries, the indoor unit will try to make contact with
the rain unit for the synchronization. When this succeeds, the indoor
temperature and the amount of rain (usually 0) will be displayed. During the
reception the “ ” icon will appear.
During the rst 10 minutes, please don’t press any buttons otherwise the
synchronization might fail.
If the outdoor temperature doesn’t appear after 10 minutes, please repeat
the registration procedure.
If the DCF time doesn’t appear quick enough, you can set the time manually
(see “setup”).
ATTENTION: during the registration process, please don’t press any buttons.
DISPLAY
General:
The actual temperature will only be shown after both the indoor and outdoor
units have been switched on for several hours while not being moved
-34-
INDOOR UNIT SETUP
Time and date:
The WS-1200 is provided with a built-in DCF receiver, used for receiving the
DCF time signal from Frankfurt.
You can also set the time manually. As soon as the DCF time is being
received, the indoor unit will automatically overwrite the time you’ve set
manually.
• Press and hold the “SET” button for 3 seconds until the language option
starts ashing. If you’re in a different time zone than the DCF clock signal,
you can use this option to change the time zone. For example, if you’re 1
hour ahead of the DCVF time, you can set the time zone to +1.
• Press the “+” or “-” button to adjust the time zone.
• Press the “SET” button to continue to the next setting.
• 24 hours or 12 hours time format.
• Press the “+” or “-” button to switch between 24 hours or 12 hours format.
• Press the “SET” button to the hours.
• Press the “+” or “-” button to set the correct hours.
• Press the “SET” button to set the minutes.
• Press the “+” or “-” button to correct minutes.
• Press the “SET” button to set the year.
• Press the “+” or “-” button to set the correct year.
• Press the “SET” button to set the month-date or date-month format.
• Press the “+” or “-” button to set the format.
• Press the “SET” button to month.
• Press the “+” or “-” button to set the correct month.
• Press the “SET” button to set the date.
• Press the “+” or “-” button to set the correct date.
• Press the “+” or “-” button to correct minutes.
• Press the “SET” button to set the temperature display to ºC or ºF.
• Press the “+” or “-” button to switch between ºC and ºF.
• Press the “SET” button to set the rain format mm or inch.
• Press the “+” or “-” button to select, mm or inch.
• Press the “SET” button or don’t press any button for 10 seconds to exit the
programming mode.
You can also press and hold the “+” or “-” button for over 3 seconds to adjust
the values quicker.
-35-
Amount of rainfall:
The display of your weather station indicates the amount of rainfall, which
can be set to per mm of per inch (see indoor unit setup). Most English
speaking areas use the inch value.
The amount of rainfall can be displayed per time unit; 1 hour, 24 hours,
week, month or everything in total.
• Press the “RAIN” button to switch between the above mentioned time
units.
To reset a value, rst select the desired value.
• now press and hold the “RAIN” rain button for at least 2 seconds until the
value is deleted.
To delete all rainfall values, select “TOTAL” and delete the data.
• now press and hold the “RAIN” rain button for at least 2 seconds until the
value is deleted.
Display of the minimum and maximum values:
For the temperature value, the measured minimum or maximum value can
be displayed.
For the amount of rainfall, the maximum value per time unit hour and day
can be displayed.
• Press the “MIN/MAX” button to display the highest indoor temperature
pressure measurement.
• Press the “MIN/MAX” button again to display the lowest indoor
temperature measurement.
• Press the “MIN/MAX” button to display the highest outdoor temperature
pressure measurement.
• Press the “MIN/MAX” button again to display the lowest outdoor
temperature measurement.
• Press the “MIN/MAX” button again to display the maximum rainfall in an
hour.
• Press the “MIN/MAX” button again to display the maximum rainfall in a
day.
• Press the “MIN/MAX” button again or press no buttons for 10 seconds to
exit the max/min display mode.
Deleting minimum and maximum values:
Use the “MIN/MAX” button to go to the data you’d like to delete.
Now press and hold the “MIN/MAX” button for at least 2 seconds until the
value changes into the actual value. The minimum and maximum registration
of the concerned value will now be reset.
Setting the alarm clock.
The WS-1200 is provided with an alarm clock, after setup you can activate
one wake-up time. As soon as the set time is reached, the alarm will sound.
• Press and hold the “ALARM” button for at least 3 seconds until the hours
of the alarm time start ashing.
• Press the “+” or “-” button to set the correct hours.
• Press the “ALARM” button to set the minutes.
• Press the “+” or “-” button to set the correct minutes.
• Press the “ALARM” button or wait for 10 seconds to leave the
programming mode.
-36-
The alarm active “ ” icon will now appear.
This function will be activated immediately while setting the alarm.
Press the “Alarm” button to deactivate the alarm.
