Dometic RO400BCV-HR User manual

Type
User manual

This manual is also suitable for

ADDITIONAL PAPER
ZUSATZHANDBUCH
DOCUMENT ADDITIONNEL
AANVULLENDE INFORMATIE
PAPEL ADICIONAL
TILLÄGGSBLAD
LISÄOHJE
Confidence RO 400BC
WATER PURIFIER
REVERSE OSMOSIS
EN
DE
FR
NL
ES
SE
FI
8229016-34
1
WP 05
YOUR NEW WATER PURIFIER
EN This manual only brings up the difference between the regular purifier and the brackish-
commercial model. It is important that you read both manuals carefully.
The English manual starts at page 3.
DE Dieses Handbuch bezieht sich nur auf die Unterschiede zwischen dem Basismodell und dem
Brackwasser-kommerziell Modell. Es ist wichtig, daß Sie beide Handbücher aufmerksam lesen.
Das Handbuch in Deutsch beginnt ab Seite 5.
FR Ce manuel précise uniquement la différence entre le modèle de base et le modèle pour eau
saumâtre-commercial. Il est important de lire attentivement les deux manuels.
Le manuel en français commence page 7.
NL In deze handleiding wordt het verschil tussen het basismodel en het model voor brak water-
commercieel beschreven. Het is van belang dat u beide handleidingen zorgvuldig doorleest.
De Nederlandse handleiding begint op pagina 9.
ES Este manual indica la diferencia entre el modelo básico y el modelo de agua salada-comercial. Es
importante que lea detenidamente ambos manuales.
El manual en Español empieza en la página 11.
SE Denna manual tar endast upp skillnaden mellan sötvatten modellen och bräcktvatten-
kommersiella modellen. Det är därför viktigt att Du läser igenom BÅDA bruksanvisningarna.
Manualens svenska handledning börjar på sidan 13.
FI Tässä käyttöohjeessa käsitellään ainoastaan makean veden ja murtoveden-kaupallisille
puhdistamiseen tarkoitettujen laitteiden eroja. Siksi on tärkeää, että luet molemmat käyttöohjeet
läpi.
Suomenkieliset ohjeet alkavat sivulta 15.
2
CONTENT
SAFETY INFORMATION 3
TECHNICAL FACTS 3
INSTALLATION TO WELL OR SEA/LAKE 4
SAFETY INFORMATION
There are some things that are especially important for the brackish-commercial model.
The water purifier is intended to produce water
for applications that require purified water.
Check that the water you intend to purify
meets the requirements specified in “Technical
facts”.
When the purifier is installed to purify water
from a well or sea/lake a pre-filter is required
before the purifier.
It is very important that the purifier is
connected to water and electricity. Brackish
water often contains organic materials that will
increase the bacteria growth. To prevent this
an automatic flush is performed every 12 hour.
If the purifier is to be disconnected from water
and electricity it should be stored as described
in “Storage”. Otherwise the bacteria growth
will start and the purifier will take on an odour.
Every time after drawing water, or every 15
minutes in each operating cycle and when
connecting the plug, automatic flushing takes
place.
Concerning the installation, the material in all
components at the intake- and drain
connections must be resistant to corrosion, for
example plastic or stainless steel.
When calibrating the purifier make sure the
water temperature is 2-20 °C. If it is higher
there may be a risk that the water will taste of
salt before low purification level is indicated on
the control panel.
TECHNICAL FACTS
Data
Capacity: the values apply to a new membrane
and the salt content 600-7500 mg/l.
Temperature 5 °C 2.0 (±0.5) l/min
Temperature 15 °C 2.5 (±0.5) l/min
Temperature 25 °C 3.0 (±0.5) l/min
Max 500 l/day
Water efficiency:
During operation: approx. 50 %
Including flushing: approx. 40-50 %
Start pressure: 0.5 bar (50 kPa)
Stop pressure: 2 bar (200 kPa)
Operating cycle unlimited
(automatic flushing every 15 minutes in the
operating cycle)
Requirements on feed water to the
purifier
Water temperature 2 - 30 °C
Conductivity <1300 mS/m
/salt <7500 mg/l
/chloride Cl
-
<4500 mg/l
Iron Fe
2+
<1.5 mg/l
Iron Fe
3+
<0.3 mg/l
Manganese Mn <0.3 mg/l
COD-Mn O
2
<5 mg/l
Other requirements see ”Technical facts” in the
manual for the basic model.
Rejection
Sodium and chloride are not separated in the
same extent because of the high salt content.
Chloride > 95 %
Sodium > 92 %
More parameters see ”Technical facts” in the
manual for the basic model.
3
INSTALLATION TO WELL OR SEA/LAKE
Contact your dealer for more information about installing to a well or to a sea or lake.
Suction installation
This must be carried out with a coarse screen
to separate large particles.
The coarse screen should be easy to clean.
The coarse screen must be installed vertical
position.
The suction nozzle must be beneath the water
surface and unaffected by wind and waves.
The suction nozzle must be placed at least 1
m from the bottom.
Hose
The hose must be:
Placed in a frost proof depth or together with a
heating cable.
Protected from direct sun light, wind, waves
and ice.
Feed pump/plant
Water pressure: 1.5-10 bar
(150-1000kPa)
Water flow: 10 l/min
Extra pre-filter
When the purifier is installed to purify water from a
well or sea/lake a pre-filter is required before the
purifier. When the inlet pressure decreases and
the water purifier alarms for low inlet pressure it is
time to replace the pre-filter. (See section
“Trouble-shooting table” in the manual for the
basic model.)
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Dometic RO400BCV-HR User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI