DKS Magnetic Gate Locks User manual

Type
User manual
1200 Lb. Magnetic Gate Lock Kit DoorKing Part Numbers
1216-080
1216-081
It is essential that the surfaces of the armature and the magnetic lock seat perfectly to one another when the gate is in the closed
position. This allows the lock to achieve its maximum holding strength. It is critical the armature is securely fastened to the gate
frame, but able to move with the 1/8 to 1/4 inch rubber spacer(s) to correctly align with the magnetic lock.
Important: Weld the
brackets to fence post and
gate frame BEFORE
assembling the armature
and maglock.
Note: Additional hardware is
supplied for a side mount option
and different armature spacing
configurations.
DoorKing Optional Hardware Note: “L” and “Z” bracket kit
(P/N BO3-S12) is available for different installation configurations.
Sexnut Note: Using the sexnut,
the armature can be mounted
directly to the gate frame
without using the supplied
armature mounting bracket.
Secure sexnut through the gate
frame and into armature bolt.
Front Mount Typical
Maglock
Front Mount Typical
1” Welded Bracket Armature Bolt
1 1/2” Armature Bolt
Wiring
Access Plate
P/N B02-GL12
(Supplied)
P/N B01-GL12
(Supplied)
Plug unused
1/2” conduit
holes.
Maglock
Mounting
Bracket
Weld to fence post.
(Typical connection)
Side Mount Option
Side Mount Option
Installation
Armature
Bolt
Options
Maglock
Typical Front Mount Welded
Moving Gate Frame
Armature
Gate Frame
Armature
Sexnut
Stationary Fence Post
Welded Mounting Brackets
Armature
Thinner
Option
Typical
Thicker
Option
Insert
Roll Pin
Insert
Roll Pin
Sexnut Connection
Option
(Not used for welded
bracket option.)
Armature
Mounting
Bracket
Weld to gate frame.
(Typical connection)
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
Indoor
12 or 24 VDC Wire Run
16 AWG - 200 Ft
18 AWG - 100 Ft
Polarity Matters!
Use
Only
Indoor
Use
Only
MOV Note: Install the supplied
MOV across the power supply
terminals to protect the magnetic
lock from transient voltage spikes.
DoorKing Part Number
1216-080
Relay
1216-080 Wire for 24 VDC or 12 VDC ONLY
24 VDC Transformer
(Model 1812-035)
24 VDC
12 VDC
12 VDC Transformer
(Model 1812-037)
Black
Green
Red Positive
Positive
Negative
Negative
White
Access Control Device
or Gate Operator
(Normally Closed)
Access Control Device
or Gate Operator
(Normally Closed)
Relay
Red
Black
White
Green
MOV
MOV
Indoor
12 or 24 VDC Wire Run
16 AWG - 200 Ft
18 AWG - 100 Ft
Polarity Matters!
Use
Only
Indoor
Use
Only
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
1216-065-C-10-23 Copyright 2023 DoorKing®, Inc. All rights reserved.
MOV Note: Install the supplied
MOV across the power supply
terminals to protect the magnetic
lock from transient voltage spikes.
DoorKing Part Number
1216-081
Relay
1216-081 Wire for 24 VDC or 12 VDC ONLY
24 VDC Transformer
(Model 1812-035)
24 VDC
12 VDC
12 VDC Transformer
(Model 1812-037)
Red - Normally Closed
Black - Common
Green - Normally Open
Black
Pink
Blue Positive
Positive
Negative
Negative
White
LED Lock Status Sensor
Relay Contacts
Rated 1 amp @ 30 Volt max.
(Model 1216-081 Only)
LED Lock Status Sensor
Relay Contacts
Rated 1 amp @ 30 Volt max.
(Model 1216-081 Only)
Access Control Device
or Gate Operator
(Normally Closed)
Access Control Device
or Gate Operator
(Normally Closed)
Relay
Red - Normally Closed
Black - Common
Green - Normally Open
Blue
Black
Pink
White
MOV
MOV