Press the “Alarm” button to activate the alarm.
When the alarm time is reached, a beep signal of 1 beep tone will sound for
the rst 30 seconds. For the next 30 seconds a beep signal of 2 beep tones
will be emitted. For the next 30 seconds 3 beep tones and for the last 30
seconds continuous beep tons. After these 2 minutes, the alarm signal will
stop en the alarm clock is reset to the next alarm time in 24 hours.
Press a random button to stop the alarm signal beforehand.
POSITIONING TIPS
• Never place the indoor unit in direct sunlight and keep it away from heat
generating objects (lights, heaters, etc.)
• For a strong reception of the radio controlled time signals, never
place the rain unit next to large metal surfaces or devices with strong
electromagnetic elds.
• The effective range between the rain unit and indoor unit can vary
depending on local circumstances. Please check whether the connection
between the rain unit remains established before xing the rain unit in a
permanent spot.
• The range between the indoor and rain unit may not be over 50 meters
-37-
SPECIFICATIONS
Indoor unit:
indoor temperature measurement range:
-9,9°C ~ +80°C - resolution: 0.1°C
alarm time:
maximum 120 seconds
Rain unit:
range in open area:
maximum 100 meters
transmitting frequency:
433,9MHz ±250KHz
Maximum Power:
< -14.95 dBm
outdoor temperature measurement range:
-40°C ~ +65°C
resolution: 0.1° C
rainfall volume:
0 – 19.999mm
rain unit measurement interval:
48 seconds
water-proof rating:
IPX3
power usage:
15mA (while transmitting), 10µA (standby)
Power supply:
indoor unit
2x 1,5V LR6 battery, type AA, alkaline
rain unit
2 x 1.5V LR03 batteries, size AAA, alkaline
battery use:
Minimum 12 months for indoor unit and rain unit
DECLARATION OF CONFORMITY
This equipment complies with the essential requirements and provisions as
described in the European Directive 2014/53/EU.
The declaration of conformity is available at:
http://DOC.hesdo.com/WS-1200-DOC.pdf
Frequency: 433,9MHz
Maximum Power: < -14.95 dBm
-38-
RESET/SYSTEM ERROR
If you’ve lost the overview of the settings or the WS-1200 appears to be
malfunctioning, we recommend you to reset the indoor and rain units.
• Remove the batteries from the indoor and rain unit. Wait at least 10
seconds and then replace the batteries or replace them with new batteries
(see “INSTALLATION”). If the fault persists, please contact the Alecto
customer service via phone number +31 (0) 73 6411 355
MAINTENANCE
Clean the indoor unit with a slightly moist cloth on a regular basis.
Clean the exterior of the rain meter with a slightly moist cloth. Make sure that
all of the holes on the outside (top and bottom) are properly opened. Make
sure that the surface of the rain collector is clean. Open the rain unit by
pressing the cover at the side and then pulling it up.
Clean the interior of the rain meter to remove deposits, dirt and insects.
Make sure the shaft of the teeter-totter is clean and check whether the
teeter-totter can move freely. After cleaning, replace the cover onto the rain
meter.
-39-
WARRANTY
Name:
Address:
Post code:
City:
Telephone:
For the Alecto WS-1200 you have a warranty of 24 months from the date
of purchase. During this period, we guarantee the free repair of defects
caused by material and workmanship errors. All this subjected to the nal
assessment of the importer.
HOW TO HANDLE:
If you notice any defect, rst refer to the user’s manual or Alecto website. If
you can’t nd a decisive answer here, please contact your dealer with a clear
complaint description. The dealer will then accept the product with this proof
of warranty and the dated proof of purchase and ensure a speedy repair or
otherwise send it post paid to the importer.
THE WARRANTY BECOMES NULL AND VOID:
In case of improper use, incorrect connections, leaking and/or incorrectly
installed batteries, use of unoriginal parts or accessories, negligence and
in case of defects caused by moisture, re, ooding, lightning and natural
disasters. In case of unauthorised modications and/or repairs performed
by third parties. In case of incorrect transportation of the device without
adequate packaging and when the device is not accompanied by this
warranty card and proof of purchase.
All further liability, especially concerning any consequential damages, is
excluded
Attach here your
receipt or voucher
ver. 2.2
Service
Help
Service Help
WWW.ALECTO.NL
Hesdo, Australiëlaan 1
5232 BB, ‘s-Hertogenbosch
The Netherlands
WWW.ALECTO.NL
Hesdo, Australiëlaan 1, 5232 BB,
‘s-Hertogenbosch,
The Netherlands
v3.0
v3.0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Alecto WS-1200 ORIGINAL User manual

Category
Table clocks
Type
User manual

Ask a question and I''ll find the answer in the document