CONTENT
SAFETY INFORMATION 3
TECHNICAL FACTS 3
INSTALLATION TO WELL OR SEA/LAKE 4
SAFETY INFORMATION
There are some things that are especially important for the brackish-commercial model.
• The water purifier is intended to produce water
for applications that require purified water.
• Check that the water you intend to purify
meets the requirements specified in “Technical
facts”.
• When the purifier is installed to purify water
from a well or sea/lake a pre-filter is required
before the purifier.
• It is very important that the purifier is
connected to water and electricity. Brackish
water often contains organic materials that will
increase the bacteria growth. To prevent this
an automatic flush is performed every 12 hour.
• If the purifier is to be disconnected from water
and electricity it should be stored as described
in “Storage”. Otherwise the bacteria growth
will start and the purifier will take on an odour.
• Every time after drawing water, or every 15
minutes in each operating cycle and when
connecting the plug, automatic flushing takes
place.
• Concerning the installation, the material in all
components at the intake- and drain
connections must be resistant to corrosion, for
example plastic or stainless steel.
• When calibrating the purifier make sure the
water temperature is 2-20 °C. If it is higher
there may be a risk that the water will taste of
salt before low purification level is indicated on
the control panel.
TECHNICAL FACTS
Data
Capacity: the values apply to a new membrane
and the salt content 600-7500 mg/l.
Temperature 5 °C 2.0 (±0.5) l/min
Temperature 15 °C 2.5 (±0.5) l/min
Temperature 25 °C 3.0 (±0.5) l/min
Max 500 l/day
Water efficiency:
During operation: approx. 50 %
Including flushing: approx. 40-50 %
Start pressure: 0.5 bar (50 kPa)
Stop pressure: 2 bar (200 kPa)
Operating cycle unlimited
(automatic flushing every 15 minutes in the
operating cycle)
Requirements on feed water to the
purifier
Water temperature 2 - 30 °C
Conductivity <1300 mS/m
/salt <7500 mg/l
/chloride Cl
-
<4500 mg/l
Iron Fe
2+
<1.5 mg/l
Iron Fe
3+
<0.3 mg/l
Manganese Mn <0.3 mg/l
COD-Mn O
2
<5 mg/l
Other requirements see ”Technical facts” in the
manual for the basic model.
Rejection
Sodium and chloride are not separated in the
same extent because of the high salt content.
Chloride > 95 %
Sodium > 92 %
More parameters see ”Technical facts” in the
manual for the basic model.
3